Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC KRISHNAKRIPA KOTTARAKARA | L1 | Accepted-AOC accepted |
| Sl No | Description | Qty | Unit | K K Associates L1 |
|---|---|---|---|---|
| 1.00Electrification | ||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 9 | point | 1,200 ₹10,800 Lowest |
| 1.00 | OD18980/2025-2026:Supply and fixing LED bulk head fitting having power consumption not more than 10W and light output less than 1100 Lumens with system efficacy greater than110 Lumen/Watt with premium quality diffuser for even distribution of light to wall/ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required. | 5 | each | 1,000 ₹5,000 Lowest |
| 1.00 | OD18762/2025-2026:Supply, installation, testing and commissioning of 3 Meter decorative pole made out of hot dipped Galvanized Iron (tubular pole), T- washed and primed (ASTM A123, with minimum average Zinc coating thickness of 65μm), having two sections (bottom section of minimum 1000mm length (L) x 114mm outer diameter (D) and the top section with minimum of 2000mm length (L) x 76mm outer diameter (D)). Design comply with BS EN40 standard and basic wind speed 169kmph. The Embellishments are cast in iron and fitted to the column by grubs screw fitting. The embellishments shall be sealed to the column. The Pole Base plate should be with 250x250x14 mm. The column shall also be provided with flush door at the bottom with proper strengthening to the cut-out of the door opening. The Pole Shaft/pipe should be fabricated out of Steel tube of grade YST 210/240. The pole shaft and base plate shall be hot dip galvanized (7stage process) as per IS 2629 having minimum average DFT of 65 microns before the coating of high quality epoxy zinc rich primer. The complete pole should be treated with high quality epoxy zinc rich primer and thereafter coated with Polyurethane paint (marine grade) of minimum average DFT of 100 microns (Total pole thickness 165 micron). The pole shall have in built junction looping box at bottom section with 32 A heavy duty 4-way connector for loop in and loop out and provision for MCB. The pole shall be of composite construction designed to wind load corresponding to a basic wind speed of 169kmph without any deformation or damage to the structure.
Make: KESSSLEC 3M BLENHEIM POLE PU PAINTED (MARINE GRADE) WITH HDGI BASEPLATE and four number(4Nos)16mm dia, 450mm long EN8 Grade Anchor bolt or its equivalent
. | 18 | each | 23,000 ₹4,14,000 Lowest |
| 1.00 | OD18759/2025-2026:Supply Installation, Testing and Commissioning of post top luminaire with the following specification.
1. Nominal Voltage- 240VAC, 2. Power Factor- >=0.95, 3. Colour Temp.(CCT)- 4000-5700K, 4. Color Rendering Index (CRI)-70 to 80, 5. IP66/IP65 and IK07/IK08 protection against water and impact, 6. THD <=10%, 7. Average life of 50000 hours, 8. Minimum efficiency of 100lm per watt, 9. Short circuit, Open circuit, Over Voltage protection, Surge Voltage protection and other safety test as per IS 15885 Part-2/Sec 13, 10. Aluminium housing, 11. Inbuilt driver, 12. Make- Philips Uniscape BGP200 LED35 CW PSU GR CPC SPD or its equivalent. | 18 | each | 9,400 ₹1,69,200 Lowest |
| 1.00 | 90.4.3:Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required. | 4 | each | 235 ₹940 Lowest |
| 1.01 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | 4 | each | 2,200 ₹8,800 Lowest |
| 1.01 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 30 | metre | 65 ₹1,950 Lowest |
| 1.01 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 10 | metre | 90 ₹900 Lowest |
| 1.01 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | 3 | metre | 140 ₹420 Lowest |
Tender Value
₹8.5 L
EMD Value
₹21,178
Closing Date
13 Jun 2025, 4:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer P.W.D Electrical Sub Division Kollam
LAC-ADS-2024-25, Sri.G.S Jayalal M.L.A, Chathannoor LAC-Renovation of Vayalikada Pond in Chathannoor Grama Panchayathu-General Electrical Work
2025_PWD_765716_2
PWD/BLDG/EST/7713/2025
Open Tender
Electrical Works
Item Wise
365 days
Vayalikkada pond chathannoor LAC
Please refer tender document
9 documents required · 9 mandatory
₹1,870
₹21,178
22 Aug 2025
6 Jun 2025
16 Jun 2025
6 Jun 2025
13 Jun 2025
6 Jun 2025
Amount
Electrification
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD18980/2025-2026:Supply and fixing LED bulk head fitting having power consumption not more than 10W and light output less than 1100 Lumens with system efficacy greater than110 Lumen/Watt with premium quality diffuser for even distribution of light to wall/ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
OD18762/2025-2026:Supply, installation, testing and commissioning of 3 Meter decorative pole made out of hot dipped Galvanized Iron (tubular pole), T- washed and primed (ASTM A123, with minimum average Zinc coating thickness of 65μm), having two sections (bottom section of minimum 1000mm length (L) x 114mm outer diameter (D) and the top section with minimum of 2000mm length (L) x 76mm outer diameter (D)). Design comply with BS EN40 standard and basic wind speed 169kmph. The Embellishments are cast in iron and fitted to the column by grubs screw fitting. The embellishments shall be sealed to the column. The Pole Base plate should be with 250x250x14 mm. The column shall also be provided with flush door at the bottom with proper strengthening to the cut-out of the door opening. The Pole Shaft/pipe should be fabricated out of Steel tube of grade YST 210/240. The pole shaft and base plate shall be hot dip galvanized (7stage process) as per IS 2629 having minimum average DFT of 65 microns before the coating of high quality epoxy zinc rich primer. The complete pole should be treated with high quality epoxy zinc rich primer and thereafter coated with Polyurethane paint (marine grade) of minimum average DFT of 100 microns (Total pole thickness 165 micron). The pole shall have in built junction looping box at bottom section with 32 A heavy duty 4-way connector for loop in and loop out and provision for MCB. The pole shall be of composite construction designed to wind load corresponding to a basic wind speed of 169kmph without any deformation or damage to the structure. Make: KESSSLEC 3M BLENHEIM POLE PU PAINTED (MARINE GRADE) WITH HDGI BASEPLATE and four number(4Nos)16mm dia, 450mm long EN8 Grade Anchor bolt or its equivalent .
OD18759/2025-2026:Supply Installation, Testing and Commissioning of post top luminaire with the following specification. 1. Nominal Voltage- 240VAC, 2. Power Factor- >=0.95, 3. Colour Temp.(CCT)- 4000-5700K, 4. Color Rendering Index (CRI)-70 to 80, 5. IP66/IP65 and IK07/IK08 protection against water and impact, 6. THD <=10%, 7. Average life of 50000 hours, 8. Minimum efficiency of 100lm per watt, 9. Short circuit, Open circuit, Over Voltage protection, Surge Voltage protection and other safety test as per IS 15885 Part-2/Sec 13, 10. Aluminium housing, 11. Inbuilt driver, 12. Make- Philips Uniscape BGP200 LED35 CW PSU GR CPC SPD or its equivalent.
90.4.3:Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
OD18768/2025-2026:Supplying and fixing 32 A, 3 pole power Contactors, AC 3 rating at 415 V, with AC Coil, Auxiliary contacts in the existing DB/panel complete with connections, testing and commissioning etc. as required.
OD18770/2025-2026:Supplying ,installation, testing and commissioning of 16A, 250VAC, 50/60Hz, 24Hr Timer switch with 3-position override switch "ON-AUTO-OFF" on front panel, conforming to IEC 60730-1/IEC 60730-2-7 in the existing DB/panel complete with connections etc. as required.
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD18988/2025-2026:Supply and installation of DIN rail mounted feed through terminals polyamide 6-6, Current rating 100A and wire size up to 25 Sq.mm in existing junction box and giving connection as required.(Elmex KUT 25 or equivalent)
90.12.1.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD18983/2025-2026:Supply & installation of dust and vermin proof, wall mounting, Sintex box of size 200x140x95mm hinged door construction for the front side with knock out for cable entry and exit.(GSJB-2014).
OD18967/2025-2026:Supply & installation of dust and vermin proof, wall mounting, Sintex meter box of size 430x215x150/120mm suitable for fixing KSEB meter,fuse units etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit(GSMB-4422) including 32A DP MCB, 32A cutout, N/L etc.
OD18968/2025-2026:Amount to be deposited with K.S.E.B for Meter testing/Availing service connection/Additional Load/Meter Shifting.(Actual amount will be reimbursed on production of original documents)
Under ground pipe laying
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Bidder Name
K K Associates
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .