Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Negotiated amount | |
| 2 | L2₹21.5 L+₹4.4 L (25.3%)Rejected-AOC | L2 | Rejected-AOC ok |
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
17 Feb 2021, 5:00 pmClosed
Executive engineer
Executive engineer Kerala state Housing Board ,Kasaragod
Retender Electrical work of Vellarikkundu Mini Civil station
2021_KSHB_413497_1
EE/28/KSHB/KSGD/2020-21
Open Tender
Civil Works - Buildings
Item Rate
10 days
Vellarikundu
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹43,000
8 Jul 2021
9 Feb 2021
20 Feb 2021
9 Feb 2021
17 Feb 2021
9 Feb 2021
Amount
PANEL BOARD COMMON ACCESSORIES
90.6.5.19 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
90.6.5.20 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 4.00 sq mm
90.14.1.1 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.2.2 : Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.2.3 : Supply and providing 4mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.2 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.3 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
90.14.3.4 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 40 x 3mm heavy duty flat neoprene gasket in the panel board
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7 : Supply and providing copper earth bus in the panel board
od290143/2020_2021 : Supplying and fixing Multi function meter to read:V, A, F , 3 phase accuracy class 0.5 complete with connections, testing and commissioning etc. as required
od290144/2020_2021 : LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour(2012 kpwd approved rate)
od290145/2020_2021 : Supplying and fixing 0.5 amps to 2amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing Panel board, complete with connections, testing and commissioning etc. as required.<br>Single pole
od290146/2020_2021 : Supply and providing Rotary handle upto 250A( Direct type)
od290147/2020_2021 : Supply and providing Spreader/Terminal adapter Kit Extended terminal for 3/4 pole MCCB of rating upto 160 A
od290148/2020_2021 : Providing Screw knob with PVC Grip for using Cubical panel compartment door installation
od290149/2020_2021 : Providing bolts and nuts for various sizes including plate washer for using Cubical panel accessories installation
od290150/2020_2021 : Labour charge for Loading and unloading charges for Electrical Panel boards
od290151/2020_2021 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 2.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment's including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. <br>
od290152/2020_2021 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 1.50 sq mm single run with required sockets.conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. <br>
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
MAIN SWITCH BOARD (MSB)
2.2.9 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.400 Amp, 35 KA,TPMCCB
od290117/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 400/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
90.14.11.3 : MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT.
od290127/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.3 Phase, 4 wire, 110 V (L-L), -/1 A CT or -/5A CT, accuracy class 0.2, TOD meter<br>
od290131/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Smart demand controller without port accuracy class 0.5<br>
2.2.8 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.315 Amp., 35 KA,TPMCCB
2.2.13 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 30 KA 4 Pole
2.2.15 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 Amp, 36 KA
2.2.16 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 Amp, 36 KA
COMMON PANEL(AMF)
2.2.15 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 Amp, 36 KA
od290118/2020_2021 : Supply and providing 200 amp 4P contactor for AMF operation of common panel
od290121/2020_2021 : Providing, fixing. Testing and commissioning of following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required AMF (Auto main failure ) Relay for automatic operation (Approved make and model)
90.14.11.17 : MCCB AccessoriesSupply and fixing kastel interlock kit up to 250A.
od290132/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 200/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
90.14.11.5 : MCCB AccessoriesSupply and fixing 100 - 200A earth fault module of MCCB with builtin CBCT.
od290127/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.3 Phase, 4 wire, 110 V (L-L), -/1 A CT or -/5A CT, accuracy class 0.2, TOD meter<br>
2.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
APFC PANEL
od290114/2020_2021 : Supply and Providing 3 Pole Capacitor duty contactors for switching capacitor banks 33 to 40 kVAR with AC Coil,
od290119/2020_2021 : Supply and Providing 3 Pole capacitor duty contactor for switching capacitor bank 25 kvar with ac coil
od290122/2020_2021 : Supply and providing 3 Pole Capacitor duty contactors for switching capacitor banks 11 - 15 kVAR with AC Coil,
od290128/2020_2021 : Supply and providing 3 Pole Capacitor duty contactors for switching capacitor banks 7.5 - 10 kVAR with AC Coil
od290133/2020_2021 : Supply and providing 3 Pole Capacitor duty contactors for switching capacitor banks 4 - 7 kVAR with AC Coil,
od290136/2020_2021 : Supply and installation of Emergency Push Button
od290138/2020_2021 : Supply and providing 14 stage 440/110 V 5A/1A, Intelligent Power Factor Controllers (IPFC) in the existing APFC cubical panel
od290111/2020_2021 : Supply and Providing Push Button Green with legend 'start', (Contact - 1 NO)
od290115/2020_2021 : Supply and Providing Push Button - Red with legend 'stop', (Contact - 1 NC)
od290139/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 250/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
od290140/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Single Phase Ammeter accuracy class 1 <br>
od290142/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Three phase Voltmeter accuracy class 0.5<br>
od290116/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
2.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
2.2.16 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 Amp, 36 KA
90.14.24.68 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.71 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.73 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.75 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.25 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.77 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.40 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
METERING PANEL I
2.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA
od290120/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existingcubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 120/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
od290123/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existingcubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Single phase KWh meter, 240 V, 10 ? 40 A ,electronic type energy meter ? accuracy class 1
od290129/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>63 Amp, 10 KA, DPMCCB
od290135/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.3 Phase, 4 wire, CT operated, 240 V, 5-10 A , electronic type energy meter ? accuracy class 1<br>
2.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
od290124/2020_2021 : Supply and installation of suitable meter viewing glass in the existing metering panel
od290130/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 32 A, 2 Way neutral links mounted on DMC/SMC base
od290134/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 32, HRC Fuse Base with HRC Fuse link
METERING PANEL II
od290120/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existingcubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 120/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
od290123/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existingcubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Single phase KWh meter, 240 V, 10 ? 40 A ,electronic type energy meter ? accuracy class 1
od290129/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>63 Amp, 10 KA, DPMCCB
2.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA
od290135/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.3 Phase, 4 wire, CT operated, 240 V, 5-10 A , electronic type energy meter ? accuracy class 1<br>
2.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
od290124/2020_2021 : Supply and installation of suitable meter viewing glass in the existing metering panel
od290130/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 32 A, 2 Way neutral links mounted on DMC/SMC base
od290134/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 32, HRC Fuse Base with HRC Fuse link
METERING PANEL III
2.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA
od290120/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existingcubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 120/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
od290124/2020_2021 : Supply and installation of suitable meter viewing glass in the existing metering panel
od290130/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 32 A, 2 Way neutral links mounted on DMC/SMC base
od290134/2020_2021 : Providing and fixing following rating in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 32, HRC Fuse Base with HRC Fuse link
od290135/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.3 Phase, 4 wire, CT operated, 240 V, 5-10 A , electronic type energy meter ? accuracy class 1<br>
2.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
WATER PUMP PANEL
od290116/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
od290111/2020_2021 : Supply and Providing Push Button Green with legend 'start', (Contact - 1 NO)
od290115/2020_2021 : Supply and Providing Push Button - Red with legend 'stop', (Contact - 1 NC)
od290125/2020_2021 : Supply and providing 9 A, 3 pole power Contactors (For 5.5 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
90.14.28.13 : S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 2 HP submersible motor pumps (DOL)
90.14.28.14 : S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL)
od290126/2020_2021 : Providing and fixing 50/5 to 75/5 A, 5 VA, accuracy class 3, Resin Cast Metering CT
od290135/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.3 Phase, 4 wire, CT operated, 240 V, 5-10 A , electronic type energy meter ? accuracy class 1<br>
od290111/2020_2021 : Supply and Providing Push Button Green with legend 'start', (Contact - 1 NO)
od290115/2020_2021 : Supply and Providing Push Button - Red with legend 'stop', (Contact - 1 NC)
od290125/2020_2021 : Supply and providing 9 A, 3 pole power Contactors (For 5.5 HP motor), AC 3 rating at 415 V, with AC Coil, Auxiliary contacts, 1 NO/INC
od290126/2020_2021 : Providing and fixing 50/5 to 75/5 A, 5 VA, accuracy class 3, Resin Cast Metering CT
od290116/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
od290135/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing<br>cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.3 Phase, 4 wire, CT operated, 240 V, 5-10 A , electronic type energy meter ? accuracy class 1<br>
90.14.28.1 : S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor
90.14.28.14 : S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL)
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2P CHANGE OVER SWITCH
od290112/2020_2021 : Supply, installation, Testing and commissioning of manual type operated type 2 pole mcb type change over including metal Enclosure
HT PANEL
od290113/2020_2021 : Supply and installation testing commissioning of 630A Factory made HT Panel Set having one Incomer and One outgoing, Indoor Type, Metal Clad Floor Mounted of 11 KV, incorporating Load Break Switch , Panels equipped with all specified accessories i.e. CTs, PTs (Indoor Type), metering and protection system including termination etc.The panel should be Internal Arc fault withstand capacity: Panel enclosure shall be self-supporting floor mounted, indoor, dust and vermin proof, totally enclosed as per IEC 62271- 200. Special attention must be given so that all the apparatus shall be designed to obviate the risk of accidental short circuit due to insects, mites, rodents or microorganisms. The inspection window on the LBS door shall be made of toughened glass. As per IEC 62271-200, it should bear the same mechanical strength as that of the enclosure. Circuit breaker shall be mounted on a withdrawable truck which shall be horizontally draw out from service position to isolated position i.e. “Complete Roll on floor type of design”. Switchgear shall be fully type tested for extended Switchgear shall be E2 and C2 electrical parameter compliance.11KV Indoor Load Break Switch Panel Panel consists of :-1. 11KV 630A 26.3KA Load Break Switch2. HT HRC 15A Fuse, Seal off Bushing , 3. Al bus Bar, Support Insulators, wiring , earthing etc (INDOOR TYPE)as per the direction of Engineer in charge
AMS Electro Consultants and Contractors Private limited
Bidder Name
Peter Electricals Pvt. Ltd
AMS Electro Consultants and Contractors Private limited
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_587465.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .