(A) Electrical General work in connection with Engg. work "Renovation of Community Hall & Sr. Institute under Sr. DEN/IV/KIR". & (B) Electrical General work in connection with Engg. work "Provision of Badminton Court with Cover Shed at RPF Barrack, O.T. Para, Katihar for all Staff under the jurisdiction of Sr. DEN/IVKIR".
50_2025~NFR
50_2025
Open
Works - General
6 Months
Katihar, Bihar
₹0
₹69,100
18 Dec 2025
26 Nov 2025
4 Dec 2025
1-SCHEDULE-A (Community Hall & Sr. Institute)
2-SCHEDULE-B (Badminton Court with Cover Shed at RPF Barrack,
Item Breakup - 1-SCHEDULE-A (Community Hall & Sr. Institute)
Supply, wiring, testing & commissioning of Numbers 115.00 concealed point wiring by FR PVC insulated and unsheathed 1.5 sq mm, single core multi strand copper wire with earth continuity wire by PVC insulated and unsheathed 1 sq mm , single core multi strand copper wire concealed on wall through PVC rigid conduit pipe of dia not less than 20 mm dia heavy duty including all types of joints and bends as required, complete with 6 amps flush type controlling modular switch to be mounted on modular GI inner plate and modular mounting frame of suitable module as per requirement complete to be concealed in wall as per instruction of Engineer Incharge at site. Existing wall should be cut and re-mended to original finish by contractor's own material. (a) FL Point/LED Tube Point/Wall Mounted Decorative Light Fitting Point/Wall Fan point with c/rose
(b) Lamp Point with angle holder
(c) Fan point with c/rose and 5 step fan regulator Numbers 2M
9d) Exhaust fan point with c/rose
(e) Plug point 5 pin, 6 amps on board
Supply, wiring, testing & commissioning of Numbers concealed 6/16 amps power plug point on separate board complete with modular 16 amps switch (with indicator) and 6/16 amps 3 pin combined shuttered socket to be mounted on modular GI inner plate 4M or suitable size with modular mounting frame to be concealed in wall as per instruction of Engineer Incharge at Site.
Supply, wiring, testing & commissioning of Numbers concealed plug point on separate board complete with 2 x 6 Amp modular socket and 6/10 amps modular switch to be mounted on modular GI inner plate 6M and 6M modular mounting frame with GI box to be concealed in wall as per instruction of Engineer Incharge at site. Existing wall should be cut and re-mended to original finish by contractor's own material.
Supply, fixing, connection & testing of indoor LED Numbers tube batten with 20 watt LED T8 tubular lamp with extuded aluminium body and PC diffuser complete with inbuilt driver (System wattage-20 Watt, System efficacy> 105 lm/W, Power factor 0.90) with suitable fixing arrangement as per instruction of Engineer incharge at site.
Supply and fixing of Wall mount Decorative light Numbers fitting with 1 x 7 Watt LED lamp, E27 (Jaguar JNL- CHR-WLSL55004E27 or similar), Heritage type as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers Wall Air Circulator Fan (Industrial fan), 600 mm sweep (Speed- 1440 RPM, Max. wattage-180 Watt, Air delivery > 16000 CMH, Aerodynamically designed aluminum alloy single piece blades for high air delivery> 16500 CMH, conforms to IS 2997-1964 standards) with suitable fixing arrangement on wall as per instruction of Engineer incharge at site.
Supply, fixing & testing of 400 mm sweep Electric Numbers Pedestal Type Fan and Regulator as per instruction of Engineer Incharge at Site.
Supply, fixing & testing of LED retrofit lamp 9 Numbers watt, B-22 cap as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Fixing, testing & commissioning of ceiling fan with Numbers supply & fixing of MS clamp with hook, nut, bolt, washer etc. as per instruction of Engineer incharge at site. (Fan will be supplied by Railway)
Supply, installation, testing & commissioning of Numbers 300 mm sweep (metallic) heavy duty exhaust fan, 1400 RPM complete with fixing on wall by suitable size bolts & nuts grouted on wall as per instruction of Engineer incharge at site.
Supply,installation, testing & commissioning of Numbers insect killer of dimension (L - 26 inch X W - 4.5 inch x H - 11 inch) having coverage area 550 ft with 02 nos tube of power consumption 60 watt as per instruction of Engineer incharge at site. It should be fixed with necessary clamping.
Supply & erection of earth by 80 mm dia 3 Mtr. Numbers Long (medium guage) GI earth electrode, 8 SWG GI wire, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with cement concrete plate having locking arrangement and watering pipe as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 45 watt LED street light luminaire with heat resistant glass with connecting lead (IP protection- IP 66 class-I, System efficacy >= 105 lm/w, Housing- Pressure die cast aluminium powder coated, THD<10%, p.f.>0.95, Surge protection- 5 kV) as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers 100 watt LED flood light luminaires complete with pressure die cast aluminium housing, IP 65, Luminous efficacy >= 100 lm/watt with heat sink feature, surge protection etc. including wire connection as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 120 watt energy saving, environment friendly & robust Highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy upto 150 lm/W as per instruction of Engineer Incharge at Site.
Supply and fixing of LED Post top light, 25 watt, Numbers made in die-cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection as per instruction of Engineer Incharge at Site.
Supply, wiring & testing of main wire by 2.5 sq Metre mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 concealed in wall through PVC rigid conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 4 sq mm, Metre Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 concealed in wall through PVC rigid conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, wiring & testing of main wire by 6 sq mm, Metre Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 through PVC rigid conduit pipe/polythene pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers poly carbonate/Thermoplastic cable cable junction box of size (155 x 210 x 92) mm with IP 67 grade protection with metric knock out with terminals as per instruction of Engineer incharge at site.
(a) commissioning & painting of floor mounted powder coated cubicle panel board (Modular look) of suitable size (neither big nor small) ), outdoor type with double door made of suitable size MS/GI angle 50 x 50 x 6 mm, MS/GI flat 50 x 6 mm, 14 SWG MS sheet/Powder coated CRCA sheet with provision of weather proof,rust proof,dust proof,water proof having internal rubber gasket with supply and fixing of following ACB/MCCB/Bus bar/Meter etc. (Connections to be made by copper strips, glands should be provided at cable entry and exit, components should be compartmentalized, Each compartment will be provided with the door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided for each compartment. Panel board drawing approval must be obtained with clear indication of make of items of components):-
(b) MCCB FP 200 amps, 25 kA, Ics=100% Icu
(c) MCCB FP 100 amps, 25 kA, Ics= 100% Icu
(C) MCCB FP 63 amps, 25 kA, Ics=100% Icu
(d) Copper bus bar 200 amps made of electrolytic Set grade copper consisting of 4 bars ( 3 Ph and Neutral ) ( Bus bar should have insulation cover)
(e) Digital voltmeter (0-500) amps and Digital Set ammeter (0-500) amps with s/switch and CTs
(f) LED Indication Lamp RYB
(a) Supply, installation, testing & commissioning Set of 12 way SPN Distribution Board, Flush/Surface mounting, IP 43 grade protection with copper bus bar, fully shrouded neutral bar, earth bar, cable ties, metal double door as per IS 8623 - III with supply and fixing of following RCBO/MCB's as per instruction of Engineer Incharge at Site.
(b) RCBO DP 32 Amp, 2 module Conforms to IEC Numbers 61009-1
(C) MCB DP 16-32 amps, 2 module, 10 kA, Numbers Conforms to IS/IEC 60898 - 1:2002
(d) MCB SP 6-32 amps, 1 module, 10 kA, Numbers Conforms to IS/IEC 60898 - 1:2002 KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, installation, testing & commissioning of Numbers modular power unit complete with 32 Amp mini MCB DP "C" series 3kA , 25 amps starter, 25 Amp Socket and 25 Amp plug to be mounted on 6 module GI box, 6 module combined plate concealed on wall and wiring by 6 sq mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts with earth coninuity wire by 1 sq mm copper cable Conforming to IS: 694 to be drawn through Rigid PVC conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Dismantling of existing electrical infringements if Job any.
Supply & fixing of fully automatic with auto cut off Numbers RO Potable Water Purification System as per instruction of Engineer Incharge at Site. Total 1685447.00 Item- 2 PART-B (Sr. Institute) S No. Item Description of Item Unit Qty Rate Amount No
Supply, wiring, testing & commissioning of Numbers concealed point wiring by FR PVC insulated and unsheathed 1.5 sq mm, single core multi strand copper wire with earth continuity wire by PVC insulated and unsheathed 1 sq mm , single core multi strand copper wire concealed on wall through PVC rigid conduit pipe of dia not less than 20 mm dia heavy duty including all types of joints and bends as required, complete with 6 amps flush type controlling modular switch to be mounted on modular GI inner plate and modular mounting frame of suitable module as per requirement complete to be concealed in wall as per instruction of Engineer Incharge at site. Existing wall should be cut and re-mended to original finish by contractor's own material. (a) FL Point/LED Tube Point/Recess Light Point/Mirror Light Point/Wall Mounted Decorative Light Fitting Point/Wall Fan point with c/rose
(b) Lamp Point with angle holder
(c) Fan point with c/rose and 5 step fan regulator Numbers 2M
(d) Exhaust fan point with c/rose
(e) Plug point 5 pin, 6 amps on board
Supply, wiring, testing & commissioning of Numbers concealed 6/16 amps power plug point on separate board complete with modular 16 amps switch (with indicator) and 6/16 amps 3 pin combined shuttered socket to be mounted on modular GI inner plate 4M or suitable size with modular mounting frame to be concealed in wall as per instruction of Engineer Incharge at Site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, wiring, testing & commissioning of Numbers concealed plug point on separate board complete with 2 x 6 Amp modular socket and 6/10 amps modular switch to be mounted on modular GI inner plate 6M and 6M modular mounting frame with GI box to be concealed in wall as per instruction of Engineer Incharge at site. Existing wall should be cut and re-mended to original finish by contractor's own material.
Supply, fixing, connection & testing of indoor LED Numbers tube batten with 20 watt LED T8 tubular lamp with extuded aluminium body and PC diffuser complete with inbuilt driver (System wattage-20 Watt, System efficacy> 105 lm/W, Power factor >= 0.90) with suitable fixing arrangement as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers Surface/Recessed LED luminaire with slim line CRCA sheet metal body, square type, (System wattage-18 Watt, Nominal system efficacy >=100 lm/watt) suitable for 600 x 600 mm modular ceiling as per instruction of Engineer incharge at site.
Supply, commissioning of surface mounting sleek LED mirror light 5 W or 7 W, IP 20, 1 ft version powder coated CRCA housing, high output diffuser including suitable fixing arrangement on surface as per instruction of Engineer incharge at site.
Supply and fixing of Wall mount Decorative light Numbers fitting with 1 x 7 Watt LED lamp, E27 (Jaguar JNL- CHR-WLSL55004E27 or similar), Heritage type as per instruction of Engineer Incharge at Site.
Supply, testing & fixing of wall mounted bracket Numbers fan 400 mm sweep complete with all accessories to be fixed on wall by suitable fixing arrangement including connection by 2 core, 1.5 sqmm PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers Wall Air Circulator Fan (Industrial fan), 600 mm sweep (Speed- 1440 RPM, Max. wattage-180 Watt, Air delivery > 16000 CMH, Aerodynamically designed aluminum alloy single piece blades for high air delivery> 16500 CMH, conforms to IS 2997-1964 standards) with suitable fixing arrangement on wall as per instruction of Engineer incharge at site.
Supply, fixing & testing of 400 mm sweep Electric Numbers Pedestal Type Fan and Regulator as per instruction of Engineer Incharge at Site.
Supply, fixing & testing of LED retrofit lamp 9 Numbers watt, B-22 cap as per instruction of Engineer incharge at site.
Fixing, testing & commissioning of ceiling fan with Numbers supply & fixing of MS clamp with hook, nut, bolt, washer etc. as per instruction of Engineer incharge at site. (Fan will be supplied by Railway)
Supply, installation, testing & commissioning of Numbers 300 mm sweep (metallic) heavy duty exhaust fan, 1400 RPM complete with fixing on wall by suitable size bolts & nuts grouted on wall as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply,installation, testing & commissioning of Numbers insect killer of dimension (L - 26 inch X W - 4.5 inch x H - 11 inch) having coverage area 550 ft with 02 nos tube of power consumption 60 watt as per instruction of Engineer incharge at site. It should be fixed with necessary clamping.
Supply & erection of earth by 80 mm dia 3 Mtr. Numbers Long (medium guage) GI earth electrode, 8 SWG GI wire, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with cement concrete plate having locking arrangement and watering pipe as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 45 watt LED street light luminaire with heat resistant glass with connecting lead (IP protection- IP 66 class-I, System efficacy >= 105 lm/w, Housing- Pressure die cast aluminium powder coated, THD<10%, p.f.>0.95, Surge protection- 5 kV) as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers 100 watt LED flood light luminaires complete with pressure die cast aluminium housing, IP 65, Luminous efficacy >=100 lm/watt with heat sink feature, surge protection etc. including wire connection as per instruction of Engineer Incharge at Site.
Supply and fixing of LED Post top light, 25 watt, Numbers made in die-cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection as per instruction of Engineer Incharge at Site.
Supply, wiring & testing of main wire by 2.5 sq Metre mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 concealed in wall through PVC rigid conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 4 sq mm, Metre Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 concealed in wall through PVC rigid conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 6 sq mm, Metre Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 through PVC rigid conduit pipe/polythene pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers poly carbonate/Thermoplastic cable cable junction box of size (155 x 210 x 92) mm with IP 67 grade protection with metric knock out with terminals as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
(a) commissioning & painting of floor mounted powder coated cubicle panel board (Modular look) of suitable size (neither big nor small) ), outdoor type with double door made of suitable size MS/GI angle 50 x 50 x 6 mm, MS/GI flat 50 x 6 mm, 14 SWG MS sheet/Powder coated CRCA sheet with provision of weather proof,rust proof,dust proof,water proof having internal rubber gasket with supply and fixing of following ACB/MCCB/Bus bar/Meter etc. (Connections to be made by copper strips, glands should be provided at cable entry and exit, components should be compartmentalized, Each compartment will be provided with the door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided for each compartment. Panel board drawing approval must be obtained with clear indication of make of items of components):-
(b) MCCB FP 200 amps, 25 kA, Ics=100% Icu
(c) MCCB FP 100 amps, 25 kA, Ics= 100% Icu
(c) MCCB FP 63 amps, 25 kA, Ics=100% Icu
(d) Copper bus bar 200 amps made of electrolytic Set grade copper consisting of 4 bars ( 3 Ph and Neutral ) ( Bus bar should have insulation cover)
(e) Digital voltmeter (0-500) amps and Digital Set ammeter (0-500) amps with s/switch and CTs
(f) LED Indication Lamp RYB
(a) Supply, installation, testing & commissioning Set of 12 way SPN Distribution Board, Flush/Surface mounting, IP 43 grade protection with copper bus bar, fully shrouded neutral bar, earth bar, cable ties, metal double door as per IS 8623 - III with supply and fixing of following RCBO/MCB's as per instruction of Engineer Incharge at Site.
(b) RCBO DP 32 Amp, 2 module Conforms to IEC Numbers 61009-1
(c) MCB DP 16-32 amps, 2 module, 10 kA, Numbers Conforms to IS/IEC 60898 - 1:2002
(d) MCB SP 6-32 amps, 1 module, 10 kA, Numbers Conforms to IS/IEC 60898 - 1:2002
Supply, installation, testing & commissioning of Numbers modular power unit complete with 32 Amp mini MCB DP "C" series 3kA , 25 amps starter, 25 Amp Socket and 25 Amp plug to be mounted on 6 module GI box, 6 module combined plate concealed on wall and wiring by 6 sq mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts with earth coninuity wire by 1 sq mm copper cable Conforming to IS: 694 to be drawn through Rigid PVC conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Dismantling of existing electrical infringements if Job any. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, installation, testing & commissioning of Set Inverter of 5 kVA/48 VDC, minimum 21600 VAH with 04 nos x 120 AH SMF VRLA battery and trolley as per instruction of Engineer Incharge at Site. Total 1033636.00
Item Breakup - 2-SCHEDULE-B (Badminton Court with Cover Shed at RPF Barrack, O.T. Para)
Supply, installation, testing & commissioning of Numbers swaged type GI tubular pole 9 mt long conforms to IS - 2713/1980 with following technical specification and complete with base plate and cap: - a) Length of section : - Bottom - 5 mt, Middle - 2 mt, Top - 2 mt b) Outside diameter and thickness of section : - Bottom - 114.3 x 4.50 mm, Middle - 88.9 x 4.05 mm , Top - 76.1 x 3.25 mm
Supply & testing of GI octagonal pole 6 mt long Numbers with foundation bolt, loop box of bakelite sheet with one 6A SP MCB and 16 sq mm stud type connector etc. The octagonal pole shall be hot dip galvanized in single dip. Technical specification of pole as following:- Height - 6 mt Top dia (A/F) - 70 mm Bottom dia (A/F) - 130 mm Sheet thickness - 3 mm Base plate (L x B x T) - (200 x 200 x 12) m m Foundation Bolt size (no.x dia) - 4 x 20 dia mm Pitch Circle Dia (PCD) - 200 mm Bolt length - 600 mm Projected Bolt Length - 100 mm .
Supply & fixing of 1 mtr GI Single arm bracket Numbers (header) and holder with Nut & bolt as per instruction of Engineer incharge at site.
Erection of Rail/Tubular/Octagonal pole to 1/5 th Numbers of its height with CC foundation from base block (30 cm x 30 cm x 15 cm) including digging & refilling of earth to a height of 30 cm above ground level as per drawing no.CEE/OH@47'40@FGA) in ratio 1:3:6 by cement sand & Chips 19 mm & down including excavation of earth.
Supply, installation, testing & commissioning of Numbers 150 watt LED Street Light luminaire as per instruction of Engineer Incharge at site.
Supply, installation, testing & commissioning of Numbers 100 watt LED flood light luminaires complete with pressure die cast aluminium housing, IP 65, Luminous efficacy 100 lm/watt with heat sink feature, surge protection etc. including wire connection as per instruction of Engineer Incharge at Site.
(a) Supply, installation, testing & commissioning Set of oudoor type weather proof sheded feeder pillar box of suitable size made of powder coated 14 SWG MS/CRCA sheet, angle, flat etc. The feeder pillar box four legs should be grounted on CC foundation (1:3:6). Cable entry should have PVC glands. Feeder pillar box should have double door system with locking arrangement with fixing of rubber gasket for protection of entry of dust and water alongwith supply and fixing of following MCCB as per instruction of Engineer Incharge at site.
(b) MCCB FP 100 amps, 25 kA, Ics= 100% Icu
(c) MCCB FP 63 amps, 25 kA, Ics=100% Icu
(d) Copper bus bar 100 amps made of electrolytic Set grade copper consisting of 4 bars ( 3 Ph and Neutral ) ( Bus bar should have insulation cover) KATIHAR DIVISION-ELECTRICAL/N F RLY
(a) Supply, installation, testing & commissioning Numbers of MCB FP 63 amps, C-curve, 10 kA, ISI marked, comforms to IS/IEC 60898-1:2002 as per instruction of Engineer Incharge at Site.
(b) Supply & fixing of MCB enclosure 2 way, 2 Numbers module, made of CRCA sheet steel powder coated, IP30, metal door alongwith supply & fixing of following MCB as per instruction of Engineer incharge at site.
Supply & erection of earth by 80 mm dia 3 Mtr. Numbers Long (medium guage) GI earth electrode, 8 SWG GI wire, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with cement concrete plate having locking arrangement and watering pipe as per instruction of Engineer Incharge at Site.
Supply, erection & commissioning of earth spike Numbers made of 16 mm dia 1.8 mt long GI rod & connection metal body with the earth spike rod by 6 SWG GI earth wire with nut, bolt & washer etc. as per instruction of Engineer Incharge at Site.
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway) Total 736472.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .