Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
12 May 2026, 6:00 pmClosed
GE (AF) Tezpur
AFS Tezpur-784104
PROVN OF AC WIRING FOR AC AT NP-88, NP-87 BLDG AND REPLACEMENT OF SUBMAIN WIRING WITH COPPER WIRING AT AF STN TEZPUR
2026_MES_760053_1
8145/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
TEZPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) TEZPUR
₹97,000
Yes
2 May 2026
11 Apr 2026
14 May 2026
11 Apr 2026
12 May 2026
25 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Taking down carefully copper/ aluminium point wiring (light/fan/bell/ holder/socket or power point) inclusive of all fittings such as switches, ceiling roses, pendants, regulators, sockets, fittings etc. removing materials from site and making good to the disturbed surfaces of floors/walls/ceiling etc, complete all as specified and as directed by Engr-in-Charge. | - | Per Point | - | - |
| - | Taking down carefully aluminium sub main wiring of any type and size including fittings and fixtures, removing materials from site , complete all as specified and as directed by Engr-in-Charge. | - | RM | - | - |
| - | Disconnecting from electric circuit and taking out existing unserviceable MCB DB SPN of any number of ways including MCB etc removing materials from site, complete all as specified and as directed by Engr-in-Charge. | - | Each | - | - |
| - | Taking down ceiling fan, ceiling cable end, dismantling blades, removing fan and blades, re-fixing, complete all as specified and as directed by Engr-in-Charge. | - | Each Job | - | - |
| - | Disconnecting from electric circuit and taking out electric meter from the existing sheet metal enclosure and deposited to MES for re-fixing , complete all as specified and as directed by Engr-in-Charge. | - | Each Job | - | - |
| - | Materials and labour for concealed point wiring with 1.5 Sqmm PVC insulated and unsheathed multi-stranded FRLSH copper conductor cable 1100 volts grade, single core, drawn through and including PVC concealed conduit (medium grade) not less than 20mm size with all fittings and accessories suitable for one light / one fan/ bell point controlled by one switch including unsheathed single core stranded copper cable of size 1.5 Sqmm as earth continuity conductor connected to common earth and earthy dolly and to be terminated to sunken/pressed flush box readily available covered with outer plates/inner plates etc as per site requirement and making good to the disturbed surfaces of walls,floors etc, complete all as specified and as directed.
Note:-
1. Metal box shall be measured and paid separaely as ''Supply'' only for mounting modular switches sockets, fan regulators including testing on completeion complete all as specified and as directed.
2. Modular plate with frame shall be measured and paid for separately. | - | Per Point | - | - |
| - | All as per Item No.6 here-in-before but for one 3 Pin 5 Amps socket outlet on same board with other switch, complete all as specified and as directed. | - | Per Point | - | - |
| - | All as per Item No.6 here-in-before but for one 3 pin 5 amps switch socket out let on independent board, complete all as specified and as directed. | - | Per Point | - | - |
| - | All as per Item No.6 here-in-before but wiring with 2.5 Sqmm , PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 volts grade, single core earth continuity conductor connected to common earth dolly for one 3/5 pin 15 amps switch socket out let on independent board, complete all as specified and as directed. | - | Per Point | - | - |
| - | Materials and labour for concealed point wiring with 1.5 Sqmm PVC insulated and unsheathed multistranded FRLSH copper conductor cable 1100 volts grade, single core, drawn through and including PVC concealed conduit (medium grade) not less than 20mm size complete with all fittings and accessories suitable for one light controlled by two way switch including unsheathed single core stranded copper cable of size 1.5 Sqmm as earth continuity conductor connected to common earth and earth dolly and to be terminated to sunken/pressed flush box readily available covered with outer plates/inner plates etc as per site requirement and making good to the disturbed surfaces of walls,floors etc, complete all as specified and as directed.
Notes -
1. Metal box shall be measured and paid separaely as ''Supply'' only for mounting modular switches sockets, fan regulators etc.
2. Modular plate with frame shall be measured and paid for separately. | - | Point | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tender8145.pdf
Tender Documents • 0.91 MB
BOQ_851334.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .