REGULAR MAINTENANCE OF ELECTRICAL INSTALLATIONS UNDER E.R PLANT AND OTHER JOBS.
2019_HCL_35766_1
Enquiry No I-12263/WEB/CONT/BT
Open Tender
Miscellaneous Services
Works
365 days
HCL - ICC - Moubhandar
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10,030
Yes
10 Jan 2020
12 Nov 2019
6 Dec 2019
12 Nov 2019
3 Dec 2019
12 Nov 2019
Amount
Laying/Re-routing of 1.1KV grade PVC armoured cable of size Control cable of Size 2.5mm
Termination of 1.1KV grade cable 3.1/2C x 95 Sq.mm to 120 Sq.mm through suitable glands & lugs. The glands & lugs shall be supplied by the Contractor.
Termination of 1.1KV grade cable 4C x 16 Sq.mm. to 35 Sq.mm. through suitable glands & lugs. The glands & lugs shall be supplied by the Contractor.
Repair of 250W HPMV & above fittings by replacing reflectors, bulbs, choke & ignitors. The materials shall be supplied by HCL/ICC.The job includes opening & reinstallation of light fixture.
Supply & fixing of insulator at ends of cross line for tightening of cross wire. The insulator supply include tightening studs with pipe piece & brackets.
Repair of Below 250W light fittings. by replacing reflectors, bulbs, choke & ignitors. The materials shall be supplied by HCL/ICC.The job includes opening & reinstallation of light fixture.
Installation/testing & commissioning of TPN Switches above 63A upto 160A
Installation/testing & commissioning of TPN Switches above 160A to 250A.
Installation/testing & commissioning of TPN Switches 300A to 750A.
Installation of ON/OFF push button station.
Installation/overhauling/repairing of DOL/ Star delta starter MCC & clelaning/painting of the cubicle upto 30HP motor.
Installation, testing & commissioning of 63A TPN S/F unit
Dismantling, removal & shifjting from position to ERS safely & return back to position from ERS to site of Motors from 1HP to 20 HP (Appr. Wt. 5 Kg. to 40 Kg.)
Dismantling & refixing of 10" x 1" copper busbar
Opening of bolts, dismantling of busbar joints (10" x 1") (2 run joints pieces) double contract type, cleaning of surface of the joints & bussbar & refixing the same with proper alignment of busbarswith replacement of damaged bolts & nuts i
Opening of bolts, dismantling of busbar joints (10" x 1") (single joint type) double contract type, cleaning of surface of the joints & bussbar & refixing the same with proper alignment of busbarswith replacement of damaged bolts & nuts if
Supply & installation of DSL of MS angle for 3 Phase & neutral having angle Size 50 x 50 x 6.
Supply & installation of proper size of bracket & support insulator of porcelain type for DSL detailed under Sl.No.1.
Replacement of 15/20A tumbler switches/toggle switches or Rotary switches. from the existing lighting/welding DBs or any other place & necessary painting of the DBs after tit bit repair.
Excavation of earth pit in any class of soil including stones, slag etc. by 15' deep & refilling with charcoal, salt & good quality of soil. Approximate 60 Kg. salt & 60 Kg. charcoal should be used for each earth pit. 65 mm NB, 3.5 mtr l
Dismantling of following sizes of cable from cable tray/underground & its reeling for further use. The sizes of cables as under:- 1.1KV grade PVC armoured PVC inner & outer sheathed AYFY type cable below 25 Sq.mm. including control & po
Laying/Re-routing of 1.1KV grade PVC armoured cable of size 3.1/2C x 95 to 120 Sq.mm. PVC armoured cable.
Unbolting & dismantling of copper busbar from its existing points (including clamps, support & jointing bolts) size of busbar 12" x 1/2"/14" x 1/2" or 10" x 1" of red, yellow & blue phase busbar. Cleaning of all joints & contact surfaces p
Termination of 11KV XLPE/PILC cable by M.Seal termination kit/heat shrink type and straight through jointing (M.Seal type). The termination/striahgt through jointing kit shall be supplied by the Contractor. Size 3C x 150 Sq.mm.
Digging of cable trench and its refilling by excavated soil, sand and bricks after laying the cables. Size of trench 300mm x 950 mm depth.
Termination of 11KV XLPE/PILC cable by M.Seal termination kit/heat shrink type & straight through jointing (M.Seal kit).The termination/straight through joint kit to be supplied by the Contractor.Termination of 11KV cable 3Cx120-185 Sq.mm.
Laying/Re-routing of 1.1KV grade PVC armoured cable of following sizes:- 3.1/2C x 150 Sq.mm to 300 Sq.mm .
Termination of 1.1KV grade cable through suitable glands & lugs The glands & lugs shall be supplied by the Contractor. 3.1/2C x 150 Sq.mm to 300 Sq.mm.
Dismantling of following sizes of cables from cable tray/under-ground & its reeling for further use. The size of the cables :- 1.1 KV grade PVC armoured, PVC inner & outer sheated AYFY type cable 3.1/2C x 30 Sq.mm to 3.1/2C x 300 Sq.mm.
Cutting of road & placing of GI/MS pipe for cable laying & after laying the cable, the road repairs as per previous condition.
Laying/Re-routing of 1.1KV grade PVC armoured cable of following sizes:- 4C x 16 Sq.mm to 70 Sq.mm
Supply and installation of GI strip Size 40mm x 6mm for earthing.
Laying/rerouting (if necessary) of 11KV PILC/XLPE cable of 3C x 120 -150 Sq.mm.
Dismantling of any damaged structure, platform, cable tray or column related to electrical equipment, including pipe line of A.C etc.
Fabrication, erection & fixing of the structure, platform, cable tray, column etc including pipe line jobs. Necessary steel shall be supplied by HCL/ICC and necessary painting is under the scope of Contractor.
Installation & commissioning of 4 SWG/2 SWG bare copper wire for cross line of EOT cranes with proper tightening on insulator or intermittent support the job includes dismantling of existing wires.
REPLACEMENT/NEW-INSTALLATION OF CEILING FANS INCLUDING THEIR CONNECTION IN MOUBHANDAR QUARTERS/OFFICES OF ICC.JOB INCLUDES SHIFTING OF FANS FROM DEPTT AND RETURN OF OLD FAN TO DEPTT
INSTALLATION OF ELECTRICAL BOARDS (ABOVE 10× 8 INCH SIZE) IN MOUBHANDAR QUARTERS/OFFICES, JOB i/c CONNECTION/DISCONNECTION OF SUPPLY AND PROPER FIXING OF BOARDS AND INSIDE WIRING OF BOARD.THE MATERIALS SHALL BE SUPPLIED BY DEPTT
INSTALLATION OF ELECTRICAL BOARD (UPTO 10IN × 8 IN SIZE) IN MOUBHANDAR QUARTERS /OFFICES, JOB INCLUDES CONNECTION/ DISCONNECTION OF SUPPLY AND PROPER FIXING OF BOARDS AND INSIDE WIRING OF BOARD,THE MATERIALS SHALL BE SUPPLIED BY DEPTT
MAA CONSTRUCTION
ADITYA SALES CORPORATION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .