| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance S O SH RAMESH KUMAR VILLAGE PASSAR PO BALH KAWAR TEHSIL LAD BHAROL DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.0 Cr+₹9.3 L (4.90%)Admitted-Finance R O VILL P O NAIN TEHSIL BARSAR DISTT HAMIRPUR H P | HAMIRPUR | HIMACHAL PRADESH | 174304 | ₹2.0 Cr+₹9.3 L (4.90%) | L2 | Admitted-Finance |
| 3 | L3₹2.0 Cr+₹9.9 L (5.23%)Admitted-Finance | ₹2.0 Cr+₹9.9 L (5.23%) | L3 | Admitted-Finance |
| 4 | L4₹2.1 Cr+₹18.2 L (9.55%)Admitted-Finance | ₹2.1 Cr+₹18.2 L (9.55%) | L4 | Admitted-Finance |
| 5 | L5₹2.3 Cr+₹35.7 L (18.8%)Admitted-Finance | ₹2.3 Cr+₹35.7 L (18.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SB Trading company L5 | Lalit Pal L1 | SANGRAM NAIK L7 | KRP Engineering Pvt. Ltd. L6 | SPARSH MEHTA L4 | PARVEEN KUMAR L2 | puneet angra L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in foundation, trenches etc. in all kinds of soil such as pick work, jumper work, blasting work in soft / hard rock, chiselling in soft / hard including wedging out of a rock where blasting is prohibited and stacking the excavated earth up to all lifts, stacking the excavated soil up to all lead clear from the edge of excavation and then returniing the stacked soil in 15 centimeters layers when required in to plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within all leads & lifts as per entire satisfaction of Engineer- in- charge. | 787.98 | Cum | 200 ₹1,57,596 Lowest | 270 ₹2,12,754.6 | 200 ₹1,57,596 Lowest | 450 ₹3,54,591 | 300 ₹2,36,394 | 298 ₹2,34,818.04 | 225 ₹1,77,295.5 |
| 2.00 | Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 graded stone aggregate 40 mm nominal size ) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. | 12.24 | Cum | 6,000 ₹73,440 | 5,460 ₹66,830.4 Lowest | 7,000 ₹85,680 | 7,000 ₹85,680 | 5,500 ₹67,320 | 5,500 ₹67,320 | 6,250 ₹76,500 |
| 3.00 | Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded crushed stone agg. 40mm nominal size) and curing complete excluding cost of form work in:- Foundation and plinth upto all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. | 10.67 | Cum. | 7,200 ₹76,824 | 6,000 ₹64,020 Lowest | 7,000 ₹74,690 | 7,000 ₹74,690 | 6,050 ₹64,553.5 | 6,200 ₹66,154 | 6,800 ₹72,556 |
| 4.00Providing & Laying cement concrete work Grade M30 (Design Mix) but not leaner than 1 : 1.5 : 3 (1 cement : 1.5 sand : 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:- | ||||||||||
| 4.01 | Lintels, beams, girders, bressumers and cantilevers upto floor two level within all lead and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. | 8.4 | cum | 9,000 ₹75,600 | 7,500 ₹63,000 | 9,000 ₹75,600 | 8,500 ₹71,400 | 8,000 ₹67,200 | 7,100 ₹59,640 Lowest | 7,450 ₹62,580 |
| 4.02 | Suspended floors, roofs, landing and shelves and their support, balconies, beams, girders, bressumers and cantilever upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge. | 49.52 | Cum | 9,100 ₹4,50,632 | 7,500 ₹3,71,400 Lowest | 9,000 ₹4,45,680 | 8,000 ₹3,96,160 | 8,000 ₹3,96,160 | 7,500 ₹3,71,400 Lowest | 7,700 ₹3,81,304 |
| 5.00Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu- reinforcement concrete and plain concrete work in:- | ||||||||||
| 5.01 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like, Floors etc. up to any thickness complete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. | 421.21 | Sqm | 400 ₹1,68,484 | 335 ₹1,41,105.35 Lowest | 395 ₹1,66,377.95 | 450 ₹1,89,544.5 | 345 ₹1,45,317.45 | 516 ₹2,17,344.36 | 380 ₹1,60,059.8 |
| 5.02 | Beam, cantilever, girders and lintels, Sides and soffits of beam, beam haunching, cantilever, bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor complete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. | 62.7 | Sqm | 400 ₹25,080 | 290 ₹18,183 Lowest | 380 ₹23,826 | 450 ₹28,215 | 300 ₹18,810 | 590 ₹36,993 | 390 ₹24,453 |
| 5.03 | Edges of slabs and breaks in floors and walls under 20cm wide in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. | 224.4 | Rmt | 200 ₹44,880 | 95 ₹21,318 Lowest | 145 ₹32,538 | 150 ₹33,660 | 100 ₹22,440 | 128 ₹28,723.2 | 105 ₹23,562 |
Tender Value
₹2.7 Cr
EMD Value
₹3.0 L
Closing Date
9 Oct 2023, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Dharampur Bharari
CO intake chamber repair of pump house protection of sources of various schemes by providing wire crate supply and errection of pumping machinery and laying jointing and testing of rising main 100 mm dia GMS pipe
2023_HPIPH_79609_1
7898-7947 dated 30.09.2023
Open Tender
Pumps/Motors
Item Rate
180 days
Sandhole
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,500
EE Dharampur Bharari
₹3.0 L
Yes
Dharampur
18 Oct 2023
2 Oct 2023
10 Oct 2023
2 Oct 2023
9 Oct 2023
2 Oct 2023
7 Oct 2023
Amount
Excavation in foundation, trenches etc. in all kinds of soil such as pick work, jumper work, blasting work in soft / hard rock, chiselling in soft / hard including wedging out of a rock where blasting is prohibited and stacking the excavated earth up to all lifts, stacking the excavated soil up to all lead clear from the edge of excavation and then returniing the stacked soil in 15 centimeters layers when required in to plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within all leads & lifts as per entire satisfaction of Engineer- in- charge.
Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 graded stone aggregate 40 mm nominal size ) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded crushed stone agg. 40mm nominal size) and curing complete excluding cost of form work in:- Foundation and plinth upto all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge.
Providing & Laying cement concrete work Grade M30 (Design Mix) but not leaner than 1 : 1.5 : 3 (1 cement : 1.5 sand : 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
Lintels, beams, girders, bressumers and cantilevers upto floor two level within all lead and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
Suspended floors, roofs, landing and shelves and their support, balconies, beams, girders, bressumers and cantilever upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu- reinforcement concrete and plain concrete work in:-
Flat surfaces such as soffits of suspended floors, roofs, landings and the like, Floors etc. up to any thickness complete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
Beam, cantilever, girders and lintels, Sides and soffits of beam, beam haunching, cantilever, bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor complete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
Edges of slabs and breaks in floors and walls under 20cm wide in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
Providing Tor steel reinforcement for RCC work including bending binding and placing in position complete upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
Wire crates G.I. wire filled with boulders with square cut faces against the wire (wire crates to be measured and paid for seperately) in all leads and lifts as per direction and to the entire satisfaction of Engineer -in-Charge.
Wire crates made of G.I wire filled with boulders with square cut faces against the wire (boulder filling to be measured and paid for seperately) G.I. wire 5mm thick corresponding to SWG-6, 15cmx15cm mesh in all lead and lift as per direction and to the entire satisfaction of Engineer-in-Charge.
Demolition above G.L. upto floor two level including disposal of unserviceable materials within 20 metres lead and including cutting the necessary reinforcement and seperating out from RCC/RB works as per direction and to the entire satisfaction of Engineer-in-Charge.
Providing and laying no fine cement concrete 1:4 (1 cement: 4graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work in. Cement Mortar 1:4
Brick work using common burunt clay building bricks in super structure above plinth level up to floor two level in cement mortor 1:4 (1 cement : 4 sand) (2nd class brick) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
Providing and fixing steel glazed doors, windows and ventilators of standered rolled steel sections, joints mitred and welded with 16x3.15mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20mm nominal size) with wooden plugs and screws or rawl plugs and screws or with bolt and nut as required, including fixing of glass panes with glazing clips and special metals ash putty of approved make complete as per architectural drawing and direction of Engineer in-charge
Providing wood work in frames of door, window, clerestory window and other frames wrought, framed & fixed in position as per direction and to the entire satisfaction of Engineer-in-charge upto all lead and lifts. (2nd class deodar wood)
Providing and Fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 40 mm thick. (2nd class deodar wood) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
15mm thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto floor two level includong arises, internal round angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth (Cement mortar 1:4)
20mm thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto floor two level includong arises, internal round angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth (Cement mortar 1:3)
6 mm thick cement plaster to ceiling In cement mortar 1:3 (1 cement: 3 sand)
Providing and placing of horizontal layer filtering media duly graded screened washed and cleaned as specified by the Engineer-in-charge.
(a) Broken stone 75 to 50mm
( c) Bajri screened, washed and graderd from 6mm to 20mm
(b) Fine sand screened, cleaned, washed and graded effective size 20 to 40mm with uniformity co-efficient 2 to 3.
Cement concrets flooring 1:2:4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement (40 mm thick) as per direction and to the entire satisfaciton of Engineer-in-charge upto all lead and lift.
Kota stone slab flooring 20 mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. including rubbing and polishing complete 40 mm Thick as per direction and to the entire satisfaction of Engineer-in-Charge.
Providing and fixing anodized aluminium sliding door bolt anodized colour and shade with bolts and nuts screws etc. complete. as per the direction and to the entire satisfaction of Engineer-in-charge.
Providing and fixing aluminium tower bolt (barrel type) anodized transparent or dyed as per the direction and to the entire satisfaction of Engineer-in-charge .
Providing and fixing aluminium handles anodized transparent or dyed to required colour shade with necessary screws etc. Complete as per the direction and to the entire satisfaction of Engineer-in-charge.
Providing 40x3 mm iron hold fast 40 cm long including Fixing to frame with 10 cm da bolts nuts and wooden pluges and embencing in C.C. block 30x10x15 cm 1:3:6 ( 1 cement:3 sand: 6 graded stone aggregate 20 mm nominal size) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
Squared rubble masonry coursed with hard stone of approved quality in foundation and plinth including raking out joints in foundation & plinth in cement mortar 1:4 as per direction and to the entire satisfaction of Engineer-in-charge
Random rubble masonry/Polygonal rubble masornry ( uncoursed/ brought to courses) with hard stone of approved quality in foundation and plinth I/c levelling up with cement conrete 1:6:12 (1cement:6 sand :12 graded stone aggregate 20 mm nominal size ) at plinth level in cement motar 1:6 ( 1cement:6 sand)including curing complete. As per direction and to the antire satiafaction of the Engineer-in- charge in all lead and lifts.
White washing with lime on undecorated wall surface two coats to give an even shade I/c throughly brooming the surface to remove all dirt, dust, mortar, dust and other foreign matter as per direction and to the entire satisfaction of Engineer-in-charge.
Applying priming coat over new wood and wood based surfaces after and inciuding preparing the suface be thoroughly cleaning oil grease dirt and othr foreign sand papering and knotting Readymixed paint brushing wood primer pink complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge.
Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paint to give an even shade including cleaningthe surface of dirt, dust and other foreign matters sand papering and stopping with enamel paint other than white complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge.
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete.
Painting two coats (excluding priming coat) on concrete/masonry/asbestos cement/plastered surfaces under coat with readymixed paint brushing for use on floors to give an even shade including cleaning the surface of all dirt, dust and other foreign matter and sand papering as required with:Paint other then white
Providing and fixing PVC water storage tank of ISI : 12701 marked, G.I. inlet and outletconnection, 15mm nominal bore ball valve and mosquito proof PVC cover with lockingarrangement including hoisting up to all heights above ground level :-1000 litres net capacity tank Syntax make
Providing and fixing vitreous china wash down water closet (European type W.C. Pan) with integral 'P' or 'S' trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement : 1 sand) (seat and cover to be measured and paid for separately)
Providing and fixing vitrous china wash basin with single hole for pillar tap with C.I. or M.S. brackets painted white including cutting holes and making good the same but excluding fittings 550mm X 400 mm
Providing & fixing on wall face PVC (D-Plast) rain water pipes of working pressure not less than 4.5 kg/sqm including filling the joints with approved adhesive compete.75 mm dia pipes
Providing and Fixing to wall, ceilling and floor galvanised mild steel tube (MC), fitting and clamps including making good the wall, ceiling and flooring 15mm
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group-C
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. Ceiling Fan 1400 mm sweep, Category-A
Providing and fixing LED Lamp 15 W of Havells/Usha Make.
Laying, jointing and testing in trenches (to level or grade) of following dia Heavy Class GMS pipes plain ended jointed with 1% flanged & remaining 99% butt weld joints with of below diametre conforming to IS 1239-1990 (Part - I ) with latest upto date amendments of grade and wall thickness as specified below, suitable to withstand required hydraulic test pressure in randum length 4m-6m with plain ends and jointed with butt welding with electrodes as per IS 814-1991. The welding of joint to be done to make the joints leak proof (Earth work, flanged joints & butt welding joints to be mearsured and paid separately) and to entire satisfaction of the Engineer-in-Charge.The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect. (L.R.)
100mm dia Heavy Class, wall thickness = 5.4mm
Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS 6392-1971 (Latest with up to date amendments)with plain end GMS pipe in three layers on both faces to make the joint leak proof (The cost of laying of GMS pipes to be measured and paid for separtely). The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364, the thicthness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfaction of engineer in charge with in all leads and lifts.
M.S. Flange joint 100 mm dia, Flange Table-5
Providing circumferencial Butt welded joints by electrical arc welding to following dia GMS Pipes welded in requisite number of weld runs including thread cutting so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerlikon (Adore)- CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
100 mm dia.
Providing and fixing double flanged cast steel Sluice valve of 100 mm dia of Kirloskar / Leader/KSB or JSV approved make conforming to BS: 1414/API-600 Class ASA-150 including M.S. flanges as per IS 6392-1971 including welding of flanges and capable of with standing of normal seat pressure with upto date amendments including carriage within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
100mm dia with FT-5
Pumping Machinery submersible (Percolation Well) :- Supply & errection of submersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
SITE CONDITIONS:- Total Head 28.82 mtrs Discharge required 4.98 LPS each set. No. of Pump required. 2Nos 1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance of Km from The Altitude of :- The Altitude of place is 649.50 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 500 mtrs Dia of Rising main 100 mm dia. No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Supply of Direct on line (D.O.L.) Starter of reputed make i.e L&T/Siemen conforming to BIS 8544 -( Part - I) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filing suitable for 5.0 HP motor.
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 5.0 HP capacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
MCB/MCCB of 32 Amp suitable for motor of 5.0 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 80 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 80 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 2.5 sqmm or of Suitable sizes.
Supply of Kirloskar/Leaderor JSV approved make 100 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. of rising i.e. 100 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.
Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
Providing and laying delivery pipe 100 mm dia. and common header 125 mm dia GMS pipe Medium class as per IS:1239-2004 (Part-I) jointed with MS flanges of table -17 as per IS: 6392-1971 (upto a length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
Supply of suitable cable for water level guard
Supply of supporting clamps.
Supply of cable clips of required size.
Erection of all equipment from Sr. No. 46 to 58 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Pumping Machinery (LWSS Lasrana) :- Supply & errection of submersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
SITE CONDITIONS:- Total Head 18.00 mtrs Discharge required 5.47 LPS each set. No. of Pump required. 2Nos 1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance of Km from The Altitude of :- The Altitude of place is 575 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 300 mtrs Dia of Rising main 100 mm dia. No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Supply of Direct on line (D.O.L.) Starter of reputed make i.e L&T/Siemen conforming to BIS 8544 -( Part - I) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filing suitable for 5.0 HP motor.
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 5.0 HP capacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
MCB/MCCB of 32 Amp suitable for motor of 5.0 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 80 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 80 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 2.5 sqmm or of Suitable sizes.
Supply of Kirloskar/Leader or JSV approved make 100 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. of rising i.e. 100 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.
Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
Providing and laying delivery pipe 100 mm dia. and common header 125 mm dia GMS pipe Medium class as per IS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (upto a length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
Supply of suitable cable for water level guard
Supply of supporting clamps.
Supply of cable clips of required size.
Erection of all equipment from Sr. No. 61 to 73 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Pumping Machinery ( LWSS Beri Kamlah, Chej Gawalla, Beri Kothuwan Dhalara ) :- Supply & errection of submersible pump set of KSB/ Calama/ Johnston/ SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
SITE CONDITIONS:- Total Head 36.00 mtrs Discharge required 9.11 LPS each set. No. of Pump required. 2Nos 1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance of Km from The Altitude of :- The Altitude of place is 700 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 400 mtrs Dia of Rising main 100 mm dia. No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Supply of Oil immersed Star Delta Starter of reputed make i.e MEI/Kilburn conforming to BIS 8544 -( Part -II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filing suitable for 25 HP motor.
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 25 HP capacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
MCB/MCCB of 63 Amp suitable for motor of 25.00 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 80mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 80 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 10.00 sqmm or of Suitable sizes.
Supply of Kirloskar/Leader or JSV approved make 100 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. of rising i.e. 100 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.
Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
Providing and laying delivery pipe 100 mm dia. and common header 125 mm dia GMS pipe Medium class as per IS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (upto a length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
Supply of suitable cable for water level guard
Supply of supporting clamps.
Supply of cable clips of required size.
Erection of all equipment from Sr. No. 76 to 88 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Pumping Machinery (LWSS Chej Gawalla) :- Supply & errection of submersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
SITE CONDITIONS:- Total Head 24.00 mtrs Discharge required 9.00 LPS each set. No. of Pump required. 2Nos 1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance of Km from The Altitude of :- The Altitude of place is 700 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 350 mtrs Dia of Rising main 125 mm dia. No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Supply of Air brake type Star Delta Starter of reputed make i.e L&T /Crompton /MEI conforming to BIS 8544 -( Part - II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filing suitable for 12.50 HP motor.
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 12.50 HP capacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
MCB/MCCB of 63 Amp suitable for motor of 12.50 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicator lamps complete with toggle switches for individual motors conforming to IS 3452 part I & II latest with up to date amendments of 15 watts.
50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 100 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 4.0 sqmm or of Suitable sizes.
Supply of Kirloskar/Leader or JSV approved make 125 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 125 mm dia. of rising i.e. 125 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.
Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia GMS pipe Medium class as per IS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (upto a length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
Supply of suitable cable for water level guard
Supply of supporting clamps.
Supply of cable clips of required size.
Erection of all equipment from Sr. No. 91 to 103 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Pumping Machinery (LWSS Sadhoti ) :- Supply & errection of submersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
SITE CONDITIONS:- Total Head 6.00 mtrs Discharge required 3.00 LPS each set. No. of Pump required. 2Nos 1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance of Km from The Altitude of :- The Altitude of place is 809 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other --Length of R/main 20 mtrs Dia of Rising main 32 mm dia. No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Pumping Machinery (LWSS Bag) :- Supply & errection of submersible pump set of KSB/Calama/Johnston/SU/Kirloskar or JSV approved make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
SITE CONDITIONS:- Total Head 6.00 mtrs Discharge required 3.50 LPS each set. No. of Pump required. 2Nos 1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance of Km from The Altitude of :- The Altitude of place is 864 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 20 mtrs Dia of Rising main 32 mm dia. No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Centrifugal Pump (LWSS Tourkhola):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 465.00 mtrs Discharge required 6.11 LPS each set. No. of Pump required. 1.00 No set Length of R/main 1810.00 mtrs. Dia of R/main 100 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :- The Altitude of place is 1265 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 21 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.00, size equal to dia of suction pipe)
Providing double flanged Cast steel sluice valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600 (Class ASA-300, having size one step higher to delivery of pump) .
Providing double flanged Cast steel reflux valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300, having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 100 mm non return valve of Kirloskar/Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) .
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 109 to 115.01
Providing and fixing double flanged 200 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 200 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 150 mm dia -do- = 6 mtr.
(iii) Common Header 200 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 50 mm2 Min length = 20 mtrs.
(ii) Supply side: 70 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Koon Deyol):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 338.00 mtrs Discharge required 4.40 LPS each set. No. of Pump required. 1.00 No setLength of R/main 880.00 mtrs. Dia of R/main 80 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 900 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 21 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.00, size equal to dia of suction pipe)
Providing double flanged Cast steel sluice valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600 (Class ASA-300, having size one step higher to delivery of pump) .
Providing double flanged Cast steel reflux valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300, having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 100 mm non return valve of Kirloskar/Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) .
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 109 to 115.01
Providing and fixing double flanged 200 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 200 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 150 mm dia -do- = 6 mtr.
(iii) Common Header 200 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 50 mm2 Min length = 20 mtrs.
(ii) Supply side: 70 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Koon Deyol):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 450.00 mtrs Discharge required 3.50 LPS each set. No. of Pump required. 1.00 No set Length of R/main 2200.00 mtrs. Dia of R/main 65 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 930 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 100 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 100 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 100 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 9 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.00, size equal to dia of suction pipe)
Providing double flanged Cast steel sluice valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300, having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300, having by pass arrangement and size one step higher to delivery of pump). .
Providing double flanged Cast steel 65 mm non return valve of Kirloskar/Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300) . .
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 135 to 141.01
Providing and fixing double flanged 80 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 80 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 65 mm dia -do- = 6 mtr.
(iii) Common Header 80 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 10 mm2 Min length = 20 mtrs.
(ii) Supply side: 16 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Lekhrer Phannel):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 235.00 mtrs Discharge required 2.36 LPS each set. No. of Pump required. 1.00 No set Length of R/main 600.00 mtrs. Dia of R/main 65 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 1050 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 5 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS:14846-2000 with up to date amendments (Class PN-1, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 65 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300).
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 148 to 154.01
Providing and fixing double flanged 80 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 80 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 65 mm dia -do- = 6 mtr.
(iii) Common Header 80 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 4 mm2 Min length = 20 mtrs.
(ii) Supply side: 6 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Gaddidhar( Bag) Ph-1):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 230.00 mtrs Discharge required 3.50 LPS each set. No. of Pump required. 1.00 No setLength of R/main 600.00 mtrs. Dia of R/main 65 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 1100 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 5 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS:14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump)
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump)
Providing double flanged Cast steel 65 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300).
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 161 to 167.01
Providing and fixing double flanged 80 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 80 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 65 mm dia -do- = 6 mtr.
(iii) Common Header 80 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 4 mm2 Min length = 20 mtrs.
(ii) Supply side: 6 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Gaddidhar( Bag) Second Stage (Sadhoti):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 165.00 mtrs Discharge required 3.50 LPS each set. No. of Pump required. 1.00 No set Length of R/main 600.00 mtrs. Dia of R/main 32 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 1180 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 5 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1414/API-600 (Class ASA-150 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-150 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 32 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-300 )
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 174 to 180.01
Providing and fixing double flanged 40 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 40 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 32 mm dia -do- = 6 mtr.
(iii) Common Header 40 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 4 mm2 Min length = 20 mtrs.
(ii) Supply side: 6 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Gaddidhar( Bammi Nallah) Ph-2):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 390.00 mtrs Discharge required 5.00 LPS each set. No. of Pump required. 1.00 No setLength of R/main 1170.00 mtrs. Dia of R/main 65 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :- The Altitude of place is 1050 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.C.B of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 5 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1414/API-600 (Class ASA-150 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-150 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 32 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-300 )
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 174 to 180.01
Providing and fixing double flanged 40 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 40 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 32 mm dia -do- = 6 mtr.
(iii) Common Header 40 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 4 mm2 Min length = 20 mtrs.
(ii) Supply side: 6 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Gaddidhar( Bammi Nallah) Ph-2):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 432.00 mtrs Discharge required 6.50 LPS each set. No. of Pump required. 1.00 Nos setsLength of R/main 3050 mtrs. Dia of R/main 125 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :- The Altitude of place is 942 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 21 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 125 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300).
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 200 to 206.01
Providing and fixing double flanged 150 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 150 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 125 mm dia -do- = 6 mtr.
(iii) Common Header 150 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 50 mm2 Min length = 20 mtrs.
(ii) Supply side: 70 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Beri Kamlah Gadhidhar Second Stage):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 295.00 mtrs Discharge required 8.19 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 4000.00 mtrs. Dia of R/main 125 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 1380 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 21 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 125 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300)
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 213 to 219.01
Providing and fixing double flanged 150 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 150 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 125 mm dia -do- = 6 mtr.
(iii) Common Header 150 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 50 mm2 Min length = 20 mtrs.
(ii) Supply side: 70 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Kothuwan Dhalara):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 354.00 mtrs Discharge required 9.40 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 1310 mtrs. Dia of R/main 125 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery) .The Altitude of :- The Altitude of place is 1029 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts) PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 21 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 125 mm non return valve of Kirloskar / Leader/KSB /Bhel/Gled/Kilburn/Fouress/Bir (Air Valves)/Kartar/Pelican/Zoloto make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300)
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 226 to 232.01
Providing and fixing double flanged 150 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 150 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 125 mm dia -do- = 6 mtr.
(iii) Common Header 150 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 50 mm2 Min length = 20 mtrs.
(ii) Supply side: 70 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Beri Kaltri):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 375.00 mtrs Discharge required 3.00 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 1310.00 mtrs. Dia of R/main 80 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :- The Altitude of place is 862 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 125 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 125 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 125 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 125 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 11 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 80 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300)
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 239 to 245.01
Providing and fixing double flanged 100 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 100 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 80 mm dia -do- = 6 mtr.
(iii) Common Header 100 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 16 mm2 Min length = 20 mtrs.
(ii) Supply side: 25 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Dhalara From Kothuwan Old):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 265.00 mtrs Discharge required 3.00 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 2500.00 mtrs. Dia of R/main 80 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 940 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 100 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 100 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 100 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 9 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 80 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300)
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 252 to 258.01
Providing and fixing double flanged 100 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 100 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 80 mm dia -do- = 6 mtr.
(iii) Common Header 100 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 10 mm2 Min length = 20 mtrs.
(ii) Supply side: 16 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Rawara Ghanalla):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single /double /multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 209.00 mtrs Discharge required 5.40 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 2200.00 mtrs. Dia of R/main 80 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 100 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 100 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 100 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 9 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1414/API-600 (Class ASA-150 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-150 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 80 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 21 kg/cm2 as per BS:1868/API-600 (Class ASA-150)
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 265 to 271.01
Providing and fixing double flanged 100 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 100 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 80 mm dia -do- = 6 mtr.
(iii) Common Header 100 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 10 mm2 Min length = 20 mtrs.
(ii) Supply side: 16 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump (LWSS Gawalla):- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/Crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type (latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below:
SITE CONDITIONS:- Total Head 225.00 mtrs Discharge required 5.00 LPS each set. No. of Pump required. 1.00 Nos sets Length of R/main 1200.00 mtrs. Dia of R/main 65 mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road & KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 982 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 16 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 63 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
M.C.B. 63 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.C.B. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 63 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 63 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 6 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast iron sluice valve of Kirloskar / Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments (Class PN-1.00, size equal to dia of suction pipe).
Providing double flanged Cast steel sluice valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300 having size one step higher to delivery of pump).
Providing double flanged Cast steel reflux valve of Kirloskar / Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300 having by pass arrangement and size one step higher to delivery of pump).
Providing double flanged Cast steel 65 mm non return valve of Kirloskar / Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300)
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Installation of all the items appearing at Serial No. 278 to 284.01
Providing and fixing double flanged 100 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 80 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 65 mm dia -do- = 6 mtr.
(iii) Common Header 80 mm dia -do- = 6 mtr.
and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 4 mm2 Min length = 20 mtrs.
(ii) Supply side: 10 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
PARVEEN KUMAR
puneet angra
SPARSH MEHTA
SB Trading company
KRP Engineering Pvt. Ltd.
SANGRAM NAIK
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.77 MB
Form8.pdf
Tender Documents • 1.27 MB
TC.pdf
Tender Documents • 0.58 MB
BOQ_118618.xls
BOQ • 0.60 MB
Form6.pdf
Tender Documents • 0.75 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .