Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹41.0 L+₹7,103.50 (0.17%)Rejected-Finance | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹41.9 L+₹97,733.35 (2.39%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹42.2 L+₹1.3 L (3.23%)Rejected-Finance 33 A DURGA NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹44.8 L+₹3.9 L (9.55%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
21 Jun 2022, 6:00 pmClosed
GE(NORTH) AMBALA CANTT
GE(NORTH) AMBALA CANTT
CA NO GE(N)AMB-17/2022-23 SPECIAL REPAIR TO BUILDING NO. HT-12 AND PROVISION OF TWO TOILETS AND BATHROOM BLOCKS FOR ORS IN THE CAMP OF HQ PH AND HP (I) SUB AREA UNDER GE (NORTH) AMBALA CANTT
2022_MES_526431_1
GE(N)Amb-17/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE(NORTH) AMBALA CANTT
As per tender documents
9 documents required · 9 mandatory
₹500
GE(NORTH) AMBALA CANTT
₹96,000
Yes
12 Jul 2022
26 May 2022
23 Jun 2022
26 May 2022
21 Jun 2022
9 Jun 2022
26 May 2022 - 9 Jun 2022
Amount
Schedule 'A' Part-I (B/R itmes) Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing of excavated material to a distance not exc 50 m and depositing at a level not exc 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC M-25 (design mix) using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (design Mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in pillars, posts,struts, piers, columns and stanchions complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 CM thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and as directed by the Engineer-in-Charge.
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
Formwork to sides of pillars, posts,struts, piers, columns and stanchions flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 6mm dia and over up to and including 10mm dia in stirrups, spacers etc, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for brick work with sub class B bricks old size bricks, straight or curved on plan any radius in cement mortar (1:4), for half brick thick wall complete all as specified.
M&L rendering 05 mm thick on fair faces of brick work or concrete ceiling or chajjas surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:4 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 250mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing new plastered/unplastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on surfaces of walls, chajjas, roof projection complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller over and including a coat of alkali resistant primer complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc 63mm , deposited , spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:4:8 Type D-2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L Non Skid coloured ceramic tiles joint free premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L Non Skid coloured ceramic tiles joint free premium/1st quality of same description as of floor tiles in serial item No 27 above but 150mm height as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free premium/1st quality in vertical surfaces/skirtings/dados of size 300x600 x7mm/ 450x 300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
S&F box type using ERW hollow 'P' section ventilators glazed/gauged including MS grills of square bar 10mm dia @ 100 c/c complete with glazing bars dovetailed or welded, including two coat of synthetic enamel ordinary tint paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
S&F galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.0mm thick ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel butt hinges 100mm long medium weight complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, PVC waste pipe , providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest, PVC (SWR) P or S trap having pressure rating 6 Kg per sqcm complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases into brick wall ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore fancy type cast copper alloy chromium plated stop valves with long shank and cup (concealed type), screwed down, high pressure with crutch handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy angular type chromium plated stop valves, screwed down, high pressure with capstan head screwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated capstan head with long body screwed down for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated toilet paper holder complete fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm wide with chromiun plated brackets guard and railing 60 cm long complete all as specified and as direced by the Engineer-in-charge.
S & F as in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore brass chromium plated WHB/Sink mixer swan neck type long shank & fly nut for mixing hot & cold water, screwed down, high pressure, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge
S&F Brass chromium plated shower rose 125mm size swivel type with arm of standard size as per site complete all as specified and as direced by the Engineer-in-charge.
S & F brass chromium plated corner Glass slelf set of three (with bracket) including fixing with brass screws to wall complete fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F brass CP Towel ring round between flanges including fixing with brass screws complete fixed complete all as specified and as directed by the Engineer-in-Charge.
M & L 75mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
S & F 110mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor or fixed to wall with suitable clamps complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor or fixed to wall with suitable clamps complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing water storage tank, 500 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm dia ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed by the Engineer-in-Charge.
S & F 15 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shall be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
M & L applying a coat of solar reflective aluminium paint @ 0.11 kg per sqm on APP membrane surfaces complete all as specified and as directed by the Engineer-in-Charge.
M & L providing PCC precast 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, precast cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weathering, throating etc and setting in cement mortar 1:4 complete with joints to match, complete all as specified and as directed by the Engineer-in-Charge.
M&L machine pressed rubber moulded coloured precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006, ISI marked of 60 mm thickness, grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in mud stops, bed blocks, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork for rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L for construction of 50 users septic tank including inlet chamber in any type of soil complete all specified and shown on drg No. STD-1320 (C) sheet 1/3 to 3/3 dated 25 Jun 2018 including removal of surplus soil to a distance not exceeding 100mtr and other necessary work to make functional complete all as specified and as directed by the Engineer-in-Charge.
M & L for construction of sokage well having internal diametre 1.80 metre and depth 3.00 metre from ground level in any type of soil complete all specified and shown on drg No. STD-1173 (C) sheet 1R/2 dated 25 Jun 2018 including removal of surplus soil to a distance not exceeding 100mtr and other necessary work to make functional complete all as specified and as directed by the Engineer-in-Charge.
S & F reinforced concrete pipe 150mm bore, class NP2, laid and jointed complete with collaras complete all as specified and as directed by the Engineer-in-Charge.
M&L for concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports complete all as specified and as directed. Note:-(i) Thickness of bed belew barrel of pipe -10 cm (ii) Width of bed :- outer dia of pipe plus 30 cm.
Dismantling wooden scantling 40 sqcm and over in section in framed work in position complete all as specified and as directed by the Engineer-in-Charge.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge
M&L rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
S & F 11 to 15mm dia of neck mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10 cm but n exc 15cm long complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 grams per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150grams/Sqm (Az-150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness including cover fillets and false ceiling frame work complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing false ceiling with semi perforated 12 mm thick micro tegular edged at all hights with GRG(glass fiber reinforced gypsum ) false ceiling tiles of size 595mmx595mm of approved texture ,design and pattern having moisture content less than 2% ,humidity resistance of 99% ,NRC 0.5 to 0.75 as per IS 8225-1987 ,non- combustile as per BS475 (part-4) -1970 and light code description unit rate No.429 SUB HEAD :26.0 new technologies and material reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 gms per sqm including both sides ) comprising of main -T runners of size 15x32mm of length 3000mm ,cross T of size 15x32mm of length 1200mm and secondry intermediate cross-T of size 15x32mm of length 600 mm to form grid module of size 600x600mm ,suspended from ceiling using galvanised mild steel items (galvanising @80 gms per sqm ) i.e, 50mm long ,8 mm outer diameter M-6 dash fastners ,6mm dia fully threaded hanger rod upto 1000mm length and L- Shape level adjuster of size 85x25x2mm . Galvanised iron perimeter wall angle of size 24x24x0.4mm of length 3000mm to be fixed on periphery wall /partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws . complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M&L rendering 15 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on wall by scrappers or any other means and washing , rubbing down with water to remove loose particlse etc and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on wall by scrappers or any other means and washing , rubbing down with water to remove loose particlse etc and applying two coats of oil bound distemper with painting roller over a coat of alkali resistant primer complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium section (minimum thickness of powder coating 50 micron) for doors,windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws complete all as specified and as directed by the Engineer-in-Charge. Note : (a). Glazing shall be measured and paid separately; (b). Weight of aluminium sections shall be as per IS or actual weight which ever less shall be measured. (c). The rates quoted shall be inclusive of neoprene beading, glazing clips, jointing clips, screws, etc as required and the same shall not be measured for arriving the weight; (d). The rates shall be inclusive of locking arrangement including complete packing with silicon gel alround contacting surface of aluminium framework and including matching the existing surface area complete all as specified and directed.
S & F anodised aluminium grill (anodized transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the window frame with C.P brass/ stainless steel screws @ 200 mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodized aluminium standard section around the opening, complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in holdfasts complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 100 mm size mild steel mortice lock, vertical type, 2 levers with duplicate key complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 4.8 mm thick figured, pin head type and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F stainless steel wire cloths 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staple complete all as specified and as directed by the Engineer-in-Charge.
S&F aluminium (Diecast) body hydraulically door closer regulated,designation No.3, universal type,suitable for door shutters of 851 mm to 1000 mm in width and weight between 61 to 80 Kg complete all as specified and as directed by the Engr-in-charge.
S & F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed by the Engineer-in-Charge.
S & F rubber strips 3 to 4 mm thick and 65 to 75 mm wide on bottom rail of door for covering gaps between door and floor to avoid entry of insects, dust etc and fixed with screws complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel curtain rod 25mm dia having wall thickness 1.6mm fixed with and including stainless steel decorative brackets, two lotto for each road length at both end etc complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' Part-II (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 109 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 109 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per srl item No 109 here-in-before but for one socket outlet 15 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Description same all as per srl item No 109 here-in-before but for one socket outlet 15 Amp with 4 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin combined, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 3/3 pin combined, (6pin), 6/16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F of electronic Fan regulator modular 100 watt, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
S&F LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP, 6-32 Amps, 240 volt,10 KA , 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP, 6-32 Amps, 240 volt,10 KA , 'C' curve as per site requirement complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN, 40 Amps, 240 volt,10 KA , 'C' curve as per site requirement complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN, 40 Amps, 240 volt,10 KA , 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve complete all as specified and as directed by the Engr-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 12 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) with MCCB 125 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Disconnecting electrical conncection from the street light, indoor tube light fitting/ ceiling light, bulk head fitting etc , taking down the same carefully and removing from the site complete all as specified and as directed by the Engr-in-charge.
Supply and fixing indoor decorative LED tube light fitting box type with opal diffuser, high efficient PVC housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED flat panel 2' x 2' size fully difused surface/ recess mounted fitting (grid/ gypsum type) 36-40 watt , 5700K, warm/cool white with powder coating and CRCA front cover including frame with provision of PVC flexible copper conductor cable to light fitting complete all as specified and as directed by the Engr-in-charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, auminum housing, surge protection including driver & LED lamp etc complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of heavy duty exhaust fan 300mm sweep with corrosion resistant metallic body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, metallic base frame with rubber mountings for silent operation, maximum watt input not more than 55 watt, 1400 RPM, metal blades and shutter type louvers self-openable/ closeble for protecting the entrance of birds as per IS :2132-1967 and testing complete all as specified and as directed by Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth strip protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm cross sectional area, 3.5 core with aluminium conductor, 1100 volts grade as in repair complete all as specified and as directed by Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 10 sqmm cross sectional area, 2 core with aluminium conductor, 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables, GI pipes and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair light grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by Engineer-in-Charge
S&F light grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by Engineer-in-Charge
M & L galvanised iron tubing 25 mm bore medium grade with all fittings and laid in trenches complete all as specified and as directed by the Engineer-in-Charge.
S & F 25 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F ceiling rod 60 cm long made from mild steel pipe 15mm bore powder coated having two holes at both end, heavy duty ‘U’ clamp, rubber reel, nuts, botls, washers and split pin, etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
M & L Cutting existing pipe 80mm /50mm bore for and including inserting GI tee 80x 80x 25mm/50x 50x 25mm for tapping complete all as specified and as directed by the Engineer-in-Charge.
Swami Enterprises
M/s B.S.Jain
shiv const co
V K Constructive Builders
Durga Enterprises
Jai Bala Ji
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .