Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC Accepting being L1 | |
| 2 | L2₹38.6 L+₹2.4 L (6.69%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹39.9 L+₹3.7 L (10.3%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹44.8 L+₹8.6 L (23.8%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical WLR NOT OK |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
18 Oct 2023, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
SPL REPAIR OF BLDG NO P-1438 (HQ SQN B VEH GARAGE) AND P-926 (MOB STORE) OF ARMD REGT AND ROOF TREATMENT, PLINTH PROTECTION AND FALSE CEILING OF BLDG NO P-50, P-57 AND P-57 A OF COY ASC IN THE AREA OF AGE B/R-II UNDER GE (A) NO.1 JODHPUR.
2023_MES_619579_1
GE/JODH (A) NO 1- OF 2023-24 (9192/E8)
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY NO. 1
₹95,000
Yes
16 Nov 2023
19 Sept 2023
25 Oct 2023
19 Sept 2023
18 Oct 2023
4 Oct 2023
Amount
Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness ( below or above ground level) of any description and removing rubbish to out side MD land complete all as specified and as directed.
M&L for 25 mm thick cement concrete 1:2:4, type B-0 (using 12.50 mm graded crushed stone aggregate), as in base course, to receive floor finishes, complete all as specified & directed.
Taking down cement plaster any description on brick or stone walls, RCC surfaces, etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified and as directed.
M&L rendering 15mm thick in cement mortar 1:6 internal on stone masonry surfaces , finished even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 10mm thick in cement mortar 1:3 on concrete ceiling /chajja/facia, finished even and smooth without using extra cement, complete all as specified and directed.
Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed.
M&L keyed pointing in cement mortar (1:3) to squared rubble masonry regular coursed or un coursed complete all as specified & directed.
M&L for Rendering 15 mm thick externally in cement mortar1:4 on stone masonry surfaces finished fair and even with out using extra cement including mixing with water proofing compound ( WPC) as per manufacturer instructions complete all as specified and as directed. Note :- WPC will be measured and paid separately as supply only.
M&L for Preparation of new plastered or unplastered surfaces of wall and applying three coats of white wash on wall surfaces complete all as specified and as directed.
M&L for Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling surfaces complete all as specified and as directed.
M&L Preparation of new plastered or un-plastered surfaces of walls and applying two coats of cement base paint over & including M&L single coat of white wash complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
Taking down steel windows and ventilators ( glazed / fly proof) of any description complete all as specified and as directed.
S/F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete with glazing bars, all as specified. Note:- (i)-:-Glass panes, guard bar & wire cloth shall be measured and paid seperately.
All as per item No. 14.00 here-in-above, but without glazing bar
M&L for mild steel work as in chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165, complete all as specified and as directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm complete all as specified and directed.
S&F of 4 mm thick pinheaded figured glass panes of size not. exceeding 0.5 Sqm fixed with oil putty complete all as specified and directed.
M&L preparation of steel surfaces of any description over 10cm width or girth not otherwise described and apply two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified & directed
M&L 50 mm thick PCC (1:3:6) type C-1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight complete all as specified & directed
Complete removal of existing water proofing treatment of any description including bedding up to the true surface of original concrete, in RCC roof slab / stone patty and roughening the old surfaces by picking, sweeping clean and washing down with water to remove dust etc including removing rubbish to out side MD land and provide plastring 10 mm thick in CM (1:4) finished even & smooth over the RCC roof slab / stone patty for laying of water proofing treatment using water proofing compound (WPC) as per manufacturer instructionand including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastred surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 3.00 Kg/Sqm using butane torch with minimum 10cm side lap and 15cm end lap complete (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen confirming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE : M&L 40mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate in roof padding , the surface of concrete is to be finished even and fair with out using extra cement NOTE :- WPC shall be measured and paid separately under respective
M&L for PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate in roof padding , the surface of concrete is to be finished even and fair with out using extra cement, over roof for making good depression/undulation and as in roof kerb to match the existing, complete all as specified and directed.
Supply only integral water proofing compound (ISI marked), complete all as specified and directed.
Demolition of stone / boulder masonry walling, built in cement mortar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and directed.
M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed.
Extra over stone walling for hammer dressing to face stone & dressing of face beds & joints as specified of squared rubble walling Jodhpur type brought upto courses with maximum depression of face from straight edge held against the dressed surface n exc 20mm and dressing face beds and joints, complete all as specified and directed.
M&L precast cement concrete block masonry using PCC 1:2:4, type B-1 solid blocks, 10 cm in width and setting in cement mortar 1:4, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed.
Taking down carefully cement conc /spalled out concrete from RCC roof projections, ceiling ,sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scafolding etc, complete all as directed.
S&F in replacement TMT bars 12 mm dia fixed by way of stitching ( welding ot tieing with existing reinf) incl drilling holes etc & securing ends in walls etc ,complete all as specified and as directed.
M&L for cleaning the existing reinf of slabs , chajjas etc & applying a coat of SIKA RUSTOFF 11 to remove the loose rust particles etc & throughly cleaning the surface.,complete all as specified and as directed.
M&L for applying a coat of bond coat made with cement slurry (1 part cement to 1.5 -2 parts water) mixed with admixture LATEX POWER mixed @5 Kg per 50 kg of cement & applying to the conc surfaces @ 200 gm/sqm to obtain tack.,complete all as specified and as directed.
M&L for 15 -20 mm thick rendering in CM (1:1:2) using1 part of cement 1 part 2-3 mm screenings of stone agg & 2 parts coarse sand over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & rough to receive final rendering coat. ,complete all as specified and as directed.
M&L for 10-15 mm thick rendering in CM 1:3 over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & smooth complete all as directed at site ,complete all as specified and as directed.
S&F GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/fascias etc,complete all as specified and as directed.
Demolition of reinforced cement concrete (including cutting of reinforcement) of any description for roof,colums ,beam of any type etc complete all as specified and directed (removing demolished material outside MD land).
Use and waste of formwork to sides and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n. exc. 200 mm thick (Horizontal or sloping) and similar works fair finished surfaces of concrete complete all as specified and as directed.
Form work to edge of concrete flats, treads, breaks in floors, window cills, concrete railing, opening in concrete walls, floor and roofs n exc 20 cm wide and side of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide with fair finished surfaces complere all as specified and directed.
Use and waste form work to sides and soffits of floor or roof beams, lintel, cantilevers, shelves etc. including support of fair finished surfaces, complere all as specified and directed.
M & L RCC design mix M-25 using 20 mm graded stone aggregate as in slab supported on wall, roof slab, chijja and in shelve etc complete all as specified and directed.
M & L RCC M-25 (design mix ) as in beam, cantilevers , bressummers, lintel overone meter span, complere all as specified and directed.
M&L TMT HYSD bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
M&L TMT HYSD bar 5 dia and over upto and including 10 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
M&L for Writing letters or figures (Black Roman, Italic or Indian n. exc 30cm high with thick paint complete all as specified
M&L factory Made flush shutters, 35 mm thick solid core with block board core construction as per IS 2202(part-I, 1999), one face is covered with decorative face veneer with lipping/frame to match & other face commercial type, stiles & rails shall be with out any joint and made with non- coniferous timber hard wood (Hillock/ Mirantee/ Bosum/ Benteak) with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process. The over all finished thickness of face panel shall not be less than 35mm while the thickness face veneer shall not be less than 0.6 mm complete all as specified and directed.
M & L Pressed steel frames of size 105X60mm of 1.25mm thick for doors with one or more rebates including necessary fixing lugs. hinges, lock strike plate,etc., complete all as specified and as directed.
S&F rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars barred iron doors; chowkhat, doors with MS sheet, ladders ;framed balusters walk ways railings framed work of water tanks and similar work confirming toFe-290Gde E-165 complete all as specified & directed
S & F floor door stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
S&F PVC door seal fixed at door to cover the gap between floor and door, complete all as specified and as directed.
M&L Machine cut kota stone slab 20 to 25mm thick in floor laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over and including 20mm thick screed bed in CM 1:6 including dismantling of stone slabs of any description complete all as specified and as directed.
M&L Machine cut kota stone slab 20 to 25mm thick in shevels laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over and including cutting chasing pinning & etc., including dismantling of stone slabs of any description complete all as specified and as directed.
All as per item No. 50.00 here-in-above, but as in skirting/dado over & incluuding M&L 10 mm thick CM 1:4
M&L for 7.5cms thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:3 or cement mortar 1:4, complete all as specified and as directed.
M&L 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floors & fixing of glass dividing strips & finishing the surface even & smooth with using extra cement complete all as specified & directed. Note:- Glass dividing strip shall be measured and paid seperately.
Supply only 38mm wide and 3mm thick glass dividing strip complete all as specified & directed
M&L for providing steel scafolding &formwork etc for supporting RCC Beams/columns etc for carrying out the rehabilitation works complete all as specified & directed . Note:- The steel scaffolding & formwork etc catered for in the items above is for supporting the RCC members during the period of their structural rehabilitation. The scaffolding & formwork shall not be removed until the RCC members have gained sufficient strength. The decision of GE shall be final conslusive & binding in respect of the extent to which the formwork is to be provided & time of its removal.
M&L for 200 mm thick QCC (Ready mix concrete) in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, complete all as specified and as directed.
M&L 100mm thick PCC 1:2:4 type B-1 by using 20mm graded crushed stone aggregate, as in flooring / for plat form for water tank on roof including necessary form work complete all as specified and as directed .
M&L for Plain cement concrete type B-0, 1:2:4(12.5 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M&L for Providing and jacketing the distressed concrete elements in patches using Single component, shrinkage controlled, polymer modified cementitious micro concrete such as Rendrock Laxtra of Fosroc make that achieves a compressive strength of 35 MPa in 3 days (BS 1881), Flexural Strength 09 MPa at 28 days as per BS 6319 Pt-3, Tensile Strength 3.5MPa in 28days as per BS 6319 Pt-7,by “Form & Pour” method inclusive of Manpower, Material and Equipment. Note:- The quoted rate shall be inclusive of providing necessary formwork all as specified & directed.
M&L 75 mm thick PCC 1:4:8 type D-2 using 20mm graded crushed stone aggregate, as in sub base of floor incld. compaction properly & universal and laid to level, complete all as specified and directed.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 80mm thick with 6 mm thick top layers of anti abrasive material of M-30 grade with any description, ( colour, design & pattern, & size/ shape, as approved by GE) as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including M&L 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
M&L for laying 40-50 mm thick Machine cut sand stone slabs as in Plinth protections laid over & iincluding M&L 20 mm thick cement sand screed in CM1:4 over 50 mm thick PCC, incl filling the joints of sand stone slabs with neat cement mixed with pigment to match the shade of slabs, complete all as specified and directed
Exposing existing RCC members such as columns, slabs, lintels, beams, etc. up to the main reinforcement carefully by means of Chisel & hammer, hard wire brushes or any other mechanical means, so as to remove all loose concrete and cleaning the surface to remove all dust particles, etc. and make the surface ready for chemical treatment in bone dry condition.
M & L RCC nominal Mix Type B1, 1:2:4 (20mm graded aggregate) using 20 mm graded stone aggregate as in beam, roof beam, cantilevers, lintel beam, etc. complete.
M&L Preparing new plastered or unplastered surfaces and applying with 1.5-2 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper over one coat of primer on walls complete all as specified and as directed.
M&L Preparing new plastered or unplastered surfaces or old decorated surface of wall and applying two coats of exterior plastic emulsion over & including one coat of primer on walls complete all as specified and as directed.
M&L GI frame work size of grid 605 x 605mm for seamless ceiling comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 & 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and inccluding ceiling section (not exceeding 1.2M length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel at 457mm c/c and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and including providing gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instructions over the frame work and preparation of ceiling board and applying two coats of oil bound distemper over a coat of 'Birla' wall / ceiling care putty including dismantling of existing false ceiling of any thickness with cover fillets complete all as specified and as directed.
M&L for prefabricated, pre moulded / reinforced, 100 to 125 mm wide strip POP moulded cornices/moulding, fixed on ceiling / wall, including necessary formwork, scaffolding, T&P and etc., complete all as specified and directed.
S&F in replacement 500 ltrs capacity rotational moulded polythene water storage tanks white colour, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms, including dismantling of old U/S PVC/RCC water tank & removing to store or outside MD land or credit to contractor, complete all as specified and as directed.
All as per Sl item No. 69.00 here-in-above, but size of tank 1000 liter capacity
All as per Sl item No. 61.00 here-in-above, but size & grade of paver block 60 mm thick & M-30 respectively
M&L rendering 5mm thick in cement mortar 1:3 on concrete ceiling /chajja/facia, finished even and smooth without using extra cement, complete all as specified and directed.
Disconnecting existing tanks setting aside [or lowering if required] for repairs,cleaning etc., and hoisting if required reconnecting and refixing in position of water tanks of capacity up to 500 litres and including cleaning and removing all scale dirt etc from mouths of circulating pipes of water tanks, complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets,fittings etc., removing materials to store for keeping in safe custody or for taking credit and including cutting, chasing, pinning & making good disturbed surfaces of walls,floors, etc, complete all as specified and directed by Engineer-in-charge.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed by Engineer-in-charge.
M&L Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits), with multi stranded copper conductor, nominal cross-sectional area is 1.5 sq mm , single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty drawn through and including in PVC rigid conduit with all accessories complete concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/prestressed steel sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light/ fan/bell point controlled by one, one way switch complete all as specified and directed . Note:- surface conduit shall be laid in ceiling portion only.
All as per Serial Item No. 76.00 here-in-above but for one 3 pin socket outlet 5/6 Amps on the same board with other switches.
All as per Serial Item No. 76.00 here-in-above but for one 3 pin socket outlet 5/6 Amps on the independent board with other switches.
All as per serial Item No. 76.00 here-in-above but for 15 Amp point on independent board with 4.00 Sqmm cable
S&F piano type Switch 1 way, 6 Amps, 1 module, 230 Volts complete all as specified and as directed.
S&F piano type Switch 1 way, 16 Amps, 1 module, 230 Volts complete all as specified and as directed.
S&F piano type Socket, 6 Amps, - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed.
S&F piano type Socket, 6 /16 Amps, - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed.
S&F piano type fan step regulator, 120 W - 2 module complete all as specified and as directed.
S&F lamp holder, PVC / polycarbonate type with back plate suitable for batten fitting, INCLUDING 9W LED Lamp complete all as specified and as directed.
S&F piano type Ceiling rose, surface bakelite, 3 terminal, 3 phase / PVC / Polycarbonate, isolated body complete all as specified and as directed.
S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), including taking down ceiling fan from its position, complete all as specified and as directed.
Supply & replacement of LED tube rod ( integrated driver), 6000K colour temp, 4 feet long of 20 watt ( PC) in existing tube light fitting, including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F in replacement bldg security LED Light Luminaire of 35 Watts having IP 65/66 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 160-260 Volts with in built surge protectore, toughened glass with and including GI pipe 20/25mm dia bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable, complete all as specified and directed.
Supply, fixing, testing and commissioning SPN 40 Amps 240V 10KA 'B' curve miniature circuit breaker (MCB) and current carrying capacity in the DB complete with connection, complete all as specified and as directed.
Supply, fixing, testing and commissioning SP 6 to 32 Amps 240V 10KA 'B' curve miniature circuit breaker (MCB) and current carrying capacity in the DB complete with connection, complete all as specified and as directed.
S&F factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar, SPN 4 way, 240V, IP-43 Protection, duly fixed in concealed in wall including cutting chasing pinning, and making good, suitable for for fixing MCB's complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron or steel and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (1991)incl dismanteling of existing unserviceable earth pit all as specified and directed by Engr-in-Charge.
Supply, laying, testing & commissioing of cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core including taking out old unserviceable cable if required., complete all as specified and as directed.
Supply and filling dry clean sand (tibba sand) in trenches for cushioning of underground cable and punning for cushioning to cable complete all as specified and directed . Note :- Punned thicknes only shall be measured for the purpose of payment.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of cable / pipe line etc and getting out in any type of soil complete all as specified and directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed.
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 300 mm x 180mm x 40mm complete laid over the cable perpendicular to the cable for protection, complete all as specified and as directed.
Supply and fix in replacement of GI tubing of size 40mm bore, medium grade for protection of cables on poles / under road crossing complete all as specified and as directed.
Note for item No. 21.00: - (i)- A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE (ii)- WPC shall be measured and paid separately under respective item..
Note for all items:- (i) Quantities are clubbed in BOQ for different Jobs.Details are mentioned as per annexure-I on Sl. page No. 37.
SNEH CORPORATION
GANGADHAN ENTERPRISES
M/S SUMAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .