Tender Value
₹31.6 L
EMD Value
₹50,000
Closing Date
5 Oct 2020, 6:00 pmClosed
Manager Subcontract
KEL Kochi
ELECTRIFICATION WORK AT REGIONAL SCIENCE CENTRE CHALAKKUDY
2020_KEL_387613_1
KRO/ BDC/687/2020
Open Tender
Electrical Works
Item Rate
60 days
KEL Kochi
As per NIT
6 documents required · 6 mandatory
₹2,950
online
₹50,000
Yes
9 Oct 2020
25 Sept 2020
7 Oct 2020
25 Sept 2020
5 Oct 2020
25 Sept 2020
25 Sept 2020 - 5 Oct 2020
Amount
od120921/2020_2021 : Supply, installation, testing and commissioning of 11KV,630A, 20kA Motor operated, Compact, Outdoor, both side extensible, non draw out type, +CCV+ (2 No:s Load Break Switch (OD) incomer and 1 No: fixed type motor operated Vaccum Circuit Breaker (VL) outgoing compact gas insulated Ring Main Unit.All live parts enclosed in a robotically welded stainless steel tank of IP 67 class protection with battery and battery charger. This scope also includes obtaining necessary approvals from KSEB and Electrical Inspectorate. (*All Statutory fees should be remitted by the Consumer/Client or it should be reimbursed on the submission of supporting documents).
METERING PANEL
od36639/2020_2021 : Supply, installation, testing and commissioning of 11KV Outdoor Metering Panel with 3 No:s 11KV */5A CL 0.2S CT and 1 No: 3 Phase 11KV PT with provision for fixing TOD Meter including Test Terminal Block, Control Fuses along with weather proof IP-65 Outdoor Kiosk. This scope also includes the testing of CT, PT and obtaining test certificate from KSEB/TMR. *CT ratio will be furnished later and all Statutory fees should be remitted by the Client /Consumer or it should be reimbursed on the submission of supporting documents).
HT METER
od36642/2020_2021 : Supply, installation, testing and commissioning of CT, PT connected TOD Meter of approved brand and conforming to relevant IS and KSEB, Electrical Inspectorate regulations, IP 51 with unbreakable transparent cover, provision for sealing, anti tamper features, real time and calibrated quartz clock tested by KSEB. This scope also includes the testing of TOD Meter and obtaining test certificate from KSEB / TMR. (*All Statutory fees should be remitted by the Client / Consumer or it should be reimbursed on the submission of supporting documents).
TRANSFORMER
od36644/2020_2021 : Installation, testing and commissioning of 11KV/433V Three Phase Dry Type (CRT) 250KVA Transformer with 11KV, 350 MVA, 400A, 50Hz Load Break Switch fuse unit with shunt trip and earth switch conforming to Electrical Inspectorate and KSEB Standards.
DG SET
od36678/2020_2021 : Installation, Testing and Commissioning of 160 KVA, 3 Phase 415V, 0.8 power factor, comprising of diesel engine, fuel tank, alternator, base plate radiator, control panel with MCCB starting equipment exciter, home silencer and all necessary accessories etc. complete as required. (Including Acoustic Enclosure). This scope also includes the testing of Energy Meter, CTs, Relays etc and obtaining test certificate from KSEB / Electrical Inspectorate. (*All Statutory fees should be remitted by the Client / Consumer or it should be reimbursed on the submission of supporting documents).
MAIN SWITCH BOARD
od36682/2020_2021 : Supply, installation, testing & commissioning of CPRI approved cubical type Main Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalised design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 400 Amps capacity extensible type TPN Aluminium alloy bus bars of high conductivity, DMC / SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MSsection not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL.bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables, cable alleys etc. The panel should conform to the Electrical Inspectorate standards and it should only be manufactured after getting approval from the Electrical Inspectorate and the consultant.EB Side 1 No - 400A, 36kA 4P Microprocessor based MCCB set at 333A with 3 O/C and 1 E/F releases as Incomer, 1 Set RYB Indication lamps with Control MCBs, 3 Nos 400/5A CL:1, 10VA CT, 1 No. Digital Multifunction Meter measuring V,A,F,KW,KVA,PF with Control MCBs, 1 No. 400A 4P Power Contactor (AC3), 1 No Stand by Earth Fault RelayDG Side 1 No 250A 4P Isolator, 1 Set RYB Indication lamps with Control MCBs, 3 Nos 250/5A CL:1, 10VA CT, 1 No. Digital Multifunction Meter measuring V,A,F,KW,KVA,PF with Control MCBs, 1 No. 250A 4P Power Contactor (AC3), 1 Set Contactor with Mechanical and Electrical Inter-lockAMF AMF control suitable for control of 160 KVA DG set complete with AMF Relay with Control MCBs, Timer and all other necessary accessories.Outgoings 4 Nos - 250A 36kA 4P Microprocessor based MCCB with ROM and spreader, 4 Nos - 160A 36kA 4P Microprocessor based MCCB with ROM and spreader
APFC PANEL (60KVAR)
od36684/2020_2021 : Supply, installation, testing & commissioning of CPRI approved cubical type Automatic Power Factor Correction Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalised design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 2 dummy compartments for future capacitor addition, 200 Amps capacity type TPN Aluminium alloy bus bars of high conductivity, DMC / SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 3 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen )copper conductor cables, cable alleys etc. The panel shouldconform to the Electrical Inspectorate standards and it should only be manufactured after getting approval from the Electrical Inspectorate and the consultant. 1 No - 200A TPN Isolator as Incomer, 1 Set RYB Indication lamps with Control MCBs, 3 Nos 200/5A CL:1, 10VA CT, 1 No. Digital Multifunction Meter measuring V,A,F,KW,KVA,PF with Control MCBs, 1 No - Micro processor based APFC Relay1 Nos. - 40A TP MCB, 1 Nos. - 40A TP MCB with Capacitor Duty Contactor, 2 Nos. - 32A TP MCB with Capacitor Duty Contactor, 2 Nos. - 20A TP MCB with Capacitor Duty Contactor, 2 Nos. - 15 kVAr Heavy Duty Cylindrical Capacitor, 2 Nos. - 10 kVAr Heavy Duty Cylindrical Capacitor, 2 Nos. - 5 kVAr Heavy Duty Cylindrical Capacitor, 6 Nos. - On off Push Button with Indicator.
SUB SWITCH BOARD
od36689/2020_2021 : Supply, installation, testing & commissioning of CPRI approved cubical type Sub Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalised design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 200 Amps capacity type TPN Aluminium alloy bus bars of high conductivity, DMC / SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 3 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables cable alleys etc. The panel should conform to the Electrical Inspectorate standards and it should only be manufactured after getting approval from the Electrical Inspectorate and the consultant. 1 No - 200A TPN Isolator as Incomer, 1 Set RYB Indication lamps with Control MCBs, 3 Nos 200/5A CL:1, 10VA CT, 1 No. Digital Multifunction Meter measuring V,A,F,KW, KVA,PF with Control MCBs, 2 Nos - 100A 25kA TP Thermal Magnetic MCCB having 70 to 100% setting provision with ROM and spreader, 3 Nos - 80A 25kA TP Thermal Magnetic MCCB having 70 to 100% setting provision with ROM and spreader, 1 Nos - 63A 25kA TP Thermal Magnetic MCCB having 70 to 100% setting provision with ROM and spreader.
NEUTRAL CT WITH ENCLOSURE
od36694/2020_2021 : Supply and installation of 80/5 Resin cast class 5P10 10VA Neutral CT with bar primary 25 x 6mm copper in a suitable powder enclosure box with necessary wiring and earthing of the box.
DISTRIBUTION BOARD
od36828/2020_2021 : Supply and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder coated, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (But without MCBs and incomer) as required.6 Way (8 + 18), Double Door
od36830/2020_2021 : Supply and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder coated, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (But without MCBs (But without MCBs and incomer) as required.6 Way , Double Door
od36831/2020_2021 : Supply and fixing following rating and breaking capacity and pole MCCB with thermal magnetic release having 70 to 100% setting provision and terminal spreaders in existing cubicle panel board or distribution board including drilling holes, making connections, etc. as required.100A 25kA TP MCCB
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
od122874/2020_2021 : Supply and fixing following rating, four pole, (three phase and neutral), 415V, Residual Current Circuit Breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A 100mA
od122877/2020_2021 : Supply and fixing following rating, four pole, (three phase and neutral), 415V, Residual Current Circuit Breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A 100mA
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
od122878/2020_2021 : Supply and fixing 40A to 63A rating, 240/415V, 10kA, "C " Curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.40A to 63A Triple Pole
MCB DUMMY
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
ISOLATOR
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
WEATHER PROOF ENCLOSURE
od74966/2020_2021 : Supply, installation, testing, and commissioning of IP65 thermoplastic fire retardant and weather proof box for Air Conditioning units having provision for fixing 4 pole isolator and glanding cables.
METAL ENCLOSURE
od74969/2020_2021 : Supply and fixing Sheet steel enclosure on surface/recess having provisions to fix MCB/Isolator complete with connections,testing and commissioning etc. as required.4 Way
EMERGENCY PUSH BUTTON
od74983/2020_2021 : Supply, installation, testing and commission of Emergency Stop Push Button with enclosure for the Transformer.
HT CABLES
od75034/2020_2021 : Supply, laying, testing and commissioning of 11 KV grade XLPE insulated armoured cables of the following size and laying in earth excavated trenches, clamping in built up trenches, trays using heavy duty Aluminium or GI Flat or by using heavy duty GI spacer saddles and on 11 KV pole structure using necessary heavy duty GI supports and clamps of which spacing of clamps not exceeding 50cm and pulling through pipes etc including all minor civil works.3C x 300 sq.mm
od75469/2020_2021 : Supply, laying, testing and commissioning of 11 KV grade XLPE insulated armoured cables of the following size and laying in earth excavated trenches, clamping in built up trenches, trays using heavy duty Aluminium or GI Flat or by using heavy duty GI spacer saddles and on 11 KV pole structure using necessary heavy duty GI supports and clamps of which spacing of clamps not exceeding 50cm and pulling through pipes etc including all minor civil works.3C x 240 sq mm
od120949/2020_2021 : Supply, laying, testing and commissioning of 11 KV grade XLPE insulated armoured cables of the following size and laying in earth excavated trenches, clamping in built up trenches, trays using heavy duty Aluminium or GI Flat or by using heavy duty GI spacer saddles and on 11 KV pole structure using necessary heavy duty GI supports and clamps of which spacing of clamps not exceeding 50cm and pulling through pipes etc including all minor civil works.3C x 185 sq mm
L T CABLES
od75475/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses, walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.3.5C x 185 sq mm Al. cable
od75484/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.3.5C x 150 sq mm Al. cable
od75488/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.3.5C x 70 sq mm Al. cable
od75490/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.3.5C x 50 sq mm Al. cable
od75522/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.3.5C x 35 sq mm Al. cable
od75525/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.4C x 25 sq mm Al. cable
od75526/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.4C x 16 sq mm Al. cable
od75531/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.4C x 2.5 sq mm Copper Armoured Cable
od75533/2020_2021 : Supply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm and pulling through pipes including all minor civil works.2C x 2.5 sq mm Copper Armoured Cable
GLANDING AND TERMINATION
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
od120961/2020_2021 : Supply and making end termination with brass compression gland and alluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE Aluminium conductor cable of 1.1 KV grade as required.4C x 2.5 Sq.mm copper armoured cable
od120962/2020_2021 : Supply and making end termination with brass compression gland and alluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE Aluminium conductor cable of 1.1 KV grade as required.2C x 2.5sq.mm Copper Armoured cable
HT END TERMINATION
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.4.3 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:240 sq. mm
od120990/2020_2021 : Supply and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.185 sq. mm
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
10.5.3 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 sq. mm
od120991/2020_2021 : Supply and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs, additional sleeves etc suitable for following size of 3 core, XLPE Aluminium conductor cable of 11KV grade as required.185 sq mm
PLATE EARTHING
od124016/2020_2021 : Supply and providing earthing with CI earth plate 1200mm x 1200mm x 12.6mm thick electrode including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required conforming to relevant IS and Electrical Inspectorate standards etc.
od124017/2020_2021 : Supply and providing earthing with CI earth plate 600mm x 600mm x 6mm thick electrode including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required conforming to relevant IS and Electrical Inspectorate standards etc.
EARTHING CONDUCTORS
od120994/2020_2021 : Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 90cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required.<br>25 x 6 mm Copper Strip
od120995/2020_2021 : Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 90cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required.<br>25 x 3 mm Copper Strip
od120996/2020_2021 : Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 90cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required.<br>10 SWG Copper Wire
od124090/2020_2021 : Supply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 90cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required.<br>8 SWG Copper Wire
MS STRUCTURALS
od120997/2020_2021 : Supply, fabrication and installation of cable tray and supports using M.S angles and plates of adequate size painted with one coat of Zinc chromate primer and two coats of black enamel paint.
od120998/2020_2021 : Supply, fabrication and installation of Transformer, Panel Board mounting supports using C Channels of adequate size painted with one coat of Zinc chromate primer and two coats of black enamel paint.
od120999/2020_2021 : Supply, fabrication and installation of checkered plates of 6mm thickness to use above the cable trenches duly supported with channels and duly painted with one coat of Zinc chromate primer and two coats of black enamel paint.and as required.
GI CABLE TRAY
od121056/2020_2021 : Supply and installing following size of Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns), in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts and nuts, etc. as required.<br>450mm width
od121113/2020_2021 : Supply and installing following size of Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns), in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts and nuts, etc. as required.<br>300mm width
CABLE ROUTE MARKER
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.
PIPES FOR CABLE PROTECTION
14.15.1 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
14.15.2 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)
14.15.3 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)
14.15.4 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal)
14.15.5 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal
DG EXHAUST PIPING
od121117/2020_2021 : Supply and laying of 100mm dia exhaust line with flexible including bends, flanges, nut, bolt, packing, necessary supports etc and painting the same using Heat resistant Aluminum paints.
od121118/2020_2021 : Supply and laying of 150mm dia exhaust line with flexible including bends, flanges, nut, bolt, packing, necessary supports etc and painting the same using Heat resistant Aluminum paints.
od121119/2020_2021 : Providing thermal insulation of exhaust line glass wool with Al. Sheet, chicken mesh, necessary supports and screws.
POINT WIRING
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
CIRCUIT WIRING
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
SUPPLY AND LAYING OF CONDUITS
od121120/2020_2021 : Supply and fixing of following sizes of heavy class PVC conduit along with accessories in roof slab, jointing with PVC solvent cement, tying and fixing the conduit firmly with the reinforcement etc. as required.<br>20mm
od121121/2020_2021 : Supply and fixing of following sizes of heavy class PVC conduit along with accessories in roof slab, jointing with PVC solvent cement, tying and fixing the conduit firmly with the reinforcement etc. as required.<br>25mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
SUPPLY OF LIGHT AND OTHER ITEMS
od121123/2020_2021 : Supply and providing the following fittings and items at site.Battern/Angle Holder
od121124/2020_2021 : Supply and providing the following fittings and items at site.<br>LED Bulb (up to 12W)
od121125/2020_2021 : Supply and providing the following fittings and items at site.<br>Industrial type Tube Set of 24W
od121126/2020_2021 : Supply and providing the following fittings and items at site.<br>Ceiling Fan of Sweep 1200mm
od121127/2020_2021 : Supply and providing the following fittings and items at site.<br>Exhaust Fan of Sweep 225mm
INSTALLATION OF LIGHT AND OTHER FIXTURES
od122808/2020_2021 : Installation, testing and commissioning of PVC battern/angle holder fitting complete with all accessories directly on ceiling/wall, including giving connections etc. as required.
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
SAFETY EQUIPMENTS
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
od122811/2020_2021 : Supply and fixing 2Kg Dry Chemical Powder (DCP) type fire extinguisher complete with Gun Metal cap, hose with squeeze grip nozzle, wall fixing brackets conforming to BIS: 2171 and with ISI mark.
od122812/2020_2021 : Supply and fixing safety instruction chart in word duly framed in good frame work as required.
od122813/2020_2021 : Supply and providing a set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint "FIRE" and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.
od122814/2020_2021 : Supply and providing First Aid Box as approved by St.John Ambulance Brigade / Indian Red Cross conforming to IS 2217 : 1963.
od122816/2020_2021 : Supply and fixing laminated shock treatment chart duly mounted on a good frame work.
od122817/2020_2021 : Supply and providing electrical grade rubber mat of size 2m x 1m having 12mm thickness in front of panels and DBs conforming to IS 15652 : 2006 standard.
od122818/2020_2021 : Supply and providing electrical grade rubber mat of size 2m x 1m having 6mm thickness in front of panels and DBs conforming to IS 15652 : 2006 standard.
od122819/2020_2021 : Supply and providing 1 pair of 11KV tested rubber gloves conforming to IS 4770 : 1991.
od122821/2020_2021 : Supply and providing 11KV tested discharge rod conforming to IEC 61230.
od122822/2020_2021 : Supply and providing tested industrial safety helmet conforming to IS 2925 : 1984.
NAMING FOR IDENTIFICATION
od122823/2020_2021 : Painting letters or figures of 2.5cm/4.5cm sizes with enamel paint as identification mark to Panel boards, DBs etc as required.
EARTH EXCAVATION AND BACK FILLING
od122824/2020_2021 : Excavation of all types of soils for the laying of XLPE insulated power cable (up to 5 No:s) to the required width and depth up to 1.2m and back filling after providing sand cushioning and protective covering by laying bricks breadth wise above the cable. The supply of sand and bricks will come within this scope. The trench dimensions and specifications should be as per the Electrical Inspectorate, KSEB & CPWD standards.
DOCUMENTATION
od124012/2020_2021 : Taking soil resistivity at site and obtaining test certificate from Electrical Inspectorate (*All Statutory fees should be remitted by the Client / Consumer or it should be reimbursed on the submission of supporting documents).
od124013/2020_2021 : Preparation of complete Electrical scheme and drawing for getting approval from Electrical Inspectorate. (*All Statutory fees should be remitted by the Client / Consumer or it should be reimbursed on the submission of supporting documents).
od124014/2020_2021 : Submission of completion report, arranging Inspection and obtaining Sanction Order from Electrical Inspectorate .(All Statutory fees should be remitted by the Client / Consumer or it should be reimbursed on the submission of supporting documents).
od124015/2020_2021 : Co-ordination with KSEB getting power allocation by submission of 7 sets of HT agreement and executing the agreement etc.(All Statutory fees should be remitted by the Client / Consumer or it should be reimbursed on the submission of supporting documents).
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
Push Button- L&T, Schneider, Rishabh
Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Detailed list of Approved brands/ make enclosed.
Rupees Thirty one lakh fifty seven thouand seven hundred and eighty only(GST Exclusive @ 18%)
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per Electrical Inspectorate / KSEB specification and direction of Engineer at site.
ELECTROWIND ENGINEERING CO
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .