| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC GUT NO 256 PLOT NO 62 GAJANAN NAGAR CHIKALTHANA AURANGABAD GAJANAN NAGAR CHIKALTHANA AURANGABAD MAHARASHTRA 431007 | AURANGABAD | MAHARASHTRA | 431007 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.8 L+₹29,765 (6.64%)Rejected-Finance 3 6 753 A GENERAL ELECTRICALS REFRIGERATION 3 6 753 A HIMAYATHNAGAR ST NO 14 40 HYDERABAD TELANGANA 500029 | HYDERABAD | TELANGANA | 500029 | L2 | Rejected-Finance Price not competitive. | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Meeting all NIT prequalification criteria |
Tender Value
₹4.5 L
EMD Value
₹9,100
Closing Date
6 Dec 2024, 4:00 pmClosed
Senior Manager ( Engg-E)
Airports Authority of India, Kadapa Airport AP 516003
Provision of Air Conditioners for AAI project office at Kadapa Airport
2024_AAI_214529_1
AAI/KDP/ENGGE/PRO-AC/2024-25
Open Tender
Electrical Works
Works
30 days
Kadapa, Andhrapradesh
As per NIT
13 documents required · 13 mandatory
₹1,180
₹9,100
28 Mar 2025
14 Nov 2024
9 Dec 2024
15 Nov 2024
6 Dec 2024
15 Nov 2024
15 Nov 2024 - 22 Nov 2024
Amount
Supply of 1.5 TR, 5 star ( ISEER = 5 or more) inverter type Hi-Wall split Airconditioner units with rated cooling capacity of minimum 5100w fitted with copper wound motor, hermetically sealed rotary/scroll/swing compressor suitable for operation on 230V,50Hz supply with evaporator & condensing unit having copper coil including cordless remote control, refrigerant copper piping of suitable size between Indoor and Outdoor units insulated with nitrile/polythene foam i/c electrical cable of suitable size between indoor to outdoor units( both upto 3Mtrs) and required size drain piping upto 4Mtrs etc., complete as required.
Supply of 2 TR, 5 star ( ISEER = 5 or more) inverter type Hi-Wall split Airconditioner units with rated cooling capacity of minimum 6100w fitted with copper wound motor, hermetically sealed rotary/scroll/swing type compressor suitable for operation on 230V,50Hz supply with evaporator & condensing unit having copper coil including cordless remote control, refrigerant copper piping of suitable size between Indoor and Outdoor units insulated with nitrile/polythene foam i/c electrical cable of suitable size between indoor to outdoor units( both upto 3Mtrs) and required size drain piping upto 4Mtrs etc., complete as required.
Supply, Installation, Testing & Commissioning of wall mounting type electronic voltage stabilizer suitable for 1.5 TR split air conditioners having input voltage range of 170V AC -270 V AC with high & low voltage cut off protection, overload protection, instant start & intelligent time delay etc. complete as required. (Make: V-Guard / Microtek/ Voltas/ equivalent)
Supply, Installation, Testing & Commissioning of wall mounting type electronic voltage stabilizer suitable for 2 TR split air conditioners having input voltage range of 170V AC -270 V AC with high& low voltage cut off protection, overload protection, instant start & intelligent time delay etc. complete as required. (Make: V-Guard / Microtek/ Voltas/ equivalent)
Installation, Testing and commissioning of 1.5 TR Split Air-conditioning units i/c fixing of Indoor and Outdoor units, providing and fixing suitable wall mounted brackets/stand for outdoor unit with anticorrosive & finish paint, making cabling interconnections, drain piping, refrigerant piping including chiseling & making the surface good as per site condition complete etc. as required
Installation, Testing and commissioning of 2 TR Split Air-conditioning units i/c fixing of Indoor and Outdoor units, providing and fixing suitable wall mounted brackets/stand for outdoor unit with anticorrosive & finish paint, making cabling interconnections, drain piping, refrigerant piping including chiseling & making the surface good as per site condition complete etc. as required
Relocation of 1.5 TR Split AC including dismantling its indoor unit, Outdoor door unit, refrigerant & drain pipe arrangements, outdoor stand if any, interconnected cabling between indoor & Outdoor units, outdoor stand if any, along with accessories by disconnecting its power supply, loading/unloading, shifting, reinstalling the same at new location, refrigerant filling and topup if required, as decided by AAI including minor civil works, testing and commissioning etc., complete as required.
Relocation of 2 TR Split AC including dismantling its indoor unit, Outdoor door unit, refrigerant & drain pipe arrangements, interconnected cabling between indoor & Outdoor units,outdoor stand if any, along with accessories by disconnecting its power supply, loading/unloading, shifting, reinstalling the same at new location, refrigerant filling and topup if required as decided by AAI including minor civil works, testing and commissioning etc., complete as required.
Supplying and fixing of 63A , four pole, 415 volts, residual current circuit breaker (RCCB),having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required including disconnection and removal of existing isolator from DB.
Supply and installation of outdoor wall mounted type polycarbonate cable junction box along with required connectors and other accesories, suitable for terminating PVC /XLPE insulated and PVC sheathed power cables of following size with knockouts for input and output feeders etc.,complete as required. Upto 95 Sqmm
Laying and fixing one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 Sq.mm (clamped with 1mm thk saddle)
Laying and fixing one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface, including dismantling the existing cable laid at site etc. as required. a) Above 35 Sq.mm and upto 95 Sq.mm (clamped with 25 x 3mm MS Flat clamp)
Supplying and making end termination with brass compression gland and suitable lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm
Supplying and making end termination with brass compression gland and suitable lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm
General Electricals and Refrigeration (BID ID -781052)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .