| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.2 CrAccepted-AOC JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹50.2 Cr | L1 | Accepted-AOC AOC being lowest |
| 2 | L2₹55.8 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹55.8 Cr | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹56.8 CrRejected-Finance SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹56.8 Cr | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹59.3 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹59.3 Cr | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹64.4 CrRejected-Finance | ₹64.4 Cr | L5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | Rabina Enterprises Pvt Ltd L9 | M/s Matadeen Ramchandra Agarwal L7 | RAGHUSONS INFRA ENGINEERING PVT. LTD L4 | GEMINI PROMOTERS AND BUILDERS PVT. LTD. L10 | Agarwal Jagdish Construction Company Private Limited L8 | FRIZO INDIA PVT LTD L2 | vijay infraprojects pvt ltd L3 | LUMOS INFRA PVT LTD L5 | M/s godara infratech and power industries L1 | B D RAIZADA PROJCTS PVT LTD L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART IA (TO BE QUOTED BY THE CONTRACTOR) is not prepriced by MES and prepriced rates indicated as blank under col 5 signifies this fact only. Bidders shall insert their lumpsum amount of BOQ Ser item Nos. 1 to 7 in the Green coloured field under Col-6 only. Note: The quoted rates against the items under this schedule are deemed to include for the provisions contained in Scope of Work and Sch 'A' Notes. Ref Sch 'A' Notes complete before quoting these items. Structural designs and architectural/ structural drawings for structures and foundations for the buildings/ structures shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions of relevant IS Codes. | |||||||||||||
| .02Schedule ‘A’ Part IA BUILDINGS/ STRUCTURES (TO BE QUOTED BY THE CONTRACTOR) | |||||||||||||
| 1.00 | Lumpsum price worked out for Design and Construction of RCC RADAR RAMP on 'Design-Build' mode including all services as listed in Schedule ‘A’ Part IA complete all as specified in scope of work, Sch 'A' Notes, drawings, specifications and other parts of tender documents as directed. | 1 | Lumpsum | 3,07,67,064.39 ₹3.1 Cr | 7,92,00,000 ₹7.9 Cr | 2,35,00,000 ₹2.4 Cr | 6,00,00,000 ₹6 Cr | 3,50,00,000 ₹3.5 Cr | 5,00,00,000 ₹5 Cr | 5,25,00,000 ₹5.3 Cr | 6,31,53,000 ₹6.3 Cr | 3,97,00,000 ₹4.0 Cr | 8,09,90,000 ₹8.1 Cr |
| 2.00 | Lumpsum price worked out for Design and Construction of IFF TOWER on 'Design-Build' mode including all internal services as listed in Schedule ‘A’ Part IA complete all as specified in scope of work, Sch 'A' Notes, drawings, specifications and other parts of tender documents as directed. | 1 | Lumpsum | 25,11,000 ₹25.1 L | 23,40,000 ₹23.4 L | 17,00,000 ₹17 L | 20,00,000 ₹20 L | 20,00,000 ₹20 L | 17,00,000 ₹17 L | 17,21,000 ₹17.2 L | 20,35,000 ₹20.4 L | 15,00,000 ₹15 L | 29,90,000 ₹29.9 L |
| 3.00 | Lumpsum price worked out for Design and Construction of MAIN RECEIVING STATION on 'Design-Build' mode including all internal services as listed in Schedule ‘A’ Part IA complete all as specified in scope of work, Sch 'A' Notes, drawings, specifications and other parts of tender documents as directed. | 1 | Lumpsum | 49,11,000 ₹49.1 L | 56,70,000 ₹56.7 L | 45,00,000 ₹45 L | 60,00,000 ₹60 L | 64,73,000 ₹64.7 L | 45,00,000 ₹45 L | 49,21,000 ₹49.2 L | 59,40,000 ₹59.4 L | 81,00,000 ₹81 L | 89,90,000 ₹89.9 L |
| 4.00 | Lumpsum price worked out for Design and Construction of SUBSTATION on 'Design-Build' mode including all internal services as listed in Schedule ‘A’ Part IA complete all as specified in scope of work, Sch 'A' Notes, drawings, specifications and other parts of tender documents as directed. | 10 | Lumpsum | 10,00,000 ₹1 Cr | 12,60,000 ₹1.3 Cr | 8,50,000 ₹85 L | 19,00,000 ₹1.9 Cr | 21,00,000 ₹2.1 Cr | 11,00,000 ₹1.1 Cr | 16,21,000 ₹1.6 Cr | 11,70,000 ₹1.2 Cr | 15,50,000 ₹1.6 Cr | 14,49,000 ₹1.4 Cr |
| 5.00 | Lumpsum price worked out for Design and Construction of SUBSTATION PUMP HOUSE on 'Design-Build' mode including all internal services as listed in Schedule ‘A’ Part IA complete all as specified in scope of work, Sch 'A' Notes, drawings, specifications and other parts of tender documents as directed. | 2 | Lumpsum | 31,00,000 ₹62 L | 39,60,000 ₹79.2 L | 22,00,000 ₹44 L | 39,00,000 ₹78 L | 42,00,000 ₹84 L | 29,00,000 ₹58 L | 35,21,000 ₹70.4 L | 36,00,000 ₹72 L | 32,00,000 ₹64 L | 19,59,000 ₹39.2 L |
| 6.00 | Lumpsum price worked out for Design and Construction of BOREWELL PUMP HOUSE on 'Design-Build' mode including all internal services as listed in Schedule ‘A’ Part IA complete all as specified in scope of work, Sch 'A' Notes, drawings, specifications and other parts of tender documents as directed. | 2 | Lumpsum | 3,51,000 ₹7.0 L | 4,50,000 ₹9 L | 6,00,000 ₹12 L | 7,50,000 ₹15 L | 8,30,000 ₹16.6 L | 6,00,000 ₹12 L | 6,21,000 ₹12.4 L | 4,50,000 ₹9 L | 7,50,000 ₹15 L | 5,89,000 ₹11.8 L |
| 7.00 | Lumpsum price worked out for Design and Construction of MAIN PUMP HOUSE CUM FIREFIGHTING BUILDING on 'Design-Build' mode including all internal services as listed in Schedule ‘A’ Part IA complete all as specified in scope of work, Sch 'A' Notes, drawings, specifications and other parts of tender documents as directed. | 1 | Lumpsum | 1,00,00,000 ₹1 Cr | 1,04,40,000 ₹1.0 Cr | 71,00,000 ₹71 L | 1,00,00,000 ₹1 Cr | 8,00,000 ₹8 L | 9,00,000 ₹9 L | 70,21,000 ₹70.2 L | 99,18,000 ₹99.2 L | 51,00,000 ₹51 L | 1,09,00,000 ₹1.1 Cr |
| 7.01NOTE: Schedule ‘A’ Part IB to XII under Ser No. 8.00 to 19.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||||||||||
Updated dates
Tender Value
₹65.3 Cr
EMD Value
₹15 L
Closing Date
9 Dec 2025, 6:00 pmClosed
CE (AF) GANDHINAGAR
CE (AF) GANDHINAGAR Lekawada Patia, Chiloda, Gandhinagar-382042
PROVISION OF OTM INFRASTRUCTURE AND MD ACCN AT AF STATION DEESA (PH-II) DESIGNATED AS GP-I
2025_MES_734969_1
89400/E8
Open Tender
Civil Works
540 days
GE (P) (AF) DEESA
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹3,000
GE (P) (AF) Deesa
₹15 L
Yes
24 Feb 2026
13 Oct 2025
11 Dec 2025
13 Oct 2025
9 Dec 2025
4 Dec 2025
15 Oct 2025 - 21 Oct 2025
Supply and fix factory made automatic street light control panel made out of 3.15 mm thick CRCA sheet of suitable size, epoxy powder coated as per IS-8623 dust, weather and vermin proof protection class IP-54 with and including all accessories such as astronomical control switch, 3 pole power contactor, automatic control relay, pre-wired etc. fixed on fabricated angle iron channel of suitable size and grouting on floor complete all as specified and as directed and comprising the following:- (i) MCB TPN 63 Amps 10KA, 240 volt - 02 Nos ( 01 fo
Schedule ‘A’ Part IA BUILDINGS/ STRUCTURES (TO BE QUOTED BY THE CONTRACTOR)
Material and labour for 200 mm thick (compacted thickness) Granular Sub Base (GSB) stabilised using cement forming Cement Treated Sub Base (CTSB) using granite, basalt, or trap stone coarse aggregates of grade IV grading as per MoRTH, Table 400-1, stabilised using cement OPC-43 Grade cement content @ 2% (exact quantity of cement to be finalized during design mix stage), mixed in mechanical mix plant at OMC arrived during the design mix stage; deposited, spread in uniform layer with mechanical paver and levelled in layers not exceeding 200 mm thick, compacted using 8 to 12 tonne vibratory roller to achieve minimum 7 day UCS 1.5 - 3.0 Mpa desired density 98% density as per MoRTH 5th edition clause 401 complete all as specified and directed. Note: For the purpose of pricing this item, the cement content shall be considered as 2%. However actual cement content shall be worked out as per design mix and nothing extra shall be paid on this account. Minus price adjustment shall be made @ Rs 6.91 per kg in case of quantity of cement used less than @ 2% by weight of Design Mix
Material and labour for on site LLDPE septic tank for 5 users designed to carry sewage and sullage water including excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc., with uplflow filter including media complete all as specified and as directed.
Material and labour for on site LLDPE septic tank for 10 users designed to carry sewage and sullage water including excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc., with uplflow filter including media complete all as specified and as directed.
Removing and refixing of precast RCC drain, M40 grade of internal size 450 x 450 mm, each piece of drain 2 metre long with and jointed and pointed with CM (1:3) as in open drain where required complete all as specified and directed.
Supply, laying and testing of Double Wall Corrugated (DWC) high density Polyethylene (HDPE) pipes of 63mm outer dia/ 50mm internal dia and stiffness class-8 (SN-8) with ISI marked (with CML no) with and including all fittings and jointing material for sewage line laid in trenches as specified in IS 16098-2013 part-2 complete all as specified and directed. Note:- Construction method shall be strictly comiled as per clause no A-4 of Annex IA of ISA 16098 Part II.
Supply, installation, commissioning and testing of Transformer of capacity 500 KVA (for Hanger), confirming to IS 1180 (Part-1)- 2014 with latest amendments, BEE 3 star rated, Energy Efficient Level- 3, step down outdoor type complete with standard fittings, HT 11 KV 3 phase, LT 433 volts, 3 phase, 4 wire 17 position On Load tap changer of rating + 10% to -10% in steps @ 1.25% each by means On load tap changing gear (OLTC)+ Remote Tap Cubical Changer (RTCC) Panel+ Automatic Voltage Regulator transformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting and accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180 with latest policy and with the specifications given in notes below complete all as specified and as directed.
Supply and fix hot dipped galvanized CABLOFIL wire mesh cable tray of size 600 mm width x 54 mm height complying standard EN ISO 1461, manufactured with a longitudinal 'T- welded' safety edge, constructed with 50 x 100 mm mesh configuration including couplers, covers with clips and wall mounting accessories as per site requirement complete all as specified and directed. Supports, brackets or hangers, covers designed loading capacities of the brackets and the hanger torques must be tested in accordance with the standard IEC 61537.
Supply and fix horizontal double mounting siren, three phase, 3 HP, 2800 RPM, 5 km range complete with starter, necessary foundation, protection shed complete all as specified and directed.
Supply and fix differential sound siren system 8 to 10 sound with composite panel complete all as specified and directed.
Supply and lay rubber mat of size 1.0 metre x 2.0 metre x 19.0 mm thick complete all as specified and directed.
Supply only electrical rubber hand gloves suitable for 11 KV system complete all as specified and directed.
Supply and lay PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (heavy duty) with stranded copper conductor of size 16 core x 2.5 sqmm 1100 volts grade complete all as specified and directed.
Notes:- (i) Earthing is to be done infront of the Engr-in-Charge. (ii) Test results of earthing to be submitted by the contractor for all earthings. (iii) The contractor shall have to give written guarantee for maintaining earth resistance of less than 1.0 Ohm for the period of Ten (10) years after certified date of completion and shall deposit an amount of Rs. 2000/- per earthing as security deposit for a period of Ten (10) Years. (iv) Failing to maintain resistance of earthing less than 1.0 Ohm, new earthing is to be provided by the contractor without any extra cost. (v) Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surrounding area complete.
Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part-IB.
Lump sum price worked out for EXCAVAT
ION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part-II
ROAD/ PATH/ HARDSTANDING/ CULVERT
Supply and fix precast Steel Fibre Reinforced Concrete (SFRC) Manhole cover 100mm thick complete all as specified and directed.
Material and labour for providing stress absorbing membrane interlayer (SAMI) in accordance to clause 517 of MoRTH over the CTB layer with elastomeric modified binder (PMB-76-10 conforming to IS-15462-2019) @ 1.2 kg/sqm as per IRC-37-2018 and dry stone chipping of size 11.2 mm sprayed @ 0.01 cum/sqm using hydraulic chip spreader sweeping the surface for uniform spread of aggregate and rolled by pneumatic roller complete all as specified and directed.
Supply, installation, testing and commissioning of factory made Type Test Assemble (TTA) APFC Panel with MPP-H capacitor and suitable capacity MCCB as incommer, indoor type floor mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated; the panel shall be dust and vermin proof, IP 65 class protection and made of 2.0 mm CRCA MS sheet and 50 x 50 x 5 mm thick MS angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement having copper bus bar size four strips 750 Amps 415 Volts consisting of 250 KVAR with 6 steps (2 x 25 KVAR + 4 x 50 KVAR) complete all as specified and as directed. Location: Hangar
SEWAGE DISPOSAL
Note:- (i) Rate of earthwork and PCC work etc are deemed to be inclusive in this item. (ii) Design of LT Panel including components, layout, their design as per IEC-61439 duly certified by ASTA or other approved agency. (iii) OEM design & GA drawing shall be submitted to GE for approval before start the manufacture (iv) Requisite tests required as per IEC-61439 guidelines to be conducted and report shall be submitted by OEM to Garrison Engineer. Furthe
All as per item No. 45, but for 650 LPM water flow and 30 Mtr head (1W + 1S) (for Main Pump House to Pump House No 2).
Supply, installation, testing and commissioning of indoor type (IP 3X), 05 way RMU (Ring Main Unit) 11 KV, 630 Amps, 25kA-3 Sec, IP 3X SF6 insulated, One side Extensible, consisting of Two Nos (02) motorised vacuum circuit breaker (Incomer) and Three Nos (03) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIC (Configuration VVVVV+M) inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-1. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- (for Sub Station No- 8)
(d) Creation of Day wise Reports for:- (i) Consumption Patterns - Daily, Weekly, Monthly and Annually. (ii) Load Distribution Patterns on Feeders and Transformers. (iii) Efficiency of Transformers. (iv) Load balancing status etc. and submitting hard copies of Weekly Records and Parameters mentioned in above to Engr-in-Charge. (e) Personal Computer as central Server for development version of the scada software and reporting the software with following specifiaction:- Intel 8th Gen Core I5, 8 GB RAM, 1 TB HDD, Keyboard / Mouse, 21 inches LED monitor. (f) 600VA UPS including batteries for 1/2 Hr backup (g) A4 Size Monochrome Laser Printer.
AREA DRAINAGE
All as per item No. 45, but for 140 LPM water flow and 25 Mtr head (1W + 1S) (for Pump House No 1 to Stn HQ Accn Area).
All as per item No. 45, but for 360 LPM water flow and 35 Mtr head (1W + 1S) (for Pump House No 2 to MT section Area).
EXTERNAL WATER SUPPLY
Supply, laying and testing of Double Wall Corrugated (DWC) high density Polyethylene (HDPE) pipes of 160mm outer dia/ 136mm internal dia and stiffness class-8 (SN-8) with ISI marked (with CML no) with and including all fittings and jointing material for sewage line laid in trenches as specified in IS 16098-2013 part-2 complete all as specified and directed. Note:- Construction method shall be
strictly comiled as per clause no A-4 of Annex IA of ISA 16098 Part II.
Material and labour for ductile iron fittings for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc), tee pieces, single branch, "Y" junction, double branch, cross (all socket or socket and spigot), collars, restrained joint, mechanical joint, caps and plugs; 80 mm to 250 mm dia bore including cutting and jointing old/ new positions complete all as specified and directed.
arrived during the design mix stage; deposited, spread in uniform layer with mechanical paver and levelled in layers not exceeding 150 mm thick, compacted using 8 to 12 tonne vibratory roller to achieve minimum 7 day UCS 4.5 - 7.0 Mpa desired density 98% density as per MoRTH 5th edition clause 401 complete all as specified and directed. Note: For the purpose of pricing this item, the cement content shall be considered as 3%. However actual cement content shall be worked out as per design mix and nothing extra shall be paid on this account. Minus price adjustment shall be made @ Rs 6.91 per kg in case of quantity of cement used less than @ 3% by weight of Design Mix
Supply, fabrication, installation and testing of Motor Control LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, indoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection, made out of 2.0 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed and including the following accessories:-.
Supply, fixing, testing and commissioning of single headed, ISI marked, hydrant valve as per IS: 908 with 80 mm dia flanged inlet and 63 mm dia female outlet complete with gun metal cap etc. complete all as specified and as directed.
Supply, fixing, installing and commissioning of Octagonal Galvanised Iron street light pole 8 mtr long, top dia 70 mm, bottom dia 135 mm, made out of GI sheet thickness 3 mm and base plate dimensions 300 x 300 x16 mm thickness, the pole shall be galvanized as per IS 4759/ BSEN1461 standards/ housing with in built door locking arrangement for provision of terminal plate consisting terminal block suitable size of "connectwell" copper stud teriminal (provision for socket bolting)- 04 Nos for 3 Phase and neutral for incoming & out going cable connectios etc with MCB SP 5 Amps- 01 No inside and junction box complete with necessary electrical connections including 04 Nos foundation 'J' bolts of size as per manufacutrer design should be hot dipped galvanised and including ornament type decorative GI single arm manufaturer bracket fixed to pole and necessary concrete foundation 1:2:4 concrete including necessary excavation, earth work, refilling etc complete all as specfied and directed.
Supply, fixing, installing and commissioning of Octagonal Galvanised Iron street light pole 8 mtr long, top dia 70 mm, bottom dia 135 mm, made out of GI sheet thickness 3 mm and base plate dimensions 300 x 300 x16 mm thickness, the pole shall be galvanized as per IS 4759/ BSEN1461 standards/ housing with in built door locking arrangement for provision of terminal plate consisting terminal block suitable size of "connectwell" copper stud teriminal (provision for socket bolting)- 04 Nos for 3 Phase and neutral for incoming & out going cable connectios etc with MCB SP 5 Amps- 01 No inside and junction box complete with necessary electrical connections including 04 Nos foundation 'J' bolts of size as per manufacutrer design should be hot dipped galvanised and including ornament type decorative GI double arm manufaturer bracket fixed to pole and necessary concrete foundation 1:2:4 concrete including necessary excavation, earth work, refilling etc complete all as specfied and directed.
Supply, installation, testing and commissioning of electric motor driven submersible pump set suitable for lifting water from UG sump for 2500 LPM water flow and 12 metre head with AC, 3 phase, 50 Hz ,415 volts submersible motor of suitable capacity including non return valve 01 No. all as per IS: 8034:198 complete all as specified and directed (1W + 1S) (for GWSSB UG Sump to Main Pump House).
Supply, installation, testing and commissioning of centrifugal pump sets, multistage as per IS with electric motor of 20 HP, 1440-1500 RPM, 3 phase, 440 volts, 50 Hz heavy duty capacity and pumping water to a head 40 metre with discharge 1020 LPM with all necessary accessories and fittings including PVC insulated and PVC sheathed 3 core 25 sqmm copper cable from motor to starter including necessary suitable size foundation in PCC 1:2:4 type B-1 using 20mm gradeed stone aggregate; suction and delivery suitable bore pipe and mounting arrangement complete all as specified and directed (1W + 1S) (for Pump House No 1 to Single living Accn Area) comprising of the following: (a) Priming funnel with valve (b) Pressure gauge at delivery side of pump set (c) Common base frame for pump set and prime mover
Supply, installation, testing and commissioning of centrifugal pump sets, multistage as per IS with electric motor of 20 HP, 1440-1500 RPM, 3 phase, 440 volts, 50 Hz heavy duty capacity and pumping water to a head 40 metre with discharge 990 LPM with all necessary accessories and fittings including PVC insulated and PVC sheathed 3 core 25 sqmm copper cable from motor to starter including necessary suitable size foundation in PCC 1:2:4 type B-1 using 20mm gradeed stone aggregate; suction and delivery suitable bore pipe and mounting arrangement complete all as specified and directed (1W + 1S) (for Pump House No 2 to BOCC Area) comprising of the following: (a) Priming funnel with valve (b) Pressure gauge at delivery side of pump set (c) Common base frame for pump set and prime mover
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump set having cast iron casing, enclosed type dynamically balanced phosphor-bronze/ SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/ rubber type mounting and TEFC squirrel cage induction motor, suitable for operation on 3-Phase, 415 V ± 10%, 50 Hz AC supply and having IE- 3 efficiency and conforming to IS:12615: 2018 complete all as specified and directed for 657 LPM water flow and 25 Mtr head (1W + 1S) (for Main Pump House to Officers Accn Area and Pump House No 1). Note: Necessary civil work viz. foundation for placement of pump, mounting of pump accessories shall be covered in the scope of work.
Supply and fix galvanised iron fire bucket (filled with dry sand) conforming to IS 2546: 1974 round bottom type enamel painted, white inside and red outside and letters "FIRE" in black outside and handle with mounting bracket complete as specified and directed.
Supply, installation and testing of cast iron foot valve of nominal size 80 mm dia, confirming IS 4038 complete all as specified and as directed
Supply, installation and testing of cast iron foot valve of nominal size 65 mm dia, confirming IS 4038 complete all as specified and as directed
Supply, installation, commissioning and testing pressure filter-cum iron removal plant suitable for 8000 GPH complete with PCC foundation of dimension and specification as per manufacurer's instructions, including provision of one man hole with manhole cover and lifting handle, provision of inlet, outlet and washout pipes made out of heavy duty MS pipe (inlet and outlet pipe will be connected to the main water pipes) provision of butterfly valves for inlet, outlet and wash out, back wash inter-connection etc. of appropriate size conforming to a IS-210 & 1570, air release valve, pressure relief valve, sampling cock, water level indicator, pressure guage on primary and secondary sides with stop cock,100 mm dia ERW pipe and MS pipe including two coats of black bituminous paint suitable for drinking purpose, non-toxic, non-dissolving in water on the inside walls and one coat of red-oxide primer with two coats of synthetic enamel paint on the external walls complete all as specified and directed including initial filling of filter media complete all as specified with following equipments/ accessories:-
Supply, fabrication, installation and testing of Motor Control LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection, made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed and including the following accessories:-(Near GWSSB UG Sump)
Material and labour for borewell chart on acrylic sheet of size 60cm x 15cm duly marked with permanent marking including 12mm thick plywood frame, clamps for fixing on wall etc. complete all as specified and directed.
Supply, fabrication, installation and testing of Motor Control LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, indoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection, made out of 2 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed and including the following accessories:-.(For main pump house)
Supply, laying, jointing and testing of ductile iron (DI) pressure pipes, 150 mm nominal dia with spigot and socket ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329: 2000 (latest revision) and other relevant standards, with metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillar complete all as specified and directed.
Supply, installation, testing and commissioning of indoor type (IP 3X), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 25kA-3 Sec, IP 3X SF6 insulated, One side Extensible, consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Two Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M) inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- (for Sub Station No- 9)
Supply, laying, jointing and testing of ductile iron (DI) pressure pipes, 150 mm nominal dia with spigot and socket ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329: 2000 (latest revision) and other relevant standards, with metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillar complete all as specified and directed.
OUTGOING:- (a) 4 Pole MCB 16 Amps 10 KA breaking capacity 'C' curve - 01 No. (b) 3 Pole MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader links - 04 Nos. (c) Fully automatic star-delta starter (soft starter type) with suitable relay range conforming to IS -1347 (Part IV) suitable for discharge capacity 657 LPM
OUTGOING:- (a) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, fabrication, installation and testing of Motor Control LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, indoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection, made out of 2.0 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed and including the following accessories:- (for Pump House No. 2).
Supply, laying, jointing and testing of ductile iron (DI) pressure pipes, 150 mm nominal dia with spigot and socket ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329: 2000 (latest revision) and other relevant standards, with metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillar complete all as specified and directed.
OUTGOING:- (a) 4 Pole MCB 16 Amps 10 KA breaking capacity 'C' curve - 01 No. (b) 3 Pole MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader links - 04 Nos. (c) Fully automatic star-delta starter (soft starter type) with suitable relay range conforming to IS -1347 (Part IV) suitable for discharge capacity 657 LPM
OUTGOING:- (a) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader links- 03 Nos. (Outgoing) (b) MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos. (Outgoing) (c) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (d) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, fabrication, installation and testing of Motor Control LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, indoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection, made out of 2.0 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed and including the following accessories:- (for Borewell No. 1 and No. 2).
Supply, laying, jointing and testing of ductile iron (DI) pressure pipes, 150 mm nominal dia with spigot and socket ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329: 2000 (latest revision) and other relevant standards, with metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillar complete all as specified and directed.
Supply and installation of heavy duty chemical dosing system, plunger type, suitable to inject solution upto 25 LPH working pressure, 10 Kg/cm2, comprising of dosing pump coupled with 3 phase electric motor of capacity 0.50 HP, 1440 rpm assembly with agitator in one motor, agitator with stainless steel sweep blade duly FRP coated, FRP tank 150 Ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anti-corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable, made of powder coated MS fabricated box consisting of LED indicator, digital Voltmeter, single phase preventor, high voltage/ low voltage protection complete all as specified and directed.
Material and labour for development/ enlargement of trial bore by reaming from bore well in step from (a) 200mm to 350mm, (b) from 350mm to 450mm, (c) from 450mm to 550mm, suitable for lowering ERW Mild steel 250mm dia, 8 mm thick casing pipes, gravel and clay packing for the required length below the ground level complete all as specified and directed.
Supply, assembling, lowering into bore hole and fixing in position 250 mm nominal (10") bore ERW MS pipe, ISI marked as per IS 3589, of 8 mm wall thickness in random length upto 6 mtr with screwed and socketed, including necessary fittings and welding including painting both inside and outside with black bituminous paint suitable for drinking water purpose complete all as specified and directed.
Supply and fix suitable size MS bail plug, well cap, MS strip for centering of pipe etc. fitted to casing pipe, threaded and continuous welded by electric arc welding at both ends complete all as specified and directed.
Supply, filling and packing washed pea gravels of size 3 mm to 5 mm all around casing pipe and slotted pipe complete all as specified and directed. Note: Pea gravel shall be meausured and paid as per stack measurement carried out on site.
Supply and fix well cap suitable for 250 mm dia internal dia housing pipe, made out of 6 mm thick steel plate complete all as specified and directed. Note: After completion of the work, the cap shall be used to keep the tube well closed untill the pump set is installed.
Material and labour for sanitary sealing of tube well by PCC (1:2:4) type B-1 (using 20mm graded stone aggregate), of size 1000 mm x 1000 mm x 500 mm with 2 Nos. of 50 mm bore GI tubing, medium grade of required length (not less than 1.5 metre) for gravel packing, complete all as specified and as directed.
PER HOUR
Material and labour for yield testing for the tube well by suitable capacity submersible pump and motor for minimum discharging capacity of 10000 gallons per hour for at least continuous 16 hours uninterrupted run complete all as specified and directed. Note: (i) 'V' Notch and other equipment including pump set shall be arranged by the contractor at his own cost. (ii) Electricity shall be supplied by the department for yield testing as free of cost.
S & F for LED post top lantern 20 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection and electronic driver wi
Material and labour for electrologing test using suitable equipments for upto complete drilling depth of tube well before sinking/ lowering of pipes, filters etc. for arresting proper delineation of water from Govt. recognised agency/ Govt. firm qualified Hydrologist and report shall be submitted to GE/ Engineer-in-Charge for approval complete all as specified and as directed.
Supply and fix PVC insulated, PVC sheathed, submersible flat cable, ISI marked as per IS: 694/1990 with multi stranded copper conductor, 1100 volt grade of size 3 core x 25 sqmm including water proof joint to motor terminal complete all as specified and as directed.
Supply, fixing and testing of stainless steel shaft, impeller and motor body submersible pumping set with copper rotor electric driven star delta connection 415 Volts, 50 Hz for water discharge of 570 LPM at 325 metre head, submersible motor of suitable capacity including heavy duty male/ female threaded GI coupler and non-return valve all as per IS : 8034:1989 complete all as specified and directed.
Supply and fix wire rope of stainless steel, 5mm dia flexible for borewell hoisting including rop clip complete all as specified and directed.
th warranty option of 5 years from date of installation complete with all accessories fixed on GI pipe 50 mm dia including provision of 4 sq mm three core copper conductor cable multi stranded from fitting terminal to street junction box complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Notes for item Nos. 82 to 88:- (a) Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE (Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.) (b) Vacuum Circuit Breaker shall consist of the following accessories:- (i) Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display (ii) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder (iii) SF6 Gas pressure indicator on the gas tank (iv) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation (v) CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection (vi) CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering
All as per Item No. 89 above but transformer of capacity 400 KVA (for scientific lab) with the specifications given in notes below complete all as specified and as directed.
Lump sum price worked out for TARMAC/ DISPERSAL as listed in Sch 'A' Part III
Lump sum price worked out for ROAD/ PATH/ HARDSTANDING/ CULVERT as listed in Sch 'A' Part IV
Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultrasound technique and necessary machine including provision of HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed.
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A' Part V
OUTGOING:- (a) MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (d) MCCB 40 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (e) MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (f) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos. (Outgoing) (g) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply and fix OFC 12 LIU port complete all as specified and directed.
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part VI
Lump sum price worked out for EXTERNAL ELECTRIFICATION AND SCADA SYSTEM as listed in Sch 'A' Part VII
Lump sum price worked out for SMART STREET LIGHT as listed in Sch 'A' Part VIII
Lump sum price worked out for FENCING/ GATE/ COMPOUND WALL as listed in Sch 'A' Part IX
Lump sum price worked out for FIRE FIGHTING SYSTEM as listed in Sch 'A' Part X
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A' Part XI
Supply and fix cable route indicator/ marker made up of PCC block in cement concrete 1:3:6 (using 20 mm graded stone aggregrate) of size 900 x 300 x 100 mm thick with "DANGER/ 11 KV CABLE/ MES" embossing on cable route indicator/ marker including painting as per approved colour and buried 45 cm in ground including necessary earthwork (as required/ ordered at site) complete all as specified and as directed.
Supply, installation and testing of cast iron foot valve of nominal size 50 mm dia, confirming IS 4038 complete all as specified and as directed
SMART STREET LIGHT
The scope of work shall include providing and installing additional hardware/ accessories in each RMU as per site requirement. The RTU based panel shall consist of the following sub systems:- (i) 05 nos. Multi Function Energy meters with LED Display having CI 1 & inbult RS 485 communication port. (Note Multi function Energy meters to be taken wherever PT are available) Parameters to be taken:- V, A, F, PF, KW, KWH, RUNHR, Interupts, Phase Angle THD, Neutral Current, Max Demand. (ii) 01 No. RTU with follwing specifications (a) Processor Industrial grade, Communication protocols IEC 61850 & Modbus. (b) Ports 1xRJ45, 1xRS485, 1xRS232, Operating Voltage: -24VDC, Protocols:- IPsec, SNTP, SFTP. (c) Non isolated RS 485 communication port or Ethernet communication port. (d) Suitable N
Material and labour for 80mm bore column pipe made out of galvanised iron heavy grade (6 metre long of each pipe length) with welded heavy duty flanges at both ends including a coat of anti-corrosive paint complete all as specified and directed. Note: Column pipes have been designed to withstand system load comprising the weight of the pump, water and pipes with an adequate factor of safety .
Material and labour for construction of brick masonry valve pit of size 900 mm x 900 mm x 900 mm internal dimension, one brick thick wall in cement mortar 1:4 on 100 mm thick PCC 1:4:8 (using 40mm graded stone aggregate) in foundation, rendering 15mm thick (1:4) internally and externally upto 150mm below GL, providing 3.0mm thick MS sheet valve pit cover, welded with 40X5mm flat iron frame alround including provision of hinges, handle and locking arrangement and 40 x 40 x 6mm angle iron frame fixed on top of valve pit by means of holdfast 150mm long, embedded in PCC 1:2:4 (using 20mm graded stone aggregate) block of size 230 x 200 x 100 mm, applying two coats of anti-corrosive paint over a coat of red oxide zinc chrome primer after preparation of all exposed steel surfaces including necessary earthwork in soft/ loose soil complete all as specified and as directed.
Supply and fix cable route indicator/ marker made up of PCC block in cement concrete 1:3:6 (using 20 mm graded stone aggregrate) of size 900 x 300 x 100 mm thick with "DANGER/ LT 433 VOLTS CABLE/ MES or DANGER/ MES" embossing on cable route indicator/ marker including painting as per approved colour and buried 45 cm in ground including necessary earthwork (as required/ ordered at site) complete all as specified and as directed.
r incoming & 01 for outgoing) (ii) Power Contractor 63 Amps, 3 Pole 415 volts- 01 No (iii) Astronomical function time switch (suitable for Deesa, Gujarat area) - 01 No
(vi) Touch Proof Termination Kit (vii) Line PT shall be plug-in type and shall have Isolator (viii) Multifunction meter shall have Modbus RS485 port for communication (ix) 12 port (10 RJ45 & 2 FO) Ethernet switch with LIU to be provided for scada communication with DCS (x) Capacitive voltage indication fixed type system as per IE (xi) Interlocked cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable (IP3X) safety interlocked to prevent access to cable termination in live-condition (xii) GIS shall be compatible and type tested with both SF6 Gas and Green Gas (xiii) Cable covers with self interlocking mechanism between doors, earth switch, disconnector and VCB (xiv) Necessay interclocking arrangement for safety and operations (xv) One no. operating handle for manual operation and one no. manometer (xvi) Safety interlocks shall be provided as per relevant IEC/ IS standards and manufacturer's directions (xvii) Above switchgear shall confirm to all relevant IEC/ IS standards
OUTGOING:- (a) MCCB 250 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 40 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 03 Nos. (Outgoing) (d) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
(vii) Right angle boot to be provided in each module (viii) 2 x12 Volts, 26 AH Battery with Charger - 1 Set (ix) Bus VT shall be 11KV/V3/110V/V3, 20VA , Class 0.5 - 3 Nos. for metering (x) Auxiliary VT shall be 11KV/230, 500VA for AC supply input to Battery Charger (xi) Capacitive voltage indication fixed type system as per IE (xii) Interlocked cable box for front termination of the cable suitable upto 3 core 120 Sqmm, 11 KV XLPE cable (IP3X) safety interlocked to prevent access to cable termination in live-condition (xiii) Right angle boots (push on type) (xiv) Cable covers with self interlocking mechanism between doors, earth switch, disconnector and VCB (xv) Necessay interclocking arrangement for safety and operations (xvi) One no. operating handle for manual operation and one no. manometer (xvii) Safety interlocks shall be provided as per relevant IEC/ IS standards and manufacturer's directions (xviii) Above switchgear shall confirm to all relevant IEC/ IS standards
Supply, installation, testing and commissioning Outdoor type (IP 54), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec, IP54 SF6 insulated, One side Extensible, consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Two Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M) inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- (At guard room Road Junction at P2)
(xi) Top cover lifting lugs (xii) Jacking lugs (xiii) Top filter valve (xiv) Instruction plate (xv) Drain cum bottom filter valves (xvi) Earthing terminal and stud (xvii) On load tap changer with RTCC & AVR (xviii) Rating and Diagram plate (xix) Buchholz relay with alarm & trip contacts (xx) Bi directional roller wheel -04 Nos. (xxi) Marshalling box for termination of all alarm & trip controls of the transformer. (xxii) WTI (Winding temperature indicator) with alarm & trip contact (xxiii) Oil surge relay. (xxiv) Shut off valve for buchholz relay. (xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type. (xxvi) Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body. (xxvii) Necessary PCC foundation/ block masonry platform as directed by OEM. (xxviii) First filling of new and unused transformer oil, IS-335 marked.
Supply, Installation, Testing and Commissioning of 5 A Current Transformers suitable for the exsiting Load on the LT feeder pillar Pan
el complete all as specified and directed.
Supply, Installation, Testing and Commissioning 2 KVA UPS / INVERTER with Sealed Lead Acid Maintenanace free Batteries for powering the panel for a minimum of 30 minutes in case of supply failure complete all as specified and directed. UPS should have following features:- Charger:- Build in solit state stage recharge; Display:- LED Display; Audible Alarm:- Main Failure Alarm, Battery Low Alarm, UPS Warning, Fault.
Supply and fix 6 core 1.5 sqmm PVC sheathed and PVC insulated copper armoured cable complete all as specified and directed.
Supply and fix cable jointing kit for 1100 Volts grade LT UG cable for straight through joint complete with jointing material cold shrink type and accessories suitable for XLPE, armoured, aluminium conductor cable of size 3.5 core x 50 to 95 sqmm for indoor/ outdoor type complete all as specified and directed.
Supply and fix 4 core 1.5 sqmm PVC sheathed and PVC insulated copper armoured cable complete all as specified and directed.
Supply and fix 2 core 1.5 sqmm PVC sheathed and PVC insulated copper armoured cable complete all as specified and directed.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No. 1 Offr Md Accn Transformer LT Panel)
Supply and fix 4 core 1.5 sqmm PVC sheathed and PVC insulated copper armoured cable complete all as specified and directed.
Supply, Installation, Testing and Commissioning of 4 pair CAT 6 UTP armoured cable for communication complete all as specified and directed.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 2 Offr Mess & Single living Accn Transformer LT Panel)
Supply and fix 4 core 1.5 sqmm PVC sheathed and PVC insulated copper armoured cable complete all as specified and directed.
Material and labour for construction of soakage well (1.2m dia x 3.0m effective depth) including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete inclding intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/ DWC complete filled with brick bats complete as per drawing No. CEAA/TD/80 Sht Nos. 1/2 and 2/2 all as specified and as directed.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 3 Stn HQ Transformer LT panel)
Supply, fabrication, installation and testing of Motor Control LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, indoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection, made out of 2.0 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed and including the following accessories:- (for Pump House No. 1).
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders et
OUTGOING:- (a) MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (Outgoing) (b) MCCB 125 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (Outgoing) (c) MCCB 25 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 07 Nos (Outgoing) (d) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (Outgoing) (e) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
c. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 4 at SMC Area Transformer LT Panel)
Supply, Installation, Testing and Commissioning of 5 A Current Transformers suitable for the exsiting Load on the LT feeder pillar Pan
OUTGOING:- (a) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (Outgoing) (b) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 25 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos (Outgoing) (d) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 03 Nos. (Outgoing) (e) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters,
Supply and fix cable jointing kit for 1100 Volts grade LT UG cable for straight through joint complete with jointing material cold shrink type and accessories suitable for XLPE, armoured, aluminium conductor cable of size 3.5 core x 120 to 185 sqmm for indoor/ outdoor type complete all as specified and directed.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 5 at DSC Single living Transformer LT Panel)
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 6 at ATC Transformer LT Panel)
figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 7 at Scientific Lab Complex Transformer LT Panel)
Supply, Installation, Testing and Commissioning 2 KVA UPS / INVERTER with Sealed Lead Acid Maintenanace free Batteries for powering the panel for a minimum of 30 minutes in case of supply failure complete all as specified and directed. UPS should have following features:- Charger:- Build in solit state stage recharge; Display:- LED Display; Audible Alarm:- Main Failure Alarm, Battery Low Alarm, UPS Warning, Fault.
OUTGOING:- (a) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 03 Nos. (Outgoing) (b) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (d) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 8 at Hangar Transformer LT Panel)
figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carryi
figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
OUTGOING:- (a) MCCB 320 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (d) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (e) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
ng capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 9 at CEO Complex Transformer LT Panel)
Supply, Installation, Testing and Commissioning of 5 A Current Transformers suitable for the exsiting Load on the LT feeder pillar Pan
OUTGOING:- (a) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 03 Nos. (Outgoing) (b) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos. (Outgoing) (c) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 05 Nos. (Outgoing) (d) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 10 at Logistic Transformer LT Panel)
Supply, Installation, Testing and Commissioning of 5 A Current Transformers suitable for the exsiting Load on the LT feeder pillar Pan
OUTGOING:- (a) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (Outgoing) (b) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 25 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos (Outgoing) (d) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 03 Nos. (Outgoing) (e) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters,
OUTGOING:- (a) MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 03 Nos. (Outgoing) (b) MCCB 40 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos. (Outgoing) (c) MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (d) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos. (Outgoing) (e) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, Installation, Testing and Commissioning of 5 A Current Transformers suitable for the exsiting Load on the LT feeder pillar Pan
OUTGOING:- (a) MCCB 320 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (d) MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos. (Outgoing) (e) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 06 Nos. (Outgoing) (f) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
M & L for construction of brick masonary chamber for HT cable joint of size 1200 mm x 1200 mm x 800 mm internal dimension, One brick thick wall in cement mortar 1:4 on 100 mm thick PCC 1:4:8 (40mm graded aggregate) in foundation, rendering 15mm thick (1:4) internally and externally upto 150 mm below GL, providing 3.0 mm thick MS sheet valve pit cover, welded with 40 x 5mm flat iron frame alround including provision of hinges, handle and locking arrangement and 40 x 40 x 6mm angle iron frame fixed on top of valve pit by means of holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) block of size 230 x 200 x 100 mm, applying two coats of anti-corrosive paint over a coat of red oxide zinc chrome primer after preparation of all exposed to steel surfaces including necessary earth work in any type of soil complete all as specified and directed.
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 11 at 06 End Blast Pen Panel)
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 12 at Double Entry Blast Pen Transformer LT Panel)
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 13 at BOCC Complex Transformer LT Panel)
Material and labour for providing, laying and consolidating 40 mm thick dense bituminous concrete (consolidated thickness) with minimum 5.5% binder content (by using paving bitumen of grade VG-40) by weight of total mix, mixed in hot mix plant and laid by using mechanical sensor paver, rolled and compacted to required camber and gradient complete all as specified and as directed.
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A' Part XII
Supply, installation, testing and commissioning of battery charger thyristor based controlled automatic float cum boost charger and DC distribution board in a common cubicle complete all as specified and directed. The charger shall be suitable for 230 V +/- 10% single phase AC input and the output shall be suitable to float/ boost charge 24 V with 100 AH batteries and also supply load. The output shall remain constant within +/-2% for AC voltage variation 230 V and load variation 0-100%. The unit shall comprise of following:- (a) Batteries 2 Volts 100 AH - 12 Nos VRLA cells in modular form sealed maintenance free. (b) Current Rating 15 Amps. (c) Incomer MCB DP 20 A - 01 No. (d) Input working voltage: 180 -270 Volts (e) Nominal Input Voltage - 230 V , AC, 50 Hz, 1 (f) On load input power factor - > 0.8
to accomodate and including the following accessories:- (Pocket No 14 at Blast Pen 24 End Transformer LT Panel)
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 15 at STP Transformer LT Panel and Pocket No 16 at Pump House Transformer LT Panel)
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 17 at MRS Transformer LT Panel)
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves to accomodate and including the following accessories:- (Pocket No 18 at Main Guard Room Transformer LT Panel)
OUTGOING:- (a) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (d) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
(g) On load unit watt efficiencies - > 80% (h) No load losses of complete charge -< 10% (j) Ripple contents on the load (RMS) = 1% to 5% (k) Over load - 110% for 30 minutes and will give visual indication for over load condition. (l) Boost charging - 2.4 V/Cell (m) Float charging - 2.15 V/Cell (n) Float cum boost charging - Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (o) Reverse polarity - No damage will caused. A visual indication for reverse polarity will appear with an audio alarm. (p) Short circuit- MCB protection provided
Supply, Installation, Testing and Commissioning of Outdoor type, having Canopy and Double Door for weather protection, Floor Mounted RTU (Remote Terminal Unit) based Automation, Protection Panel with wireless Radio Frequency based communication. The panel should be of minimum size 1200 (H) X 1000 (W) X 300 (D) mm fabricated from 3.15 mm CRCA Sheet. Control Panel should be suitable for Remote Monitoring and Controlling of 02 Nos. Incoming VCB & 07 Nos. Outgoing VCB (Location:- Main MRS Substation) complete all as specified and directed. The Panel shall comprise of the following items:- (a) Circuit Breaker (ON & OFF status) (b) Trip Circuit Healthy (c) Spring charged (d) Auto Tripped (e) R,Y, B - indications (f) Service Position & Test Position (g) Digital value of current for all three phases for all Modules (h) Digital value of voltage from the PT (wherever PT exists)
OUTGOING:- (a) MCCB 250 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 40 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos. (Outgoing) (d) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
SCHEDULE 'A' PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicated blank under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
Material and labour for splicing work of optical fibre cable of 6/ 12 core for end connection at fibre optic distribution box complete all as specified and directed.
All as per item No. 112, but of size 200 mm width x 54 mm height.
All as per item No. 112, but of size 450 mm width x 54 mm height.
Material and labour for 150 mm thick (compacted thickness) Granular Base Course stabilised using cement forming Cement Treated Base (CTB) using granite, basalt, or trap stone coarse aggregates of grading as per MoRTH (5th revision), Table 400-4, stabilised using cement OPC-43 Grade cement content @ 3% (exact quantity of cement to be finalized during design mix stage), mixed in mechanical mix plant at OMC
OUTGOING:- (a) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 06 Nos. (Outgoing) (d) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply and fix patch cords having any type of connectors (SC/LC/ST/FC) at both ends as per site requirement complete all as specified and directed.
The scope of work shall include providing and installing Additional hardware / accessories in each RMU as per site requirement. The RTU based Panel shall consist of the follwing sub systems:- (i) 10 nos. Multi Function Energy meters with LED Display having CI 1 & inbult RS 485 communication port. (Note Multi function Energy meters to be taken wherever PT are available) Parameters to be taken:- V, A, F, PF, KW, KWH, RUNHR, Interupts, Phase Angle THD, Neutral Current, Max Demand. (ii) 01 No. RTU with following specifications:- (a) Processor Industrial grade, Communication protocols IEC 61850 & Modbus. (b) Ports 1x RJ45, 1 x RS485, 1xRS232, Operating Voltage: -24 Volts DC, Protocols:- IPsec, SNTP, SFTP. (c) Non isolated RS 485 communication port or Ethernet communication port. (d) Suitable No. of digital / analog input and outputs. (e) Programming Software based on IEC to facilitate building of custom build function blocks. (g) Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module
NOTE: Schedule ‘A’ Part IB to XII under Ser No. 8.00 to 19.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
FIRE FIGHTING SYSTEM
Supply, laying, jointing and testing of ductile iron (DI) pressure pipes, 100 mm nominal dia with spigot and socket ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329: 2000 (latest revision) and other relevant standards, with metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillar complete all as specified and directed.
Supply, Installation, Testing, Commissioning and Programming of Omni or Bi-Directional Parabolic antenna with control station to generate strong directional effect with WLAN network support having mast mounting arrangement complete all as specified and directed. Control station shall operate on license free frequency with necessary hardware at a suitable location to be connected to the central SCADA server so as to establish connectivity with every station of the network after conducting a frequency survey of the entire area of interest and identify suitable locations to mount the station hardware and the height of the antennas to establish clear line of sight either directly or by multi hop so as to be able to send data. Antenna type:- Omni and Bi Directional Parabolic antenna Degree of protection:- IP65; Mounting type:- Mast mounting, It should have a approval of Wi-Fi compliance, Environmentally Friendly; Use Period :- UNLIMITED = EFUP-e Note:- Rate quoted is deemed to be inclusive of making arrangemets of accessories such as mounting bracket and mast clips.
SQUARE METRE
Material and labour for hosebox for hose reel 20 mm dia size of 30 metre length complete with coupling branch pipe and nozzle, using MS sheet 2 mm thick complete all as specified and directed.
Material and labour for hosebox for keeping 2 Nos. hose pipe of length 15 meters each, branch pipe, nozzle, coupling etc., using MS sheet 2 mm thick complete all as specified and directed.
Supply and fix 4 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683:2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. (1 No. at entry/ exit of each floor)
Supply and fix 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683:2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. (1 No. at entry/ exit of each floor)
M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed.
INCOMING:- (a) Copper strip busbar of 600 Amps rated capacity wrapped with PVC sleeves with maintaining the colour code and provision of making holes with copper nuts, bolts and washers for cable connections including hydrograpic insulators with nuts and bolts at both ends - 04 Nos. (b) MCCB 320 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No. (Incoming) (c) LED neon indicator la
Supply and fix 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend and horn, wall mounting bracket/ floor trolley mounting accessories along with suitable signage complete all as specified and directed. (2 Nos. at entry/ exit of each floor and 1 No. in lift machine room) Notes: (i) Operating pressure: 10 to 15 bars (ii) Operating temperature : -300C to + 550C (iii) Performance criteria: Discharge time not less than 45 sec, throw not less than 4 meters (iv) Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and withstand a burst pressure of 55 bar
Supply and fix 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket/ floor trolley mounting accessories along with suitable signage complete all as specified and directed. (In parking area) Notes: (i) Test Pressure: 250 kgf/ sqcm (ii) Operating temperature : -300C to + 550C (iii) Locking pin and wire seal should be provided to indicate that the extinguisher has not been used. (iv) Every Extinguisher should be supplied with an operating manual.
SCADA SYSTEM FOR WATER SUPPLY
Supply, installation, testing and commissioning of Gateway for RTU Power Supply 24VDC, 5A, MCB, 2 Pole, DC, MCB, 125 A, 65 V, Power Mechanism: battery- based or power supply based networking: Cellular (2G/4G) RF range – 400m – 1000m (for LoRa based RTU) complete all as specified and directed with the following specifications: (i) Body Type: IP67/ IP68 Certifications: CE / FCC / CISPER Communication Protocol: Secured transmission of telemetry via MQTT / AMQP / HTTPS using TLS/ DTLS/ AES standard (ii) Data Transmission: 15 min data transmission for power-supply based RTU / 2-times a day for battery powered RTUs IoT based Edge Gateway Features: 32 MHz Ref Clock: TCXO (iii) Frequency Band: ISM Tx Out Power: 5 - 22 dBm (Based on Power input) Output: Wi-Fi, Ethernet and GSM (iv) Antenna: 5dB to 22 dB, Hardware support for precise timestamping, Hardware-acceler
ated Data Encryption Standard (DES), 3DES, Advanced Encryption Standard (AES) 128, AES 192, and AES 256 Protective Casing: IP 68 (v) Power Mechanism: Power supply or solar (with batteries) Certifications: CE / FCC / CISPER (vi) Networking: RF (e.g., LoRa) / Wi-Fi / or other networking technologies (eg., Sigfox, Zigbee) for connecting with nodes; Cellular (GSM/GPRS, 4G/LTE, 5G, NB-IoT) or Wi-Fi / Ethernet for connecting to cloud/ server (vii) Communication Protocol: Secured transmission of telemetry via MQTT / AMQP / HTTPS using TLS/DTLS/AES standards (viii) Data transmission: 15 min or continuous data transmission for power-supply based RTU / 4-hour data transmission for solar powered RTUs
Supply, installation, testing and commissioning of RTU for Bulk Flow Electro magnetic meter IoT based Control Unit: 32 MHz Ref Clock: TCXO Frequency Band: ISM complete all as specified and directed with the following specifications: (i) Tx Out Power: 5 - 22 dBm (Based on Power input) Output: Wi-Fi, Ethernet, and GSM (ii) Antenna: 5dB to 22 dBm (iii) Hardware support for precise timestamping, Hardware-accelerated Data Encryption Standard (DES), 3DES, Advanced Encryption, Standard (AES) 128, AES 192 and AES 256 Protective Casing: IP 68 (iv) Power Mechanism: Power supply or solar (with batteries) Certifications: CE / FCC / CISPER (v) Networking: RF (e.g., LoRa) / Wi-Fi / or other networking technologies (e.g., Sigfox, Zigbee) for connecting with nodes; Cellular (GSM/GPRS, 4G/LTE, 5G, NB-IoT) or Wi-Fi / Ethernet for connecting to cloud/ server
Supply, installation, testing and commissioning of RTU for Water Level Sensor IoT based Control Unit: 32 MHz Ref Clock: TCXO Frequency Band: ISM complete all as specified and directed with the following specifications: (i) Tx Out Power: 5 - 22 dBm (Based on Power input) Output: Wi-Fi, Ethernet, and GSM (ii) Antenna: 5dB to 22 dBm (iii) Hardware support for precise timestamping, Hardware-accelerated Data Encryption Standard (DES), 3DES, Advanced Encryption, Standard (AES) 128, AES 192, and AES 256 Protective Casing: IP 68 (iv) Power Mechanism: Power supply or solar (with batteries) Certifications: CE / FCC / CISPER (v) Networking: RF (e.g., LoRa) / Wi-Fi / or other networking technologies (e.g., Sigfox, Zigbee) for connecting with nodes; Cellular (GSM/GPRS, 4G/LTE, 5G, NB-IoT) or Wi-Fi / Ethernet for connecting to cloud/ server
Supply, installation, testing and commissioning of RTU for Pressure sensor IoT based Control Unit : 32 MHz Ref Clock: TCXO Frequency Band: ISM complete all as specified and directed with the following specifications: (i) Tx Out Power: 5 - 22 dBm (Based on Power input) Output: Wi-Fi, Ethernet, and GSM (ii) Antenna: 5dB to 22 dBm (iii) Hardware support for precise timestamping, Hardware-accelerated Data Encryption Standard (DES), 3DES, Advanced Encryption,Standard (AES) 128, AES 192, and AES 256 Protective Casing: IP 68 (iv) Power Mechanism: Power supply or solar (with batteries) Certifications: CE / FCC / CISPER (v) Networking: RF (e.g., LoRa) / Wi-Fi / or other networking technologies (e.g., Sigfox, Zigbee) for connecting with nodes; Cellular (GSM/GPRS, 4G/LTE, 5G, NB-IoT) or Wi-Fi / Ethernet for connecting to cloud/ server
Supply, installation, testing and commissioning of Centralised web and mobile monitoring including wifi, LAN, WAN for flow, level, pressure and RTU's complete all as specified and directed with the following specifications: (i) Application for Monitoring the Sensor based Data (ii) The Solution provider shall ensure functioning of all deployed components smoothly and collaboratively to run 24*7 basis. Platform would serve as the focal point to serve as a decision support engine for administrators in day to day operations as well as during exigency situations (iii) Onprim platform (iv) Cloud base Infrastrucutre to be provided by solutions provider (v) Should have Data integration platform (vi) GIS capabilities of the Platform and Ability to plot various field devices on GIS maps with different layers (vii) Should have built in capability to integrate and automatically trigger notifications to users (Email). The required Gateway of EMAIL will be procured by the bidder which will be paid extra as per actuals. The users shall have flexibility to add and modify the conditions to trigger the notifications (viii) Should have mechanisms for Alerts, Notifications generated by other systems and IoT devices. This will improve the efficiency of the water supply scheme (manpower, electricity, water consumption) by supporting the utility and its human resources. The alerts from different IoT can be Water level in source, alert related related to the quantity of water supplied, water quality, Non-Revenue water
(ix) Should have options to visualize geo-spatial, operational and metrics data like Maps, Graphs, KPI, Tables, etc. (x) Should provide an ability to create KPI’s, Graphs and Maps from different sources of the data Should have Data and Analytics engine (xi) Should have API repository to integrate with different systems (xii) Integrate IoT devices in to the platform (xiii) System shall generate Notification, Alert and Alarm messages that shall be visible within the Dashboard/GIS Platform and the Officer Mobile App if required (xiv) The Analytics Engine shall support multiple Data Sources. Min below standard data sources shall be supported – CSV, TSV, MS Excel , NOSQL, RDBMS (xv) Capability for Integration with enterprise
Supply, installation, testing and commissioning of Pump control unit IoT based Pump Control Unit: 32 MHz Ref Clock: TCXO; Frequency Band: ISM complete all as specified and directed with the following specifications: (i) Tx Out Power: 5 - 22 dBm (Based on Power input) Output: Wi-Fi, Ethernet, and GSM Antenna: 5dB to 22 dBm (ii) Hardware support for precise timestamping, Hardware-accelerated Data Encryption Standard (DES), 3DES, Advanced Encryption Standard (AES) 128, AES 192, and AES 256 Protective Casing: IP 68 (iii) Power Mechanism: Power supply or solar (with batteries) Certifications: CE / FCC / CISPER (iv) Networking: RF (e.g., LoRa) / Wi-Fi / or other networking technologies (eg. Sigfox, Zigbee) for connecting with nodes; Cellular (GSM/GPRS, 4G/LTE, 5G, NB-IoT) or Wi-Fi / Ethernet for connecting to cloud/ server (v) This will indicate the value of ampere, voltage, energy consumed by the pump assembly meant for supplying water to the village. Any variation beyond the prescribed limit is to be immediately analyzed and addressed to avoid any breakdown of the pumping machinery which may result in disruption of water supply.
Travelling and Logging
Supply, installation, testing and commissioning of IoT based Water Level Sensors, Principle of measurement, Hydrostatic Accuracy ±0.25%, Output Analog output: 4 - 20 mA/ RS485 (Modbus RTU) Protection Clause: IP-68 or Better Pressure Range :0-10 Bar, Operating temperature: 5 Deg C to 60 Deg C, Certifications: CE / ISO / MID / ECEN complete all as specified and directed.
Panel protection of RTU + Gateway + Sensor
Electrical and Plumbing
1 year IOT base data 2G, 4G network sim plan
4 core C
abling + wiring
Diplay Unit: 32 inch display unit to showcase web information system
Supply, installation, testing and commissioning of Electro Magnetic Flow meter sensor with one year warranty, IoT based Mechanical Flow Meter water quantity and flow measurement with paddel wheel and remote communication to cloud (server) using separate RTU Accuracy +/-2% or better over typical operating range and temperatures, minimum Class B Multi-jet Operating Conditions, Temperature -20 to 60°C / Humidity 5 to 95% non-condensing; Working pressure shall be 6/ 10/ 16 bar as per local requirement, Output Pulse output / m-Bus, Body Type Water Meter: Ip68, Communication Module: IP67 (should support field replacement of batteries if attached with flowmeter), Calibration and Testing, Calibration certification required at the time of supply (e.g., FCRI) Certifications ISO 4064 B / IS: 779:1994 / MID (Directive 2004/22/EC) / OIML R 49 Ancillaries : Enclosures etc. complete all as specified and directed.
Supply, installation, testing and commissioning of Ph IoT based Water Quality Sensors (PH) along with Performance and Test Certificates from International or National Authorized/ Notified Agency with Features: Principle: Reagent Free, No Waste-stream Amperometric Chlorine Analyzer; Response time: < 2mins (Electrode: Copper, Platinum, Gold) Output: Analog output: 4 - 20 mA Digital outputs: RS485 (Modbus RTU); Body type: Probe: IP68, PVC; Shell material - ABS thermoplastic polymer; Accuracy: Accuracy ±5%, Resolution: 0.05 mg/L; Measuring range: 0 to 10.0 mg/l complete all as specified and directed.
Supply, installation, testing and commissioning of TDS IoT based Water Quality Sensors (TDS) along with Performance and Test Certificates from International or National Authorized/ Notified Agency with Features: Principle: Reagent Free, No Waste-stream Amperometric Chlorine Analyzer; Response time: < 2mins (Electrode: Copper, Platinum, Gold) Output: Analog output: 4 - 20 mA; Digital outputs: RS485 (Modbus RTU); Body type: Probe: IP68, PVC; Shell material - ABS thermoplastic polymer; Accuracy: Accuracy ±5%, Resolution: 0.05 mg/L; Measuring range: 0 to 10.0 mg/l complete all as specified and directed.
o. of digital / analog input and outputs. (e) Programming Software based on IEC to facilitate building of custom build function blocks. (f) Protocol : Master/Slave Modbus, Expandable upto 248 I/O’s and 7 expansion module
Installation + Commisioning
INCOMING:- (a) Copper strip busbar of 1200 Amps rated capacity wrapped with PVC sleeves with maintaining the colour code and provision of making holes with copper nuts, bo
PER MONTH
OUTGOING:- (a) MCCB 250 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 03 Nos. (Outgoing) (d) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (e) MCCB 32 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos. (Outgoing) (f) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos. (Outgoing) (g) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, installation, testing and commissioning of indoor type (IP 3X), 05 way RMU (Ring Main Unit), 11 KV, 630 Amps, 25kA-3 Sec, IP 3X SF6 insulated, one side extensible, consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Four Nos (04) motorised vacuum circuit breaker (Outgoing) and Metering Panel Bus PT with Top LV, Battery and Battery charger, Ethernet switch and LIU (Configuration VVVVV+M), inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- (for Sub Station No.1)
Supply, installation, testing and commissioning of indoor type (IP 3X), Primary SF6 Gas Insulated Switchgear 11 KV, 1250 Amps, 26.30 kA for 3 Sec, GIS SF6 insulated, both side extensible, consisting of Two Nos (02) motorised vacuum circuit breaker (Incomer) and Seven Nos (07) motorised vacuum circuit breaker (Outgoing), inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-0.5. GIS should be provided with internal air insulated busbars with touch proof insulating sleeve, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete GIS must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT GIS shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the GIS to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- (for Main Receiving Station)
OUTGOING:- (a) MCCB 400 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (b) MCCB 320 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (c) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (d) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No. (Outgoing) (e) MCCB 16 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos. (Outgoing) (f) Enamelled iron danger notice plate made of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel - 01 No.
Supply, installation, testing and commissioning of indoor type (IP 3X), 04 way RMU (Ring Main Unit) 11 KV, 630 Amps, 25kA-3 Sec, IP 3X SF6 insulated, One side Extensible, consisting of Two Nos (02) motorised vacuum circuit breaker (Incomer) and Two Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVVV+M), inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-1. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- (for Sub Station No.2 & 3)
Supply, installation, testing and commissioning of indoor type (IP 3X), 04 way RMU (Ring Main Unit) 11 KV, 630 Amps, 25kA-3 Sec, IP 3X SF6 insulated, One side Extensible, consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Three Nos (03) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVVV+M), inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-1. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The out
er hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- (for Sub Station No.4 & 7)
Supply, installation, testing and commissioning of indoor type (IP 3X), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 25kA-3 Sec, IP 3X SF6 insulated, One side Extensible, consisting of Two Nos. (02) motorised vacuum circuit breaker (Incomer) and One No (01) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVVV+M), inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-1. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- (for Sub Station No.5, 6 & 10)
Supply, fabrication, installation and testing of LT Panel, factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ epoxy insulator including provision for termination with incoming and outgoing cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20mm graded stone aggregate). All extension link/ interconnection shall be insulated with heat shrinkable colour coded sleeves
SCADA SYSTEM FOR ELECTRIC SUPPLY
Supply, Installation, Testing, Commissioning and Programming of Master Control Station (SCADA Software). The scope shall include services for programming, configuration and customisation of the Smart Station Platform with respect to the Power Supply Module as per actual site conditions and requirement of the engineer complete all as specified and directed with the following specifications and components: (a) Landing Page to depict criritcal paramters viz.- Supply Voltage, Current / Load on Each Feeder, Power Factor, Frequency, Fault Indication due to Earth Fault / Short Circuit, KW, KWH, KVAH, KVARH, RUNHR, ONHR, Interupts, Phase Angle THD, Neutral Current, Max Demand, Operating Temperature and Oil Levels of Transformers etc. (b) Creation of drop down tabs to monitor the all Substations and Remote RTU Panel systems individually. (c) Creation of individual RTU Panel wise schematics and layouts for the Power Distribution system as per the actual site including display of all relevant parameters viz. - Supply Voltage, Current / Load on Each Feeder, Power Factor, Frequency, Fault Indication due to Earth Fault / Short Circuit, KW, KWH, KVAH, KVARH, RUNHR, ONHR, Interupts, Phase Angle THD, Neutral Current, Max Demand, Operating Temperature and Oil Levels of Transformers etc.
Supply, Installation, Testing and Commissioning of Outdoor type, having Canopy and Double Door for weather protection, Floor Mounted RTU (Remote Terminal Unit) based Automation, Protection Panel with wireless Radio Frequency based communication. The panel should be of minimum size 1000(H) X 950(W) X 300(D) mm fabricated from 3.15 mm CRCA Sheet. Control Panel should be suitable for Remote Monitoring and Controlling of one No. 5 Way RMU (Ring Main Unit) (Location:- Substation) complete all as specified and directed. The Panel shall comprise of the following items:- (a) Circuit Breaker (ON & OFF status) (b) Trip Circuit Healthy (c) Spring charged (d) Auto Tripped (e) R,Y, B - indications (f) Service Position & Test Position (g) Digital value of current for all three phases for all Modules (h) Digital value of voltage from the PT (wherever PT exists)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.62 MB
DRAWINGS02TO12.rar
Additional Documents • 18.56 MB
tenderdocuments.rar
Tender Documents • 6.27 MB
DRG13TO23.rar
Additional Documents • 19.06 MB
BOQ_822997.xls
BOQ • 7.47 MB
DRAWINGS24TO27.rar
Additional Documents • 13.84 MB
DRAWINGS28TO29.rar
Additional Documents • 14.11 MB
Download all tender documents and submit your bid