Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹20.9 L+₹2.7 L (14.8%)Rejected-Finance 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | L3₹22.0 L+₹3.8 L (20.6%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 4 | L4₹23.6 L+₹5.4 L (29.4%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹23.8 L
EMD Value
₹47,500
Closing Date
16 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
PROVISION OF DEFICIENT VOLLEY BALL COURT AT INS DRONACHARYA
2022_MES_541881_1
8834/E8/GE_FORT_KOCHI
Open Tender
Construction Works
Item Rate
180 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE FORT KOCHI
₹47,500
Yes
29 Oct 2022
17 Aug 2022
19 Sept 2022
17 Aug 2022
16 Sept 2022
2 Sept 2022
Amount
Excavating over areas, n exc 1.5 m deep and getting out in soft and loose soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq. m on plan and n exc 1.5 m in depth and getting out in soft and loose soil complete all as specified and as directed.
Returning, filling in, soils including spreading, levelling, watering and well ramming in layers not exc 25 cm etc. complete all as specified and as directed.
M&L Removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete all as specified and as directed.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc. complete all as specified and as directed.
M&L for treating the top surface with anti-termite treatement of filled earth @5 Ltrs of emulsion per sqm of surface by making 30mm deep hole at 30cm spacing complete all as specified and as directed.
Hardcore of broken stone or boulders of gauge n exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface etc. complete all as specified and as directed.
M&L for 150mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring, hardstanding etc; finished even and fair including necessary formwork etc; complete all as specified and as directed.
M&L for Plain Cement Concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, filing and mass concrete including necessary formwork complete all as specified and as directed.
M&L for Plain Cement Concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation, filing and mass concrete for post and referee stand including necessary formwork complete all as specified and as directed.
M& L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in CM 1:6 type C1 1:3:6 (20 mm graded stone aggregate) etc complete all as specified and as directed.
S&F for MS round pipe for volley ball post including pulley,hook,cutting tops to shape including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 fixed in cement concrete foundation etc; complete all as specified and as directed.
S & F for Framed work such as referee stand, etc.with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming Fe.290.Gde-E-165 etc. complete all as specified and as directed.
S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe 410-W (Gde- E- 250) quality- A complete all as specified and as directed.
M & L for preparation of new steel surface over 10 cm width or girth and applying two coats of VX polymer based anti corrosive paint over a coat of anti corrosive primer etc; complete all as specified and as directed.
M & L for cement concrete type B1 1:2:4 (20 mm graded aggregate) as in foundations of post and mass concrete etc. including necessary formwork complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire etc. complete all as specified and as directed.
Supply only 3.16 mm dia galvanised coated Chain link fencing 100 mm x 100 mm, any size or type etc. complete all as specified and as directed. NOTE : Weight of chain link fencing will be assessed by a BOO.
Supply only deformed bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. complete all as specified and as directed.
S & F for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for precast reinforced cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in landings, shelves, cover slabs (manholes etc) and similar articles with plain faces, set in cement mortar 1:4 with and including necessary form work complete all as specified & as directed by Engineer-in-charge.
M&L plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregates coping including necessary form work complete all as specified and as directed.
S&F mild steel TMT bars 10mm dia and over cut to length, bend to shape required including cranking, bending spirally or hooping for column, hooking ends ad binding with mild steel wire annealed not less than 0.9mm dia etc. complete all as specified and as directed.
S&F mild steel TMT bars 6mm to 8mm dia cut to length, bend to shape required including cranking, bending spirally or hooping for column, hooking ends ad binding with mild steel wire annealed not less than 0.9mm dia etc. complete all as specified and as directed.
Material and labour for 12mm thick rendering cement plaster in cement and sand mortar 1:4 over brick or concrete surfaces finished fair and even complete all as specified and as directed.
Extra for forming fair finished drain or channel 65 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
M&L XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having 25 Sq.mm 3.5core sectional area 1100 volt grade , heavy grade conforming to IS :7098 (Part 1) laid in trenches or ducts or passing through pipes or fixing on poles etc complete all as specified and as directed. Note : Necessary earth works, sand cushioning, cable protection cover, gi pipe etc will be measured and paid separately under relevent items.
Supply , fill and spread locally available riddle sand, compacting for sand cushioning of under ground cable all as specified and as directed. Note: Punned thickness shall only be measured for payment.
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and as directed.
S&F Prestressed concrete pole 9.0 metres long, 102x152mm at top and 102x289mm at bottom, class 10 complete all as specified and as directed.
S&F flood light fitting 50 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Make: Bajaj Cat Part No: BJFL 50W LED I or equivalent make in Appendix 'C'
Supply and fixing SMC junction box size of 300x200x105 mm fixed on pole including provn of MCB TPN 20 Amps fixed on rail inside box with proper hinges locking arrangements with provn of clamping accessories complete all as specified and as directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and as directed.
M&L for factory made and outdoor type powder coated CRCA sheet 1.6 mm thick suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system with prov of programmable timer switch for street lights (digital timer setting with monsoon/summer/winter etc) with three phase contactor 20 amps , 10 amps MCB TPN complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .