Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | ₹4.3 L Quoted ₹4.4 L | L1 | Accepted-AOC being L1 |
| 2 | L2₹4.8 L+₹32,645 (7.34%)Rejected-Finance | ₹4.8 L+₹32,645 (7.34%) | L2 | Rejected-Finance not being L1 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
10 Sept 2020, 6:00 pmClosed
AGE I RnD haldwani
AGE I RnD haldwani PO Arjunpur UK 263139
REPAIR TO SEWAGE SYSTEM JOINERY PLUMBING AND CERTAIN OTHER BR REPAIRS AT DIBER HALDWANI.
2020_MES_369264_1
AGE I RnD/HLD/11 OF 2020-2021
Open Tender
Civil Works
Item Rate
335 days
DIBER Haldwani
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RnD haldwani
₹10,000
Yes
27 Oct 2020
14 Aug 2020
15 Sept 2020
14 Aug 2020
10 Sept 2020
29 Aug 2020
14 Aug 2020 - 29 Aug 2020
Amount
Contract Details
Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store
S&F steel tubes medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor bore of pipes 20 mm dia pipe complete all as specified and as directed
Refixing 20 mm dia old steel tubing and connections in new or old position and removing air lock of pipe with water motor (Walls, ceiling, floors, etc complete all as specified and as directed
S&F in repairs PVC waste pipe 32 mm dia for wash hand basin complete Make -Polyplast or equivalent
S&F in repairs Plastic water closet seat cover white , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed
S&F in repairs brass chromium plated jet for pedestrial pattern water closet inculding PVC flexible pipe alongwith complete necessary fittings complete all as specified and as directed
S&F in repairs CP Hand faucet including necessary fittings complete all as specified and as directed
S&F in repairs valve less syphonic action type, PVC low level flushing cistern 10 liter capacity, white, with inlet, ball valve, flot and handle including Steel brackets complete all as specified and directed.
S&F in repairas PVC low level flushing cistern kit complete all as specified and directed
Fixing only in repair steel Sinks kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe complete all as specified and as directed
Fixing only in repair glass shelf assembly complete all as specified and as directed
Fixing only in repair C P towel rail towel750 mm longcomplete all as specified and as directed
S&F in repiars Bib taps long body, Chromium plated (fency type), with crutch or butterfly handle screwed down, screwed for 15 mm bore iron pipe or brass ferrule , complete all as specified and directed
S&F in repair brass spindle of any size complete all as specified and directed
S&F in repiars pillar taps cast copper alloy with capstan head Chromium plated (fency type), screwed down high pressure with or without lettered Hot or cold with long screwed shank and fly nuts screwed for 15 mm bore iron pipe complete all as specified and directed
Fixing only in repair PVC Pillar tap complete all as specified and as directed
S&F in repairs brass CP mixer fancy type for wash hand basin for mixing hot & cold water screwed down for 15 mm iron pipe and fixed omplete all as specified and directed complete all as specified and directed
S&F in repairs brass CP wall mixer fancy type for mixing hot & cold water screwed down for 15 mm iron pipe and fixed omplete all as specified and directed complete all as specified and directed
Supply and fixing in repairs 15 mm bore angle cock, Chromium plated (fency type) with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handle heavy body with adjustable wall flange complete all as specified and directed
Fixing only in repair PVC stop cock 15mm/20mm dia complete all as specified and as directed
S&F in repairs CP brass shower rose with or without swivel joints of size 125mm dia fitted to steel pipe complete all specified and as directed
S&F in repair mild steel powder coated pelmet rods 25mm inculding 02 Nos of brackets for each set complele all as specified and directed,
S&F in repairs PVC connections 45cm long 15 mm bore with two Nos brass check nut and washer complete all as specified and directed.
S&F in repairs PVC connections 60 cm long 15 mm bore with two Nos brass check nut and washer complete all as specified and directed
S&F in repairs aluminium anodized 150 mm long barrel tower bolt of extruded section and fixed complete all as specified and directed
S&F in repair Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor over all length cover 150mm comp
S&F in repairss 20mm dia Ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed fixed complete all as specified and directed
S&F in repairss 15 mm dia Ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed fixed complete all as specified and directed
Dismantling water storage tank capacity exc 500 ltr but n exc 1000 ltr
S&F in repair rotational moulded polythene water storage tank ( Cylindrical vertical with closed top) hoisted and in fixed in position 500ltrs capacity including complete fittings all as directed
S&F in repair rotational moulded polythene water storage tank ( Cylindrical vertical with closed top) hoisted and in fixed in position 1000 ltrs capacity including complete fittings all as directed
S&F in repair PVC water tank cover for PVC water tank capacity not exc 1000 ltr including complete fittings all as directed
Disconneting the water supply to existing over head tank of capacity 500 ltr , washing , cleaning and removing scales, silt or dirt from the tank and refixing the same in position including washing internal surface of tank with the help of bleaching powder and also including necessary replcement of float valve , tee unit etc complete all as specified and directed
Disconneting the water supply to existing over head tank of capacity 1000 ltr , washing , cleaning and removing scales, silt or dirt from the tank and refixing the same in position including washing internal surface of tank with the help of bleaching powder and also including necessary replcement of float valve , tee unit etc complete all as specified and directed
S&F in repairs cast iron body,door closer hydraulically regulated, designation No 3 , universal type, suitable for door shutters complete all as specified and directed
Taking down wooden shutter of exceeding 1 sqm and not exc 2 sqm each and refifixing in the same opering after necessary repair including easing, nailing in wooden/wire mess and etc complete all as specified and directed
Taking down aluminium shutter of exceeding 1 sqm and not exc 2 sqm each and refifixing in the same opering after necessary repair including easing, rubber beading , glass /aluminium pannels fixinng in postion and etc complete all as specified and directed
S&F in repair 5mm thick 100mm wide floor door rubber sealing complete all as specified and directed
S&F in repair 5mm thick 75mm wide floor door rubber sealing complete all as specified and directed
S&F in repairs brass mortice lock of any size 4 levers complete all as specified and directed
S&F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
S&F in repairs galvanized mild steel wire cloth 0.56 mm nominal dia of wire & average width of aperture 1.18 mm fixed with tinned tacks of galvanized wire staples complete all as specified and as directed
M & L for cleaning of P/S trap of WC/IWC etc. by removing all blockage of any description in any situation in the system, and removal of sludge in semi solid state or liquid state, by manually or by pressure pump including removal of sludge to a distance exc 1.5 Km but n.exc 2 Km out of MOD land and buried into ground by digging pits complete all as specified & directed.
M & L for cleaning of Nahani /floor trap of Bath /Kitchen/Urinal/washbasin by removing all blockage of any description in any situation in the system complete by manually or by pressure pump including removal of sludge to a distance exc 1.5 Km but n.exc 2 Km out of MOD land and buried into ground by digging pits complete all as specified & directed.
M & L for cleaning of gully trap of Bath /Kitchen/Urinal/washbasin including small chamber for EWC and IWC by removing all blockage of any description in any situation in the system complete by manually or by pressure pump including removal of sludge to a distance exc 1.5 Km but n.exc 2 Km out of MOD land and buried into ground by digging pits complete all as specified & directed.
M & L for cleaning of downward pipe of any size and any description of Bath /Kitchen/Urinal/EWC/IWC/Rain water pipe by removing all blockage of any description in any situation in the system complete by manually or by pressure pump including removal of sludge to a distance exc 1.5 Km but n.exc 2 Km out of MOD land and buried into ground by digging pits complete all as specified & directed.
M & L for cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed.
M & L for cleaning of sewage pipe line from gully trap to 1st manhole and then upto the final drop into the septic tanks and soak well/cess pool (except intermediate manholes) by removing all blockage of any description in any situation in the system complete any dia of pipe and any depth by rodding, manually or by using pressure pump completely and removal of sludge to a distance exc 1.5 Km and n.exc 2 Km out of MOD land complete all as specified & directed.
M & L for taking up existing cover of manholes of any type any size and any depth dewatering and cleaning of manholes by removing sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 Km but n.exc 2 Km out of MOD land and burried into ground by digging pits of suitable sizes covering these pits with excavated earth properly as directed, and placing the covers of Manholes in position complete all as specified and directed. Notes :-(I) Excavation and earth work of pits as required at site in any type of soil, removal and placing of manhole /septic tank cover in same position and flushing of manholes,cleaning with clean water are deemed to be included in the rates quoted by the contractor. (ii)Sale of waters from septic tank/soak well/manholes to nearby farmers is not permitted.
M & L for taking up existing cover of septic tank of any type/size/ capacity dewatering and removing sludge in semi solid state or liquid state by manually or by pressure pump after emptying the sewage/ waste water including removal of sludge to a distance exc 1.5 Km but n.exc 5 Km out of MOD land and buried into ground by digging pits of suitable sizes covering these pits with excavated earth properly as directed, and placing the covers of septic tank in position complete all as specified and directed.Notes :-(I) Excavation and earth work of pits as required at site in any type of soil, removal and placing of manhole /septic tank cover in same position and flushing of manholes,cleaning of septic tank, bed of filter bed, inlet & outlet pipe of tank/filter bed, perforted hole of pipe , channels etc. with clean water are deemed to be included in the rates quoted by the contractor. (ii) Qty shall be measured as per size of tank and depth with the help of bamboo before commencement and after cleaning. (iii)Sale of waters from septic tank/soak well/manholes to nearby farmers is not permitted.
Puncturing existing sewage line of any dia and description for cleaning blockage including necessary repair & earth work complete all as specified and directed.
Demolition of brick work or stone boulder masonery built in cement morter including all quoins,arches.pillars etc all as directed and as specified
Demolition of reinforced in ground floors and pavings not exceeding 15cm thick( above or below ground level )
Excavation in trenches nexc 1.5m wide and nexc 1.5 m in depth for foundation etc or for shafts wells, manholes nexc 10 sqm on plan and nexc 1.5 m in depth and getting out in harddense soil all as specified and as directed
M & L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified and directed.
M & L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius using old size bricks built in CM 1:4 complete all as specified and directed.
M & L for rendering 15 mm thick in CM (1:4) on fair faces of of brick masonry /concrete surface on wall with using water proofing compound and finishing the surfaces even and fair without using extra cement complete all as specified and directed Note :- WPC shall be measured and paid for separately as supply only under respectiveitem of sch 'A'.
Supply only integral water proofing compound ISI Marked complete all as specified and directed.
M & L for reinforced precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs ( for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary form work, set in cement mortar 1:4 complete all as specified and directed. (Reinforcement shall be measured and paid for separately under respective item of schedule 'A').
M & L for mild steel TMT bars 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
Demolition and breaking up drain pipes (SGSW, AC or reinforced concrete) 150 mm bore set in cement mortar complete all as specified and directed.
M & L for concrete bed, PCC 1:4:8 type D-2 ( using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed.
S & F 150 mm internal dia of pipe salt glazed stoneware drain pipes, grade 'A' laid in trenches and jointed in cement & sand mortar 1:1,and testing complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
Returning filling in, including spreading ,levelling,watering and well ramming in layers not exc 25 mm th all as specified and as directed
Removing excavated materials nexc 50 m and depositing where directed at a level nexc 1.5 m above the starting point all as specified and as directedturning filling in ,including spreading ,levelling,watering and well ramming in layers not exc 25 mm th all as specified and as directed
Note :-(i) The entire work will run for 11 months as indicated in the tender documents. Completion before time shall not be entertained by the accepting officer. Site for the entire work shall be given to the Contractor in piecemeal manner and as per user requirement. The Contractor or his rep will report to the Engineer-in –Charge/JE Concerned on day to day basis to received the urgent nature of works and execute the same day to day basis. Non attending/reporting/execution of such nature of works in piecemeal manner a penalty of Rs. 100 per day shall be levied to the contractor. The rates quoted by the Contractor shall be included in the respective item of BOQ. No extra payment shall be admissible to the contractor on this account. (ii) Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract”.
Amit Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .