| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹55,040Qualified Make: BPE
Model: BPE 1kva Line INteractive 7 ah 2 nos battery 2 years AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE 1kva Line INteractive 7 ah 2 nos battery 2 years | L1 | Qualified | |
| 2 | L2₹1.3 L+₹77,760 (141.3%)Qualified Make: APC
Model: APC 1-KVA UPS - 30 Minutes Backup 00 GAYATRIPURAM GAYATRIPURAM KASYA ROAD DEORIA UTTAR PRADESH 274001 | DEORIA | UTTAR PRADESH | 274001 | Make: APC
Model: APC 1-KVA UPS - 30 Minutes Backup | L2 | Qualified | |
| 3 | Disqualified Make: microtek
Model: MICROTEK UPS 1000VA C 101 5 FIRST FLOOR TAGORE NAGAR RAIPUR CHHATTISGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | Make: microtek
Model: MICROTEK UPS 1000VA | - | Disqualified | |
| 4 | Disqualified Make: UTL
Model: UTL-1KVA AYODHYA BYPASS ROAD BHOPAL MADHYA PRADESH 462041 | BHOPAL | MADHYA PRADESH | 462041 | Make: UTL
Model: UTL-1KVA | - | Disqualified | |
| 5 | Disqualified Make: ZEBRONICS
Model: ZEB-U1200 28 A 28 A AJANTA COMMERCIAL CENTER ASHRAM ROAD INCOME TAX AHMEDABAD 380014 INCOME TAX AHMEDABAD CITY GUJARAT 380014 | AHMADABAD | GUJARAT | 380014 | Make: ZEBRONICS
Model: ZEB-U1200 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
6 Aug 2018, 3:00 pmClosed
Online UPS Experience with Gov. Required 5 Year (s) Online UPS ( 16 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA 1.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT- PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 800 1000
1100
800 Warranty for UPS (Years) 2 1
2
3
4
5 1/4 Movable trolly for Batteries Without With
Without
Without trollery but with rack Warranty for battery 1 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put Without With
Without Paralleling kit for synchronising With With
Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Yes - 2/4 Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. ISO 9000 - 2000 - Type Test Certificate date ISO 9000 - 2000 - Name of Lab ISO Pune - Address of Lab ISO Pune - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pradeep Khanna 531163
INS KALINGA 16 15
400530
GEM/2018/B/56685
Online UPS
15 days
Andhra Pradesh; Visakhapatanam
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Experience with Gov. Required 5 Year (s) Online UPS ( 16 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA 1.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT- PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 800 1000 | - | - | - |
| 1100 | - | - | - |
| 800 Warranty for UPS (Years) 2 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 1/4 Movable trolly for Batteries Without With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 1 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put Without With | - | - | - |
| Without Paralleling kit for synchronising With With | - | - | - |
| Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Yes - 2/4 Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. ISO 9000 - 2000 - Type Test Certificate date ISO 9000 - 2000 - Name of Lab ISO Pune - Address of Lab ISO Pune - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pradeep Khanna 531163 | - | - | - |
| INS KALINGA 16 15 | - | - | - |
Exempted
6 Aug 2018
30 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_400530.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .