Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹42.3 L+₹4.6 L (12.3%)Rejected-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹43.3 L+₹5.6 L (14.9%)Rejected-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹43.9 L
EMD Value
₹87,760
Closing Date
22 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVISION OF PROTECTIVE WORK SECURITY LIGHT AND OTHER MICS WORK AT DEALRAIPUR ROAD UNDER GE (I) R N D DEHRADUN
2022_MES_498706_1
GE(I)RND/9099/E8/21-22
Open Tender
Civil Works
Item Rate
180 days
DEHRADUN
Class D Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2020) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
₹87,760
29 Jan 2022
1 Jan 2022
24 Jan 2022
1 Jan 2022
22 Jan 2022
8 Jan 2022
1 Jan 2022 - 8 Jan 2022
60 days
Amount
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
Rough excavation not exceeding 1.5 m deep and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for laying of cable etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm watering and removing surplus soil to a distance not exc. 50 m and making good surface as in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
M&L for dry sand cushioning under floors/cable in trenches/ducts including spreading levelling and hand paning and consolidating complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance exc. 5.0 km but n exc. 15 km and depositing where directed complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M & L for forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape,etc., n exc. 1.5 m high from base complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M & L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water throughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for M & L for block masonry with solid pre-cast cement concrete blocks made out of cement concrete 1: 2: 4 type C-1, using 20 mm graded stone aggregate, exc. 10 cm in width and setting in cement mortar 1 : 4 complete all as specified and directed.
M & L for forming fair finished drain or channel exc 45 cm and upto 60 cm inner girth in cement concrete, using extra cement including forms, moulds, mitered / stopped ends etc. complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
S & F of wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work onforming to Fe-290 Gde E-165 complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 8 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F of Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S & F of steel work as in tubular posts including special shaped washers etc. complete using ERW or induction butt welded complete all as specified and directed.
S & F of mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut, exc 10cm and n exc 15cm long and 11 to 15 mm dia of neck complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Supply only Chain link MS galvanisd fencing, any size or type (Mesh 50mmx50mm and 3.00 mm dia )complete all as specified and directed.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed . NOTE:- Corrugated shape of sheet shall be approved by GE
M & L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M & L for providing 40 mm thick cement concrete 1:2:4 type B-0 (using 12.50 mm thick graded stone aggregate) as in floor finisshes even and fair to receive floor tilese complete all as specified and directed.
M & L for machine pressed precast concrete rubber moulded glossy finish with pigment in two different colours interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade.grade complete all as specified and directed.complete all as specified and directed. NOTE:- Colour shall be approved by GE
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparation of steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for preparation of new or previously untreated brick, stone, concrete, asbestos cement or plastered surfaces over 10 cm width or girth and applying two coats of Stone/Floor paint over a coat of priming paint plaster complete all as specified and directed.
S & F of 450 mm bore reinforced concrete pipe class NP-2 laid, jointed with collar in neat cement slurry complete all as specified and directed.
S&L XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade cross sectional area 16 Sqmm and 4 core complete all as specified and directed.
S&L XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade cross sectional area 35 Sqmm and 3.50 core complete all as specified and directed.
M&L for laying GI tubing light grade 40mm dia with all fittings & GI MS clamps of 50 x 6 mm incl nuts and washers for fixing of GI pipe complete all as specified and directed.
M&L for well burnt brick with sub class ‘B’ old size bricks for protection of cable complete all as specified and directed.
Supplying, laying, jointing & testing sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1.50 Sqmm as earth continuity conductor complete all as specified and directed.
Supplying and fixing in position new Pole box of size 139 mm X119 mm X70 mm with pannel lock made of thermoplastic Polycarbonate having IP65/IP66 degree of protection (shock proof, dust proof, jet water proof and acid resistive). The gasket should be internally embedded, and made of Polyeutherene. The boxes shall be tested as per IEC 60670-2/ 60670-22. The boxes shall have self threaded holes & provision for mounting din rail. The lid should be hinged type with sealing screw. The screw should be of stainless steel so that there is no corrosion. The boxes should withstand temperature of -40c to +120c. The glow wire test should be conducted at 960 c or 750 c and material should be flame retardant & self extinguishing. UL subject 94, V-0. The boxes should be free from toxic substances like hal ogen and silicon. The boxes should have suitable pre-moulded knock out /or plan wall depending on requirement. Box shall be suitable for 16/25Sqmm cables including one no. MCB SP 230 volts 6 amps of make Havells/Legrand/ABB and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5mm FI clamps,nuts,bolts & washers complete all as specified and directed.
Supplying transporting and erecting in position steel tubular swaged poles 410-SP-31 type 9.00 M long complete with mild steel base plate, CI finial taper, bolts, outs and washer etc including necessary excavation and earth work PC 1:4:8 type D2 in foundation below pole PCC 1:3:6 type CI as in plinth block, disposal of surplus soil to a distance not exceeding 5 cm and depositing where directed painting steel tubular poles exposed surfaces with aluminium paint two coats over one coat of red oxide primer and providing 3 bands/straps with synthetic enamel paint red single post office colour and 2 coats with white colour paint 300mm apart from plinth block and numbering of poles, painting emended portion of poles with one coat of bituminous paint complete all as specified and directed. NOTE:- street light bracket made out of 32mm dia GI tubing medium grade made to shape 1.2 mtr long incl duly painted with synthetic aluminium paint over a coat of primer. MS clamps and back plates fabricated from steel section including nuts, bolts, washers items required to be included in the unit rate quated.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge.Make: C&S cat Pt No.LTESSE90WLED or equivalent in Havells/C&G Note : GI pipe bracket and clamps if required shall be measured and paid separately complete all as specified and directed.
Supply and fixed MCCB 4 pole, 63 Amps 415 volts, 50 Hz confirming to IEC-60947-II having breaking capacity Ics= 25 KA ,lcs=100% lcu with fixed thermal and fixed magnetic setting and testing complete all as specified and directed.
Supply and fixing outdoor type, Thermoplastic Polycarbonate IP 65 Distribution Board in accordance with IEC 60 529 (Dust Proof, Water Proof & Weatherproof) Thermoplastic Polycarbonate DB of Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing, UV Resistant, Silica and Halogen Free recyclable material.Type tasted as per IEC 61 439- 1. Total Insulated with System Voltage 415V AC, 50Hz, and 5 wires. The board/panel should be UV resistance in accordance with IEC 1439-1, clause 10.2.4:The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 ( 5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT OF DEGREE OF INGRESS PROTECTION IP 65/ IP54 IN ACCORDANCE WITH IEC 60529.The gasket should be internally embedded made of polyurethane. The manufacturer of board / panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 61439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily:Temperature Rise. Dielectric Properties. Short circuit withstand current Rated peak & short time withstand current and Rated Conditional Short Circuit Current. Effectiveness of Protective Circuits. Clearance & Creepage Distance.
(i) The contractor shall submit proposed drawing of the panel interlia mentioning make of switchgears to be incorporated alongwith name of panel manufacturer for approval of GE before manufacturing. (ii) The quoted rate is inclusive of the cost of danger notice plate of suitable size and marking of letters with PVC sheet/ Stickers such as incoming and outgoing and capacity of breakers etc. (iii) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (iv) The bottom of panel shall have minimum 45cm height from existing ground / floor level.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized MS strip of size 32x 6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 20 mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.0 mm dia thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 20 mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified
Provision of high mast light comprising of the following:- High dip galvanised mast light suitable for 08 flood light symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 gauge and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrestor spike including RCC foundation as per height of 16 mtr, complete all as specified in clause No. 19.23B of SSR 2009 Part-I and as directed by Engr-in-Charge as specified here-in-under:- High Mast Syatem:- Height of mast light- 16 Mtr No of sections-02 Material construction: S355 grade as per BS-EN10025 Base dia and top diameter (A/F) top 150 mm, Bottom: 410 mm Plate thickness and section length, top: 3 mm, Length: 5470 mm Bottom: Thickness 4 mm, Length: 10980 mm Cross section of mast - 20 side polygon Standard for galvanization as per BS EN ISO 1461 Size of opening and door at base- 1200 X 250 mm Diameter of base plate- 570 mm Thickness of base plate- 25 mm Lightening protection final: GI Single spike of length not less than 1.2 m Max wind speed : 50 m/s as per IS:875 (Part-III) Nos of foundation bolts- 08 Nos PCD of foundation bolts- 490 mm Type/diameter/length of foundation bolts- TS 600/300 mm dia/850 mm long integral power tool will be installed inside base compartment for its operation.
TRIALING CABLE: Conductor copper 5 core 4 Sqmm Insulation EPR insulated PCP sheathed Nos of circuit per mast one water proof type junction box with IP 55 protection enclouser made of cast aluminium shall be provided on the carriage assembly as required from which the inter connection to the flood light luminaries and associated control gear fixed on the carriage shall be made WINCH/POWER TOOL: Type/SWL of winch double drum, SWL 750 Kg Method of operation- Integral motor and provn of manual operation to operate the winch manually by a suitable handle and or by an external power tool complete all as directed. Motor Capacity: 1 HP No of speed: Single speed 1.5 to 1.8 m/s to avoid any high speed jerk. Non corrodible type stainless steel wire rope with centre core being of same material grade/construction AISI 316, 7/19 construction. No of ropes-two continuous without any intermediate joint between which and lantern carriage. Diameter (mm) 6 mm Breaking load capacity: 2X2350 Kg
Note: (i) Separate cable 2x2.5 sqmm copper conductor single core from LT panel to each aviation light shall be provided. (ii) Thimble shall be secured on ropes by compression splices. Note: Design of foundation based on loading of the mast shall be the responsibility of contractor. Design of foundation shall be got vetted by approved agency such as IIT/NIT and cost thereof shall be deemed to be included in rate quoted B. Two Nos aviation obstruction light with LED lamp as per Cat Part No BGAV 302 LED of Make: Bajaj or equivalent in philips/havells including provn of automated battery backup for atleast 4 hours in case of non availability of power supply, minimum size of inverter 800 VA- 01 Nos and maintenance free battery 12 V, 150 Ah-01 No with PVC enclouser trolly type for battery and inverter including provn of shelter of size 1.5MX1MX1M for protection from rain, water etc made out of 3.15 mm thick PGI sheet roof with angle and frame of 40X40X6 mm including necessary earthwork, PCC 1:2:4 type B-1 using 20 mm graded compressed by manufacturer. Make of inverter and battery- Microtech/Luminuous/Sukum/Exide.
Supply and fixing LED flood light 180 watt 230 V AC outdoor type with thermal anagement in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp coplete all as specified and dire cted by Engr-In-Charge. Make: C&S Cat Pt No.LTEF180WHPLED or equivalent in Havells/C&G
M/S WASEEM KHAN CONTRACTOR
OM TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .