Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹16.2 L+₹2.2 L (15.5%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹17.1 L+₹3.0 L (21.3%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹17.9 L+₹3.9 L (27.6%)Rejected-Finance 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹21.5 L+₹7.4 L (52.8%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
11 Jul 2020, 6:00 pmClosed
GE Chandigarh
GE Chandigarh
REPAIR/REPLACEMENT OF UNSV E/M FITTINGS AND FIXTURES, REPAIR TO GEYSERS AND REPLACEMENT OF EXISTING UNSV CFL/TUBE LIGHT FITTINGS WITH LED FITTINGS IN CERTAIN BUILDINGS AT N AREA AND HALLOMAJRA UNDER GE CHANDIGARH.
2020_MES_353184_1
GE/CHD-21/2020-21
Open Tender
Civil Works
Item Rate
210 days
Chandigarh
Class D Cat b i
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹60,000
Yes
26 Aug 2020
16 Jun 2020
13 Jul 2020
16 Jun 2020
11 Jul 2020
29 Jun 2020
16 Jun 2020 - 22 Jun 2020
Amount
Taking out old unsv meter and DB box wooden/steel any size any description, carefully after disconnecting incoming and outgoing supply from energy meters, taking out energy meters very carefully after taking reading of energy meter, marking the house no on the meter and indetifing the outgoing circuit in presence of user and MES rep. and making good the disturbed surface using brick work, cement work, plaster and colour wash to match the adjoining area of wall. Note : Cost of makig good disturbed surface in all respect is deemed to be included in the quoted rates.
M&L for fabrication and fixing of energy meter box havng IP -42 protection as per IS spections,fabicated out of CRCA sheet 1.6 mm thick ,not less than 14 gauge sheet of size 100x 60 x 30 cm having total 06 compartment ,i.e 04 for fixing of single phase energy meter with one No MCB SPN on DIN rail , 01 for fixing of 4 pole MCCB 63/100 amps as incomer and one for three phase TPN bus bar. Each compartment shall be provided with 3 mm thick hylem sheet for making meter box shock prof. Incomer compartment of meter box shall be provided with MS gland for cable entry of size 4 core 25 sqmm, each copmpartment should have independent non breakable glass cover in upper half portion for taking the reading with locking arrangement . Meter box shall have following: (a) TPN copper bus bar (Tin plated) of capacity 100 Amps mounted on epoxy insulators insulated with heat shrink colour coded sleeves. (b) MCCB 63 Amps 4 pole, 16KA with adjustable thermal magnetic protection 0.7 to 1.0 times of current rating- 01 No (c) MCB SPN 32 Amps -4 Nos (To be fixed alogwith meter on DIN rail), (d) Internal wiring with 6 Sqmm copper cable sigle core multistranded from busbar to meter and meter to MCB SPN. Meter box shall be semi glossy finish with powder coated sprayed paint and baked at high temprature. Meter box shall be fixed (partially embedded) on wall including making nitch in walls and making good the surface complete all as specified and as directed.
All as per item No 2.00 above but meter box of size 180x60x30 cm having 10 compartments ie 08 for fixing of single phase energy meter with 01 No. MCB SPN mounted on din rail, 01 No for fixing of 04 pole MCCB 63/100 Amps as incomer and 01 TPN bus bar and meter box with the follwing items:- (a) TPN copper bus bar (Tin plated) of capacity 200 Amps mounted on epoxy insulators insulated with heat shrink colour coded sleeves. (b) MCCB 100 Amps 4 pole, 25 KA with adjustable thermal magnetic protection 0.7 to 1.0 times of current rating- 01 No (c) MCB SPN 32 Amps -8 Nos (To be fixed alogwith meter on Din rail), (d) Internal wiring with 6 Sqmm copper cable sigle core multistranded from busbar to meter and meter to MCB SPN. Meter box shall be semi glossy finish with powder coated sprayed paint and baked at high temprature. Meter box shall be fixed (partially embedded) on wall including making nitch in walls and making good the surface complete all as specified and as directed. Notes for Srl item No 2 & 3 above:i) Drawing of meter box shall be got approved from Engineer-in-Charge/GE before fabrication. ii) Energy meter removed vide Srl item No 01 above shall be refixed and connected correctly as the detail noted down while removing of the meters in presence of MES rep and user.Cost of fixing of energy meters is deemed to be included in the quoted rates.iii) cost of MCBs SPN 32 Amps B curve 10 KA ,MCCB 4 pole and TPN bus bar is deemed to be included in the quoted rates. iv) Meter box shall be fabricated by CPRI certificate holder firm only and certificate to this effect shall be sumitted to the deparment before payment of RAR.
Taking out old unsv Minitature Circuit Breaker DB/Bus bar chamber/mainswitch of any description and deposited in MES store yard for reuse or issue under sch of credit.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for Minitature Circuit Breaker DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 12 way SPN suitable for Minitature Circuit Breaker DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way TPN suitable for Minitature Circuit Breaker DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete as in repair all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way VTPN (IP43) suitable for and incl MCCB TPN 100 mps 16 KA, DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 6 way VTPN (IP43) suitable for and incl MCCB TPN 100 mps 16 KA, DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed. Make Legrand/ABB/C&S/Havells. Note for item 4 to 9 : Serviceable Minitature Circuit Breakers SP/SPN/TPN as reterived while dismantling of Minitature Circuit Breaker DB shall be refixed in new DBs and cost of the same is deemed to be included in the quoted rates.
M&L bus bar chamber size 40 cmx25cmx20cm with tin plated copper plated bus strip 4 nos provision of MS gland for cable entry with locking arrangement of cap 200 amps 415 volts 50 hz partly flushed to wall and including making good to disurbed potion and colour wash to match the existing surface . Make Legrand/ABB/Indoasian/Siemens/C&S/Havells Note : 1. All connection of incoming/outgoing cable shall be made with providing copper thimble for copper cable and aluminium thimble for aluminium cable
Supply and fix in repair moulded case circuit breaker 4 pole 63 Amps 16 KA electromagneic thermal release for overload and short circuit protection adjustable type in suitable sheet metal enclosure with and incl 02 Nos MS gland for incoming and outgoing cable of size 4 C 16/4C 25 sqmm complete all as specified and as directed . Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
Supply and fix in repair moulded case circuit breaker 4 pole 100 Amps 16 KA electromagneic thermal release for overload and short circuit protection adjustable type in suitable sheet metal enclosure with and incl 02 Nos MS gland for incoming and outgoing cable of size 4 C 25/3.5 C 50 sqmm sqmm complete all as specified and as directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F Miniature Circuit Breaker single pole ISI marked ISI Marked `B' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 6-32 Amp breaking capacity 10 KA as in repair etc all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F Minitature Circuit Breaker single pole ISI marked ISI Marked `B' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 40 Amp breaking capacity 10 KA as in repair etc all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F Minitature Circuit Breaker single pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40 Amps 10 KA breaking capacityas in repair etc all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F Minitature Circuit Breaker single pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 63 Amps 10 KA breaking capacityas in repair etc all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F Minitature Circuit Breaker triple pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 63 Amps 10 KA breaking capacity as in repair etc all as specified and directed.Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F Minitature Circuit Breaker triple pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 100 Amps 10 KA breaking capacity as in repair etc all as specified and directed.Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
Supply and fix RCCB (Residual current circuit breaker) AC type double pole protection sensitivity against leakage current 30mA of rating 40 Amps conforming to IS speification -IS-12640-1 and IEC-61008-1 Make Legrand/Havells/Hager/Siemens.
S&F of sub main wiring with two single core 4 sqmm and one single core 4 sqmm as earth continuity cable PVC insulated multi-straned copper conductor drawn through in and including PVC rigid no-metallic surface/concealed conduit of 20mm dia and connection at both ends with copper legs, colour code for phase Red /Yellow/Blue for neutral Black and for earth green, complete complete incl cutting and chasing and making good the disturbed surface all as specified
All as per item No 20 above but wiring with two single core 6 sqmm
All as per item No 20 above but wiring with two single core 10 sqmm
Material and labour for submain wiring with four single core PVC insulated flexible copper conductor cable of size 4x 10 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2x 10 sqmm as earth lead in & including surface/ concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engineer - in - Charge.
Material and labour for submain wiring with four single core PVC insulated flexible copper conductor cable of size 4x16 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2x 16 sqmm as earth lead in & including surface/concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engineer - in - Charge.
Supply and fix in repairs Rigid non metallic PVC conduit of size 25 mm ext dia exclusive of boxes (junction/terminals) but inclusive of all tees bends elbow reducer, bell mouth tube end and fixing accessories such as coupler lock , nuts saddles pipes hook etc.
Supply and fix in repairs Rigid non metallic PVC conduit of size 32 mm ext dia exclusive of boxes (junction/terminals) but inclusive of all tees bends elbow reducer, bell mouth tube end and fixing accessories such as coupler lock , nuts saddles pipes hook etc.
M&L for in repair earthing in repair complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 4.0 metre deep below ground level) vertically, with top edge of the plate not less than 3.25 mtr below normal ground level, connected to galvanized iron wire 4mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 15 mm dia GI light grade earth lead protection pipe, complete all as specified and directed.
Taking down carefully copper /aluminum point wiring (light,fan,socket or power ) complete, including fixture and fitting such as switches,ceiling rose ,holders regulators,sockets any type light fitting etc for taking credit,removing from site of work and making good to the disturbed surfaces of walls/floors etc complete all as specified and as directed by Engineer - in -Charge.
M&L Point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable PVC insulated ISI marked unseathed FRLS cable of size 1.5 sq mm copper conductor as earth wire to common earth dolly in concealed/surface conduit including concealed in wall modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switches, sockets, fan regulator etc for One light/fan point controlled by one way one module modular switch 6 amps 240 volts : Note:-1. Colour code of wiring should be (for phase -Red, Neutral-black & earth wire green) 2. Modular switch sockets fan regulators shall be meaured and paid separately uner respective items. 3. Cost of mudular MS box , codular cover plate and frame of any modules as required at site and as directed by Engineer-in-charge is deemed to be included in th quoted rates.
All as per item No 29 above but one 5 pin 6 Amps switch socket out let point on independent board
All as per item No 29 above but one 5 pin 6 Amps switch socket out let point on same board
All as per item No 29 above but one call bell point controlled by one way bell push switch
All as per item No 29 above but one light point controlled by two way switch
All as per Item No 29 but wiring with 2.5 Sqmm nominal area cable for 15 Amp socket outlet three pin Independent point with2.5 Sqmm copper conductor for earthing (green colour).
All as per Item No 29 but wiring with 4.00 Sqmm nominal area cable for 20 Amp socket outlet three pin Independent point with 4.00 Sqmm copper conductor for earthing (green colour).
Point wiring for one light point/fan point controlled by one switch with 1.5 Sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 Sqmm PVC insulated unsheathed copper conductor single core cable (green colour as earth lead in and including concealed non metallic rigid PVC conduit medium grade with all fittings (ISI marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, iuncluding cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per item No 36 above but one 3 pin 6 Amps switch socket out let point on independent board
All as per item No 36 above but one 3 pin 6 Amps switch socket out let point on same board
All as per item No 36 above but one call bell point controlled by one way bell push switch
All as per Item No 36 but wiring with 2.5 Sqmm nominal area cable for 15 Amp socket outlet three pin Independent point with 2.5 Sqmm copper conductor for earthing (green colour).
All as per Item No 36 above but wiring with 4.0 Sqmm nominal area cable for 20 Amp socket outlet three pin Independent point with 4.00 Sqmm copper conductor for earthing (green colour).
S&F ceiling rose surface bakelite 65x50mm three terminals complete all as specified ISI marked,
S&F modular one way switch 6 Amp 240 volts suitable for one model etc complete as specified and directed.
S&F modular socket shutter suitable for 6 Amp 2/3 pin combined 250 volts complete as per specified and directed .
S&F modular switches suitable for 16 Amp 240 volts complete as specified and directed.
S&F modular socket shutter suitable for 16 Amp 2/3 pin combined 250 volts complete as specified and directed.
S&F sheet metal enclosures single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole Minitature Circuit Breaker 240 volts 20 Amps, complete all as specified.
S&F modular step type fan regulator suitable for 120 watt 250 volts complete all as specifed and directed .
S&F modular two way switch 6 Amp 240 volte suitable for one model etc complete as specified and directed.
M&L for call bell ding dong AC 230 Volts single polw etc complete as specified and directed .
S&F modular bell push switch 6 Amp 240 volte suitable for one model etc complete as specified and directed.
Switch piano flush button single pole one way 5 amp 240 Volts
Switch piano flush button single pole one way 15 amp 240 Volts. .
M&L for sockets 5 Amps 5 pin flush type, 230 volts.
Socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts.
S&F switch bell push 6 amps 240 volts
S&F in repair electronic digital wireless bell operated on 240 volts AC with operating range 100 mtrs in open air complete with remote push button with 12 volts 23 A battery.
S&F in repair decorative box type fitting with blue colour end cap for LED tube 20 watt luminaire for 230 volt AC incl LED tube 20 watt with inbuilt surge protection device complete all as specified & approved by EIC.
S&F in repair LED tube light decorative box type fitting TRIMLINE type complete with LED tube 36 watts, 5700K integrated LED batten and inbuilt surge protection device.
S& F recess mounting/ Sleek suspended white powder coated aluminium housing,LED 2x2 feet luminaire36Watt suitable for armstrong POP ceiling with separate electronic driver & high brightness natural white LED. complete, including suspension assembly as complete all as specified and as directed
Supply and fix in repair 36 watts LED flat panel 1x4 feet glare free opal difuser recess /surface mounted complete with 36 watts LED and inbuilt surge protection device all reqd at site complete all as specified and as directed
S& F recess/surface mounting/ LED slim round/square downlighter with glare free opal diffuser 12Watt suitable for armstrong POP ceiling with separate electronic driver & high brightness natural white LED. Complete. including suspension assembly
Supply , fixing and connecting Mirror light LED 8/9/10 watt, 1 ft long. Cat No BCLSB 10 WH of make Bajaj or equivalent as approved by GE.
S&F in repairs energy saving new generation 10 W LED IP 65 bulkhead luminaire with opal diffuser incl 3 core flexible cord from ceiling rose to connector of fitting etc complete as specified and directed
S&F in repairsLED Bollard 10Watt with die cast aluminium housing with polycarbonate housing and cylinder diffuser IP 65 conforming to cat part No HLOB -03-10-CW of Halonix or equivalent in Cromption/Bajaj/C&S complete with 10 watts LED, Driver and surge protector including making new connection with three core PVC copper flexible cable of size 23/.0076
S& F in post top decorative globe type lantern LED 30 Watt (neutral white) with high efficient LED and polycarbonate diffuser, sutable MS/die cast alumn spigot mounting assebly ,glare free conforming to IP 65 ptrotection with and incl necessary fixing arrangement complete all as specified including taking down old unserviceable fittings of any size/ wattage complete and as directed by Engineer -In-Chrge
S&F in repair LED engagement lights box prewired with Red and Green LED bulb 03 Watts each with holders complete all as specified and directed by Engineer -in-charge
S&F in repair lamp holder pvc/polycarbonate type with back plate suitable for batten fitting including LED lamp of 10 watt (Cool Light) etc complete as specified and directed .
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (single door) 2 way SPN suitable for Minitature Circuit Breaker DB's 240 Volts , neutral & earthing link bar, flush/surface mounting complete all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 6 sqmm in service connections suspen- ded by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular →
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 10 sqmm in service connections suspen- ded by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular →
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 core 16 sq. mm nominal cross section in service connections
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 core 25 sq. mm nominal cross section in service connections
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 35 sq. mm nominal cross section in service connections
Supply and laying GI tubing, 40 mm dia, " light grade" ISI marked, laid in trenches / under road or floor / fixed alongwith pole / wall with suitable size MS clamps complete including taking out existing rusted GI tubing complete all as specified and as directed.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width incl cutting of road/path and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed.Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations.
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil (Soils) not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying of class B bricks for under ground cable protection as directed by Engineer- in - charge
M&L cement concrete 150 mm thick Type D-2, 1:3:6 (20 mm graded crushed stone aggregate as in repair of road/path cutting
Taking down carefully and sevicing to geyser of capacity 25/50 ltr of any make, taking out inner tank, heating elements, thermostate water water assy etc and descaling the deposits by scrapping and carrying out soldering/ brazing/gas welding to prevent the leakage, refilling of glass wool &refixing of parts including replacement of required number of stainless steel screws, nuts & bolts,assembled the the same after repair work and re-fixed its orginal place etc complete and all as specified and directed by Engineer-in-charge. Note – Glass wool and other spares required shall be measured & paid separately under respective item of this schedule..
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembled & fixed at site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Heating element 2 KW ISI Marked
Supply and fix in repairs Heating element 1.5 KW Make for item No121 &122 :- RECOLD / VENUS / GILCO / PREMIER / CHEETA /Bajaj/CROMPTON
Supply and fix in repairs Thermostat switch ISI Mark
Supply and fix in repairs Safety valve
Supply and fix in repairs Indicating Lamp Round /Square
Supply and fix in repairs heavy duty 45 cm long , 15mm bore wire wooven PVC connection pipe for hot and cold water with brass union both ends fixed to GI Pipe
Supply and fix in repairs Apparatus plate for 25 litre / Syphon Assy
Supply and fix in repairs Plug top 3-pin, 16 Amp
Supply and fix in repairs Rubber O ring /gaskit for 25 ltrs
Supply and fix in repairs Electric water storage Heater (vertical type Geysers) 25 Ltrs BEE 5 STAR, 230 volts AC single phase with and including grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement .Geysers to have glass lines tank, fero glass coated container,PUF insulation, glass coated heating element, 8 BAR rated pressurer, thermostat cut off etc.including cutting holes and making good the disturbed surface complete all as specified and as directed Make : Havells/Venus/AO Smith
S&F for replacement to unserviceable flexible PVC insulated lead in lieu of provided with new flexible PVC insulated sheathed copper conductor connection lead 3- core ,size 40/0.0076 cable suitable for y Complete all as specified and as directed by Engineer-in-Charge.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for inserting GI pipe upto 100 mm dia all as specified and directed.
Supply and laying GI tubing, 15 mm dia, " medium grade" ISI marked, laid in trenches / under road or floor / fixed alongwith pole / wall with suitable size MS clamps complete including taking out existing rusted GI tubing complete all as specified and as directed.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way SPN suitable for Minitature Circuit Breaker DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 6 way SPN suitable for Minitature Circuit Breaker DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed. Make Legrand/ABB/Indoasian/Siemens/C&S/Havells
Supply and fixing in repair Energy Meter tamper proof LED Display with out optical port , single phase , AC 230 Volts 10 to 60 Amps cap in position complete with incoming and outgoing cable connection with suiable size of copper cable and copper lugs complete all as specified and as directed Make L&T cat part No WM 301 BC 6D20 or equivalent in Scure Metre
Supply and fix in repair temper proof polycarbonate cover for single phase energy meter with non brakable glass in front
Supply and fixing in repair Energy Meter tamper proof LED Display with out optical port , three phase , AC 440 Volts 20 to 60 Amps cap in position complete with incoming and outgoing cable connection with suiable size of copper cable and copper lugs complete with tampre proof ploycarbonate enclosure with non breakable glass in front complete all as specified and as directed Make L&T / Scure Metre/HPL
Supply and fix in repair temper proof polycarbonate cover for three pahse energy meter with non brakable glass in front
Supply and fix decorative box type LED retrofit INVERTER fittings 22 watts complete with 04 hrs back up time, Cool white, (system lumen efficacy 100lm/watts and lumen output at battery not less than 50 lumens/watts) , CRI more than 80,operating voltage 230 V AC 50 HZ , opeating temperature (-10⁰ C to +50⁰C), glarefree, 0 UV radiation all as specefied and directed Make : Wipro/C&S/Bajaj/Halonix/Cromptom.
GS Engineers
Electromech Engineers
LONGIA ENGINEERS
Arun enterprises
M/S BALWINDER SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .