Loading…
Loading…
Tender ID
Tender Value
₹28 L
EMD Value
₹40,000
Closing Date
27 Jan 2026, 6:00 pmClosed
executive engineer kadodara division
Tender for work of laying,testing & commissioning of Xlpe cable and work of erection Ht,Lt, Tc and Service connection and as per REC norms for all scheme in the jurisdiction of Kadodara Ind Sdn under Kadodara division.
265912
KAD/O&M/EXP/N-Procure/2026/01/No.0024 date. 12-01-2026 SR. NO.03
Open
Electrical
Works
Surat
3 documents required · 3 mandatory
₹1,180
DAKSHIN GUJARAT VIJ COMPANY LTD.
₹40,000
17 Jan 2026
17 Jan 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
SCHEDULE-B ( UG CABLE INCLUDING O/H XLPE ,HT LT & TC ) under Kadodra Ind SDN under KADODARA Division
LABOUR RATE FOR UNDERGROUND CABLE WORK FOR FY 2024-25 (WITHOUT GST)
Sr. Item Code Description Unit Rate for
1 9925000001 Labour charge for excavation of cable trench of 400mm width x Meter
1200mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
2 9925000002 Labour charge for excavation of cable trench of 600mm width x Meter
1200mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
3 9925000003 Labour charge for excavation of cable trench of 400mm width x Meter
1500mm depth, in any type of soil for laying of cable of size up to
240 mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
4 9925000004 Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to Meter
240 mm2 & preparation of sand layer 100mm thick, in the cable
trench & covering the cable with 150 mm dia (Inner), thickness
25 mm, 1.0 meter long RCC half round muffs and providing and
fixing of 4inch width yellow colour polyethylene tape with
printing "CAUTION ELECTRIC CABLE BELOW" at 0.75 m depth
from ground surface after laying cable in trench. This will provide
indication that electric cable is passing underground so as to
protect cable from mechnical injuries, refilling the same, as per
Instruction of Engineer in Charge (EIC).
5 9925000005 Labour charge for horizontal drilling using Auger machine Meter
without damage to surface road at max 2.0 mtrs depth & putting
of 6.11 kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm
thickness H.D.P.E. pipe confirms to IS 4984-1987(3rd revision)
and BIS certification and laying of 11KV/22KV XLPE cable of size
up to 240 mm2 in HDPE pipe, as per Site Condition (excluding
cost of pipe). The detail map obtained from HDD machine and
excell sheet(hard and soft copy) indicating the respective depth
and distance from adjacent landmark for each segment for HDD
is must required to be submitted. HDD to be carried out at depth
1.5 mtrs to 2.0 mtrs as per site conditions and as per instruction
6 9925000006 Labour charge for horizontal drilling manually without damage Meter
to surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2
class-4,Green color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision) and BIS certification and
laying of 11KV/22KV XLPE cable of size up to 240 mm2 size, as
per Site Condition (excluding cost of pipe). The detail map and
excell sheet(hard and soft copy) indicating the respective depth
and distance from adjacent landmark for each segment of cable
to be submitted. Drilling to be carried out at depth Minimum
mtrs to 2.0 mtrs as per site conditions as per instruction of EIC.
7 9925000007 Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 Meter
mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS
certification for laying of underground 11KV / 22KV XLPE cable up
to 240 mm2 size.
8 9925000008 Labour work for RCC concreting on disputed location and CMT
repairing of damage portion of road crossing for the work carried
out for roads crossing as well as concreting & muffing of ploes
including all materials (1:2:4)
9 9925000009 Providing & fixing concrete stone route marker of 300 mm width No.
x 150 mm thick x 650 mm height embedded in earth at least
mm below & 350 mm above ground level respectively at distance
approx 50 meters along the length of cable. The RCC concreting
(1:2:4)(all necessary maeterials will be in bidder's scope) of route
marker is to be carried out 300 mm width x 150 mm thick x
mm below ground level as per instruction of EIC. The route
marker should be with name of company with approved yellow
colour-DGVCL. The distance from marker to cable and cable
depth with feeder name etc., marked with arrow sign is to be
painted on it.The route marker is to be fixed at location near to
any fixed permanent location (not necessary to fix exact on top of
cable) as per instruction of EIC.
10 9925000010 Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ No.
pole with cable connection arrangement along with fitting of
necessary fabrication for 11KV cable including excavation of pit &
refilling of earth as per instruction of EIC. (Exclusive of concreting
& muffing of poles)
11 9925000011 Erection of Single pole structure using 9 / 11 Mtr RSJ pole with No.
cable connection arrangement along with fitting ofnecessary
fabrication for 11KV/22 KV cable including excavation of pit &
refilling of earth as per instruction of EIC. (Exclusive of concreting
& muffing of poles)
12 9925000012 Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole No.
with cable connection arrangement along with fitting of
necessary fabrication for 11KV cable including excavation of pit &
refilling of earth as per instruction of EIC. (Exclusive of concreting
& muffing of poles)
13 9925000013 Erection of Single pole structure using 8.0 Mtr PSC pole with No.
cable connection arrangement along with fitting ofnecessary
fabrication for 11KV/22 KV cable including excavation of pit &
refilling of earth as per instruction of EIC. (Exclusive of concreting
& muffing of poles)
14 9925000014 Labour charge for erecting of 11kV / 22 kV XLPE cable of size up Per Job
to 240 mm2 on DP Structure with fixing of 02 Nos polymer
cleats on top and middle part.Polymer cleats, nut bolts etc.
fixing material to be provided by contractor.
15 9925000015 Providing & fixing of 6.11kg/cm2 , class-4,Green color, 110mm Per Job
O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS
certification on the erected DP structure for the mechanical
protection of cable by inserting the cable inside HDPE pipe. The
HDPE pipe shall be erected in such a way that 300mm shall be
below the ground level and the rest 2700 mm shall be
supported on the DP Structure with 01 No Polymer cleat.All
materials including polymer cleat and Nut bolt to be provided by
16 9925000016 Providing and fixing of pipe type earthing from 80 mm dia class-B No.
GI pipe with pit to be filled with salt & coke and construction of
chamber as per DGVCL Drg. No. dg /100 for DP and cable. The
earthing pit should be joined with cable by G.I. strip of size 1”
width & 2 mm thick. All material GI pipe, Coke, Salt etc will be
supplied by bidder.
17 9925000017 Supply & fixing of heat shrink type end terminations (outdoor) No.
for upto 11kV 3C x 185 mm2 size XLPE cable as per DGVCL
technical specification
18 9925000018 Supply & fixing of heat & shrinkable end terminations (outdoor) No.
for upto 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL
technical specification)
19 9925000019 Supply & fixing of heat shrink type end terminations (indoor) for No.
upto 11kV 3C x 185 mm2 size XLPE cable as per DGVCL technical
20 9925000020 Supply & fixing of heat & shrinkable end terminations (indoor) No.
for upto 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL
technical specification
21 9925000021 Supply & fixing of heat shrinkable straight through joint for upto No.
11kV 3C x 185 mm2 size XLPE cableas per DGVCL technical
22 9925000022 Supply & fixing of heat shrinkable straight through joint type for No.
upto 22kV 3C x 185 mm2 size XLPE cable as per DGVCL technical
23 9925000023 Labour charge for excavation of 2100mm long x 1200mm wide x No.
1200 mm deep joint pits for installation of 11kV / 22kV Straight
through joints as per instruction of engineer-in-charge &
covering the cable with 150 mm dia (Outer), thickness 25 mm,
1.0 meter long RCC half round muffs & refilling same as per
instruction of EIC .
24 9925000024 Providing and fixing of insulating bus bar, made from 11KV/22KV No.
XLPE cable after removal of semi conducting layer and applying
of PVC heat shrinkable anti-tracking core insulating tubing
(1.1KV), on both end terminal using Aluminium long barrel heavy
duty up to 240 sq mm lugs, Aluminium bus connector. Taping
with PG- clamp for bus conductor as per drawing and as per
instruction of EIC. The Alluminium lugs and PG clamp shall be
covered with 11KV/22KV HT insulating tapes.(11KV/22KV XLPE
cable will be in scope of DGVCL while all other materials will be in
bidder's scope)
25 9925000025 Testing of cable at various points and commissioning the feeder No.
as per instruction of engineer-in-charge.Test result shall be
submitted by contractor with bill.
26 9925000026 Preparation and submission of 6 (six) copies, of complete layout Set
drawings with GIS mapping as per actual cable routing showing
road crossing, HDPE pipe sleeving, jointing locations, markers
27 9925000027 Providing and fixing of Sign Board at junction point Made out of 2 No.
mm aluminium sheet size 750x300 mm (2.5 x 1ft) rectangle, as
per design, pre treated with phosphate process and acid etching
coated with one coat of epoxy primer and two coats of best
quality paints, refloctrorised with Hi-Intensity retro – reflective
sheeting as per the latest and frame fabricated from suitable size
iron angle. The Sign Board is to be fixed on the base prepared
from channel and bracing angles which is grouted by means of
cement concreting of 1:2:4 for size of 300 mm dia x 800 mm
height (500 mm to be grouted in ground). The details to be
displayed on sign board will be given by In-charge Engineer.(a) Hi
intensity Micro prismatic Grade
28 9925000028 Providing and fixing of Sign Board (Danger Board) on Distribution No.
Transformer Centers
Made out of 2mm aluminium sheet size 300x300mm (1x1ft) as
per design, pre treated with phosphate process and acid etching
coated with one coat of epoxy primer and two coats of best
quality paints, refloctrorised with Hi-Intensity retro-reflective
sheeting as per the latest and frame fabricated from suitable size
iron angle. The Sign Board (Danger Board is to be fixed at the
location as per instruction of In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
29 9925000029 Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm No.
(W) from 3 mm aluminium sheet along with 1.0 mm dia
aluminium binding wire for fixing of aluminium tag near end
termination joint at DP structure for identifyng the cable. The
details of feeder i.e. 11 / 22 KV with feeder name shound be
punched on the tag by letter punch of size 16 mm as per
instruction of In-charge Engineer.
30 9925000030 Supply & fixing of heat shrink type end terminations (outdoor) No.
for 11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical
31 9925000031 Supply & fixing of heat & shrinkable end terminations (outdoor) No.
for 22 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical
32 9925000032 Supply & fixing of heat shrink type end terminations (indoor) for No.
11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical
33 9925000033 Supply & fixing of heat & shrinkable end terminations (indoor) No.
for 22 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical
34 9925000034 Supply & fixing of heat shrinkable straight through joint for 11kV No.
3C x 240 mm2 size XLPE cableas per DGVCL technical
35 9925000035 Supply & fixing of heat shrinkable straight through joint type for No.
22kV 3C x 240 mm2 size XLPE cable as per DGVCL technical
36 9925000038 Installation, Testing and commissioning of 11 KV,630 A SCADA No.
Compatible, RRL type- 3 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
37 9925000039 Installation, Testing and commissioning of 11 KV,630 A SCADA No.
Compatible, RRLL type- 4 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
38 9925000040 Installation, Testing and commissioning of 22KV,630 A SCADA No.
Compatible, RRL type-3 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
39 9925000041 Installation, Testing and commissioning of 22KV,630 A SCADA No.
Compatible, RRLL type-4 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
40 9925000042 Construction of plinth for 11KV, RRL type- 3 Way (i.e Two No.
numbers of Isolator & One number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:
Drg. 11kv-01. All required material will be supplied by contractor.
41 9925000043 Construction of plinth for 11KV, RRLL type- 4 Way (i.e Two No.
numbers of Isolator & Two number of Breaker)Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:Drg.
11kv-02.All required material will be supplied by contractor.
42 9925000044 Construction of plinth for 22KV, RRL type- 3 Way (i.e Two No.
numbers of Isolator & One number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:
Drg. 22kv-01. All required material will be supplied by contractor.
43 9925000045 Construction of plinth for 22KV, RRLL type- 4 Way (i.e Two No.
numbers of Isolator & Two number of Breaker)Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:Drg.
22kv-02.All required material will be supplied by contractor.
44 9925000046 Modifications e.g.Providing and fixing of Terminal protectors i.e. No.
Re-use able boot (HT Side 11/22KV, LT Side 1.1KV) including
11/22 KV insulating taps and L.T.(1.1 KV) insulating taps ,Busbar,
Tapping from Bus Bar (11/22 KV XLPE cable) through P.G. Clamp
for H.T. Jumper to D.O. Fuse to bushings of Transformer Center,
providing & Fixing of jumper and providing & fixing of Heat
Shrinkable Anti Tracking Core Insulating Tubing (Insulation Level
11/22 KV) in H.T. jumper , Clamping arrangement of cable
support frame on both side of existing Over Head type
Distribution Transformer to utilize in Under Ground cable
network as per drawing & as per instruction of Engineer incharge.
All live parts i.e. PG-Clamp, connections of D.O.fuses, HT
bushings etc . shall be covered with fixinng of 11/22 KV HT
insulating tapes. ( 11/22 KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope ) .
45 9925000047 Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade Per Cable
trench or in open space Per Mtr
46 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
47 9925000064 Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long No.
RCC half round pipe
Note: 1.DGVCL will provide key material like M.S. materials,ABC/Bare
conductors,PSC/RSJ Poles,Insulators,Fabricated
materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL approved
drawing and by welding rods confirming to the relevent ISI
specification and as directed by Engineer in charge.
3.Necessary electricity connection for fabrication items shall be
provided by DGVCL on payment of required charge for
connection & electricity bill of the same shall be paid by the
4.All the rates are inclusive of PF & Exclusive of GST applicable
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the
paints on to the RSJ poles & steel fabricated materials of RSJ/PSC
poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be
properly painted for the RSJ poles & steel fabricated materials of
(c) Two coats of approved ISI mark silver paint (i.e. triple
mangoes or equivalent quality silver paint) is to be properly
painted on to the RSJ poles & steel fabricated materials of
Sr. Item Code Description Unit Rate for
1 9926000001 HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF No.
CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS AND NUMBERING COMPLETE WITH
COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
2 9926000002 ERECTION OF PSC POLES OF 8 *200 KG INCLUDING EXCAVATION No.
OF PIT AND REFILLING OF EARTH, FIXING OFCROSS ARMS, TOP
FITTING CLAMPS ANTI-CLIMBING DEVICES, INSULATORS ETC.
COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.
3 9926000003 ERECTION OF STEEL POLES OF 9 TO 11 METERS INCLUDING No.
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OFCROSS
ARMS, TOP FITTING CLAMPS ANTI-CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF STEEL
POLE, FABRICATED MATERIALS USED ON THE POLEAND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
4 9926000004 ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY No.
CROSSING ON BG/MG/NG LINE FOR 0.400/11/22KV OVERHEAD
LINES I.E INCLUDING EXCAVATION OF PIT & REFILLING OF EARTH,
FIXING CROSS ARMS, TOP FITTING CLAMPS,ANTI-CLIMBING
DEVICES DANGER BOARD, INSULATORS ETC. COMPLETE AND
PAINTING OF STEEL POLES, FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.
5 9926000005 ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS 200 KG No.
PSC POLES INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS, SUPPORTING ANGLES,CLAMPS,
ANTI-CLIMBING DEVICES DANGER BOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.(WITHOUT AB SWITCH)
6 9926000006 ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO 11 No.
METERS.STEEL POLE INCLUDING EXCAVATION OF PITS &
REFILLING OFEARTH, FIXING OF CHANNELS, SUPPORTING
ANGLES, CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARDS,
INSULATORS ETC.COMPLETE & PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND NUMBERING WITH COST
OF PAINTSAS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.(WITHOUT AB SWITCH)
7 9926000007 ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB No.
SWITCH, HG FUSES OF 8 MTRS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF EARTH,FIXING OF
CHANNELS SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING
DEVICES, DANGER BOARDS, INSULATORS,DOFUSES ETC.
COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDINGOF ERECTION OF GUY
SET AND EARTHING.(WITH AB SWITCH)
8 9926000008 ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB No.
SWITCH,HG FUSES, 9 TO 11 METERS STEEL POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF EARTH, FIXING
OFCHANNEL, SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING
DEVICES , DANGER BOARDS, INSULATORS, ETC. COMPLETE AND
PAINTING OF POLES FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.(WITH AB SWITCH)
9 9926000009 ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING No.
OFAB SWITCH, HG FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF 8 METER,200KG PSC POLE
METERS POLES INCLUDING EXCAVATION OF PITS AND REFILLING
OF EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS
ARMS CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING
OF FABRICATED MATERIALS USEDON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
10 9926000010 ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB No.
SWITCH,HG FUSES TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS STEEL POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE, FIXINGOF CHANNELS
SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS,
ANTICLIMBING DEVICES, DANGER BOARDS,CONDUCTOR AND
CABLE WIRING ETC. COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING
AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTIONS
OF GUY SETS AND EARTHING.
11 9926000011 ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS & No.
REFILLING OF EARTH AS PER STANDARD SPECIFICATION WITH
STAY CLAMPS, STAY WIRE, ANCHOR ROD, TURN BUCKLE,
EYEBOLT, GUY INSULATOR, CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
12 9926000012 CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF CMT
CEMENT SAND METAL (1:2:4) AND WATER ETC. AS PER
STANDARD SPECIFICATION.(cement Should be 53 grade) used for
13 9926000013 ERECTION OF COIL TYPE EARTHING INCLUDING COST OF No.
COAL,SALT ETC. BUT WITHOUT COST OF GI WIRE AS PER
STANDARD SPECIFICATION(20kg solt+20kg coal)
14 9926000014 ERECTION OF GI PIPE/CI PLATE TYPE EARTHING INCLUDINGCOST No.
OF COAL SALT ETC. BUT WITHOUT COST OF PIPE/GIPLATE GI
WIRE AS PER STANDARD SPECIFICATION.(20kg solt+20kg coal)
15 9926000015 ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH CLAMPS, No.
BRASS NIPPLE, BRASS HOLDER TECK WOOD BUSH,REFLECTORS
FUSE, WIRING ETC. AS PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
16 9926000016 STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA ONE
CONDUCTOR for ALL TYPE OF CONDUCTOR (EXCEPT DOG COND
CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING OF PER KM
INSULATORS, BINDING JUMPERING ETC.
17 9926000017 STRINGING OF GI WIRE 8 SWG INCLUDING BINDING JUMPERING DO
18 9926000018 PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC No.
2.5/4MM2 TWIN CORE CABLE FROM TERMINAL POLE TO
METERING POINT INCLUDING FIXING OF METER WITH METER
EARTHING COMPLETE WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
19 9926000019 PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION WITH No.
PVC 4MM2/10MM2 FOUR CORE CABLE FROM TERMINAL POLE
TO METERING POINT INCLUDING FIXING OF METER WITH METER
EARTHING COMPLETE WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
20 9926000020 ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA No.
FOR ERECTION OF POLE/ GUY ETC. AS PER STANDARD
SPECIFICATION OVER & ABOVE NORMAL COST COVERED
AGAINST EXCAVATION OF PIT UNDER NORMAL SOIL FOR
ERECTION OF POLE,GUY, DOUBLE POLE STRUCTURE EARTHING
WITH THE APPROVAL OF SUPDT.ENGINEER.
21 9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL CROSSING. MTR
22 9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL CROSSING. MTR
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
25 9926000025 Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD No.
CROSSING,HT LINE CROSSING AND TELEPHONE LINE CROSSING
26 9926000026 ERECTION OF SINGLE POLE STRUCTURES WITH , HG No.
FUSES,TRANSFORMERS, LIGHTENING ARRESTOR, DISTRIBUTION
BOX. ON 8 METERS 200 KGAND PSC POLE INCLUDING
EXCAVATION OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR AND
CABLE WIRING ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLE AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
27 9926000027 ERECTION OF SINGLE POLE STRUCTURES WITH MOUNTING OFAB No.
SWITCH , HG FUSES,TRANSFORMERS, LIGHTENINGARRESTOR,
DISTRIBUTION BOX. ON 9 to 11 METERS RSJ POLE INCLUDING
EXCAVATION OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR AND
CABLE WIRING ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLE AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
28 9926000028 ERECTION OF PSC POLES OF 10 *270 KG INCLUDING EXCAVATION No.
OF PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP
FITTING CLAMPS ANTI-CLIMBING DEVICES, INSULATORS ETC.
COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET AND EARTHING.
29 9926000029 ERECTION OF DOUBLE POLE STRUCTURE OF 10 METERS 270 KG No.
PSC POLES INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS, SUPPORTING ANGLES,CLAMPS,
ANTI-CLIMBING DEVICES DANGER BOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.(WITHOUT AB SWITCH)
30 9926000030 STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR FOR ONE
11/22KV & LT LINES INCLUDING FIXING OFINSULATORS, BINDING COND
JUMPERING ETC. PER KM
31 9926000031 STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT LINES ONE
INCLUDING FIXING OF INSULATORS, BINDING JUMPERING ETC. COND
32 9926000032 ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OF No.
AB SWITCH, HG FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF 10 METERS 270 KGAND
PSC POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS
ARMS CLAMPS, ANTI-CLIMBING DEVICES,DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING
OF FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
33 9926000033 DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF No.
FABRICATION AT STORE & STACKING OF POLE SAFELY ON ROAD
SIDE OR CREDITING TO DEPARTMENTAL STORE
34 9926000034 DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF No.
FABRICATION AT STORE & STACKING OF POLE SAFELY ON ROAD
SIDE OR CREDITING TO DEPARTMENTAL STORE
35 9926000035 DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) No.
(WITH TRANSFORMER) WITH CREDITING OF FABRICATION &
TRANSFORMER AT STORE & STACKING OF POLE SAFELY ON ROAD
SIDE OR CREDITING TO DEPARTMENTAL STORE
36 9926000036 DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) No.
(WITHOUT TRANSFORMER) WITH CREDITING OF FABRICATION
AT STORE & STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE
AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH
CABLE BY INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED
BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND
TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE.
39 9926000039 STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM KM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, BINDING
TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE
40 9926000040 STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM KM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, BINDING
TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS
REQUIRED AND DIRECTED BY ENGINEER IN CHARGE
41 9926000041 STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ KM
MM INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND
TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE.
42 9926000042 DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING THE No.
OLD MATERIAL TO STORE
43 9926000043 DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG No.
PSC POLE(WITHOUT TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
44 9926000044 DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG No.
PSC POLE(WITH TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
45 9926000045 DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND KM
CREDITING FITTING OF ALL ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
46 9926000046 DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND KM
CREDITING FITTING OF ALL ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND
CREDITING FITTING OF ALL ACESSARIES TO DEPARTMENTAL
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35
SQ MM AND CREDITING FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ
MM AND CREDITING FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
50 9926000050 RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG ONE
CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING OF COND
INSULATORS, BINDING JUMPERING ETC. PER KM
51 9926000051 RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES ONE
INCLUDING , BINDING JUMPERING ETC. COND
52 9926000052 LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR METER. No.
(METER WILL BE PROVIDED BY DGVCL)
53 9926000053 LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER AND No.
OLD METER SHOULD BE CREDITED TO SDN STORE. (METER WILL
BE PROVIDED BY DGVCL)
54 9926000054 LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER PER CT
CONNECTION. (CT COIL WILL BE PROVIDED BY DGVCL)
55 9926000055 LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR METER PER CT
CONNECTION AND OLD CT SHOULD BE CREDITED TO SDN STORE.
(CT COIL WILL BE PROVIDED BY DGVCL)
56 9926000056 LABOUR CHARGE FOR FIXING OF MMB FOR DTR METER (MMB No.
WILL BE PROVIDED BY DGVCL)
57 9926000057 LABOUR CHARGE FOR REPLACEMENT OF DTR METER BOX. No.
(METER WILL BE PROVIDED BY DGVCL)
58 9926000058 PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER No.
CABLE 3.5 METER (CABLE TO BE PROVIDED BY AGENCY)
59 9926000059 LABOUR CHARGE FOR PROVIDING/RECONNECTION OF TERMINAL PER
CONNECTION WITH PROPER SIZE OF LUGS. (LUGS COST IS BORNE TERMINA
BY AGENCY) TION
60 9926000060 LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH PER DTR
DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN COPY BY
SURVEYOR PERSON OF AGENCY IN PRO-FORMA REPORT SHOULD
BE SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PARAMETER OF
VOLTAGE, CURRENT & LOAD AS SHOWN IN PER-FORMA IS
FILLED) AS PER THE INSTRUCTION OF ENGINEER IN-CHARGE.
61 9926000061 LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH PER DTR
DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN COPY BY
SURVEYOR PERSON OF AGENCY IN PRO-FORMA REPORT SHOULD
BE SUBMITTED TO SDN OFFICE. (DULY FILL PER-FORMA IN FAULT
CONDITION IN WHICH READING PARAMETER IS NOT SHOWN IN
62 9926000062 INSTALLATION OF DTR METER INCLUDING METER BOX, No.
PROVIDING & FIXING OF 1.5SQ MM SINGLE STRAND 10 CORE
ARMOURED COPPER CABLE (3.5METER), TERMINATION IN
METER & COIL ETC.(METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
63 9926000063 INSTALLATION OF DTR METER INCLUDING METER BOX, No.
TERMINATION IN METER & COIL ETC. (WITHOUT 10CORE COPPER
CABLE) (METER, METER BOX, C.T./P.T. COIL WILL BE PROVIDED
64 9926000064 Binding of messanger Conductorat with a distance not more No
than 0.75 mtr with 6 turns minimum on XLPE Cable with single
strand binding wire (including cost of binding wire)
65 9926000086 Supply and Installation of 11/22 kV Distribution Transformers HT PER SET
Terminal protector (UV Resistance) with using 95/120/150 sq.mm
long barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y, B)
66 9926000087 Supply & Installation of HT EPR Tap on 11/22 kV Distribution PER SET
Transformer with replacement of bare conductor by HT ABC
conductor (DO bottom side to transformer) after removal of semi
conductor by HT ABC (6 inch both side). HT ABC to be supplied by
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
67 9926000088 Supply, Installation, Testing and Commissioning of Maintenance NO
Free, Ready Capsule, Pipe-In-Cage (Pic) Type, Earth Electrodes for
HT Feeder Pole Having 2000 mm Electrode Length as per the
Tender Specifications and Drawing. (All Materials Will Be
Supplied By Agency)
68 9926000089 Supply, Installation, Testing and Commissioning of Maintenance NO
Free, Ready Capsule, Pipe-In-Cage (Pic) Type, Earth Electrodes for
HT Feeder Pole Having 3000 mm Electrode Length as per the
Tender Specifications And Drawing. (All Materials Will Be
Supplied By Agency)
69 9926000090 Supply and Installation of 25 X 3 mm GI Strip having hot dip- Meter
galvanized-zinc coating of 80-100 microns without any joints or
welding. Both the end of the GI strip should be connected with GI
nut bolts and required fabrication work for giving separate
earthing connections to
(1) Neutral of the transformer
(2) MS structures of the transformer center (Approximately
meter GI strip per transformer centre
- as per requirement and instruction of Engineer in- charge)
(All Materials will be supplied by Agency)
70 9926000092 Supply and Installation of uPVC standard make Pipe of 1.25" Meter
diameter for covering GI strip with UV protected Cable Ties of
550 X 7.6 mm size to bind with pole face(Approximately 25 meter
uPVC pipe for GI strip covering per transformer centre -as per
requirement and instruction of Engineer in-charge.
71 9926000093 Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Per TC
Drop out Fuse and Drop out fuse to Transformer H.T. including
Busbar (12 mm sleeve) as per technical specification. (All
Materials will be supplied by Agency)
72 9926000100 Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Per TC
Drop out Fuse and Drop out fuse to Transformer H.T. without
Busbar (12 mm sleeve) as per technical specification. (All
Materials will be supplied by Agency)
73 9926000094 Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Per TC
Drop out Fuse and Drop out fuse to Transformer H.T. including
Busbar(15 mm sleeve) as per technical specification. (All
Materials will be supplied by Agency)
74 9926000101 Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Per TC
Drop out Fuse and Drop out fuse to Transformer H.T. without
Busbar(15 mm sleeve) as per technical specification. (All
Materials will be supplied by Agency)
75 9926000095 Supply & fixing of Disc type Red Color FRP(Non-flammable) NO
material with Weather resistant, Non-conductive bird guard
OD=300 MM, ID=33 MM, Width =1.25 MM, one side cut from ID
to OD. (All Materials will be supplied by Agency)
76 9926000096 Providing and fixing of LT Terminal protectors i.e. Re-useable No
boot (LT Side 1.1 kV) including LT (1.1 kV) insulating taps. All live
part at LT side shall be covered with fixing of LT insulating taps.
77 Nylon Net around Transformer Center
77.1 9926000097 Nylon Net (12 * 15 ft) Per Net
77.2 9926000098 Nylon Dori Per TC
77.3 9926000099 Labour charge for fitting Nylon Net (All fabricated material for Per TC
fitting nylon net shall be provided by DGVCL)
Total Rs.2800000
Executive Engineer (O&M)
DGVCL,Kadodara Division.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Notice.pdf
Integrity Part - Copy (3).pdf
Technical Specification.pdf
DRAFT TENDER CONDITION.pdf
SCHEDULE-B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .