| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.9 L+₹33,950 (1.58%)Rejected-Finance | L2 | Rejected-Finance HIGHER QUOTED BIDDER | |
| 3 | L3₹22.8 L+₹1.3 L (6.06%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance HIGHER QUOTED BIDDER | |
| 4 | L4₹23.2 L+₹1.7 L (7.88%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L4 | Rejected-Finance HIGHER QUOTED BIDDER |
Tender Value
₹34.7 L
EMD Value
₹69,500
Closing Date
15 Jun 2020, 6:00 pmClosed
CWE (AF) Jaisalmer
HQ CWE (AF) Jaisalmer
Scanned copy of Provident Fund Code Number
2020_MES_345236_1
80099/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Phalodi
class D category b(ii)
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹69,500
Yes
14 Jul 2020
16 May 2020
17 Jun 2020
16 May 2020
15 Jun 2020
30 May 2020
Amount
Excavation in trenches in soft/loose soil, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in for laying of cable complete all as specified and directed.
Excavation in trenches in Hard soil, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in for laying of cable complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed.
Material and labour for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supply and lay un reinforced precast concrete cable covers class HV, type 1, flat of size 300 x 180 x 40 mm. complete all as specified and directed.
Supply, Laying & testing in replacement of U/S XLPE cable insulated screen PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) Earthed with strandard aluminium conductor 11 KV grade of size 3 core 95 sqmm complete all as specified and directed. Make:- Nicco/Havells/Gloster/Finolex
S&F in replcement of drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one complete all as specified and directed. Make:- Jaipuria/MEI/Pactil/Atlas
S&F in replcement of vertical type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 400 Amps current rating complete including dismantling existing onecomplete all as specified and directed. Make :-MEI/Pactil/Atlas
Supply and fixing in replacement of insulator pin type porcelain, vitreous, white, brown or green including one galvanized mild steel spindle two GI washers and one nut of size 150 mm height 150mm dia suitable for 11000 volts HT grade complete incl removing of old unsv items complete all as specified and directed. Make:-Bhel/jayshree/jaipur potteries
Supply and fixing in replacement of Disc type insulator 145 mm height 255 mm dia suitable for 11000 volts HT grade porcelain vitreous white,brown or green including galvanized mild steel sectional straps 38X5mm, insulator bolts dia 20mm, washers and nuts complete all as specified and directed incl removing of old unsv items. Make:-Bhel/jayshree/jaipur brothers/Pactil
S & F in replacement lightning arresters suitable for 11000 Volts,expulsion type complete with all fittings, transmission class, dischange capacity 65 KA complete all as specified and directed. Make :- Bhel/Areva/Oblum
supply and stringing ACSR conductor in replacement of (Weasel/ Ferret) on four ploe structure for bus bar line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size complete all as specified and directed. Make:-Bharat conductor/ICC/Alind (Note :- (a) Rate is inclusive of jumper on cutout point/2 pole structure/4 pole structure shall be provided with PVC insulated sleeve.
M&L in replacement for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Supply and replace Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable . Including cutting and removing existing unserviceable joint, excavation near 2 pole structure / HT Panel board / Transformer and taking out loop cable from trench and refilling the trench with excavated material complete all as specified and directed. Make :- M-Seal/Y-Denson/Raychem RPG
Supply and replace Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable including cutting and removing existing unserviceable joint, excavation near 2/4 pole structure / HT Panel board / Transformer and taking out loop cable from trench and refilling the trench with excavated material complete all as specified and directed. Make :- M-Seal/Y-Denson/Raychem RPG
Supply and replace Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable including cutting and removing existing unserviceable joint, excavation near 2/4 pole structure / HT Panel board / Transformer and taking out loop cable from trench and refilling the trench with excavated material acomplete all as specified and directed. Make :- M-Seal/Y-Denson/Raychem RPG
Supply & lay GI tubing light grade 80 mm dia bore in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc complete all as specified and directed. Make :- Jindal/Tata
Cutting of road / hardstanding upto a size not exceeding 20 cms in width and not exceeding 60 cms in depth for laying of HT UG cable protection piep line making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type C1 complete all as specified and directed.
Disconnecting the electric supply from the existing RMU/VCB/Transformer/HT poles and meggering the HT under ground cable for its IR value and ensuring the servicebility by HT megger,locating the faults by HT fault finder instrument for any distance and reconnect the HT cable complete all as specified and directed. NOTE:- Joint kit and HT UG Cable shall be measured and paid separetly.
Supply and laying/spreading 40 mm graded stone aggregate 80 mm thick of any description and in any position at electrical 2/4 pole structure complete all as specified and directed.
M&L in replacement for Earthing complete with galvanised steel earth plate electrode 60 X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 32x6 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 3 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, and cover 6 mm thick in cement concrete (1:2:4) type B1, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and directed with earth resistance not more than 1.0 OHMS. Note:- (i) In case earth resistance valve is more than 5.0 ohms while initial testing, the contractor wiil re-execute the earthing at no extra cost. (ii) The earthig lead i.e 32x6 mm GI strip from electrode onwords shall be suitably protected by 40 mm GI pipe light grade of 7 meter length and suitable GI testing clamp of size 32x6 mm in to be fixed on wall for regular testing of earthing valve.
M&L in replacement for Earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or burried in ground or drawn in conduit/pipes or fixed to poles or any other indicated situation for loop earthing etc as required 32X6mm galvanised iron strip all as specified.
Carrying out calibration of HT VCB panel including VCB 800/630/400 Amps, Make:ABB, after taking proper shut down and disconnecting the cables from panel and VCB Breakers, calibration of over fault relay, earth fault relay, checking of alignment of VCB isolating contacts, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section including incoming/outgoing cable and necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of burnt out/defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc., under the supervision of M/s ABB or authorised dealer/ representative, and refixing the panel in its original position and testing entire satisfaction of Engineer -in- Charge . Note for Item No.23 : (i) The quoted Rate shall be deemed to include all minor spares etc. (ii) If any burnt out/defective items like moving/fixed contacts, tripping coils,earth fault relay etc. will be measured and paid separately under respective items. (iii) Spare parts required other than mentioned here-in-after shall be deemed to be included in the quoted rate.
Supply and fix the following spares for VCB 800/630/400 Amps capacity, Make:ABB, L&T, SIEMENS, CROMPTON GREAVES, BHEL, SCHNEIDER Note: The spares shall be measured and paid only requirement at site during servecing of VCB's. Supply and fix master trip relay ABB mechanical 4NO + 4NC , 110 V for VCB
Supply and fix spring drum Cat part No: V4205, IVYN300950-020 .
Supply and fix spring Cat part No: V4206,GCE9478006P0102.
Supply and fix charging Motor 230V DC/AC Cat part No V6037, IVYN300951-002.
Supply and fix tripping/closing coil-110Volt DC Cat part No: V6084, IN54450007-AB.
Supply and fix emergency trip assembly Cat part No: V6107, VYN400901-AF.
Supply and fix vacuum intrupter Cat part No: IVYN300950-020-01 of VD4 type for VCB.
Supply fix lever Cat part No: IVYNG00950-114 of VB4 type VCB.
Supply and fix roller Cat part No: V6030 of VB4 type VCB .
Supply and fix latest generation SLR140C,Dual rated CT, 3 Phase Over current relay and earth fault relay Auxiliary supply 18 -135 Volt AC/DC +/- 15% operated for VCB all as specified and as directed. Make:- L&T/ABB/Avana/Stelmec
Carrying out calibration of ACB panel including ACB 630 Amps, Make :ABB, after taking proper shut down and disconnecting the cables from panel and ACB Breakers, calibration of over fault relay, earth fault relay, checking of alignment of ACB isolating contacts, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section including incoming/outgoing cable and necessary LT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with LT taps wherever necessary, with and including replacement of burnt out/defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc., under the supervision of M/s ABB or authorised dealer/ representative, and refixing the panel in its original position and testing entire satisfaction of Engineer -in- Charge .
M&L for repairing/ servicing calibrating / testing /setting of fault tripping and recommissioning complete as mentioned in maintance and operation manual of 11 KV HT RMU SF6 (MCR)breaker all as per OEM instructions.(Make:- CG /ABB) (Note : SF6 Gas charging will be measured and paid seperately (i) Repairing / servicing shall be carried out through O.E.M of manufactures engineering / technician only. (ii) Cost of small spares like gasket, battery,O ring nuts, bolts and lubricants / cleaning required for servicing of RMU is deemed to be included in the coated rate. However cost of the major spare parts will be measured and paid separatly under revelant items of Sch'A'.
M&L for gas charging breaker by using SF 6 gas all as specified and directed.
M&L for saver mechanism ON/OFF operating complete with main spring,fire stick,triping coil system etc.for RMU (MCR)
M&L for actuator motor for operating mechanism charging motor ON/OFF for (RMU) MCR .
M&L for self powered relay CGI14S suitable for RMU (MCR).
M&L for lemun type live indicator complete with electrical circuit suitable for RMU (MCR).
M&L for power card (SMPS card) complete with all electrical circuit suitable for RMU (MCR).
M&L for right angle boot for RMU (MCR)
star electricals
Hariom Construction Company
Anil Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .