Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC COURT ROAD UTTARKASHI | L1 | Accepted-AOC Lowest Rates | |
| 2 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Price Bid not complied | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance JHAWAREDI POST KARBARI IDBI BANK COMPLEX SHIMLA ROAD DEHRADUN | - | Not Admitted-Fee/PreQual/Technical/Finance Price Bid not complied | |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Price Bid not complied | |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance T STATE BANJARAWALA DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Not Admitted-Fee/PreQual/Technical/Finance Price Bid not complied |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
28 Aug 2019, 5:00 pmClosed
Superintending Engineer
107, Nehru Colony, Phase-II, Dharampur, Dehradun
Internal Electrification of Degree College, Tyuni, Distt. Dehradun.
2019_pwd_19496_1
2235/7CB(I)-11/2019 Dt. 31.07.2019
Open Tender
Electrical Works
Item Rate
120 days
Tyuni Distt. Dehradun
Please refer Tender documents.
1 document required · 1 mandatory
₹3,540
Executive Engineer EM Div., PWD Dehradun
₹84,000
27 Mar 2021
7 Aug 2019
29 Aug 2019
7 Aug 2019
28 Aug 2019
7 Aug 2019
Amount
Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as required.Group C
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing 5/6 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required (for plug on box).
Supplying and fixing 3 pin 5/6 amp modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (for plug on box)
S/F of Telephone Socket outlet Modular type
S/F of TV antenna socket outlet Modular type
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. . (For Sept. light plugs).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(for PP)
Supplying and drawing 1X1.5 sqmm sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (For invertor)
Supplying and drawing following pair, 0.5 sq mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing following pair, 0.5 sq mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/recessed steel/ PVC conduit as required. 4 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
S/L of PVC pipe 20 mm.
S/L of PVC pipe 25 mm.
Supply and fixing of 2 module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supply and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
Supplying and fixing 8 way,DD single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
……..Do….but for 12 Way, DD
Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2.x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire.
.....Do..........but for 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
.....Do..........but for 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
.....Do..........but for 2 x 6 sq. mm + 1 x 6 sq. mm. earth wire
.....Do..........but for 2 x 10 sq. mm + 1 x 6 sq. mm earth wire
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supplying and fixing 40 Amp. rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
…….Do….. But for 63 AMP DP RCCB.
S/F of 40-63 Amp Four Pole 'C' curve MCB make Legrand.
S/F of 40-63 Amp double Pole 'C' curve MCB
S/F of 20 Amp. 240 V, SPN modular type A.C. socket outlet alongwith 20Amp "C" series SP MCB in surface/Recess complete with suitable size of GI box and cover plate complete.
S/F of hexagonal fan box
S/F of M.S. Drum for exhaust fan
S/L of Aluminium conductor PVC insulated armoured, served sheathed cable of following sizes Cat A laid in ground. 300 sqmm x 3.5 core
…...do…..for 150 sqmm x 3.5 core
…...do…..for 16 sqmm x 4 core
…...do…..for 10 sqmm x 4 core
S/F of palm or Plinth Al. tin plated cable socket(Lug) size 300 sqmm
……do….but for 150 sqmm
……do….but for 70 sqmm
……do….but for 16 sqmm
……do….but for 10 sqmm
S/F of Brass Gland 300 sqmm x 3.5 core
S/F of Brass Gland 150 sqmm x 3.5 core
S/F of Brass Gland 16 sqmm x 4 core
S/F of Brass Gland 10 sqmm x 4 core
Main-Panel: S.I.T.C. of powder coated compartment board made from 2mm thick CRCA sheet suitable for Floor mounting provided with 600 Amp. Strip Al. busbar Al. inter connection including making provision for earth bar separer neutral and connector for making outgoing and incoming cable/wires. Incoming : 400 Amp, 415 V Fp Mccb breaking capacity 36k ,1 No. (make Siemens Vt, Schneidler- NS L&T _D Sine. Outgoing :- 200 Amp, 415 V FP MCCB breaking capacity 25k ,2 No. WITH 1 No. 200 Amp FP ATS(Changeover) (make Siemens VT, Schneidler- NS L&T _D Sine
Sub-Panel: S.I.T.C. of powder coated compartment board made from 2mm thick CRCA sheet suitable for Floor mounting provided with 300 Amp. Strip Al. busbar Al. inter connection including making provision for earth bar separer neutral and connector for making outgoing and incoming cable/wires. Incoming : 200 Amp, 415 V Fp Mccb breaking capacity 25k ,1 No. (make Siemens Vt, Schneidder- NS L&T _D Sine. Outgoing :- 63 Amp, 415 V FP MCCB breaking capacity 16 k ,4 No. (make Siemens VT, Schneidler- NS L&T _D Sine
S/F of 1x 18-20 watt LED type tube fitting complete make Phillips/Havells/Cromption
S/F of 17 Watt slim LED of wall bracket light Make Phillips/Havells/Cromption/Wipro
S/F of Angle Holder complete in all respect
Supply of 7 Watt LED mirrior light fitting Make Phillips/Havells/Cromption/Wipro
S/F of Call Bell
S/O of 9 Watt LED bulb Make Phillips/Cromption/Havells/ Bajaj
S/F of 2'X2' 30-33 Watt,3000-33000 Lumens 5700-6500 K surface mounted complete in all respects Phillips, Havells, Bajaj, Cromption, Wipro.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_23359.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .