Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-Finance 5TH FLOOR DP 9 P T I BLDG SALT LAKE SALT LAKE KOLKATA WEST BENGAL 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | ₹24.3 L | L1 | Accepted-Finance Qualified the financial bid evaluation |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
21 Apr 2025, 5:15 pmClosed
Managing Director
KTDC Corporate office Mascot Square Thiruvananthapuram
Supply, installation,testing and commissioning of 10 passenger elevator at KTDC Corporatr Office Thiruvananthapuram
2025_KTDC_752049_1
AE(E)I/KTDC/1335/HO/Lift/2024
Open Tender
Electrical Works
Item Rate
90 days
KTDC Corporate Office Thiruvananthapuram
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,950
₹50,000
26 Apr 2025
8 Apr 2025
23 Apr 2025
8 Apr 2025
21 Apr 2025
8 Apr 2025
Amount
SITC OF ELEVATOR SYSTEM
Supply, Installation, Testing & Commissioning of 680 kg (10 Passenger), five stop ( five floor ), five opening, double door, 1.0 m/s, V3f Microprocessor controller based drive, Machine Room ,Half framed glass door with one hour fire rated and SS silver brushed finish car with all modern features including suitable LED down lights, ventilation fan, LED backlight control buttons, digital car position indicator, multi ray electronic door detection systems,Elevator announcement system etc., operating at 3 phase 415V, 50Hz AC supply with suitable counter weight mechanism, guide rails & gearless type motor .etc suiting to manufactures technical specifications & standards. (Suiting to well size - 2060mm w x 2060mm) (Car size- 1350mm w x 1300mm D x 2200mm H)
ARD SYSTEM
Supply & providing suitable ARD System for the above lift with standard dust & vermin proof ARD panel including all necessary control wiring, adequate capacity SMF batteries etc. to attend during sudden power failure
ELECTRICAL WORKS
Charges for the preparation of scheme drawings, laison work with Electrical Inspectorate and obtaining scheme approval and energisation sanction including all other incidental expenses and required remittance etc complete.
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 20 mm
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 5 x 4 sq. mm
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP42/43)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Buy back of existing1 no of 10 passenger GLS with Machine room Elevator,ARD System with existing lift panel and Micro processor etc. complete. (Infra Elevators)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .