Loading…
Loading…
Tender Value
₹21.4 Cr
EMD Value
₹12.2 L
Closing Date
31 Mar 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual Contractual Turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Definition of similar nature of works: "Any signal interlocking works involving EI or RRI or PI or IBS or LC gate interlocking or UFSBI or Track Circuit AFTC or (SSDAC or MSDAC or HA-SSDAC) or Automatic Signaling."
9 conditions · 5 needing a document upload
1. Earnest money deposit (scanned copy of the instrument to be attached) 2. Experience certificate (scanned copy of the credentials to be attached) 3. Turn over details (scanned copy of the attested certificates from the employer/ client, audited balance sheet duly certified by the chartered accountant etc., to be attached) 4. Details of strength of staff employed
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
All works tenders or service tenders invited by railways through e-tendering on IREPS, having advertised value of Rs 10 lakh and above, contractors are eligible to take payment from Railways through a Letter of credit (LC) arrangement. (Ref: RB letter no.2018/CE-I/CT/9 dated 04.06.18) (i) For all the tenders having advertised cost of Rs 10 lakh or above, the contractor shall have the option to take payment from Railways through a letter of credit (LC) arrangement. (ii) T h i s option of taking payment through L C arrangement h a s t o be exercised in !REPS (Indian Railway Electronic Procurement System - the e-application on which tenders are called by Railways) by the tenderer at the time of bidding itself, and the tenderer shall affirm having read over and agreed to the terms and conditions of the LC option.(iii) The option so exercised, shall be an integral part of the bidder's offer. (iv) T h e above option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, thereafter, during execution of contract. (v) In case tenderer opts for payment through LC, necessary procedure for LC mode of payment shall be followed to deal release of payment through LC:
Provision of indoor and outdoor Signalling and Telecommunication arrangements at Thrissur station in connection with shifting of S&T accommodation as part of Re- development of Thrissur Railway station in Thiruvananthapuram division of Southern Railway.
ERS-SG-CN-01-2026
ERS-SG-CN-01-2026
Open
Works - General
12 Months
Ernakulam, Kerala
₹0
₹12.2 L
31 Mar 2026
7 Mar 2026
17 Mar 2026
327 items across 7 schedules · ₹17,88,08,472.89 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of fan less embedded industrial grade computers (Similar to Moxa V2406 or better) with a l l accessories such as key board, mouse, antivirus etc. o f industrial g r a d e as per approved Specification as recommended by latest RDSO Specification(RDSO/SPN/192 or 203 or latest) for EI | Numbers | 3.00 | 3,75,562.03 | 11,26,686.09 |
| 2 | Supply of Power Supply arrangement for VDU and Embedded PC. This includes supply of 2 N o s o f 110VDC/24DC, 10A DC-DC converter a n d 2 N o s of 110VDC/110V AC, 500VAInverter in (1+1) configuration.(as per Technical Specification enclosed) | Set | 3.00 | 2,14,096.98 | 6,42,290.94 |
| 3 | Supply of Double Key Lock | Numbers | 3.00 | 481.77 | 1,445.31 |
| 4 | Supply and Installation of work space as per enclosed drawing No PROJ/SG/MS/70/2019 - work space (as approved by engineer in charge) with control desk for 2 monitors, 2 operators & one module to be provided for storage - should include space for housing Two nos of Embedded PCs, 2 nos FDMS and their Power supply arrangement for with proper ventilation with two chairs (as per Drawing enclosed or as per site requirement) | Numbers | 1.00 | 9,48,672.1 | 9,48,672.1 |
| 5 | "Training of Railway Personnel in installation, commissioning, testing, troubleshooting and in diagnosing faults u s i n g diagnostic tools/flow charts i n c l u d i n g s u p p l y of necessary documents. (Per Unit= 60 Man Days)" | Per Unit | 1.00 | 72,995.54 | 72,995.54 |
| 6 | " C a r r y i n g o u t A u t o m a t i c Factory Acceptance test for a n y station having Distributed EI configuration" | Station | 1.00 | 3,05,105.92 | 3,05,105.92 |
| 7 | "Carrying out Automatic Site Acceptance test for any station having Distributed EI configuration" | Station | 1.00 | 9,73,868.46 | 9,73,868.46 |
| 8 | P r e p a r a t i o n o f c i r c u i t s , location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall b e prepared in A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully a n d submit o n e copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. a) Preparation of soft copy in AUTO CADD from A3 size hard copy | Sheet | 350.00 | 218.3 | 76,405 |
| 9 | P r e p a r a t i o n o f c i r c u i t s , location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall b e prepared in A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully a n d submit o n e copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways.c)Preparation of soft copy in AUTO CADD from U size hard copy | Sheet | 4.00 | 1,548.45 | 6,193.8 |
| 10 | "Supply, of Datalogger with 512 Digital Input and 32 Analog Input as per RDSO specification No. IRS:S-99/2006 Amdt 3 (or) latest w i t h p o w e r supply arrangements. (This work does not includes wiring of inputs from Relay to Intermediate tag block & from intermediate t a g b l o c k t o Datalogger equipment)" | Numbers | 3.00 | 4,46,627.2 | 13,39,881.6 |
| 11 | "Supply o f Fault Analysis Terminal for analysis of fault and generating reports for Datalogger installed a t stations. As per Technical Specifications." | Numbers | 1.00 | 54,723.27 | 54,723.27 |
| 12 | Supply of Protocol Converter suitable for Electronic Interlocking system equipment | Numbers | 1.00 | 68,051.41 | 68,051.41 |
| 13 | "Installation o f Datalogger o f Capacity 512 Digital and 32 Analog. This includes transportation o f m a t e r i a l s t o Site location and provision o f Ladder and c a b l e trough arrangements including connection t o the BRC earth. Also includes carrying out of pre- commission checklist and Networking of datalogger. (This s c h e d u l e doesn't c o v e r w i r i n g and preparation of simulation chart)" | Numbers | 3.00 | 29,500 | 88,500 |
| 14 | "Preparation o f Simulation Database which includes chart preparation for on- line and off-line simulation for display in V D U for station o r A u t o section. (Per Unit = Per Datalogger)" | Per Unit | 1.00 | 59,000 | 59,000 |
| 15 | Wiring o f Relay Inputs t o Wago Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit | 600.00 | 285.86 | 1,71,516 |
| 16 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary Wagos required is included as per schedule | Numbers | 48.00 | 285.86 | 13,721.28 |
| 17 | Installation o f Fault Analysis Terminal (for analysis o f f a u l t a n d generating r e p o r t s for Datalogger installed at stations) | Numbers | 1.00 | 23,452.83 | 23,452.83 |
| 18 | Preparation o f statio n s p e c i fi c Train Arrival and departure logics for a six road station or less | Numbers | 1.00 | 1,63,559.06 | 1,63,559.06 |
| 19 | C a r r y i n g o u t E m b e d d e d software modification i n D a t a l o g g e r to communicate with the data entry terminal of the ASM and pass the information through the datalogger network. | Numbers | 1.00 | 32,711.81 | 32,711.81 |
| 20 | C a r r y i n g o u t E m b e d d e d software modification in (1) FEP in control office and (2) CMU in control office, t o accept and transfer the relevant station data to a client PC | Numbers | 1.00 | 1,36,299.22 | 1,36,299.22 |
| 21 | Supply and Provision of Earthing a s per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed) | Numbers | 20.00 | 28,118.51 | 5,62,370.2 |
| 22 | Supply and Installation of Copper tape of size 25mm x 3mm for Down conductor from Franklin Rod to Maintenance free earth. This work includes installation of insulated stand-offs a t e v e r y 1 Mtr. interval for fixing the Copper tape. This work also includes Exothermic welding o f Copper tape t o the Franklin rod and the maintenance free earth for high conductivity. (All the materials required for the above work shall be supplied by the Contractor) | Metre | 200.00 | 690.54 | 1,38,108 |
| 23 | " S u p p l y a n d p r o v i s i o n o f Earthing arrangements for EI/MSDAC buildings as per RDSO specifications a s required for the EI system along with supply of all required materials. Earthing s h a l l be carried out as per RDSO/SPN/197/2008 and RDSO Lr .No STS/L/SSI/CA/US&S Dt 2 6 . 0 7 . 2 0 1 1 forTypical Earthing connections for EI. Painting of earthing diagram as replica of the ground on backside wall o f relay room a s p e r the instruction o f Site In-charge.(Per unit= Per goomty/station)" | Per Unit | 3.00 | 2,91,723.2 | 8,75,169.6 |
| 24 | Supply o f earth electrodes (G I) a s per Drg no SG/CN/02/13 | Numbers | 95.00 | 1,618.75 | 1,53,781.25 |
| 25 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 95.00 | 1,707.55 | 1,62,217.25 |
| 26 | "Full Location: Supply and fixing of GI Flat of size 1050x25x3mm a s given in enclosed drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer o f 23set. B ) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 70.00 | 1,370.66 | 95,946.2 |
| 27 | "Half Location: Supply and fixing of GI Flat of size 550x25x3mm a s given in enclosed drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer o f 23set. B ) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 10.00 | 846.75 | 8,467.5 |
| 28 | Supply o f 16-Channel E a r t h Leakage Detector a s p e r R D S O Specifications RDSO/SPN/256/2002 or latest | Numbers | 3.00 | 1,70,020 | 5,10,060 |
| 29 | Supply and Provision of HRC Fuse ( base and carrier with 4/6/10/16/20A/32 A fuse as per t h e l o a d condition at location boxes, cable huts etc . a s per approved circuit diagram. This work also includes painting of particulars of HRC fuse block installed in power panel instructed by Railway representative at site. (HRC fuse block, Fuses, wires, Cu. l u g s a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor.) | Numbers | 150.00 | 459.97 | 68,995.5 |
| 30 | Supply of Power Panel for IPS Room (using phynolic sheet 1200mm x 1200mm x 10mm and erecting i t using M S angles 25mm x 25mm x 6mm and fixing of meters, stabilizer and ammeter by pass switches, HRC fuse blocks, PBT terminals 60mm centre and connecting t h e p o w e r equipments t o the power panel a s per approved power diagram, in the power room.) | Numbers | 3.00 | 31,873.7 | 95,621.1 |
| 31 | Supply of Stackable type VRLA batteries 2V, 200Ah - 1 c e l l a s p e r RDSO Specifications IRS S: 93/96 with Amnd 1 or latest | Numbers | 120.00 | 4,074.88 | 4,88,985.6 |
| 32 | "Supply, installation and wiring of 230/24V - 1A transformer rectifier conforming to RDSO spec. IRS S 91/2014 with latest Amendment in power room for LVR" | Numbers | 1.00 | 12,335.32 | 12,335.32 |
| 33 | Supply of IPS to suit 4 Line RE station as per RDSO Specifications RDSO/SPN/165 or latest, ( T h i s s c h e d u l e d o e s not include Batteries) As per drawing enclosed | Numbers | 3.00 | 12,76,951.75 | 38,30,855.25 |
| 34 | Supply o f L o w maintenance secondary cells of t h e following capacities with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V-80AH capacity | Numbers | 156.00 | 3,379.2 | 5,27,155.2 |
| 35 | Supply o f L o w maintenance secondary cells of t h e following capacities with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document.d)Supply of Secondary cells - 2V-200AH capacity | Numbers | 60.00 | 7,040 | 4,22,400 |
| 36 | Supply of track feed battery charger IRS:S 89-2013 | Numbers | 40.00 | 4,375.25 | 1,75,010 |
| 37 | Supply of 'B type choke IRS:S 65-83 | Numbers | 80.00 | 2,855.6 | 2,28,448 |
| 38 | Supply o f Modular Terminal B l o c k of 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories a s p e r RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest. | Numbers | 2100.00 | 194.95 | 4,09,395 |
| 39 | Supply of DIN channel for the terminal | Metre | 16.00 | 344.87 | 5,517.92 |
| 40 | S u p p l y o f E N D p l a t e s f o r modular terminal block | Numbers | 131.00 | 36.86 | 4,828.66 |
| 41 | S u p p l y o f E N D c l a m p f o r modular terminal block | Numbers | 120.00 | 26.35 | 3,162 |
| 42 | Supply o f operating tool, screw driver and stripper for modular terminal. These tools shall be of Wago/Phoenix make or similar and model suitable for the modular terminal supplied | Numbers | 1.00 | 12,246.29 | 12,246.29 |
| 43 | "Supply of distilled water plant similar to'KILBURN' make capacity 3.5 to 4.5 Lits. per hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor" | Numbers | 1.00 | 25,774.2 | 25,774.2 |
| 44 | "Installation of distilled water plant with provision o f w a t e r s u p p l y connection from water t a p t o w a t e r t a n k , water tank to distilled water plant using G.I Pipes 25mm dia and with regulating valve s, provision of separate power supply s o c k e t a n d wiring. This work includes fixing of 2 Nos. of rails on the w a l l a n d grouting a s instructed by Railway representative at site. (Cut rails will be supplied by Railways)." | Numbers | 1.00 | 11,745.65 | 11,745.65 |
| 45 | Installation of 16-Channel Earth Leakage Detector. This includes transportation of materials t o Site location and provision of cable trough arrangements including connection to the BRC earth. Also includes carrying out of pre-commission checklist. | Numbers | 3.00 | 17,586.67 | 52,760.01 |
| 46 | Commissioning of IPS, this schedule includes arrangement o f O E M engineer f o r checking the Installation and carrying out adjustments of IPS modules a n d submission o f Pre- commissioning checklist | Set | 3.00 | 59,000 | 1,77,000 |
| 47 | Installation, wiring and testing of IPS as per RDSO Specification No. RDSO /SPN /165 or latest.This w o r k includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This also includes wiring o f a l l modules, proper earthing of equipments and all other w o r k s c o n n e c t e d f o r t e s t i n g and commissioning o f the same. Necessary p o w d e r e d c o a t e d A lu m in iu m ladder arrangements including cable trench, pipes, bolts, a n d other accessories is included in this schedule.[Earthing is not covered under this schedule] | Set | 3.00 | 77,160.07 | 2,31,480.21 |
| 48 | Fixing o f Modular terminal block/fuse block along w i t h accessories with provision of fixing h o l e s o n hylam sheet/side angles of Location B o x and fixing by Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal | Numbers | 2100.00 | 28.97 | 60,837 |
| 49 | Supply o f 2 4 C o r e x 1 . 5 Sq.mm PVC i n s u l a t e d Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre 77000.00 | — | 388.15 | 2,98,87,550 |
| 50 | Supply of 12Cx1.5 SQMM PVC insulated Armoured, unscreened underground Railway Signalling copper cable a s per IRS: S-63/2014 REV.4 | Metre 23000.00 | — | 215.92 | 49,66,160 |
| 51 | "Supply o f 2x2.5 sq.mm P V C insulated Armoured, unscreened, underground Railway Signalling Copper cable a s per spec IRS.S.63/2014(Rev.4.0) or latest" | Metre | 9000.00 | 98.76 | 8,88,840 |
| 52 | S u p p l y o f Underground j e l l y fi l l e d 6 QUAD, 0.9MM D i a a s p e r spe c IRS:TC 30-05 with amd 5 or latest | Metre 25000.00 | — | 301.05 | 75,26,250 |
| 53 | Supply of 24 Fibre armoured OFC cable as per R D S O Specification RDSO/SPN/TC/ 110/2020 Rev. 0 or latest | Metre | 6000.00 | 95.23 | 5,71,380 |
| 54 | Supply of Polythene Insulated Polythene S h e a t h e d a r m o u r e d J e l l y Filled Telephone Cable with Poly-AL Moisture Barrier, 10 Pairs, 0.63 MM Conductor Diameter as per RDSOSpecification No. IRS:TC-41/97 with amendment 1 or latest | Metre | 1000.00 | 123.9 | 1,23,900 |
| 55 | Supply of UTP Cable /CAT6/6A cable ETL or UL or CE3P certified panduit or Systimax or R&M o r A M P o r Molex or Krone Or D-LinkMakes | Metre | 300.00 | 34.73 | 10,419 |
| 56 | "Supply of 10way Annunciator with Push button switches and having conference facility. M o d e l N o A M - 1 0 s i m i l a r to Epsilon, Telelinks or better" | Numbers | 2.00 | 17,790.89 | 35,581.78 |
| 57 | Supply a n d provision o f normal joint using Thermo shrink jointing kit (RDSO s p e c s No TC/77/2012 ( Re v. 3 ) with amendment No.1&2 o r latest.& jointing k i t t o be inspected b y RDSO) f o r 4/6 q u a d cable normal j o i n t . The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing t h e same after completion of cable joint as per the instruction of Railway representative at site. | Numbers | 10.00 | 4,628.91 | 46,289.1 |
| 58 | Supply and installation of 24 Fibre Joint enclosure f o r armoured optic a l fibre cable conforming t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers | 4.00 | 13,647.37 | 54,589.48 |
| 59 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative a t site.) as per drawing enclosed | Numbers | 300.00 | 262.65 | 78,795 |
| 60 | Preparation of Cement concrete for covering of GI Pipes/cables. Providing & Laying in position cement concrete of specified proportion including c o s t of cement, centering a n d shuttering with 1:3:6 composition 1 Cement: 3 Sand: 6 grade stone aggregate 25mm nominal size) (Cement, M-Sand, stone jelly of 25mm and all o t h e r m i s c materials r e q u i r e d f o r the work should be supplied by Contractor). | cum | 50.00 | 9,361.46 | 4,68,073 |
| 61 | Laying o f STP/OFC/Power Cable/ switch board (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case c a p i n g and clamping on the wall/Roof tops/ Shelters with suitable clamping a n d hose t o be provided where ever bends/ curves (PVC c o n d u i t / Case capping and other accessories to be supplied by the contractor) | Metre | 300.00 | 37.3 | 11,190 |
| 62 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 900.00 | 64.1 | 57,690 |
| 63 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs a n d t o a width o f 0 . 3 Mtrs. (Laying of cables is not included in this schedule.) | Metre | 100.00 | 32.05 | 3,205 |
| 64 | Excavation of trench along route of existing cable duct, opening the slabs to accommodate additional c a b l e laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives a t s i t e . ( L a y i n g of cables is not included in this schedule.) [Cement,M Sand and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 1100.00 | 161.92 | 1,78,112 |
| 65 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming and consolidating i t a s p e r the instructions of Railway representative at site after l a y i n g o f D W C / RC C p i p e s . During excavation o f t r e n c h , i t h a s t o be ensured that the excavated soil does not mix with the ballast available. The depth o f 1 m trench shall b e fro m the bottom o f sleepers for track crossings. Laying o f cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 750.00 | 385.45 | 2,89,087.5 |
| 66 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by r a m m i n g and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 108.00 | 501.03 | 54,111.24 |
| 67 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 750.00 | 208.54 | 1,56,405 |
| 68 | Construction of Support for the GI pipes laid in RCC Box type bridges | Numbers | 72.00 | 367.41 | 26,453.52 |
| 69 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at b o t h e n d s d u l y supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e closed with brick masonry abutments work so that no cable is exposed, The work shall be carried o u t a s p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required for the w o r k s h a l l be supplied by the Contractor]. | Metre | 540.00 | 182.87 | 98,749.8 |
| 70 | L a y i n g o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included i n this schedule). | Metre 135000.00 | — | 18.18 | 24,54,300 |
| 71 | Placing of one row of country bricks of size approximately 220mm x 100mm x 60mm breadth wise horizontally above the cables in 0.3m width trench. [Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 1000.00 | 62.99 | 62,990 |
| 72 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, a n d consolidating the trench by ramming and levelling." | Metre | 900.00 | 15.4 | 13,860 |
| 73 | "Refilling of cable trench 0.5m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling." | Metre | 100.00 | 7.77 | 777 |
| 74 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g of concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation a n d refilling t h e p i t and consolidating i t b y ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions a n d also at every track/road crossing." | Numbers | 300.00 | 123.35 | 37,005 |
| 75 | Excavation o f cable coil pit t o a size of 1.5mx1.5m and depth a s instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ A F TC huts, apparatus cases e t c . The work includes coiling t h e underground cables and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 15.00 | 949.05 | 14,235.75 |
| 76 | "Road crossing/ Track Crossing through Horizontal Drilling at approximately depth of 1.5 to 2m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables e t c . (Note: T h e pilot used for HDD should be of sufficient size to suit insertion of HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination a s directed b y t h e site engineer) ( Supply o f HDPE pipe i s not covered in this schedule)" | Metre | 804.00 | 1,351.45 | 10,86,565.8 |
| 77 | Cutting/Breaking o f R C C platform or concrete to a width of 0.5mtrs 0.3 mtrs using cutter machine without damaging the platform. A n d p l a s t e r i n g the removed slabs after laying o f cables with proper finishing. (required material should be supplied by the contractor). | Metre | 300.00 | 3,764.41 | 11,29,323 |
| 78 | Blowing/Drawing o f O F C cable/Power c a b l e / S i g n a l l i n g c a b l e inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duc t integrity test for solid lubricated H D P E pipe. ( This includes Tr a n s p o r t a t i o n o f m a t e r i a l s from nominated stores to site) | Metre | 6000.00 | 23.43 | 1,40,580 |
| 79 | Supply of Main LED Signal Aspect - Green as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 15.00 | 10,030 | 1,50,450 |
| 80 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 26.00 | 8,850 | 2,30,100 |
| 81 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 21.00 | 9,233.5 | 1,93,903.5 |
| 82 | Supply o f subsidiary S i g n a l A s p e c t - Route LED a s p e r RDSO Specifications S P E C I F I C A T I O N NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 25.00 | 5,703.33 | 1,42,583.25 |
| 83 | Supply of subsidiary Signal Aspect - Calling on L E D a s p e r RDSO Specifications SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 11.00 | 5,726.13 | 62,987.43 |
| 84 | Supply o f subsidiary S i g n a l A s p e c t - Shunt LED a s p e r R D S O Specification S P E C I F I C A T I O N NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 42.00 | 5,740.7 | 2,41,109.4 |
| 85 | S u p p l y a n d p r o v is io n o f Screening arrangement for Signals i n R E area as per standard p r a c t i c e . T h e work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 S W G G I w i r e s f r o m the screening arrangement up to surface base as per t h e instructions o f Railway representative at site.[All materials required for this work shall be supplied by the Contractor]. | Numbers | 2.00 | 1,880.71 | 3,761.42 |
| 86 | S u p p l y o f C o l o u r l i g h t S i g n a l pole 140mm dia, 4 . 6 m / 3 . 6 m t a l l with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of colour light Signal pole 4 . 6 m tall and 140 mm dia(Galvanised) | Numbers | 9.00 | 5,841 | 52,569 |
| 87 | S u p p l y o f C o l o u r l i g h t S i g n a l pole 140mm dia, 4 . 6 m / 3 . 6 m t a l l with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply of colour light Signal pole 3 . 6 m tall and 140 mm dia (Galvanised) | Numbers | 10.00 | 4,737.7 | 47,377 |
| 88 | Supply of surface base to suit CLS Signal p o l e 1 4 0 m m d i a w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 19.00 | 6,814.5 | 1,29,475.5 |
| 89 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary i n s p e c t i o n a s per specification/ drawing/ description enclosed i n this document. a)Supply of l a d d e r w i t h p l a t f o r m ( 4 . 6 m ) for CLS(Galvanised) | Numbers | 9.00 | 5,698 | 51,282 |
| 90 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary i n s p e c t i o n a s per specification/ drawing/ description enclosed i n this document. b)Supply of l a d d e r w i t h p l a t f o r m ( 3 . 6 m ) for CLS(Galvanised) | Numbers | 10.00 | 5,494.5 | 54,945 |
| 91 | Supply of post type shunt signal - complete with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 7.00 | 5,087.5 | 35,612.5 |
| 92 | Supply o f Ground type shunt signal - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 8.00 | 7,463.5 | 59,708 |
| 93 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply o f colour light Signal unit (4 aspect) | Numbers | 3.00 | 19,470 | 58,410 |
| 94 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect) | Numbers | 8.00 | 16,874 | 1,34,992 |
| 95 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 9.00 | 14,278 | 1,28,502 |
| 96 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Junction type route indicator - 2 way | Numbers | 1.00 | 18,691.2 | 18,691.2 |
| 97 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of Junction type route indicator - 3 way | Numbers | 1.00 | 22,260.7 | 22,260.7 |
| 98 | Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal | Numbers | 9.00 | 3,663 | 32,967 |
| 99 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large | Numbers | 4.00 | 3,569.5 | 14,278 |
| 100 | Supply C-marker/A-marker Name Plate | Numbers | 9.00 | 253.91 | 2,285.19 |
| 101 | Supply of Signal post telephone with facility of paging and talk-back including voice communication equipment with suitable switching arrangement a t the Signal post and a t SM 's r o o m a s per specification enclosed in this document. This includes drawl of tail cable through GI pipe 25mm dia and 2 mtrs long duly clamped to Signal post w i t h b e n d as required at site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. The wiring shall be done using wire PVC 16/0.2mm copper. [Talk-back equipment complete including housing box, wire PVC 16/0.20mm and all other miscellaneous materials required for the w o r k s h a l l b e s u p p l i e d b y the Contractor]. | Numbers | 2.00 | 11,897.35 | 23,794.7 |
| 102 | S u p p l y o f p l u g - i n t y p e , S t y l e QL1, Magnetically Latched Neutral Line 24V DC, 11F/4B contacts Re l a y complete w i t h plug board (base plate), connectors and retaining clips and conforming to BRS 935A and RDSO Spn. N o I R S S 3 4 a n d S - 2 3 o r latest. The interlocking code f o r this unit shall be "ABDEG" | Numbers | 25.00 | 7,076.52 | 1,76,913 |
| 103 | Supply of Relay, AC Immune, plug-in- type, Style 'QNA1K', DC Neutral line, 24V, 1000 ohms 6F.6B, contacts, front contacts metal to carbon and back contacts metal to carbon, complete with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S60, IRS:S 34, IRS:S 23 & RDSO Spec.No. STS/ E/Relays/UEA (PI) dt.30.05.97 (Annexure-II) (as applicable). The interlocking code for this unit shall be CDEKY. | Numbers | 20.00 | 5,890.8 | 1,17,816 |
| 104 | Supply of Plug in Type Q-Series Relay QBAT (2F/2B)(Miniature, Tractive armature, AC Immune, D.C Biased Track Relay) A.C. immunity level o f 8 0 Volt A.C, coil nominal resistance o f 9 Ohms, confirming t o BRS spec n o . 9 3 9 A & 966F2 and RDSO specification No. 8 4 / 8 8 o r latest. The interlocking code for this unit shall be "ABEJX" | Numbers | 4.00 | 9,858.79 | 39,435.16 |
| 105 | Supply of Relay, Non-AC Immune, plug- in type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. | Numbers | 250.00 | 4,366.63 | 10,91,657.5 |
| 106 | Supply of Relay, AC Immune, plug-in- type, Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH. | Numbers | 200.00 | 4,639.03 | 9,27,806 |
| 107 | Supply of electronic time delay units (120/60 secs) w i t h p l u g boards, connectors and retaining c l i p s with n e c e s s a r y i n s p e c t i o n as per s p e c i fi c a t i o n / d r a w i n g / description enclosed in this document. | Numbers | 5.00 | 2,742.03 | 13,710.15 |
| 108 | Supply of lamp proving relays(QECX-61) for a)LED aspects w i t h p l u g boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers | 86.00 | 5,901.5 | 5,07,529 |
| 109 | Supply of QBCA1 - heavy duty contact relays with necessary inspection a s per specification/ | Numbers | 37.00 | 6,613.75 | 2,44,708.75 |
| 110 | Manufacture a n d supply o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F5, wiring and termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 16.00 | 4,945.51 | 79,128.16 |
| 111 | Manufacture a n d supply o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F5, wiring and termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ LC control circuit (up to 8 relays/plug in type) | Set | 10.00 | 8,786.26 | 87,862.6 |
| 112 | Manufacture a n d supply o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F5, wiring and termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ LC control circuit (up to 12 relays/plug in type) | Set | 2.00 | 11,355.02 | 22,710.04 |
| 113 | Supply of QTA2 - track relays with plug boards, connectors a n d retaining clips with necessary inspection as per specification | Numbers | 36.00 | 4,070 | 1,46,520 |
| 114 | Supply o f QSPA1 type relays with plug boards, connectors a n d retaining clips with necessary i n s p e c t i o n a s per specification/drawing/ | Numbers | 40.00 | 7,139 | 2,85,560 |
| 115 | Supply o f powder coated FTOT o f 500 capacity | Numbers | 7.00 | 50,593.8 | 3,54,156.6 |
| 116 | Concreting and e r e c t i o n o f cable termination rack 500/210/140 Terminals capacity on teakwood base frame of size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting as p e r standard practice.(Supply o f cable termination racks a r e not included in this schedule).[Foundation b o l t s and nuts with washers, cement, sand, stone j e l l y , t e a k w o o d base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Concreting and erection of cable termination rack -500 terminal capacity | Numbers | 7.00 | 13,668.26 | 95,677.82 |
| 117 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e clamps and base planks, termination o f cables, provision of ND type fuses o f required capacities, provision o f copper b u s bar for supply terminals, wiring, provision of termination particulars diagram board u s i n g plywood of thickness 1 2 m m - teakwood fi n i s h o f size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with p h y n o l i c s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly. (Supply of PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts a n d w a s h e r s , f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s b a r s , teakwood 5 0 m m x 50mm for c a b l e clamps, 2 5 m m x 1 0 0 m m f o r base planks, p h y n o l i c s h e e t 6 m m t h i c k o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3 m m thick, paint a n d a l l other m i s c e l l a n e o u s materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 3100.00 | 167.99 | 5,20,769 |
| 118 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e clamps and base planks, termination o f cables, provision of ND type fuses o f required capacities, provision o f copper b u s bar for supply terminals, wiring, provision of termination particulars diagram board u s i n g plywood of thickness 1 2 m m - teakwood fi n i s h o f size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with p h y n o l i c s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly. (Supply of PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts a n d w a s h e r s , f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s b a r s , teakwood 5 0 m m x 50mm for c a b l e clamps, 2 5 m m x 1 0 0 m m f o r base planks, p h y n o l i c s h e e t 6 m m t h i c k o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3 m m thick, paint a n d a l l other m i s c e l l a n e o u s materials shall be supplied by the Contractor]. b)Termination using P B T fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 150.00 | 201.27 | 30,190.5 |
| 119 | Carrying out alterations t o t h e existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm c o p p e r. T h e w o r k includes painting alterations and releasing the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r t h e w ork shall b e supplied by the Contractor]. | Per Relay | 30.00 | 695.67 | 20,870.1 |
| 120 | S u p p l y o f a s p i r a t i o n t y p e smoke detector. Highly sensitive smoke aspiration system for Monitoring of r o o m s a n d equipment's for earliest possible fire detection For Relay rooms a s p e r R D S O spec No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 3.00 | 7,08,081.12 | 21,24,243.36 |
| 121 | S u p p l y o f s i n g l e L o o p Analog addressable Fire A l a r m s y s t e m with loo p capacity of connecting maximum 50 devices. The panel shall have a built i n power supply and battery charger R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 3.00 | 3,11,682.08 | 9,35,046.24 |
| 122 | Supply of Multi Sensor detector Dual Optical/ Thermal a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 60.00 | 16,042.23 | 9,62,533.8 |
| 123 | S u p p l y o f Addressable S i n g l e action indoor manual call point with back box (RED) as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 4.00 | 9,494.38 | 37,977.52 |
| 124 | Supply of Sounder having range of 81 dbA to 92 d b A a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 4.00 | 11,420.51 | 45,682.04 |
| 125 | S u p p l y o f I n t e l l i g e n t addressable Monitor module a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 11.00 | 9,494.38 | 1,04,438.18 |
| 126 | Supply of Intelligent addressable control m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 11.00 | 9,494.38 | 1,04,438.18 |
| 127 | Supply o f Auto-dialer f o r S M S alarm generation & routing in case of Fire Alarm to concerned perso ns a s per RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 3.00 | 43,931.48 | 1,31,794.44 |
| 128 | Supply of 2core 1.5sq.mm FRLS Copper unarmoured cable a s per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 500.00 | 296.94 | 1,48,470 |
| 129 | S u p p l y o f L H S C a b l e R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 200.00 | 2,246.07 | 4,49,214 |
| 130 | Supply of L H S control module. RDSO Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 3.00 | 1,55,660.6 | 4,66,981.8 |
| 131 | Supply and Installation of Air sampling CPVC Pipes with all required accessories for Aspiration system) | Set | 3.00 | 76,137.76 | 2,28,413.28 |
| 132 | Supply of BIS listed semi-automatic stainless steel fire extinguisher with UL approved clean gas with auto manual reverse stainless steel valve 'NASA 200 MAR' or similar having capacity of 2kg, and made of stainless steel 304 grade w ith Indian Railway logo p u t on each unit. | Per Unit | 12.00 | 24,780 | 2,97,360 |
| 133 | Supply o f Relay Module a s p e r RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 3.00 | 9,867.99 | 29,603.97 |
| 134 | Supply of TCIP Module /Networking card for interfacing t h e F i r e A l a r m and Detection systems | Numbers | 3.00 | 30,881.44 | 92,644.32 |
| 135 | Installation, testing a n d commissioning charges o f fi r e alarm system including programming of devices and fire alarm panel | Set | 3.00 | 95,933.57 | 2,87,800.71 |
| 136 | Supervision, programming,testing & Commissioning o f Aspiration smoke detection | Set | 3.00 | 83,751.53 | 2,51,254.59 |
| 137 | Supply of Block Bell equipment to be used in conjunction w i t h block instrument i n 25KV 50Hz AC electrified area as per specification No IRS:TC- 44/88 A m d 1 i n c l u d i n g latest amendments. | Numbers | 2.00 | 2,406.36 | 4,812.72 |
| 138 | S u p p l y o f B l o c k Fi l t e r U n i t u s e d in conjunction w i t h b l o c k instrument in 25KV, 50Hz AC traction area as per specification No IRS:S-68/89 including latest amendment | Numbers | 2.00 | 18,161.86 | 36,323.72 |
| 139 | Supply o f Thermal Imager Pocket, with accessories as per Technical specification | Numbers | 1.00 | 1,06,188.2 | 1,06,188.2 |
| 140 | S u p p l y o f Coating Thickness Gauge, with accessories, as per Technical specification | Numbers | 1.00 | 29,500 | 29,500 |
| 141 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 1290.00 | 1,119.16 | 14,43,716.4 |
| 142 | S u p p l y o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 M e t e r s a s per specification N o . I S 4984: 2016 with l a t e s t a m e n d m e n t s a n d Material Grade:PE 80 | Metre | 804.00 | 853.55 | 6,86,254.2 |
| 143 | Supply and laying of PVC Warning Tape colour Orange, width of 250mm (10") by p r i n t i n g w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 1000.00 | 46.15 | 46,150 |
| 144 | Supply of Electronic Cable Route Marker 3M make or similar, Model: RFID (1421) and installation, c a b l e d e t e c t io n of capacity to detect the cable upto 5 feet depth. | Numbers | 350.00 | 2,441.72 | 8,54,602 |
| 145 | S u p p l y o f H D P E P i p e 4 0 m m (outer dia)/33 mm (inner dia) with couplers | Metre | 6000.00 | 60.93 | 3,65,580 |
| 146 | S u p p l y a n d Installation o f Wall/Rack m o u n t a b l e 2 4 F i b r e management system (FMS) c o n f o r m i n g to RDSO/SPN/TC- 37/2000(rev-3 amdt-1 or latest similar to COMMSCOPE m ak e or better, suitable for splicing and front patching 24F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required length ( A l l other materials required for splicing are to be supplied by contractor ) | Numbers | 10.00 | 18,686.74 | 1,86,867.4 |
| 147 | Supply a n d Installation o f surface Wall mountable type 1 9 i n c h 1 2 U network Rack with front glass door with lock and rack fixing multipoint AC Power trip & all accessories (Power extension board with one set of MCB, exhaust fan, cable manager) | Numbers | 4.00 | 6,761.51 | 27,046.04 |
| 148 | Supply and Installation of covered 19inch Racks of size 1950mm x600mm x 600mm or higher (Make: HCL/ Vero/President/ Rittal/ Puncom or better) complete with all fittings including DC Fans (24V/48V)-2nos, separator sheet/ plate to keep testing equipment-1no and AC power distribution panel ( Horizontal fitting) with power sockets and fuse protection ( min 6 nos of 230V - 15/5A combined and other accessories | Numbers | 2.00 | 65,734.12 | 1,31,468.24 |
| 149 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. | Numbers | 190.00 | 1,622.5 | 3,08,275 |
| 150 | Supply of Track Feed Resistance | Numbers | 40.00 | 287.77 | 11,510.8 |
| 151 | Supply o f P B T terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 6100.00 | 61.44 | 3,74,784 |
| 152 | Supply o f P B T terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 4400.00 | 93.02 | 4,09,288 |
| 153 | Supply o f P B T terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 600.00 | 103.84 | 62,304 |
| 154 | Supply of E-Type Locks | Numbers | 8.00 | 1,234.88 | 9,879.04 |
| 155 | S u p p l y o f 4 w i r e D T M F b a s e d way station equipment complete a s per RDSO specification No.IRS.TC@45<47@93 a n d 4 wire control telephone with audio visual indication and r e s e t button fi t t e d on telephone conforming to specification No.IRS-TC@45&47@97 or latest. | Set | 2.00 | 9,086 | 18,172 |
| 156 | Manufacture and supply of teak wood tool box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No. Rish Multi 18S with suitable carrying case and test probes. b. Centre zero ammeter 30-0-30 Amps - 1 No. c. Screw drivers of different types and sizes with common handle - 1 set d. Spanner double ended 33mm - 1 No. e. Spanners double ended 3/8x1/2" - 1 No. f. Spanners double ended 5/8x3/4" - 1 No. g . Spanners double ended 7/8x1" - 1 No. h. Hammer 1 1/2 lbs ball pane - 1 No. i. Hacksaw frame - 1 No. j. Adjustable screw spanner 12" - 1 No. k. Insulated cutting pliers- 1 No. l. Insulated nose plier- 1 No. m. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. n. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. o . Megger 500V/ 500Mohms. with Probe- 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site.[Teak w oo d tool b o x made o f 2 5 m m teak wood plank, perspex sheet, all t h e tools mentioned above, padlock and other miscellaneous items shall be supplied by the Contractor]. | Set | 1.00 | 29,185.6 | 29,185.6 |
| 157 | S u p p l y a n d installation o f teakwood glass fronted b o x o f s i z e 3 0 0 m m x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall b e supplied b y the Contractor]. | Numbers | 4.00 | 7,505.45 | 30,021.8 |
| 158 | Installation of combined type point machine-IRS t y p e a n d connecting all ground connections including wiring and termination in point machine and interconnections between point machine and CT box through PVC hose p i p e w i t h 3/0.75mm and 7/1.40mm copper w i r e a n d painting. This work i n c l u d e s p r o v i s i o n o f insulatio n to stretcher bars, throw b a r l u g a n d "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for t h e w o r k s h a l l b e supplied by the Contractor]. | Numbers | 20.00 | 16,383.88 | 3,27,677.6 |
| 159 | Painting o f existing colour light Signals as per standard practice. T h e work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium/ enamel paint on the Signals - complete as instructed by Railway representative at site.[Aluminium paint, red-oxide a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 6.00 | 2,442 | 14,652 |
| 160 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation b o l t s , c e m e n t , M sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 19.00 | 9,213.28 | 1,75,052.32 |
| 161 | "Erection o f surface base, signal pole, mounting o f colour light signal u p t o 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament s w i t c h i n g u n i t s , C L S transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing o f number plates, m a r k e r b o a r d , l e n s g u a r d , fi x i n g of speed limit board wherever necessary, termination o f t a i l cable s, w i r i n g of signal unit w i t h P V C w i r e 3/0.75mm copper, provision of EWS locks, and painting of one coat o f r e d oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole t o prevent the offset bracket from sliding down. (Supply of surface base, Offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, M sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens- guard, all fixing bolts and nuts, lead w o o l , p a i n t s P V C / N y l o n sleeves, enameled n u m b e r p l a t e s . enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 19.00 | 8,287.08 | 1,57,454.52 |
| 162 | "Excavation of pit and casting concrete foundation a s per Drg, No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 8.00 | 4,645.17 | 37,161.36 |
| 163 | "Erection o f Ground type shunt signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing o f lens guards, n u m b e r plate, termination o f tail cables, w i r i n g of signal u n i t w i t h P V C wire 3/0.75mm copper, provision o f E W S locks and painting o f o n e coat o f r e d oxide and two coats o f Aluminium/ enamel paint. (Supply o f Ground t y p e s h u n t signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n this schedule). [ W i r e PVC 3/0.75mm c o p p e r , lens guards, E W S locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." | Numbers | 8.00 | 3,170.44 | 25,363.52 |
| 164 | Fixing of Offset brackets using 'U' bolts and nuts, erection o f Post type shunt Signals, termination o f tail cables and w i r i n g using wire P V C 3/0.75mm c o p p e r , provision of EWS l o c k and painting o f o n e coat o f red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n t h e C L S p o s t and provision o f a through bolt with nut to prevent the Off-setbracket from slipping down." | Numbers | 7.00 | 2,306.03 | 16,142.21 |
| 165 | Fixing of junction type route indicators - 1 way t o 6 ways - complete/ fixing of additional l i m b t o t h e existing route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply of junction t y p e R o u t e Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e m e s h , PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].b)Fixing a n d w i r i n g of direction type route indicator - 2 way | Numbers | 1.00 | 2,460.04 | 2,460.04 |
| 166 | Fixing of junction type route indicators - 1 way t o 6 ways - complete/ fixing of additional l i m b t o t h e existing route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply of junction t y p e R o u t e Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e m e s h , PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].c)Fixing a n d w i r i n g of direction type route indicator - 3 way | Numbers | 1.00 | 2,679.26 | 2,679.26 |
| 167 | Fixing of Offset brackets using 'U' bolts and nuts, erection of Calling On Signals/ 'A' marker lights, termination of tail cables and wiring u s i n g w i r e PVC 3/0.75mm copper, provision o f EWS lock, number plates/ marker boards and painting. The work also includes drilling suitable h o l e s o n t h e CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.(Supply o f C a l l i n g on S i g n a l / ' A ' marker light, LED aspects/holders & b u l b s a n d Off set brackets is not covered in this schedule).['U' bolts a n d nuts, through b o l t s w i t h nut, wire P V C 3/0.75mm copper, E W S lock, Enameled number plates, w ire mesh, PVC/Nylon sleeves, p a i n t s a n d a l l other miscellaneous materials shall be supplied by the contractor]. | Numbers | 9.00 | 2,081.25 | 18,731.25 |
| 168 | Releasing o f existing t a i l c a b l e s and drawl of new tail cables for colour light signals up to f o u r aspec ts w i t h or without route indicator, post type shunt signal and Calling on signals, termination o f n e w t a i l cables and w i r i n g u s i n g w i r e P V C 3/0.75mm copper. This work includes drawl of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals and re-surfacing t h e earth excavated as instructed by Railway representative at site. [Wire PVC 3/0.75mm copper, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Per Unit | 4.00 | 1,524.86 | 6,099.44 |
| 169 | Excavation o f p i t a n d construction of masonry platform a s p e r drawing No. SG/CN/02/12 with country bricks o f size 220mmx 100mmx60mm (app) a t the foot of signal post telephones as per the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm (app), cement, M sand a n d a l l o t h e r miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 2.00 | 5,355.94 | 10,711.88 |
| 170 | Painting of existing boards like LEGEND boards, warning boards, S T O P boards etc., as per standard practice and as per the instructions of Railway representative at site.(Supply of boards i s n o t included i n this schedule).[Paint and all other miscellaneous materials required for the work shall b e supplied by the Contractor]. | Numbers | 2.00 | 1,262.63 | 2,525.26 |
| 171 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 18.00 | 8,914.5 | 1,60,461 |
| 172 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers | 18.00 | 7,145.44 | 1,28,617.92 |
| 173 | Alteration t o existing D C Track Circuits to suit R E / N o n R E standard a s per approved signaling p l a n . T h i s work includes provision of d o u b l e bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 2.00 | 4,234.65 | 8,469.3 |
| 174 | Alteration t o existing D C Track Circuits to suit R E / N o n R E standard a s per approved signaling p l a n . T h i s work includes provision of d o u b l e bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers | 2.00 | 3,850.31 | 7,700.62 |
| 175 | Excavation o f p i t , c a s t i n g concrete foundation a n d erection o f apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door a n d another for the back door, fixing o f one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule). [Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 70.00 | 11,333.1 | 7,93,317 |
| 176 | "Excavation o f pit, casting concrete foundation a n d erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock f o r t h e f r o n t d o o r and latching arrangement for the back door, and fi x i n g o f o n e hardwood s h e l f plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for t h e w o r k s h a l l b e supplied by the Contractor]""" | Numbers | 10.00 | 8,787.04 | 87,870.4 |
| 177 | Excavation o f p i t , erection o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia a n d 300mm l o n g a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e f o r c a b l e throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes i n s i d e and outside with one coat of red-oxide and t w o coats o f aluminium paints.(Supply o f C T b o x e s i s n o t covered i n this schedule. Rails o f different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.)[Cement, M sand, stone jelly o f size 20/25mm, p a i n t , varnish, GI P i p e s 32mm dia with clamp nuts - 12mm thick - 2 Nos. for e a c h pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 4.00 | 4,999.16 | 19,996.64 |
| 178 | Excavation of pit in and around the existing location boxes v e r y carefully without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement as instructed b y t h e Railway representative a t s i t e . T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils t o give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location b o x e s t o the required level shall be done as instructed by the Railway representative a t s i t e . I f the e x i s t i n g e a r t h connections t o the location boxes are disturbed, the earth wires shall be properly re-connected. a) Shifting of apparatus case (full) | Numbers | 6.00 | 5,348.81 | 32,092.86 |
| 179 | Excavation of pit in and around the existing location boxes v e r y carefully without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement as instructed b y t h e Railway representative a t s i t e . T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils t o give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location b o x e s t o the required level shall be done as instructed by the Railway representative a t s i t e . I f the e x i s t i n g e a r t h connections t o the location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half) | Numbers | 2.00 | 3,545.06 | 7,090.12 |
| 180 | Termination o f new main/tail cables on the existing terminals/ fuse blocks in apparatus cases/ batte ry b o x e s / CT boxes/ cable termination racks a s per approved circuit diagram. The terminal p a r t i c u l a r s a r e to be repainted /corrected o n t h e doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w o r k includes closing the opening created for entry of new cables i n the apparatus cases w i t h masonry brick work and sealing the bottom of the apparatus cases/ c a b l e termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials s h a l l be supplied b y the contractor].(Per Unit = Per Terminal block) | Per Unit | 600.00 | 73.59 | 44,154 |
| 181 | Termination of main, tail, Signaling and p o w e r cables a n d internal w i r i n g on terminal/ fuse blocks i n n e w apparatus cases, cable termination boxes a n d in gate Lodges e x c l u d i n g cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagra m a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and the bottom surface shall b e sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n t h i s schedule)." a ) Te r m i n a t i o n o n 2 5 / 6 0 m m PBT terminals (new location)(Phynolic sheet) (Per Unit = Per Terminal block) | Per Unit | 7280.00 | 172.14 | 12,53,179.2 |
| 182 | Termination of main, tail, Signaling and p o w e r cables a n d internal w i r i n g on terminal/ fuse blocks i n n e w apparatus cases, cable termination boxes a n d in gate Lodges e x c l u d i n g cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagra m a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and the bottom surface shall b e sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n t h i s schedule)." b)Termination o n P B T fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 440.00 | 209.93 | 92,369.2 |
| 183 | Termination of main, tail, Signaling and p o w e r cables a n d internal w i r i n g by fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, t e r m i n a t i o n of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagra m a n d cable plan, painting o f particulars o n sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and the bottom surface shall b e sealed w ith sealing compound. a)Termination o f cables o n 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 120.00 | 151.09 | 18,130.8 |
| 184 | Termination of main, tail, Signaling and p o w e r cables a n d internal w i r i n g by fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, t e r m i n a t i o n of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagra m a n d cable plan, painting o f particulars o n sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and the bottom surface shall b e sealed w ith sealing compound. b)Termination o f cables o n P B T f u s e block (existing location)(Per Unit = Per Fuse block) | Per Unit | 10.00 | 188.86 | 1,888.6 |
| 185 | "Painting of existing apparatus case (Outside) - Full size" | Numbers | 6.00 | 1,182.15 | 7,092.9 |
| 186 | "Painting of existing apparatus case (Outside) - Half size" | Numbers | 2.00 | 1,132.2 | 2,264.4 |
| 187 | Charging a n d installation o f secondary cells of t h e following capacities, on existing battery stand/ RCC slabs in the battery room. T h e w o r k involves charging of secondary cells, fixing and connecting the batteries with strips, manufacture and fixing of teakwood terminal b o x , termination of cables, wiring with suitable wire PVC 7/1.40mm and 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision o f battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n t h e relay room. T h e particulars shall b e digitally u s i n g good quality "laminated gum sheet, provision of hydrometer -1 No. on a s t a n d a n d battery tester-1 No. Charging o f secondary cells shall be done by the contractor through reputed agencies.(Supply of secondary cells is not covered in this schedule). [ Te a k w o o d p l a n k 2 5 m m t h i c k for manufacturing termination b o x with locking facility, wire P V C 7/1.4mm and 3/0.75mm copper, anti-corrosive paint, varnish, PVC pipes/ casing, and all other miscellaneous materials required for t h i s w o r k s h a l l be supplied by the contractor]." b)Installation o f 2V-200AH cell o n existing stand/ slabs(Per Unit = Per Cell) | Per Unit | 60.00 | 869.41 | 52,164.6 |
| 188 | Installation of DTMF equipment | Set | 2.00 | 5,339.1 | 10,678.2 |
| 189 | Installation o f d o u b l e l i n e S G E type block instruments on the block counter. The work involves termination of cables o n t h e test panel a n d block counter, block wiring, interconnection between t e s t panels and block instrument by u n d e r g r o u n d signaling cable and painting the instrument as per the instructions of Railway representative at site.(Supply of block instruments, block counters and underground cables i s n o t c o v e r e d in this schedule). [Phynolic sheet for fixing terminals, wire P V C 1 6 / 0 . 2 m m c o p p e r , 3/0.75mm, paint, and a l l o t h e r miscellaneous materials required for the work shall be supplied by the contractor]. | Numbers | 2.00 | 11,238.75 | 22,477.5 |
| 190 | Fixing o f Annunciator a t SM's Room as required by Railways, wiring it as per circuit diagram a n d p a i n t i n g of p a r t i c u l a r s . The work includes connecting 1 No. of magneto telephone with Ni-cad power pack 4V-2.2AH with c h a r g e r t o w o r k o n 1 1 0 V A C and connecting t h e annunciator t o the different telephone c i r c u i t s . The particulars o f the circuits a n d the ringing codes shall be painted on the top of the annunciator box.(Supply of annunciator is not included in this schedule)."[Magneto telephone handle type with Nicad power pac k 4V-2.2AH with charger t o work on 110VAC, wire P V C 16/0.2mm copper, paint a n d all other miscellaneous materials required f o r t h e w ork shall b e supplied by the Contractor]." | Numbers | 2.00 | 4,094.05 | 8,188.1 |
| 191 | Installation of magneto telephones with Nicad pack | Numbers | 21.00 | 3,322.6 | 69,774.6 |
| 192 | Casting concrete foundation of size 900mmX 900mmX900mm for pedestal, 400mmX400mmX 600mm for meeting post, fixing of lifting barrier boom, contact makers, termination of cables, wiring and painting as per the instructions of Railway representative at site. (Supply of pedestals, meeting posts, contact maker, electric lifting barriers, rail posts, cranks and 'A' type foundation is not covered in this schedule). [Concreting materials, bolts and nuts, wire PVC 3/0.75mm copper and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Unit | 2.00 | 20,297.74 | 40,595.48 |
| 193 | Fi x i n g a n d w i r i n g o f T w o N o s . of Electronic Gate Warning equipment for each level crossing gate, o n e o n each r o a d warning signal, amplifier i n the apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting. (Electronic G a t e Wa r n i n g Equipment and amplifier will be supplied by Railways).[All wiring, fixing and painting materials shall be supplied by Contractor]. | Set | 1.00 | 4,491.34 | 4,491.34 |
| 194 | Installation o f hand plunger l o c k with [single/double] on gauge tie plate for locally operated point/ on suitable fixing arrangements for LC gate winch interlocking, connecting t h e sam e and adjusting them. The w o r k includes c u t t i n g s u i t a b l e notches on split stretcher bars, provision of suitable MS cover of 3mm thick for the hand plunger lock, provision o f point/trap indicator and painting. Supply o f hand plunger locks and point/ trap indicator is n o t covered i n this schedule).[Un-cut s p l i t s t r e t c h e r b a r s f o r H P Lock Single/Double, M S c o v e r 3 m m thick, coal bengal, fixing bolts and nuts with washers, paint and all other miscellaneous materials required for t h e w o r k s h a l l b e supplied by the contractor]. a ) Installation o f hand plunger lock (Single/double) | Numbers | 4.00 | 12,034.25 | 48,137 |
| 195 | Fixing of point/ trap indicator | Numbers | 4.00 | 2,160.34 | 8,641.36 |
| 196 | F i x i n g o f e l e c t r i c a l d e t e c t o r s on extended gauge t i e p l a t e , providing insulations, connecting ground connections, w i r i n g with wire PVC 3/0.75mm copper, connecting the detector and TLD box through a hose pipe, drawl of jumper wires from the detector to TLD b o x a n d painting. (Supply of Electrical detectors complete, switch extension pieces, ground connections,extended gauge tie plate, TLD boxes with stumps is not covered i n this schedule). [Wire PVC 3/0.75mm copper, PVC hose pipe, all fixing bolts and nuts, all types of insulations, paint and all other miscellaneous materials required for this work shall be supplied by the contractor]. | Numbers | 4.00 | 6,181.31 | 24,725.24 |
| 197 | Provision of E type lock with key for fixing the same in LC/HP/FP Locks/SM slides | Numbers | 8.00 | 697.45 | 5,579.6 |
| 198 | Provision of HDPE Pipe of dia 40/33 mm | Metre | 6000.00 | 26.11 | 1,56,660 |
| 199 | Laying of DWC/Split DWC Pipes for Track Crossing/Road Cutting/Trenches | Metre | 1900.00 | 42.46 | 80,674 |
| 200 | "Releasing of existing relay racks/ cable termination r a c k s a l o n g w i t h a l l the terminals, fuse b l o c k s , r e l a y s , with jacks, holding clips etc., 50 way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative a t site. After releasing, t h e floor shall b e levelled and cement plastered" | Rack | 6.00 | 1,977.19 | 11,863.14 |
| 201 | Releasing of existing Route Indicators of different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 2.00 | 1,541.51 | 3,083.02 |
| 202 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly a t a p l a c e as instructed by Railway representative at site. Also the resultant pits shall b e re- surfaced and consolidating by ramming and levelling" | Numbers | 3.00 | 1,580.36 | 4,741.08 |
| 203 | Releasing o f existing point lay-out with facing point lock,split stretchers, electrical detector, lock bars, point/trap indicators cranks, r o d s e t c . , carefully w i t h o u t D a m a g i n g the materials, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Set | 2.00 | 2,852.7 | 5,705.4 |
| 204 | Removal o f obstructing sleepers, and rails available in the path of cable trench (Above the ground) | Numbers | 40.00 | 235.47 | 9,418.8 |
| 205 | Removal o f obstructing sleepers, and rails available in the path of cable trench (buried inside ground) | Numbers | 20.00 | 3,205.7 | 64,114 |
| 206 | Jungle cutting along with the cable route | Metre | 250.00 | 5.84 | 1,460 |
| 207 | Releasing of hand plunger lock s i n g l e / d o u b l e along with switch extension pieces, stretcher bars, point/ trap indicators and o t h e r fixtures c a r e f u l l y without damaging the m ateria ls, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Set | 2.00 | 2,389.28 | 4,778.56 |
| 208 | Releasing o f existing apparatus cases (Full/ Half/ Q u a r t e r s i z e ) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f a l l t y p e s EKTs, Secondary Cells, power equipments, 'E' t y p e l o c k s , e t c . , and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. T h e r e l e a s e d m a t e r i a l s s h a l l be accounted and stacked a t a place as instructed by Railway representative at site. | Numbers | 60.00 | 3,006.71 | 1,80,402.6 |
| 209 | Breaking o f concrete and releasing the existing cable termination boxes, after releasing t h e b a s e p l a n k , Terminal blocks, Fuse Blocks, Terminal Boards, c u t rails, pipes, e t c . , c l o s i n g the resultant p i t s and consolidating i t by ramming a n d levelling. The released m a t e r i a l s s h a l l b e accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 20.00 | 2,004.94 | 40,098.8 |
| 210 | Releasing of existing SM's control panel including base plank, and other gadgets connected very carefully without causing any damage t o t h e panel, accounting and stacking them neatly at a place as instructed by Railway representative at site. The resultant pit in the flooring shall be removed of all c a b l e b i t s , l e v e l l e d a n d cement plastered | Set | 1.00 | 5,257.24 | 5,257.24 |
| 211 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or w i t h o u t Route Indicators, c a l l i n g on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the c o n c r e t e f o u n d a t i o n , c l o s i n g the resultant p i t and resurfacing it by ramming and levelling. | Numbers | 20.00 | 3,083.03 | 61,660.6 |
| 212 | Dismantling a n d releasing o f existing Point machines ( a l l t y p e s ) including ground connections a n d other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 17.00 | 2,698.69 | 45,877.73 |
| 213 | Dismantling and releasing of ground lever frame along with all connected gadgets like lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling. | Set | 3.00 | 5,550 | 16,650 |
| 214 | Releasing of Secondary cells and battery stands available i n t h e battery room along with connecting strips, wires and terminal boxes carefully without causing any damage to t h e batteries, accounting and stacking them neatly at a p l a c e a s instruc te d by Railway representative a t site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered. | Set | 1.00 | 5,395.99 | 5,395.99 |
| 215 | Releasing of existing Block Instruments (all types), B l o c k counters, batteries, block filter, block bell equipment etc., carefully without a n y damage, accounting and stacking them neatly at a place as instructed by Railway representative at site | Numbers | 2.00 | 1,773.23 | 3,546.46 |
| 216 | Releasing o f point rods with r o d roller t r e s t l e s , c o m p l e t e a s s e m b l y. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits a r e t o be covered with earth and consolidated by ramming and levelling. a)Releasing of trestles 1/2 way | Numbers | 4.00 | 86.3 | 345.2 |
| 217 | Releasing o f point rods with r o d roller t r e s t l e s , c o m p l e t e a s s e m b l y. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits a r e t o be covered with earth and consolidated by ramming and levelling. c)Releasing of point roddings | Metre | 20.00 | 14.71 | 294.2 |
| 218 | Releasing o f point rods with r o d roller t r e s t l e s , c o m p l e t e a s s e m b l y. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits a r e t o be covered with earth and consolidated by ramming and levelling. d) Releasing of A type foundations | Numbers | 4.00 | 632.15 | 2,528.6 |
| 219 | Releasing of all the S & T gadgets at LC gates like SM slide instruments, illuminated diagram b o a r d , block counter, termination box, telephones, emergency key box, etc and concerned wiring, accounting and stacking them neatly at a place as instructed by Railway representative a t s i t e . After releasing any holes on the walls/ floor are to be filled with cement mortar and plastered. | Set | 1.00 | 9,557.1 | 9,557.1 |
| 220 | "Releasing of existing ground type shunt signals along with surface base, signal post etc carefully without any damage, accounting and stacking them neatly at a place a s instruc te d b y Railway representative a t site. T h e w o r k also i n c l u d e s b r e a k i n g a n d r e m o v a l of concrete foundation and refilling o f the resultant pit by ramming and levelling." | Numbers | 4.00 | 2,196.41 | 8,785.64 |
| 221 | Releasing of existing TLD boxes with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 180.00 | 159.29 | 28,672.2 |
| 222 | Releasing of all power equipments including equipment stands, terminal boards, power panel etc., i n t h e power r o o m carefully without c a u s i n g any d a m a g e t o the equipments after disconnecting all the supply wires. The released equipments shall be accounted and stacked at a place as instructed by Railway representative at site. After releasing any holes in the walls/flooring shall b e filled with cement mortar and plastered. | Set | 1.00 | 12,640.13 | 12,640.13 |
| 223 | R e l e a s i n g o f e x i s t i n g control equipments - complete including way station equipments, telephones, power supply f o r w a y station equipment and telephones, a l o n g w i t h all wiring, accounting and stacking them neatly at a p l a c e a s instruc te d b y Railway representative at site. | Set | 1.00 | 6,012.04 | 6,012.04 |
| 224 | Survey o f Cable Route and Preparation of Cable Route Plan | Kilometre | 5.00 | 716.01 | 3,580.05 |
| 225 | Videography of cable Route | Kilometre | 5.00 | 519.85 | 2,599.25 |
| 226 | Protection adjustments and re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S&T portion of the works. The w o r k can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 180.00 | 847.59 | 1,52,566.2 |
| 227 | Protection, adjustment a n d reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Te c h n i c i a n ) etc., for executing additional S & T portion of works. The w o r k c a n i n v o l v e fixing, releasing, dismantling, replacement, painting or alteration of various signallilng assets or p a r t s , termination o f c a b l e s , minor patch work on damages at location box, Plastering, Concreting brick work, wiring alterations, cable jointing e t c a s per instruction of Railway representatives at size. | Man- Days | 90.00 | 1,073.45 | 96,610.5 |
| 228 | Transportation of Signalling materials by road a s per the instructions o f Railway representative a t site. T h e w o r k also includes loading a n d unloading o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 1000.00 | 22.75 | 22,750 |
| 229 | Transportation o f Signalling materials more than 100km | MT-Km | 4800.00 | 13.91 | 66,768 |
| 230 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling a n y infringing structures, clearing and removing debris etc., with all leads and l i f t s e t c . , complete and a s p e r the instruction of Railway representative at site. | Hour | 48.00 | 1,202.5 | 57,720 |
| Schedule total | ₹8,95,82,786.45 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TCRstation-1VolumeIPartI.pdf
ATTACHMENT
TCRstation-2VolumeIPartII.pdf
ATTACHMENT
TCR_station_3_Volume_II_Ch_I_Special_Conditions_of_Contract.pdf 3 Volume II Ch I
ATTACHMENT
TCRstation-4VolumeIICh-IIPVC.pdf
ATTACHMENT
TCR_station_5_Volume_II_Ch_III_compressed.pdf
ATTACHMENT
TCR_station_3_Volume_II_Ch_I_Special_Conditions_of_Contract.pdf
ATTACHMENT
TCR-PNQapprovedSIP.pdf
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
AnnxVclarification14052024.pdf
ATTACHMENT
cablecutpenaltyletter.pdf
ATTACHMENT
Policeverificationletter.pdf
ATTACHMENT
CorrectionSlipsGCC.pdf
ATTACHMENT
TCR_station_6_Volume_II_Ch_IV_Technical_conditions_10_7.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .