Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.8 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L-1 | Accepted-AOC Tender Accepted due to lowest and quoted reasonable rates | |
| 2 | L-2₹18.1 L+₹1.3 L (7.71%)Rejected-Finance | L-2 | Rejected-Finance Higher side quoted amount | |
| 3 | L-3₹19.6 L+₹2.9 L (17.0%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L-3 | Rejected-Finance Higher side quoted amount | |
| 4 | L-4₹19.9 L+₹3.2 L (18.9%)Rejected-Finance | L-4 | Rejected-Finance Higher side quoted amount | |
| 5 | Rejected-Technical 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
26 Jul 2022, 6:00 pmClosed
CWE KHUMBATHANG
CWE KHUMBATHANG
COMPREHENSIVE MAINT OF CHS AND SOLAR WATER HEATING DEVICES AT KHUMBATHANG UNDER GE KHUMBATHANG
2022_MES_533330_1
80051/37/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE KHUMBATHANG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE KHUMBATHANG
₹50,000
25 Aug 2022
24 Jun 2022
27 Jul 2022
24 Jun 2022
26 Jul 2022
8 Jul 2022
Amount
M&L for detection of leakage, rectification of leakage by means of water method, making the system leak proof and serviceable complete all as specified and directed by Engr-in-Charge.
M&L for removing / opening of electric boiler control panel for checking serviceable state of control wiring and switches which includes replacement of minor parts (control wiring and other necessary items for making the panel serviceable) complete all as specified and directed by Engr-in-Charge.
Dismantling of mono block electric motor set of capacity 3 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC complete all as specified and directed by Engr-in-Charge. Note : Transpotation charge of motor from site to workshop and back is deemed to be included in the item rate.
Dismantling of mono block electric motor set of capacity 5 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC complete all as specified and directed by Engr-in-Charge. Note : Transpotation charge of motor from site to workshop and back is deemed to be included in the item rate.
Supply only glycol / coolant alongwith the necessary additives and inhibitor in cognition and supplied in barells complete all as specified and directed by Engr-in-Charge.
S&F in replacement of heater bank of capicity 25 KW for electric based central heating system all as specified and directed incl taking down old one complete all as specified and directed by Engr-in-Charge.
S&F in replacement of heater bank of capicity 7 KW for electric based central heating system all as specified and directed incl taking down old one complete all as specified and directed by Engr-in-Charge.
S&F in repair heater bank of capicity 5 KW for electric based heating incl thermostat of suitable capacity and other connected accessories incl taking down old one complete all as specified and directed by Engr-in-Charge.
S&F in repair of monoblock pump of capacity 1 HP with all accessories including water seal complete all as specified and directed by Engr-in-Charge.
S&F in replacement of burner fuel pipes incl taking down old one complete all as specified and directed by Engr-in-Charge.
S&F in replacement of oil filter (super fine glass type) of suitable for burner 1 lakh kilo calorie as per requirement at site incl taking down old one complete all as specified and directed by Engr-in-Charge.
Labour for complete decarbonising of boilers including replacement of damaged refractory complete all as specified and directed by Engr-in-Charge.
S&F in replacement of pressure switch incl taking down old one complete all as specified and directed by Engr-in-Charge.
Repair of body leakage of electric Hamam of capacity 45 Ltr ,steel body rectangular/round type with thermostates and auto cut and change of burnt heating element complete all as specified and directed by Engr-in-Charge.
S&F in repair flexible PVC all weather/ crack proof pipe of size 20 mm dia complete all as specified and directed by Engr-in-Charge.
Repair of body leakage of electric hamam of capacity 25 Ltr,steel body rectangular/round type with thermostates and auto cut and change of burnt heating element complete all as specified and directed by Engr-in-Charge.
M&L for replacement of damaged nitrile insulation of 19 mm thick over pipes of CHS of any size as required at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of damaged asbestos rope insulation of 10 mm thick over Duct (outside) of CHS 200x200 mm size as required at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of damaged Chimney for 25000 K/cal Model AH-25 AHU unit of make alfa therm length as required at site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of damaged aluminium cladding of any pipe size complete as required at site complete all as specified and directed by Engr-in-Charge.
Labour only for opening the Oil based boiler, dismantaling the accessories and cleaning the boiler including replacement of necessary minor accesories as per site requirement complete all as specified and directed by Engr-in-Charge.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirant R-134a brazing and bring to be serviceable condition and testing suitable for 500 ltr Deep Freezer complete all as specified and directed by Engr-in-Charge.
S&F in replacement of reciprocating /rotary compressor including refilling of refrigirent R-134 a, brazing and bring to be serviceable condition and testing suitable for 300 ltr Deep Freezer complete all as specified and directed by Engr-in-Charge.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent, brazing and bring to be serviceable condition and testing suitable for 200 tr Deep Freezer complete all as specified and directed by Engr-in-Charge.
S&F in replacement of contactor A-26-30-10, 13 NO in repair AC 3 phase complete all as specified and directed by Engr-in-Charge.
S&F in replacement of contactor MNX 9, in repair AC 3 phase complete all as specified and directed by Engr-in-Charge.
M&L for descaling of radiator panel associated with CHS installed at signal center and A Mess complete all as specified and directed by Engr-in-Charge.
Labour for servicing of fan coil unit of indoor units, removing dust / other remains with suitable liquid complete all as specified and directed by Engr-in-Charge.
S&F in replacement of wall mounted fan coil unit of capacity 1.5 TR (4500 K Cal/Hrs 600 Cfm) complete all as specified and directed by Engr-in-Charge.
S&F in replacement of wall mounted fan coil unit of capacity 1.0 TR (3000 K Cal/Hrs 600 Cfm) complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sequence control of boiler complete all as specified and directed by Engr-in-Charge.
S&F in replacement of iginition transformer of boiler complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Nozzle 60 degree 2 GPH of boiler complete all as specified and directed by Engr-in-Charge.
S&F in replacement of iginition electrode complete all as specified and directed by Engr-in-Charge.
M&L for replacement of fuel pump suitable for 1 lakh kilo calories burner assembly complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of wall mounted type hecco panel of size 600mm x 300mm x 18mm or rating of 65W each, complete, all as specified and directed by Engr-in-Charge.
S&F in replacement of heat pillar rod of capacity 750 Watts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of heating element AC 230 volt, triangle/round type of rating 1500 watt suitable for geyser/Hamam as per sample, complete all as specified and directed by Engr-in-Charge.
Supply only heating element AC 230 volt, triangle/round type of rating 2000 watt suitable for geyser/Hamam as per sample ,complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC insulated stranded copper conductor size 2.5 Sqmm 2 core for connection anti freezing tracer complete all as specified and directed by Engr-in-Charge.
Material and labour for repair of Water heater storage type, electric based,capacity 25 litres rate included in change of themostat,stainless steel tank,heating element complete all as specified and directed by Engr-in-Charge.
Repair of Metal Heat Pillar of capacity 2x750 Watts as per sample complete all as specified and directed by Engr-in-Charge.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 63 KW electric boiler complete all as specified and directed by Engr-in-Charge.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 45 KW electric boiler complete all as specified and directed by Engr-in-Charge.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 75 KW electric boiler complete all as specified and directed by Engr-in-Charge.
M & L for change of submain wiring 2 core 4.0 sqmm phase and neutral incl earth wire of 2.5 sqmm in existing conduit and PVC batten complete all as speciifed and directed by Engr-in-Charge. Note: 2 runs of 4.0 sqmm phase and neutral and 01 core of 2.5 sqmm as earth wire will be treated as one unit.
Supply & Fixing in replacement of Ball valve of 20 mm dia complete all as specified and directed by Engr-in-Charge.
M&L for replacement of damaged relay 16 Amps MN-2 Complete all as specified and directed by Engr-in-Charge.
M&L for replacement of unsv diesel fired burner of heat output capacity 25000 Kcal/hr for standalone CHS complete all as specified and directed by Engr-in-Charge.
M&L for replacement of unsv diesel fired burner of heat output capacity 50000 Kcal/hr for standalone CHS complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in repair 500 LPD solar water tank complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in repair solar plate gasket complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in repair borosilicate tube suitable for 500 LPD solar water heating system complete all as specified and directed by Engr-in Charge.
Supply & Fixing in repair flat plate collector(FPC) suitable for 500 LPD solar water heating system complete all as specified and directed by Engr-in-Charge.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 85,500.00 and any other reduction if any from quoted amount.
M/S LIBE & CO
KASHMIR FAIR DEAL SERVICES
osho traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .