Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.0 L+₹12,433 (1.58%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹8.3 L+₹36,993 (4.69%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹10.3 L+₹2.4 L (30.6%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
₹8.1 L
EMD Value
₹17,000
Closing Date
28 Sept 2022, 10:00 amClosed
Executive Engineer
Elect. Division HPPWD Palampur
Rewiring and replacement of old fixtures with LEDs to the HP PWD Rest House at Shahpur in Tehsil Shahpur Distt. Kangra (HP)
2022_PWD_65278_1
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
180 days
Shahpur in Distt. Kangra
Please refer Tender documents.
9 documents required · 9 mandatory
₹350
₹17,000
11 Mar 2023
21 Sept 2022
28 Sept 2022
21 Sept 2022
28 Sept 2022
21 Sept 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, (But without modular switch, modular plate, suitable GI box) and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (But without modular switch, modular plate, suitable GI box)
Group-C
Makes:- KEI/Anchor/Plaza /SCI
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Makes:- KEI/Anchor/Plaza /SCI
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 Way, Double door
Makes:- Anchor/Legrand/Schneider
Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6-32 Amp., Single pole
Makes:- L&T/Legrand/Schneider
Supplying and fixing 40/50/63 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amp., Double pole
Makes:- L&T/Legrand/Schneider
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
RCCB DP 63 Amp.
Makes:- L&T/Legrand/Schneider
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
S.P. 5/6 amps, one way modular switch
S.P. 15/16 amps, one way modular
3 pin 5/6 amps modular socket outlet
6 pin 15/16 amps modular socket outlet
Modular bell push, ISI marked
Makes:- L&T/Legrand/Schneider
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
2 Module
4 Module
6 Module
12 Module
Makes:- L&T/Legrand/Schneider
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
MCCB 100 A 16/18 KA
MCCB 250 A 25 KA
Makes:- L&T/Legrand/Schneider
Supplying and fixing of following ways surface/ recess mounting, 415 volts TPN SMDBs for Power Distribution made of sheet steel, dust protected, duly powder painted with provision of Metering, Bottom Cabling Box, (but without incoming and outgoing MCCBs) complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachable gland plate, cable interconnections, including earthing etc. as required:- (Note: TPN SMDBs are is normally used for 3 phase Sub-distribution outlets only)
SMDB - TN250D, O/G 100A 4 ways
Makes:- L&T/Legrand/Havells
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision to mount 4 Pole MCCB incomer, 2 module sub-incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required.
Tier PPI DB 12 Way with MCCB Incomer
Makes: L&T (Cat. No. DBTPL012DD)/Legrand/Schneider
Providing and installation of LED fixture 18W +/- 1W LED round/square recess mounted downlighter with minimum system lumen efficacy of 85 lm/W with and P.F. >0.95 with THD <20%, CCT 6000K, CRI 80. The LED with useful life of 50000 Hrs. at L70. The input voltage range shall be 150V as required complete with connections, testing etc.
18 Watt LED round recess
Makes:-Wipro/Havells/Panasonic
Providing and fixing decorative extruded tube fixture having high quality design suitable for LED tube up to 18Watt (1800 lumen) 6500K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, including one no. tube rod 18 Watt complete with all accessories, connections, testing and commissioning etc. as required. complete in all respects.
18 Watt LED Tube fixture
Makes:-Wipro/Bajaj/Havells
Supplying, fixing, testing and commissioning of bell indicator device with in-built display indicator panel, built in speakers hand module for call bell push button suitable for following nos. of ways/switches as required complete in all respects.
Calling bell indicator system with 24 points
Makes:- Anchor/Legrand/Schneider
Providing and installation of LED fixture 600mm x 600mm 36W +/- 1W surface mounted with PMMA diffuser with having minimum system lumen efficacy of 100 lm/W with and P.F. >0.95 with THD <10%, CCT 5700K, CRI 80. The LED shall be tested with LM80-08 standard with useful life of 50000 Hrs. at L70 as required complete in all respects.
36 Watt Surface LED Panel 2'x2'
Makes:- Wipro/Trilux/Philips
Sourab Kuthiala
M/s Jamwal nxt gen energy solutions
pankaj saini
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .