Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹17.5 L+₹1.5 L (9.61%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
5 Mar 2022, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
CERTAIN B/R AND E/M REPAIR WORK IN E/M INSTALLATION AND PUMP HOUSE UNDER GE (I) RND DEHRADUN
2022_MES_507608_1
GE(I)RND/9106/E8/21-22
Open Tender
Civil Works
Item Rate
180 days
DEHRADUN
Class E Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2020) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
GE I R N D DEHRADUN
₹40,000
Yes
12 Mar 2022
12 Feb 2022
7 Mar 2022
12 Feb 2022
5 Mar 2022
19 Feb 2022
12 Feb 2022 - 19 Feb 2022
Amount
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15cm thickness (above or below ground level floors) complete all as specified and directed
M & L 75 mm thick for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in subbase for laying floor finishes / plinth protection etccomplete all as specified and directed.
M&L for 4 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane(work will be carried out for 2nd to 6th floor) complete all as specified and directed.
S&F 4mm thick figureed glass , pin headed type and glazing with oil putty in squares of any description not exceeding .5 sqm in each pane (work will be carried out upto 4th floor) complete all as specified and directed.
S&F Powder Coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary jointing cleats/ glazing clips, rubber neoprene packing, handles 2 Nos in each door , locking arrangment, aluminium snap beading screw etc, complete all as specified and directed. ( minimum thickness of powder cated should be 50 micron)
S&F Powder Coated aluminium window and ventilator shutters side hung type without sash bars, , aluminium section weighing 0.55kg/m including necessary jointing cleats/ glazing clips, rubber neoprene packing, anodised aluminium snap beading , screws, anodised aluminium fittings such as peg stay 150mm long (1 No) hinges type B-21 100mm long ((2 Nos) suitable handle (1 No) complete all as specified and directed.
S&F Powder Coated aluminium frame for doors, windows or partition including aluminium beading, hinges of required size,jointing cleats, screws, dash,fastners,plug for fixing with wall, columns etc complete all as specified.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified.
Taking down existing double action floor spring hydraulically regulated and Refixing only after necessary repairs, oiling & greasing etc in proper position with and including proper screw complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from frame) not exc. 1.50 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from frame) exc. 1.50 sqm and but n exc 4 sqm each complete all as specified and directed.
Taking down shutters of any description and make exc. 1 sqm and not exc 2 sqm each complete all as specified and directed.
S & F with wood free EPS,Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing,etc including 02 Nos handle, 02 Nos but hineges and 02 Nos tower bolts complete all as spd and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all of specified and approved by GE.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets Complete all as specified and directed
S & F in repair 1.25mm thickness of laths steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, haps and staple and one shop coat of primer erected in position as indicated, complete : push pull or manual type complete all as spd and directed
S&F for framed work such as grills, gratings, etc.. With ends of bars shouldered and riveted, or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con-forming to Fe. 290. Gde-E-165. Note (ii) :- Work will be carried out upto 6 story in necessary scafolding and safety measures and labour insourance etc complete.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20 mm dia pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 15 mm dia pipes complete all as specified and directed.
S&F for laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F for laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills sunshades, shelves lintels etc and cutting chases for concealed water pipe etc and making good cutting not exc 10cm.complete all as specified and directed.
Disconnecting & taking down existing water tank of capacity exc 500 liter and not exc. 1000 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 1000 lts capacity (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed.
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys , scrubing down with water etc, complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete /brick surface in cement mortar 1:6 finished fair and even as in wall complete all as specified and directed.
M&L for Rendering 10 mm thick on fair faces of concrete /brick surface in cement mortar 1:3 finished even and smooth without using extra cement as in ceiling and similar other work complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item of sch A / BOQ
M&L two coat of oil bound distemper of required tint on newly plastered surfaces of wall after prepration of surface and over a coat of 3 mm thick wall care puttty complete all as specified and directed.
M&L three coat of white wash on newly plastered surfaces of ceiling including prepration of surface complete all as specified and directed
Preparation of new plastered surfaces of walls and concrete work and applying two coats of cement based paint over a coat of Primer complete all as specified and directed.
S&F in repair PVC water tank covers screw head type including four Nos of PVC nut and bolt in existing PVC water tanks of capacity 500 ltrs to 1000 ltrs capacity with fixing arrangement complite all as specified and directed.
Taking down shutter exc. 1 Sqm and n.exc 2 Sqm each and refixing the same opening after resecuring or easing and adjusting shutters of any description. complete all as specified and directed.
M&L for 40 mm thick flush shutters, solid core construction, exterior grade with block board core and plywood face, pannels, commercial type on both sides and one face is covered withdecorative face veneer with lipping / frame to match, including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
S&F in repair plain aluminium sheet, 0.56 mm thick lining to bottom rail of toilet / bath door shutters and straight flashing, fixed with brass, chromium plated screws etc complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
M&L for taking down/dismantling of existing roof treatment of any description such as PCC Padding/ Coba treatment/ mud phuska/Lime conc terracing including screed bed etc. Hessian base felt/tar felt etc. (any type and thickness) complete all as specified & directed.
Removal of demolished materials to a distance exceeding 250 Mtr but not exceeding 500 Mtr and deposting where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed .
M & L for water proofing treatment on roof slab including picking ,sweeping ,clean and washing down with water to remove dust & providing water proofing treatment described as under :- (a) Surface preparation and treating construction joints, filling of honey combs,preparation of coving ( if required ) with Asian paints smartcare Repair Mortor and Asian Smartcare General purpose Grout of Asian paint or equivalent product of THERMAX / FOSROC . (b) Cleaning the surface and appling Asian PU Magnum primer Resin & hardner of Make Asian paints or eqivalent product of THERMAX / FOSROC on the cleaned surface. (c) Appling Asian Smartcare PU Magnum of Make Asian paints in Two ( 2 ) layers ( PU Magnum per coat should be minimum of 600 gms per Square meter or equivalent product of THERMAX / FOSROC. ( d). Ponding test of 72 Hrs and no leakage/ seepage observed. Any rectification to be done at the cost of contractor repeating above stepsof application. (e) . The work shall be carried out complete as per manufacturer's specification and application methodolgy. (f) . Word of Execution to be done with authorised applicator of the manufacturer and company bank gurantee to br given by the contractor after completion of water proofing work befor payment. work will be executed in Smart Assurance System of manufacturer company of Asian/ Epoxy/ Polymer chemicals.
Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement) complete all as specified and directed.
M&L for removing the plants/ vegetation upto Six story height including penefreated roots complete and injecting chemical GLYPHOSPHATW 41% SL 20 ml or till refusal by makimg cut/ injection in the stem of plant 30mm C/C spraying with solution (25ml Glyphospoto 41% diluted with one litre water) including necessary scaffolding etc wk will be carried out upto 6 th storey buildigs complete all as per specification and directions.
Taking down chowkhats with shutters (without taking off shutters from frame) not exc. 1.50 sqm each complete all as specified and directed.
S&F powder coated aluminium sliding window two track with two glass shutters aluminium powder coated section aluminium cleat, PVC track, bearing, handle locking arangement, rubber beading etc complte fittings as approved. Note Size of aluminium section shall be under :- (i) Two track top and vertical - Jindal main-2010 section No 20829 or equivalent make as approved by GE. (ii) Two track bottom- Jindal main-2010 section No 20830 or equivalent make as approved by GE. (iii) Shutter vertical section- Jindal main- 2010 Section 20606 or equivalent make as approved by GE. (iv) Shutter top and bottom - Jindal Main-2010 Section 20604 or equivalent make as approved by GE. (v) Shutter vertical middle (interlock) -Jindal Main-2010 section 20605 or equivalent make as approved by GE.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150 mm size complete all as specified and directed.
S&F floor door stopper double leg of aluminium alloy body of 140 mm length with aluminium base plate of size 50 mm x 40 mm complete all as specified & directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
S&F 25 mm dia, brass, knobs for cupboard fixed with nut, screw and washer of mild steel, bright finised complete all as specified and directed.
S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting for cabinets fixed with screws complete all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flap (when open) 30 mm complete all as specified and directed.
S&F 19 mm thick Solid PVC board fixed with steel screw and synthetic adhesive both one side balancing color texture used for shutter of the cabinet / cupboard and all as spd and directed. Note :- Colour will be approved by GE/Engr-in-Charge.
S&F 19 mm thick Solid PVC board fixed with steel screw and synthetic adhesive both side balancing white texture used for shutter of the cabinet / cupboard complete and all as spd and directed
M&L for complete removal of existing treatement by scraping, washing, rubbing down or stopping distempered or painted surfaces etc of walls plastered or un-plastered & removing all vegetation growth, cleaning & applying of Birla/JK white wall putty approx 1 mm thick in two layers as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed.
M&L for preparing old surfaces of walls plastered or un-plastered by brooming down with steel or wire brush and scraping down smoke soot, moulds moss & efflorescent salt and trading oil and greasy spots , washing rubbing down and stopping of distempered and painted surface & removing all vegetation growth, nails and making good holes,cracks etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying Two coats of cement base paint on old prepared surfaces of walls complete all as specified and directed.
M&L for preparing of old painted steel surfaces over 10cm width or girth and making good with & including by necessary red lead putty and make the surface smooth by rubbing with sand papers etc and applying one coat of synthetic enamel paint on old prepared surfaces of steel complete all as specified and directed.
M&L for preparing of old painted wooden surfaces over 10cm width or girth and making good including knotting and stopping,cleaning etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying two coat of synthetic enamel paint on old prepared surfaces of wooden complete all as specified and directed.
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified make for one light/Fan point controlled by one Switch.
All as per Srl item No 2 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches omplete all as specified and directed.
All as per Srl item No 2 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed.
All as per item No 2 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Make of cable and conduit: Havells/ Plaza/ Kalinga. make as approved by GE.
All as per item No 2 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Make of cable and conduit: Havells/ Plaza/ Kalinga make as approved by GE. Note for item 2 to 6 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (ii) Rate for modular metal flush boxes ,inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii) Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade (v) Make of cable : Finolex /Havells/ Poly cab as approved by GE.(vi) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE.
S&F Modular switch piano single pole one way 6 amp complete. Make -Legrand / Anchor Penta / Havells as approved by GE.
S&F Modular switch piano single pole one way 16 amp complete. Make - Legrand / Anchor Penta / Havells make as approved by GE.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete. Make -Legrand / Anchor Penta / Havells make as approved by GE.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete. Make -Legrand / Anchor Penta / Havells make as approved by GE.
S&F ceiling rose 3 plates polycarbonate, isolated body complete. Make - Legrand / Anchor Penta / Havells make as approved by GE.
S&F Angle holder, insulated polycabonate body with back plate suitable for batten fittings suitable for One number LED lamp 9/10 Watt. Make of holder - Legrand / Anchor Penta / Havells.Note: The cost of LED Bulbs are not included in this item make as approved by GE.
S&F modular fan step regulator 120 W 2 module complete. Make: Legrand / Anchor Penta / Havells make as approved by GE.
Supply and fixing in reolacement of UNSV LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete, all as specified and as directed. Make - C&G/ philips/ Bajaj/Havells make as approved by GE.
Supply and fixing in replacement of UNSV LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, all as specified and as directed by GE. Make - C&G/ philips/ Bajaj/Havells make as approved by GE.
Supply and fixing in replacement of UNSV LED lights fitting 1x 22W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, all as specified . Make - C&G/ philips/ Bajaj/Havells make as approved by GE.
Supply and fixing in replacement of UNSV LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete , all as specified and Make - C&G/ philips/ Bajaj/Havells make as approved by GE.
Supply and fixing in replacement of UNSV post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete,all as specified and as directed by as approved by GE.
Taking down ceiling fan, cable end, dismantling Ceiling fan, blades and re-fixing its in original position including painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete. Provision of 3 core PVC insulated sheathed 1100 volt grade flexible cable with stranded copper conductor of size not less than 0.5 sqmm and one make long from ceiling rose to ceiling fan all as approved by GE.
Taking down Exhaust fan, cable end, dismantling exhaust fan, blades and re-fixing its in original position after cleaning all the dust complete. Provision of 3 core PVC insulated sheathed 1100 volt grade flexible cable with stranded copper conductor of size not less than 0.5 sqmm and one meter long from ceiling rose to fan complete all as specified and as approved by GE.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 6.0 Sqmm, drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25mm dia with standard accessories along-with two run of PVC(green colour) insulated, FRLS-IS 694 cable unsheathed, multi stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed as approved by GE.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 4.0 Sqmm drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , FRLS-IS 694 cable unsheathed, multi stranded copper conductor of size 2.50 Sqmm as earth continuity conductor complete all as specified and directed as approved by GE.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 2.5 Sqmm, drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated ,FRLS-IS 694 cable unsheathed, multi stranded copper conductor of size 1.50 Sqmm as earth continuity conductor complete all as specified and directed as approved by GE.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sqmm, drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , FRLS-IS 694 cable unsheathed, multi stranded copper conductor of size 1.50 Sqmm as earth continuity conductor complete all as specified and directed as approved by GE. Notes for item No. 21 & 24: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
M&L in replacement UNSV of sub main wiring using four single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 10 Sqmm drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , FRLS-IS 694 cable unsheathed, multi stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed as approved by GE.
M&L in replacement UNSV of sub main wiring using four single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 6 Sqmm drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , FRLS-IS 694 cable unsheathed, multi stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed as approved by GE. Notes for Item 24 to 26 here in above : (i) Four run of single core PVC cable with two run of earth conductor and one run of conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
S&F in replecement of UNSV load line distribution board ,double door, 4 way, AC 3 Phase 415 volt with TPN bus bar 200 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheet,reversible door for IP 43-"IK 09 with metal door with provision for 100 MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed by Engr-in-Charge. Make of VTPN DB:-IndoAsian cat Part No-811893 or equivalent make in Havells/L& T.
S&F in replacement of UNSV MCB double door distribution board SPN, 240 volts, 8 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of BOQ Make: Legrand Cat Pt No. 4025 07 or equivalent in Havells/L&T/Schneider/ IndoAsian as approved by GE.
All as per item No 28 above but SPN, 240 volts, 12 ways. Make - Legrand cat ref no 4025 08 or make equivalent Havells/L&T/Schneider as approved by GE. Note for Item No.28 to 29.(i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing
Supply and fixed in replacement of UNSV MCCB 4 pole, 100 Amps 415 volts, 50 Hz having breaking capacity 16 KA , with adjustable thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian cat part No. 830334 or equivalent make in seimens / Schinder as approved by GE.
All as per item No 30 above but, MCCB 4 pole ,63 Amps Complete all as specified and directed. Make- IndoAsian cat part No. 830332 or equivalent make in seimens / Schinder/ IndoAsian as approved by GE .
S & F in replacement of unserviceable MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 40 amps complete all as specified and directed.Make - IndoAsian cat ref no 811152 or equivalent make in Hager or Schneider as approved by GE.
S & F in replacement of unserviceable MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811122/24/26/27/28/29 or equivalent make in Hager or Schneider as approved by GE.
S&F in replacement of UNSV 40 mm dia GI light grade pipe bracket 1.50 m long bent to shape by cutting & welding as required & directed and fixed to pole/wall with two No,s of FI clamps 40x5 mm to be tightened with bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make of pipe TATA / Jindal / Swastik / Prakash / BST approved by GE.
M & L for fabrication of Installation sign Board of size 1200 X 900 made out of 3 mm thick MS sheet and position the same on 50 X 50 X 6 mm Angle iron frame & fixing on 2 Nos posts made out of 40mm dia medium grade GI pipe up to 150 cm height ( 105 cm above the ground level and 45 cm below the ground level) with necessary fixing arrangements such as bolts, nuts and washers include of painting the sign board except GI posts with a coat of red oxide and two coats of synthetic enamel paint over the primer & pasting of retro refectative High intensity Grade (HIG) 3 mtr blue sheet over the PGI sheet with white 0.5 includ of border and weiting of information over board by cutting and pasting of letters, complete all as specified and Make of PGI Sheet : TATA/SAIL / TISCO of approved by GE. Note :- Meterial Information for pasting is approved by GE, all material and cutting ,pasting is deemed to be included in the rates quoted by tenderes the contractor in above respective item as approved by GE.
Dismantling and taking out old PVC flooring of any description and removing old unserviceable floowing of any type and M&L for supplying and fixing nominal 2.5 mm (+ 10% tolerance) thick electric insulated P.V.C. synthetic sheet viz “insulatica 2000” conforming to IS-15652 of 2006 alongwith suitable adhesive/chemibound, having leakage current tested to meet requirement of IS-8437, IS-3043, break-down strength 40 KV having no adverse impact of mineral oil, high insulation resistance including material for water proofing of floor and sealing of all joints as required, suitable for floor covering around electrical apparatus for voltage not exceeding 11 KV (AC) to ground complete all as specified and directed as approved by GE.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth wire 4.00 mm dia (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No . 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary excavation and earth work in any type of soil, and PCC (1: 3 : 6) type C-1 (using 20 mm graded black trap/ granite/ Basalt stone aggregate) for earth pit with 40x40x6 mm mild steel angle iron frame for cover and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1(using 20 mm graded black trap/granite/ basalt stone aggregate) with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle, complete all as specified & directed .
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead 32X 6 mm GI strip, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No . 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary excavation and earth work in any type of soil, and PCC (1: 3 : 6) type C-1 (using 20 mm graded black trap/ granite/ Basalt stone aggregate) for earth pit with 40x40x6 mm mild steel angle iron frame for cover and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1(using 20 mm graded black trap/granite/ basalt stone aggregate) with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle, complete all as specified & directed as approved by GE.
Disconnecting and taking down carefully old unserviceable GI strip of any type and size and Material and labour for laying along the wall/roof GI strip of size 32mm x 6mm complete with all accessories such as porcelain insulators, saddles and fixing screw etc for conductor complete, all as specified and directed as approved by GE.
Amit Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .