| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAccepted-AOC A 31 RAJENDRA NAGAR BAREILLY UP 243122 | BAREILLY | BAREILLY | UP | 243122 | ₹6.2 Cr | L1 | Accepted-AOC Awarded since L-1 |
| 2 | L2₹6.4 Cr+₹13.2 L (2.12%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹6.4 Cr+₹13.2 L (2.12%) | L2 | Rejected-Finance Rejected Since not L-1 |
| 3 | L3₹7.2 Cr+₹99.3 L (15.9%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹7.2 Cr+₹99.3 L (15.9%) | L3 | Rejected-Finance Rejected since not L-1 |
Tender Value
₹6.4 Cr
EMD Value
₹6.5 L
Closing Date
26 Mar 2022, 6:00 pmClosed
CE (AF) ALLAHABAD
HQ CE (AF) ALLAHABAD
CONTRUCTION OF PERIMETER ROAD WITH PERIMETER LIGHTS IN TECHNICAL, DOMESTIC AREA AND SCANNERS UNITS INCLUDING CONSTRUCTION OF WATCH TOWERS CUM REST ROOM AT AF STN BAREILLY
2022_MES_499353_1
958104/E8
Open Tender
Civil Works
Lump-sum
547 days
GE (AF) BAREILLY
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE (AF) BAREILLY
₹6.5 L
Yes
26 Apr 2022
4 Jan 2022
1 Apr 2022
4 Jan 2022
26 Mar 2022
11 Mar 2022
Amount
SCHEDULE A PART I (BUILDING WORKS)
Construction of Guard rest room with watch tower of 09 mtr height -01 Unit , Guard rest room with watch tower of 11 mtr height -02 Unit and Guard rest room with watch tower of 13 mtr height -03 Unit with specifiecation completes all as specified and shown on drawings.
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II .
Sch A Part III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External water supply as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part V.
Sch A Part VI ( SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for sewage disposal as listed in Sch ‘A’ Part VI.
Sch A Part VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for Area drainage as listed in Sch ‘A’ Part VII
Sch A Part VIII (ROAD WORK )
Lump sum price worked out by the contractor for Road Work as listed in Sch ‘A’ Part VIII
Sch A Part IX (GARBAGE BIN )
Lump sum price worked out by the contractor for Garbage Bin as listed in Sch ‘A’ Part IX
Sch A Part X (DEMOLITION OF SEWAGE LINE )
Lump sum price worked out by the contractor for Demolition of Sewage line as listed in Sch ‘A’ Part X
Sch A Part XI (Miscellaneous Items of B/R and E/M)
M&L for point wiring with 2 pairs of unarmoured telephone wire with anealed copper conductor of 0.4mm ATC,drawn in and including concealed rigid PVC conduit of size 20mm including a 1.0 mm thick pressed steel sheet box with 3.0 mm thick ISI marked Phenol bonded laminated phenolic sheet cover to accomodate a RJ 11 type Telephone Socket complete with necessary cutting in brick walls / floors and making good the disturbed surface all as specified and as directed.
S&F Telepfone socket type RJ-11 on the M.S.Box cover all as specified and as directed.
S&F LED Street Light Fittings having Ingress Protection class minimum IP-65 , suitable for road lighting luminaire with high power LED and maintenance free system for capacity 20 W complete with 32 mm bore light grade GI pipe bracket (1.5m long) duly bent to shape including 2 pairs M.S. Flat (40mmx4mm) clamps, nuts, bolts, washers etc. all as specified and as directed. Make : Philips (Cat Part No : BRP022 LED 20 CW MR S1 PSU GR) Havells (Cat No. : ENDURAPEARLSL20WLED757SASYTOPCMP ) Crompton (Cat No: LSTS-20-CDL-M) or equivalent model in other makes as mentioned in particular specifications. Note : The M.S. Clamps are to be painted with 2 coats of Aluminium Paint over a coat of Red Oxide Metal Primar before fixing at different positions.
S&F Integral LED Aviation Obstruction Light of capacity 10-24 Watts suitable for 240 Volts AC 50 Hz supply with operating input voltage 100-270 Volts AC complete with short circuit and surge voltage protection and having ingress protection class IP-65(Min) comprising with aluminium housing with polycarbonate enclosure and having LED not less than 300 Nos rigidly mounted on a 300mm long GI Pipe of suitable diameter fixed on a GI Flange duly fixed on the roof of Watch Tower with anchor bolt including necessary connection from nearby electrical point with a 3 core round flexible copper cable of size 1.5 sqmm all as specified and as directed. Make : BAJAJ / MICOLUX / MATADOR or equivalent model in other makes as mentioned in particular specifications.
supply and fixing air ventilating fan 230 mm sweep Metallic body, AC, single phase, 230 volts, complete with louvers shutters and including PVC insulated 3 core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed. Make :- Usha (Model : Aeroclean) Orient (Model : HD EX Fan ) Havells (Model : Ventilair DS) Standard (Model : Refresh Air SPS) or equivalent model in other makes as mentioned in particular specifications.
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results on a 3.0mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450mm long 10mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete all as specified an directed.
M& L for brick masonry valve chamber of internal dimension 1050 mm x 1050mm x 1050mm with PCC 1:4:8 foundation, 230mm thick brick walls built in CM 1:6, PCC 1:3:6 type C-1 using 20mm graded stone aggregate coping 50mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surface(upto 150mm below ground level) including necessary excavation and earth work in any kind of soil, MS sheet cover 3.15mm thick alongwith angle iron frame of size 40x40x6mm with locking arrangement and necessary fixing materials like hinges, bolts etc (Valve chamber cover shall be opended in two halves) and painting to MS cover and M.S.angle frame work with two coats of synthetic enamel paint over one coat of red oxide primer and 2 coats of lime wash of the valve chamber both internally and externally (above GL) complete all as specified and directed.
M & L Boring of holes under PTT/Runway, road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 MPa working pressure.
Taking out serviceable bricks from the existing cable trench and stacking aside for reuse purpose all as specified and directed.
Taking out old serviceable LT cable of any size, from existing trench and stacking aside for reuse purpose all as specified and directed. Note :- Excavation and earthwork will be measured and paid seperately under respective items of the schedule of External Electric supply.
Relaying of old serviceable LT cables in new trench, connecting inside the junction box for looping purpose, all as specified and directed.
Relaying of old serviceable bricks, in new trenches,as obtained during taking out of old serviceable cable for shifting purpose
M & L for laying brick as in protection covers over cables using well brunt sub class 'B' old size bricks in trenches over sand cushioning complete all as specified and directed.
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box, having protection class IP-66 and of overall size 155mm x 210mm x 92mm (Approx) having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB. Make :- Hensel / SPELSBERG / PROTECH / ELETTRO or equivalent model in other makes as mentioned in particular specifications.
S&F three core 1100 Volt grade PVC insulated sheathed flexible round cable with 1.5 sqmm multi stranded copper conductor complete and making connection from pole box to Flood light all as specified and directed.
Supply and Fixing of tripod mounted revolving type 300 Watt LED search light, energy saving, long range with beam range 700 mtr with stand, manually operated suitable for covering horizontally (360 degree) and vertically (more than 45 degree) with provision of both locking arrangement at desired position, Ingress protection level IP 66 with cast alluminium LM6 body with air fans, powder coated body suitable to operate in 230 v 50 Hz single phase supply all as specified and as directed.. Make : KALIN / SURYA or equivalent model in other makes as mentioned in particular specifications.
M & L for Construction of Septic Tank for 10 users including necessary earth work in excavation in any type of soil , plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 , ,reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast man hole cover slab having 8 mm dia TMT bar reinforcemement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab , 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber , form work to sides and soffits, 150 mm dia SGSW pipe of type SP 1as per IS as inlet & out let pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawings & as specified.
M & L for Construction of Soakage well for 1.80 m dia( internal dia ) & 3.00m (effective depth ) including necessary excavation in earth work in any type of soil , plain cement concrete 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 in walls & honey combed brick wall , reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast cover slab having 8 mm dia TMT bar reinforced , plain cement concrete band and dwarf wall, form work to sides and soffits of RCC slab & filling with brick bats loose filling complete all as specified and shown in drawings.
M&L for 150 mm thick (compacted thickness) Wet Mix macadam, laid in two layers of 75mm each layer spread rolled and consolidated to gradient and camber as required incl. necessary lateral support and formwork, if required using crushed stone, coarse aggregate of maximum size 40mm of grading as specified type igneous rock such as granite/trap/basalt etc complete all as specified and directed.
Supply and laying Ductile iron (DI) pipe , spigot and socket type , Class K-7 , including specials suitable for size 80 mm bore complete all as specified and directed.
Deduct Schedule of Credit Rs (-)10715.00
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .