Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹2.2 L+₹8,540.50 (4.11%)Rejected-Finance GROUND FLOOR THAKUR COMPLEX BASANTPUR | BASANTPUR | SHIMLA | HIMACHAL PRADESH | 171018 | 2 | Rejected-Finance L2 | |
| 3 | 3₹2.2 L+₹10,745.50 (5.17%)Rejected-Finance 00 AGRA AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | 3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Sh. Ashok Kumar Prop. M/S A.K. Guleria Construction L1 | Pawan Kumar L2 | RAKESH KUMAR L3 |
|---|---|---|---|---|---|---|
| 1.00Excavation in foundation and trenches etc. ( for pipe and pits) up to all depths and in all kinds of soils such as pick work, pick jumper work, saturated soil including bailing or pumping out of water, blasting in soft/ hard rock, chiseling/wedging out of rock where blasting is prohibited, in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking timbering and dewatering wherever required, stacking usable and unusable materials/ soils separately and after laying, jointing and testing of pipes, returning the usable soils in 15 cm layers by ramming and watering and then disposing of all surplus excavated soil / unusable materials as directed within all leads and lifts including restoration of un-metalled surfaces to its original condition and including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads and lifts as per the direction of the Engineer-in-charge | ||||||
| 1.01 | Pick works. | 50.27 | Cum | 350 ₹17,594.5 Lowest | 380 ₹19,102.6 | 400 ₹20,108 |
| 1.02 | Pick jumper work. | 111.38 | Cum | 450 ₹50,121 Lowest | 480 ₹53,462.4 | 500 ₹55,690 |
| 2.00Dismentalled of GMS pipe from trenches (earth work in trenches to be measured and paid for separately). | ||||||
| 2.01 | GI pipe 40mm dia (RD 855 to 950) Kandrour Dhar to village Chakli Nr. Benla Brahmna | 95 | Rmt | 45 ₹4,275 | 46 ₹4,370 | 44 ₹4,180 Lowest |
| 2.02 | GI pipe 50mm dia (RD 855 to 949) Village Chakli Nr. Benla Brahmna). | 94 | Rmt | 54 ₹5,076 | 56 ₹5,264 | 53 ₹4,982 Lowest |
| 2.03 | GI pipe 80mm dia (RD 965 to 992) Kandrour Dhar to Chatter tank 1st tank). | 27 | Rmt | 62 ₹1,674 Lowest | 70 ₹1,890 | 65 ₹1,755 |
| 2.04 | GI piope 125mm dia (RD 945 to 995) Kandrour Dhar to Chatter 2nd tank | 50 | Rmt | 110 ₹5,500 | 120 ₹6,000 | 109 ₹5,450 Lowest |
| 3.00Re-laying, Jointing and testing galvanized mild steel tube in trenches of following dia. including tube fittings such as bends, tees, reducers, unions etc. complete and to the entire satisfaction of the Engineer-in-charge (earth work in trenches to be measured and paid for separately). | ||||||
| 3.01 | GI pipe 40mm dia (RD 855 to 949) | 94 | Rmt | 42 ₹3,948 Lowest | 50 ₹4,700 | 45 ₹4,230 |
Tender Value
₹1.3 L
EMD Value
₹2,620
Closing Date
20 Aug 2025, 11:00 amClosed
Executive Engineer
Jal Shakti Division Bilaspur
Restoration of rain damages of LWSS Nog Chandpur in Tehsil Sadar District Bilaspur (SH Alignment change with dismantling and relaying of gravity main of various dia from different storage tank at various locations due to construction work of local ro
2025_HPIPH_111747_1
BLP-BLP-0736-NIT No. 5450-551 Dated 04/08/2025
Open Tender
Civil Works
Item Rate
Sub Division Bilaspur Section Kandrour
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹2,620
8 Dec 2025
8 Aug 2025
20 Aug 2025
8 Aug 2025
20 Aug 2025
8 Aug 2025
Amount
Excavation in foundation and trenches etc. ( for pipe and pits) up to all depths and in all kinds of soils such as pick work, pick jumper work, saturated soil including bailing or pumping out of water, blasting in soft/ hard rock, chiseling/wedging out of rock where blasting is prohibited, in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking timbering and dewatering wherever required, stacking usable and unusable materials/ soils separately and after laying, jointing and testing of pipes, returning the usable soils in 15 cm layers by ramming and watering and then disposing of all surplus excavated soil / unusable materials as directed within all leads and lifts including restoration of un-metalled surfaces to its original condition and including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads and lifts as per the direction of the Engineer-in-charge
Pick works.
Pick jumper work.
Dismentalled of GMS pipe from trenches (earth work in trenches to be measured and paid for separately).
GI pipe 40mm dia (RD 855 to 950) Kandrour Dhar to village Chakli Nr. Benla Brahmna
GI pipe 50mm dia (RD 855 to 949) Village Chakli Nr. Benla Brahmna).
GI pipe 80mm dia (RD 965 to 992) Kandrour Dhar to Chatter tank 1st tank).
GI piope 125mm dia (RD 945 to 995) Kandrour Dhar to Chatter 2nd tank
Re-laying, Jointing and testing galvanized mild steel tube in trenches of following dia. including tube fittings such as bends, tees, reducers, unions etc. complete and to the entire satisfaction of the Engineer-in-charge (earth work in trenches to be measured and paid for separately).
GI pipe 40mm dia (RD 855 to 949)
GI pipe 50mm dia (RD 855 to 948)
GI pipe 80mm dia (RD 965 to 991)
GI pipe 125mm dia (RD 945 to 994)
Laying, Jointing and testing galvanized mild steel tube in trenches of following dia. including tube fittings such as bends, tees, reducers, unions etc. complete and to the entire satisfaction of the Engineer-in-charge (earth work in trenches to be measured and paid for separately).
GI pipe 40mmdia (RD 949 to 973)
GI pipe 50mmdia New piope RD 948 to 972)
GI pipe 80mm dia (New pipe RD 991 to 1015)
GI pipe 125mm dia (New pipe RD 994 to 1102)
Providing circumferential butt welded joints by electrical arc welding to the varous dia GI pipe as per conforming to IS: 3183-2007 (latest upto date amendements of grade and wall thickness as specified below welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications by using welding electrodes of 2.5mm to 6.3mm of Advani Orelon (Adore)-CITOJET/ESAB make, conforming to IS: 814-1991 at site of work complete in all respect, including manual/ mechanical handling of pipe in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
GI pipe 40mm dia (Kandrour Dhar to village Chakli nr Benla Brahmna (Bhood, Chakli lower, Nr Gas Plant.)
GI pipe 50mm dia (Village Chakli Nr. Benla Brahmna (Har, Patwar Khana, Shira, Gurkul)
GI pipe 80mmdia Kanrour Dhar to Chatter tank 1st (Lower Chakli)
GI pipe 125mm dia Kandrourt Dhar to Chatter 2nd tankNr. Gas Planty Bhood Benla
Pawan Kumar (BID ID -543722)
RAKESH KUMAR (BID ID -543717)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .