Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.4 L+₹1.2 L (14.8%)Rejected-Finance | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹10.2 L+₹2.1 L (25.7%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹11.1 L+₹2.9 L (35.8%)Rejected-Finance | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹16.7 L+₹8.5 L (104.7%)Rejected-Finance NEAR TRUCK UNION ADAMPUR DOABA 144102 | ADAMPUR | JALANDHAR | PUNJAB | 144102 | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
26 Nov 2020, 6:00 pmClosed
CWE Ferozepur Cantt
HQ CWE Ferozepur Cantt
CWE/FZR- /2020-21 Special Repair to Rewiring of Bldg No P-92 (Adm Block) of AD Regt at Dholewal Mil Complex under GE Ludhiana
2020_MES_390547_1
CWE/FZR-33/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ludhiana
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Ludhiana
₹42,000
Yes
15 Dec 2020
28 Oct 2020
28 Nov 2020
28 Oct 2020
26 Nov 2020
13 Nov 2020
Amount
Taking down carefully existing alumimium point wiring for light/fan/socket out let points complete with fitting and fixtures, battens, wire etc and making good the disturbed surfaces of walls and ceilings, complete all as specified.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades to store for reuse at site and making good disturbed surfaces, complete all as specified.
Fixing or hanging only ceiling fan, and connecting up including connecting of 3 core, size of wire 22/.03mm flexible copper conductor from ceiling rose or connector to fan, complete all as specified.
M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc, complete all as specified.
Taking down Exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store for reuse at site and making good disturbed surfaces, complete all as specified.
Fixing or hanging only exhaust fan, and connecting up including connecting of 3 core, size of wire 22/.03mm flexible copper conductor from ceiling rose or connector to fan, complete all as specified.
M&L for Painting of exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc, complete all as specified.
M&L Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, (surface conduit only on roof and column) medium grade of suitable size (not less than 20mm dia )duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed,stranded (Green colour) connected to common earth dolly complete all as specified for following :- (a) One light/fan point/bell controlled by one single pole one way switch.
(b) One 3 pin 5 Amp socket outlet point controlled by one switch on Independent board.
(c) One 3 pin 5 Amp socket outlet point controlled by one switch on same board.
M&L Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 2.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, (surface conduit only on roof and column) medium grade of suitable size (not less than 20mm dia )duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, sizes for mounting switch/sockets, fan regulators etc complete with and including continuous earth wire of size 2.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed,stranded (Green colour) connected to common earth dolly for 3/6 pin 15/16 amps power socket controlled by one 15/16 amps switch, complete all as specified.
S&F LED tube light fittings, single tube 20 watt, 240 volts decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly fixed to wall/ceiling etc, complete all as specified.
S&F LED tube light fittings, single tube 10 watt, 240 volts decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly fixed to wall/ceiling etc, complete all as specified.
S&F in repairs for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor cable FRLS 4x16 Sqmm single core 650/1100 V, drawn through & including rigid PVC non metallic concealed conduit (surface conduit only on roof and column) of suitable size and numbers including continuous earth wire of size 1x10 sqmm, PVC insulated and unsheathed cable copper stranded conductor (green colour) complete all as specified. NOTE:- Four runs of 16 Sqmm, one runs of 10 Sqmm of earth wire & one run of PVC conduit shall be measured as one length.
S&F in repairs for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor cable FRLS 4x10 Sqmm single core 650/1100 V, drawn through & including rigid PVC non metallic concealed conduit (surface conduit only on roof and column) of suitable size and numbers including continuous earth wire of size 1x06 sqmm, PVC insulated and unsheathed cable copper stranded conductor (green colour) complete all as specified. NOTE:-Four runs of 10 Sqmm, one runs of 6 Sqmm of earth wire & one run of PVC conduit shall be measured as one length.
S&F in repairs for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor cable FRLS 2x6 Sqmm single core 650/1100V, drawn through & including rigid PVC non metallic concealed conduit (surface conduit only on roof and column) 25 mm dia including continuous earth wire of size 1x6 sqmm, PVC insulated and unsheathed cable copper stranded conductor (green colour) complete all as specified. NOTE:-Two runs of 06 Sqmm, one run of 6 Sqmm of earth wire & one run of PVC conduit shall be measured as one length.
S&F in repairs for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor cable FRLS 2x4 Sqmm single core 650/1100V, drawn through & including rigid PVC non metallic concealed conduit (surface conduit only on roof and column) 25 mm dia including continuous earth wire of size 1x4sqmm, PVC insulated and unsheathed cable copper stranded conductor (green colour) complete all as specified. NOTE:- Two runs of 04 Sqmm, one run of 4 Sqmm of earth wire & one run of PVC conduit shall be measured as one length.
S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet,powder coated, VTPN DB with 200 Amps rated bus bar, 12 way, FP-42 protection surface mounting, 415 volts, dust and vermin proof, suitable for incorporation of MCCBs duly concealled in wall factory made and including making good distrubbed surfaces with matching colour, complete all as specified.
S&F in repair MCCB TPN 125 Amps 50 Hz 415 Volts with thermal adjustable magnetic releases with rupturing capacity 25 KA including testing, complete all as specified and as directed.
S&F in repair Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, concealed in wall, TPN DB with 200 Amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof,suitable for incorporation of MCBs duly cocealled in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified.
S&F of MCB TPN 50 Amps 50 Hz 415 Volts with rupturing capacity 10 KA including testing, complete all as specified and as directed.
S&F in repair Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, SPN DB with 200 Amps rated bus bar, 12 way, FP-42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCCBs duly cocealled in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified.
S&F in repair Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet,powder coated, SPN DB with 200 Amps rated bus bar, 8 way, FP-42 protection concealed in wall, 240 volts, dust and vermin proof, suitable for incorporation of MCCBs duly cocealled in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified.
S&F in repairs MCB, SPN, 6 to 32 Amps, 240 volts 10 KA, complete all as specified.
S&F in repairs MCB, single pole, 240 Volt, 6 to 32 Amps, 10 KA complete all as specified.
S&F Ceiling rose, surface type, backelite 65mmx50mm, 3 terminals complete all as specified.
S&F Switch, piano, flush type, single pole one way, 5 Amps, ISI marked,complete all as specified.
S&F Socket outlet, 3 pin, 5 Amp, piano flush type, ISI marked, complete all as specified.
S&F switch Socket comnination 2 in 1, outlet 3 pin, 6/16 Amp, piano flush type, ISI marked, complete all as specified.
S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size,230 volts,6 Amps, complete all as specified.
M&L Earthing complete, all as shown on electrical plate No 3 of MES schedule part-I, and as specified including the following :-(i) Galvanised steel earth plate of size 60cmsx60cmsx6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level.(ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer).(iii) 4 mm dia (8 SWG) G.I earth wire from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc.(iv) 15 mm bore light grade, GI pipe for protection to earth-strip.(v) 20mm bore, medium grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate and MS angle iron 25x25x3mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces.(vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed.
S&F as in repairs XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 95 Sqmm nominal cross section, 3.5 core, flat or circular, insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified .
S&F as in repairs XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 70 Sqmm nominal cross section, 3.5 core, flat or circular, insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified .
S&F as in repairs XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 25 Sqmm nominal cross section, 3.5 core, flat or circular, insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as specified .
S&F in repair, LED Bldg security light fitting 30 watts 6000K, energy saving & environment friendly pressure die cast aluminium housing, heat resistance toughened glass with frame, IP 66 protection with bracket (for housing street light fittings) made of GI pipe 40 mm dia light grade 1.0 mtrs long duly cutted and welded at an angle of 120 degree and fixed to wall with 50 mm X 6 mm MS clamps - 02 Nos with 16 mm dia bolts, nuts,and washers, complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan for laying of cable and getting out,compete all as specified.
Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified.
Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified.
M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified. (Excavation and earth work measured separately). Note- Punned down thickness shall be measured.
S&F in repair Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified. (Excavation and earth work measured separately).
Supply, Installing, commissioning and Testing floor mounted LT Panel factory made of size not less than (1.20m x 1.20m x 0.45m) cubical outdoor type dust and vermin proof 415 V 3 Ph 4 wire with common TPN Busbar of aluminum of suitable size, front openable double door with locking arrangement made out of CRCA/MS Sheet 3 mm thick of appropriate size with powder coated painting & including foundation angle frame of size 40x40x6mm and 4 nos of legs on angle iron 50X50X6 mm thick of upto 0.50 mtr long panel duly powder coated having insulated bus bar TPN with openable shutter on both sides (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nuts, bolts and washers from bus bar to MCCbs and legs grouted in PCC 1:2:4 type B-1 (20mm graded aggregate)powder coated and pre-treatment seven tank process including taking out old unserviceable panel complete as under with and including following accessories:- (a) Aluminium bus bar strip of capacity 400 Amps fixed on epoxy insulator-04 Nos. (b) Incoming MCCB of current rating 250 Amps with adjustable thermal release 4 pole 415 volts 36 KA repturing capacity-01 Nos. (c) Otutgoing MCCB of current rating 160 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity-01 Nos. (d) Otutgoing MCCB of current rating 100 Amps with adjustable thermal release 4 pole 415 volts 16 KA repturing capacity-02 Nos. (e) Digital voltmeter - (0-500volts) 96x96m square type-01 Nos (f) Digital ampmeter - (0-400volts) 96x96m square type with necessary CTs-01 Nos. (g) Set of phase indicator lamp R,Y,B - 01 Set
M& L Earthling as in repair complete, all as shown on electrical plate No 5 of MES schedule part-I, and as specified including the following :- (i) Galvanised steel earth plate of size 60cmsx60cmsx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.50 metre below normal ground level. (ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer). (iii) 32x6 mm dia GI earth srtrip from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc. (iv) 50 mm bore light grade, GI pipe for protection to earth-strip. (v) 20mm bore, light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate and MS angle iron 25x25x3mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces. (vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance upto 50 metre as directed.
JASSI TRADERS
UNITED ENGINEERING CORPORATION
JAY ANN CONSTRUCTION COMPANY
MALHOTRA AND ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .