Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | ₹12.9 L | L1 | Accepted-AOC DUE TO L1 |
| 2 | L2₹13.9 L+₹99,990 (7.75%)Rejected-AOC | ₹13.9 L+₹99,990 (7.75%) | L2 | Rejected-AOC DUE TO L2 |
| 3 | L3₹15.2 L+₹2.3 L (17.5%)Rejected-AOC | ₹15.2 L+₹2.3 L (17.5%) | L3 | Rejected-AOC DUE TO L3 |
| 4 | L4₹17.6 L+₹4.8 L (36.8%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | ₹17.6 L+₹4.8 L (36.8%) | L4 | Rejected-AOC DUE TO L4 |
| 5 | L5₹18.2 L+₹5.3 L (40.9%)Rejected-AOC PLOT NO 2 INDUSTRY AREA NEAR LAL WARE HOUSE OPP OLD HOUSING BOARD COLONY SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | ₹18.2 L+₹5.3 L (40.9%) | L5 | Rejected-AOC DUE TO L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
28 Oct 2020, 6:00 pmClosed
CWE YOL CANTT
HQ CWE YOL CANTT
REPAIR AND MAINTENANCE OF HT PANEL LT PANEL LT UG CABLE HT UG CABLE AND MISC WORKS UNDER GE KH YOL CANTT
2020_MES_360895_1
CWE/Y-75/2020-21
Open Tender
Civil Works
Works
180 days
YOL Cantt
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (KH) Yol
₹40,000
22 Dec 2020
1 Oct 2020
29 Oct 2020
1 Oct 2020
28 Oct 2020
14 Oct 2020
Amount
Excavation in trenches for pipes and manholes in any type of soil n.exc 1.5 metres wide and not exc 1.5 metres deep and getting out complete all as specified and directed.
Excavation in trenches for pipes and manholes in any type of soil n.exc 1.5 metres wide and exc 1.50 metres but not exc 3.00 metres in depth and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n. exc 50 metres and depositing where directed at a level n.exc 1.5metres above the starting point complete all as specified and directed.
Plain cement concrete M-7.5 nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc. and as in mass concrete, complete all as specified.
Plain cement concrete M-15, nominal mix, B-0 using 12.5mm graded mechanically crushed stone aggregate as, in lintels upto 1.5 metre clear span, steps, seismic and other similar bends, coping, bands plates for serving hold fasts, filling in mild steel frames etc. and the like including weathering slighting rounded or chamfered angles and throating complete all as specified. Note:- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed.
Taking up or down steel tubing 50/ 80mm dia as in cable protection as in road crossing, along poles, walls, floors, drains complete all as specified and directed.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors drain of 50mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed. Make of GI tubing:- Makes as mentioned in Appendix 'C'.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors drain of 80mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed. Make of GI tubing:- Makes as mentioned in Appendix 'C'. Note for Serial Item No 09 to 11:- Excavation and earth work shall be measured and paid under respective Items of BOQ.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 2 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trenches passing through pipe/ ducts/ surface of wall/ ceiling using necessary clamps, screws and saddles etc including testing and taking out old unservicable cablecable covers complete all as specified. Note for Serial Item No 12 to 21:- Excavation & Earth work, cable cover, GI pipe and sand cushioning shall be measured and paid separetly under respective Items of BOQ.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 16 sqmm including taking down old unservicable cable, complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm including taking down old unservicable cable, complete all as specified.
Renewal of sub main wiring with two single core, FRLS, PVC insulated cable 1100 volts grade with copper stranded FRLS conductor of size 2.50 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 1.50 Sqmm and drawn into and including PVC rigid conduit fixed to wall/ ceiling/ pole with all fittings/ accessories/ clamps, junction boxes 1 to 4 way 20mm dia, connecting with MCB's or bus bars with suitable size of copper lugs and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm with suitable clamps made out of flat iron 50X6mm including nuts, bolts and washers, complete all as specified.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm with suitable clamps made out of flat iron 50X6mm including nuts, bolts and washers, complete all as specified.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm with suitable clamps made out of flat iron 50X6mm including nuts, bolts and washers, complete all as specified.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm with suitable clamps made out of flat iron 50X6mm including nuts, bolts and washers, complete all as specified.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 mm to 95 sqmm, complete all as specified.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 mm to 185 sqmm, complete all as specified.
Renewal of PVC cable end terminal box, outdoor type, 217 mm X 253 mm X 115 mm with opaque lid, provision for cable incoming and outgoing from bottom, DIN rails comprising of one MCB SP 6-32 Amps, cable glands suitable and one porcelein connector four way complete fixed on wall/ pole with necessary clamps, screws etc all as specified and directed including taking out old unservicable terminal box, complete all as specified and directed.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (09 metres long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
Renewal of pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade grade includng taking down existing insulators and removing from site, complete all as specified.
Shackle type insulator porcelain vitreous white, brown or green 75mm high and 90mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31x3mm size, 12mm dia insulator bolts, washers and nuts, complete all as specified including taking down old insulators of any type, shape and size, all as specified and directed.
Renewal of lightning arresters (Set of three) expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 volts including taking out old unservicable arrester and removing from site complete all as specified and directed.
Renewal of aluminium strip 25 mm X 3.15 mm with saddles and fixing screws as in roof conductor and down conductor all as specified and directed.
Renewal of MCCB any size/ capacity with MCCB 3 pole 160 Amps having rupturing capacity 16KA with fixed thermal and fixed magnetic release including suitable thimbles/ extended terminal with nuts, bolts and washers etc including minor works required additional/ alternation for fixing and connecting up of MCCB all as specified and directed. Make : IndoAsian Cat Part No "830090" or equivalent in Makes mentioned in Appendix "C".
Renewal of MCCB any size/ capacity with MCCB 3 pole 160 Amps having rupturing capacity 36KA with adjustable thermal and fixed magnetic release including suitable thimbles/ extended terminal with nuts, bolts and washers etc including minor works required additional/ alternation for fixing and connecting up of MCCB all as specified and directed. Make : IndoAsian Cat Part No "830112" or equivalent in Makes mentioned in Appendix "C".
Renewal of MCCB any size/ capacity with MCCB 4 pole 400 Amps having rupturing capacity 36KA with adjustable thermal and adjustable magnetic release including suitable thimbles/ extended terminal with nuts, bolts and washers etc including minor works required additional/ alternation for fixing and connecting up of MCCB all as specified and directed. Make : IndoAsian Cat Part No "830176" or equivalent in Makes mentioned in Appendix "C".
Renewal of MCCB any size/ capacity with MCCB 4 pole 500 Amps having rupturing capacity 50KA with adjustable thermal and adjustable magnetic release including suitable thimbles/ extended terminal with nuts, bolts and washers etc including minor works required additional/ alternation for fixing and connecting up of MCCB all as specified and directed. Make : IndoAsian Cat Part No "830177" or equivalent in Makes mentioned in Appendix "C".
Cable route indicator made out of 2 mm thick mild steel sheet of size 20 cms X 15 cms duly coated with two coats of black paint over a coat of red oxide primer duly written the size of LT/ HT cable in white paint and welded to equal angle of size 30X30X3mm, 45 cms long and errected in ground in such a way that it is 15 cms above ground level and 30 cms below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-I, using 20 mm graded crushed stone aggregate of size 15 cms X 20 cms X 45 cms all as specified & directed. Note:- Cost of PCC and earth work & excavation shall be deemed to be included in unit rate quoted by contractor.
Pole mounting bracket made out of galvanised iron pipe 50mm dia, medium grade of length 1.50 metres with two clamps made out of mild steel flat 25x4 mm with nuts, bolts and washers complete accesseries including two coats of aluminium paint after preparation of surfaces and taking down existing unservicable brackets all as specified and directed.
PVC seperator suitable for four ACSR conductor feeder, complete all as specified & directed.
Painting to existing steel tubular LT poles, 9 metres long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers/ letters of height exceeding 5 cms but not exceeding 10 cms with black paint after painting, complete all as specified & directed.
Painting to existing concrete LT poles, 8.50 metres long with two coats of cement base paint and painting cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers/ letters of height exceeding 5 cms but not exceeding 10 cms with black paint after painting, complete all as specified & directed.
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 65x90mm, clearance of hole 16 mm, complete all as specified and directed.
Supply, installation, testing and commissioning gang operated air break off load connecting switch HT, 11KV, tripple pole, each plate consisting galvanised steel base, verticle type mounted on 15 No's post insulators and steel frame, non ferrous knife and spring loaded contacts, arcing horns complete with dropout fuse element assembly, operating rod of GI pipe, medium grade, 20 mm dia (without joint) of suitable size and locking arrangement, connections, mild steel frame with PG clamps and sleeves etc required for current rating 400 amps capacity including taking down unservicable GOD of any type, shape & size with steel frame and removing from site all as specified and directed.
Cutting/ trimming of trees branches from LT/ HT lines upto 2 metres horizontal & 2 metres vertical distance from both sides of electric line including shifting of cut trees branches away from site complete all as directed. Note:- Distance between two adjacent poles irrespective of distance shall be considered as one span.
Earthing complete with galvanised steel earth plate electrode 60 cms x 60 cms x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0 mm dia (as earth lead wire) by means of bolt, nuts, check nuts and washers of galvanised steel and earth wire protected by provision of galvanised iron pipe, light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-15, type B-1, using 20mm graded crushed stone aggregates with 40 mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25mm x 25 mm x 3 mm with lugs 2 No's with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom, 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32 X 6 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. Note for Serial Item No 50 & 51:- Item of earthing includes the cost of 7.50 metres long galvanised iron 32mm X 6mm strip/ 4mm GI wire along with GI protection pipe.
Supply, installation, commissioning and testing LT bus bar chamber, outdoor, cubical type, pedestal type factory made, CPRI approved of size 0.45 metres X 0.75 metres X 0.40 metres, fabricated out of 3.15 mm thick mild steel sheet mounted on frame of mild steel angle iron 50 mm X 50 mm X 5 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm X 50 mm X 5 mm thick fixed on plain cement concrete foundation (As per manufacturer's instructions) having height 60 cms from ground level & 30 cms below ground level, built in plain cement concrete M-15, type B-0, using 12.5 mm graded crushed stone aggregate. Bus bar box shall be totally enclosed weather proof and vermin proof, self ventilated with front and rear opening (double door with neosprene gasket and locking arrangement) with IP-54 protection as per IS-8623 duly powder coated internally and externally with provision of two No's earth terminals on sides for 433 volts, 3 phase, 4 wire having TPN aluminium bus bars of 200 Amps rating, full for phase and half for neutral, duly drilled holes for connections mounted on epoxy/ porcelain insulators in totally enclosed chamber with three phase and neutral 415 volts, AC, RYB insulated with different color code and sleeved insulators complete prewired with PVC insulated, unsheathed, 1100 volt grade multistrand copper conductor cable upto bus bars, meters, MCCB's etc including all incoming and outgoing cable connection with suitable size of copper lugs/ gland including providing aprons at the bottom to avoid entry of vermins, reptiles and taking down/ dismantling old unservicable LT bus bar box complete all as specified and directed and also comprissing of following:-
INCOMING:- MCCB 100 Amps, 3 pole, 25KA breaking capacity, 415 volts with adjustable thermal and fixed magnetic release as incoming - 01 No (CAT Part No IHCASTO100 of "Havell's" or equivalent in makes mentioned in Appendix 'C').
jatindera enterprises
M/S VIG AND COMPANY
R K BUILDERS
M/S ASHWANI KUMAR AND COMPANY
M/S HIM BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .