Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAdmitted-Finance 4 14 168 TRISHERIYU SALVIWADO PATAN PATAN GUJARAT 384265 UDYAM GJ 18 0001893 | PATAN | GUJARAT | 384265 | ₹2.7 L | L1 | Admitted-Finance |
| 2 | L2₹25.7 LAdmitted-Finance JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | ₹25.7 L | L2 | Admitted-Finance |
| 3 | L3₹28.7 LAdmitted-Finance PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | ₹28.7 L | L3 | Admitted-Finance |
| 4 | L4₹29.6 LAdmitted-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹29.6 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | - | - | Rejected-Technical Bidder does not have requisite category as per NIT. |
| Sl No | Description | Qty | Unit | m/s prakash enterprise L3 | OM ENTERPRISE L2 | SURESH ELECTRICALS L4 | shree chamunda enterprise L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for servicing of Window AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the Air conditioner fully functional & serviceable complete all as specified & directed by Engineer-in-Charge. | 15 | Each Job | 2,830 ₹42,450 | 2,580 ₹38,700 | 10,100 ₹1.5 L | 120 ₹1,800 |
| 2.00 | M&L for servicing of split AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 100 | Each Job | 3,775 ₹3.8 L | 3,300 ₹3.3 L | 5,000 ₹5 L | 20 ₹2,000 |
| 3.00 | M&L for servicing of split AC's of 2.0 Tonne capacity of any make , complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 50 | Each Job | 4,245 ₹2.1 L | 3,700 ₹1.9 L | 7,000 ₹3.5 L | 70 ₹3,500 |
| 4.00 | M&L for servicing of Cassette AC's of capacity 2.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 2 | Each Job | 6,850 ₹13,700 | 6,200 ₹12,400 | 8,500 ₹17,000 | 100 ₹200 |
| 5.00 | M&L for servicing of Cassette AC's of capacity 3.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 2 | Each Job | 7,585 ₹15,170 | 6,600 ₹13,200 | 20,000 ₹40,000 | 100 ₹200 |
| 5.01Note for item no 1 to 5:- (a) The above item includes labour charges tools/gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints for a period of one year c) Preventive Maintenance 3 visit in a year (qtrly based ) to carry out 2 dry & 1 wet serivice from Local Authorised Service Centre as approved by GE (b) The cost of spares such as Fan Motor/Louver Motor/ Gas Charging/ Capacitors & Relay/Thermostat Switch / Selector Switch / Air Filter / Remote Control / Fan & Blower / Evaporator and Condenser coil / Air Deflector / louvers/compressor will be measured & paid separately under relevant item of the schedule. | |||||||
| 6.00 | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the window type air conditioner of 1.5 Ton capacity complete all as specified and directed. | 5 | Each Job | 2,940 ₹14,700 | 2,780 ₹13,900 | 1,500 ₹7,500 | 200 ₹1,000 |
| 7.00 | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner upto 1.5 Ton capacity complete all as specified and directed. | 50 | Each Job | 3,235 ₹1.6 L | 2,910 ₹1.5 L | 1,600 ₹80,000 | 60 ₹3,000 |
| 8.00 | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner of 2.0 Ton capacity complete all as specified and directed. | 20 | Each Job | 3,675 ₹73,500 | 3,400 ₹68,000 | 2,000 ₹40,000 | 90 ₹1,800 |
| 9.00 | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 2 Ton capacity complete all as specified and directed. | 2 | Each Job | 4,400 ₹8,800 | 1,060 ₹2,120 | 2,100 ₹4,200 | 60 ₹120 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
23 May 2026, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
REPAIR AND MAINT OF CERTAIN COOLING AND REFRIGERATION APPLIANCES AND ALLIED WORK AT VARIOUS LOCATIONS OF NAVAL STATIONS
2026_MES_762242_1
9372/PBR/E8
Open Tender
Electrical and Maintenance Works
180 days
GE Navy Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹52,000
Yes
1 Jun 2026
25 Apr 2026
25 May 2026
25 Apr 2026
23 May 2026
10 May 2026
25 Apr 2026 - 9 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for servicing of Window AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the Air conditioner fully functional & serviceable complete all as specified & directed by Engineer-in-Charge. | 15 | Each Job | - | - |
M&L for servicing of split AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 100 | Each Job | - | - | |
M&L for servicing of split AC's of 2.0 Tonne capacity of any make , complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 50 | Each Job | - | - | |
M&L for servicing of Cassette AC's of capacity 2.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 2 | Each Job | - | - | |
M&L for servicing of Cassette AC's of capacity 3.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 2 | Each Job | - | - | |
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the window type air conditioner of 1.5 Ton capacity complete all as specified and directed. | 5 | Each Job | - | - | |
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner upto 1.5 Ton capacity complete all as specified and directed. | 50 | Each Job | - | - | |
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner of 2.0 Ton capacity complete all as specified and directed. | 20 | Each Job | - | - | |
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 2 Ton capacity complete all as specified and directed. | 2 | Each Job | - | - | |
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 3 Ton capacity complete all as specified and directed. | 3 | Each Job | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
9372T_Gen_SC_PS.pdf
Tender Documents • 1.17 MB
BOQ_853809.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid