| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.0 L+₹1.5 L (4.00%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹40.8 L+₹2.3 L (6.06%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹40.9 L+₹2.5 L (6.50%)Rejected-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹41.4 L+₹2.9 L (7.58%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
29 Dec 2022, 5:00 pmClosed
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
REPAIR AND MAIT OF INT WIRING WITH FITTINGS AND FIXTURES FANS GEYSERS COOLING APPLIANCES RO PLANTS LT UG CABLES STREET LIGHTS EXT WATER SUPPLY PIPE LINES AND PUMPS INSTALLED AT VARIOUS SECTORS AND ALL ESSENTIAL EM DAY TO DAY MAINT SERVICES LEKAWADA
2022_MES_568208_1
8813
Open Tender
Civil Works
Item Rate
270 days
LEKAWADA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹77,000
Yes
8 Feb 2023
9 Dec 2022
30 Dec 2022
9 Dec 2022
29 Dec 2022
23 Dec 2022
Amount
SCHEDULE 'A'
Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) and removing materials to store for considering the same in schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc complete all as spd and directed.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces including painting
M & L for in replacement point wiring using ISI marked 1.1 KV grade single core FR-LSH flexible cable of 1.5 Sqmm conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductor o, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size PVC cassing capping surface conforming to IS: 9537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, thick modular cover-plates complete all as specified in IS: 732- 1989 and directed. Make Havells/ Anchor/RR Cables (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of exsistng size is to be replace and rate quoted by bidder shall be inclusive of all these espects for following.
(a) One light/ Bulb Holder /fan/exhaust point / bell point controlled by one, one way switch
(b) One light point controlled by 2, Two way switch
(c) One 5 pin socket outlet 5/6 amps on the same board.
(d) One 5 pin socket oulet 5/6 amps on independent board..
(e) One 3 Pin socket out let 5 Amps on the same board.
(f) Out one 3 pin socket out let 5 Amps on the independent board.
(g) All as per item No 2 above but 2.5 sq mm wire for 15 amps power socket point.
S & F in in replacement of modular type 6 A one-way SP switch, conforming to IS: 3854-1997 with finger proof terminalcomplete as specified and directed.Make Anchor/ Havells/Legrend
S & F in replacement of modular type 16 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete as specified and directed .Make Anchor/ Havells/Legrend
S & F in replacement of modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293- 2005 complete as specified and directed.Make Anchor/ Havells/Legrend
S & F replacement of modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293- 2005 complete as specified and directed. Make Anchor/ Havells/Legrend
S & F in replacement of modular type 6 A bell-push conforming to IS: 8884- 1978 with finger proof terminal complete all as specified and directed.Make Anchor/ Havells/Legrend
S & F in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984 complete as specified and directed.Make Anchor/ Havells/Legrend
S & F in replacement of 6 A, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm complete all as specified and directed.Make Anchor/ Havells/Legrend
M & L for in replacment of Point wiring with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 650/1100 Volts grade drawn through and including non metallic PVC heavy duty cassing capping minimum 25 mm size but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm including cassing capping accessories like bends, tees, etc fixed on wall or ceiling etc including 1.5 Sq mm PVC insulated but unsheathed multi stranded copper conductor FRLSH cable as earth continuity wire of suitable size with 3 mm thick bakelite sheet white/coloured top cover for:-Make Havells/ Anchor/RR Cables Note (i) Exsisting metal sunkem box should not be removed (ii) Backlite sheet of exsistng size is to be replace and rate are deemed to be inlcuded in quoted rate.(iii) PVC box and switch board for mounting of switch sockets are deemed to be included in unit rate.
One light point/fan point/ bell point controlled by one, one way switch.
One light point controlled by 2, Two way switch
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
M & L for in replacment of Point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLSH cabel 650/1100 Volts grade conforming to IS-694 drawn through PVC cassing capping (minimum 25 mm size (external) or exsisting conduit but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLSH cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board as specified. Make: Havells/ Anchor/RR Cables Note (i) Exsisting metal sunkem box should not be removed (ii) Backlite sheet of exsistng size is to be replace and rate are deemed to be inlcuded in quoted rate.(iii) PVC box and switch board for mounting of switch sockets are deemed to be included in unit rate.
M & L for in replacment of Point wiring complete with 4.0 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLSH cable 650/1100 Volts grade conforming to IS-694 drawn through PVC cassing capping (minimum 25 mm size (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including 4.0 Sq mm PVC insulated but unsheathed copper conductor FRLSH cable as earth continuity wire for on AC metal socket box complete all as specified.Make Havells/ Anchor/RR Cables
Supply and fix in replacement of switch piano flush button 230 V, 6Amps, Single pole, way ISI marked complete all as specified and directed.Make Havells /Anchor/Cona
Supply and fix in replacement of Socket outlet flush type 2 in 1, 3 pin, 5A 230 Volt complete all as specified and directed.Make Havells /Anchor//Cona
Supply and fix in replacement of Socket outlet 3 pin, 15 Amp, flush type complete all as specified and directed.Make Havells /Anchor/Cona
Supply and fix in replacement of switch piano flush button 230 V, 16Amps, Single pole,one way ISI marked complete all as specified and directed.Make Havells /Anchor//Cona
Supply and fix in replacement of Rigid non-metallic PVC conduit of 25 mm dia of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified. Make Precision/Prince/Supreme
Supply and fix in replacement of Rigid non-metallic PVC conduit of 20 mm dia of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified Make Precision/Prince/Supreme
S&F in repair ding dong bell AC 230V
Supply and fixingin replacement of Polycarbonate type 65 mm dia ceiling rose 2/3 terminal suitable for 230 Volt complete all as specified and as directed Make Havells/Legrend/Anchor
Supply and Fixing in replaecment fan regulator steped type 230 Volt complete all asspecified and as directed Make Havells/Legrend/Anchor
M & L in replacment of submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm NB UPVC medium grade surface/recessed exsisting conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, and painting complete as specified and directed. for following Make: RR Kabel, Polycab, Havells, Finolex (HR-FR flexible cable) & Precision, Prince, Supreme (PVC conduit) NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of concealed conduit shall be measured as one length.
2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
Supply and fix in replacement of follwing DB sheet enclosure double door type single pole and neutral 240 Volt with stranded bus bar of follwing size enclosed in complete all as specified and as directed.
SPN DB double door 240 Volt 4 way with 200 amp rated bus bar complete with fixing accessories complete all as specified and as directed Make Hensal/Legrend/Schnider
SPN DB double door 240 Volt 8 way with 200 amp rated bus bar complete with fixing accessories complete all as specified and as directed Make Hensal/Legrend/Schnider
TPN DB double door 240 Volt 4 way with 200 amp rated bus bar complete with fixing accessories complete all as specified and as directed Make Hensal/Legrend/Schnider
Supply and fixing in reapir MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning. complete all as specified and as directed.
Supply and fixing in reapir MCB SPN 32 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning.complete all as specified and as directed.
Supply and fixing in reapir MCB TPN 63 Amp rating 415 V, 10KA 'C' curve complete with connection testing and commissioning.complete all as specified and as directed.
Supply and fixing in reapir Isolator 4 pole 40 Amp rating, 10KA 'C' curve complete with connection testing and commissioning
S&F in repair residual current circuit breaker (RCCB)/ELCB of DP of capacity 32Amp , 100 mA Amps and as directed by Engr In charge. Make Havells/ HPL/L&T/Indo Asian or equivalent complete all as specified and as directed.
S&F in replacement of track light, track mount LED COB luminarie with high efficacy housing made of extruded aluminium 240V, 50Hz, 20W, CCT 4000K, complete all as specified and as directed by Engr-in-Charge, Make: ld -57-251-024-40-XX Philips/ GE/Wipro Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate complete all as specified and as directed.
S&F in replacement of Sleek surface downlight LED recessed mounted luminaire,240V, 50Hz, 18W, CCT 5700 K, round in shape, cutout dimension 168 mm complete all as specified and as directed by Engr-in-Charge, fixed in repair. Make: LD06 -221-XXX-57RF* of Wipro /Philips/ GE Note- cost of replacing in existing cut out of false ceiling deemed to be included in unit rate complete all as specified and as directed.
Supply & fix in repair to replacement Sleek round recessed mounting LED downlight with AL die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation 6 W LED compact vertical round shaped downlighter low ceiling warm white/ day cool light /Ecco light including taking down of all as specified and as directed. make- Bajaj Cat No-BGSLO SLEEK 6W WH RD or Havells/CG/Philips or equivalent complete
Supply & fix in repair to replacement Sleek round recessed mounting LED downlight with AL die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation 18 W LED compact vertical round shaped downlighter low ceiling light including taking down all as specified and as directed. make- Bajaj Cat No-BGSLO SLEEK 18W WH RD or Havells/CG/Philips or equivalent
Supply & fix in repair to replacement environmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for armstrong/grid ceiling and POP mounting of cap 42 watt, size 2x2 complete including lectronic driver all as specified and as directed. Make - Havells, Ordering Code PLUTONEO2X2PLR42WLED840S or PHILIPS/WIPRO or equivalent
S&F in repair to replacement decorative wall light, gold finish fixture with white glass diffuser suitable for 7.5 W LED filament lamp E27 base as per cat part No LHFOAKD1TZ1D060 of Havells or equivalent Philips/Bajaj/Orient
S&F in repair to replacement Environment friendly, energy efficient, aesthetically designed, surface ornamented with rings, moulded body, wall/ceiling light LED fixture with diffuser to give glare free light for 8 watt including taking down old fitting all as specified and as directed. make-Havells Code No-LHEBKJP7OZ1W008 ,Philips/HPL/Wipro/CG or equivalent
S&F in repair to replacement recess mounted 15 W LED compact edge pro range of silm fit low profile down light including taking down old unsv light as per cat part No EDGEPRORDDLR15WattLED 84OS of Havells or Philips/wipro/SySka/CG or equivalent all as specified and as directed.
S & F in repair to replacement LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with flexible copper conductor cable of suitable size including taking down the old unsv fittings of make-Philips/HPL/Orient/SYSKA or equivalent all as specified and as directed.
S & F in repair to replacement swivel COB LED down light fitting 12 W with crysp light throw and high CRI of warm white/ day cool lioght including connecting up with flexible copper conductor cable of suitable size including taking down the old unsv ght of Make-Havells Ordering Code-LHGEEGEPGIE1W012 or eqivalent all as specified and as directed. make-Philips/HPL/Orient/SYSKA
Taking down of followin items for servicing, cleaning all the dust partical and oiling and greasing the bearing and cheking the electrical connection, including painting and refixing of ceiling fan/exhaust fan and wall mounted fan in situ complete aall as spd and directed. Note: (i) Spare parts will be measured and paid separatly . (ii) Rewinding/repair of fan motor will be measured and paid seprately.
Ceiling Fan 1200 mm sweep
Exhaust Fan 240/300 mm
Exhaust Fan 450 mm
Wall mounted fan 300 mm
M & L for cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling and other repairing work complete all as spd and directed by Engineer-in-Charge.Note Taking down and refixing charges will be paid under relvent items
Ceiling Fan 1200 mm sweep
Exhaust Fan 240 mm
Exhaust Fan 450 mm
Wall mounted fan 450 mm
Supply only spare parts of Fan/Exhaust fan of following rating all as spd and directed
Capacitor 2.5 MFD
Capacitor 3.15 Mfd
Ball Bearing No 6201
Ball Bearing No 6202
Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample
Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample
Dismantling electric/water connection and taking down of storage type water heater,servicing,cleaning of inner tank etc.at site.and replacement of burnout parts etc. and refixing in situ all spd and directed. Note- wornout parts shall be measured as seperatly.
Supply & fix in replacement of Heating element 1.5/2 KW Tringular/ circular type with rubber gasket complete all as specified and as directed
Supply & fix in replacement Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked complete all as specified and as directed
Supply & fix in replacement 3 core 1.5/2.5 sqmm PVC insulated cable complete all as specified and as directed at site
Supply in fix in replacment of body of geyser 25 Ltr capacity vertical type with new body complete with 1.5 Kw heating elements, led indicator lights complete all as specified and as directed.
Supply and fix in repair Surface and wall mounted LED batten 20/22 watt 4 feet, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% including taking down old unsv batten. of Make-Havells, Odering Code-ENDURALINEARNEOBS20WLED865SPCWH or equivalent Cat No all as specified and as directed. Make-Philips/Bajaj/Wipro
S&F LED post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection made in cast aluminium spigot housing with decorative clear acrylic diffuser with 70W LED and inbuilt driver including taking down the old unsv light all as specified and as directed. .Make: Bajaj Celesta Model No. BGCL 70W LED or Havells/Philips/CG or equivalent
S&F LED step light 9 watt with die-cast aluminum housing designed for rugged outdoor usage & IP 65 protection of cat part No BGSBL 9W LED warm white including taking down the old unsv light (Product Code- 112146) all as specified and as directed. make- Bajaj or Philips/CG/Havels or equivalent
S&F in repair Cone LED Bollard light 8W, new generation, energy saving, environmetal friendly, long life aesthetically designed aluminium landscape luminaire for diffuser lighting with high power LED , IP 65 warm white complete with nut, bolt and PCC Foundation including taking down the old unsv bollards complete all as specified and as directed Make- Wipro Catno:- Bajaj/Philips//CG or equivalent
S&F in repair Cone NXB LED Bollard light 8W, new generation, energy saving, environmetal friendly, long life aesthetically designed aluminium landscape luminaire for diffuser lighting with high power LED , IP 65 warm white complete with nut, bolt and PCC Foundation including taking own the old unsv bollards all as specified and as directed Make- Havells, Item Description CONENXGBLS8WLEDPSYM830PSYMTOPC or Bajaj/Philips/Wipro /CG or equivalent
S&FLED Garden light 8W, new generation, energy saving, environmetal friendly, long life aesthetically designed aluminium landscape luminaire for diffuser lighting with high power LED , IP 65 bamboo, including taking down the old unsv light as per cat part No BAMBOOBL8WLED857SSYMTOPCM(1M) all as specified and as directed. Havells or Bajaj/Philips/Wipro /CG or equivalent
S&F in repair 60 watt LED street light, compact and aesthetic aluminium powder coated housing with precise street optics lense, IP66 fix on existing bracket and connection to existing electric network including taking down the unsv old light complete all as specified and as directed Make:- Wipro Cat No lr-13-671-XXX-57-XX or Bajaj/HPL/Philips/GE or equivalent
S&F Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66,70W LED flood light,suitable for highlighting architectural facade and general purpose lighting including taking down the old unsv fittings. of make Havells , 50 Hz. Incl IP 65 as per existing at site.Make :- Havells, Item Description-JETA PROFL70WLED757LT or CG/Philips/HPL./Syska or equivalent
S&F in repair LED bollard in rectangular shaped victorian design with opal acrylic diffuser and IP 65 protection , integral type decorative with opal acrylic cover including takinng out old unsv bollard all as specified and as directed. Make-Bajaj product code 111771 type BGBOS 600 9 watt LED warm white colour or equivalent and as directed by Engr-In-charge.
Excavation in trenches n.exc 1.5 mtrs wide and n. exc. 1.5 mtr in depth for laying of electric cables for fixing of poles and stay or for laying pipes (where provided for protection of cables) and getting out trimming the sides forming bottom surface to required level in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed.
Removal of surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge
M&L preparing old rusted surface of steel tubular pole by means of sand paper/scrubing of dust etc and apply one coat of red oxide on surface of Metalic poles and applying two coats of silver paint on Pole and numbering of poles with synthetic enamel paint white in 100 mm high letters over 150x150 mm black base complete all as spd and as directed by Engineer-in-Charge.
Supply and fix in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection including taking down old unsv box complete all as specified and directed Make : Hensel Cat No.DK 2525 G or its equivalent in Legrand/sintex
Supply & Lay in replacment of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area for following size of cable Make: Polycab/ Asian/ Gloster/Havells/KEI
(a) 10 Sqmm 4 Core
(b) 95 Sqmm 3.5 Core
(c) 35 Sqmm 3.5 Core
Note : for Item No 66 Removing of interlocking/Paverblocks, tiles and refxing with the same location and making good the distrubed surface is deemed to be included in quoted rate.(ii) Fixing accessories for cable layingsuch as clamps and nut bolts are to be included in quoted rate.
Supply and Lay in replacment of OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches/road/nallah or fixed along wall poles or laid under floor for the following dia (Excavation and earthwork shall be measured and paid separately) complete all as specified and as directed for all as specified and as directed. Make: Rex/Poly/Geminie (i) Fixing accessories for pipe laying such as clamps and nut bolts are to be included in quoted rate.
50 mm Outer dia
63 mm Outer dia
M & L for Cutting & removing existing joint and supply, jointing and testing straight through Hot shrinkable cable joint including all materials and accessories suitable for 3.5 core XLPE cable of 1100 volts grade complete all as specified and as directed all as specified and as directed. Make: 3M/Denson/Raychem RPG Note : Excavation and Earthwork shall be measured and paid seperately under respective item of this schedule.
25 sq mm to 50 sq mm
70 sq mm to 150 sqmm
185 sqmm to 240 sqmm
Comprehensive maintenance and servicing of air conditioner of model DSA1021R1 ductable type comprising of hermetic/ semi harmetically scrolled compressor indoor/out door unit with refrigerant use R--22/ R-407 C /R 410A, of capacity 8.75 TR, making servicing of the plants and making fully in serviceable condition installed at ICGS Udhyog bhawan complete all as specified and as directed. Make:- Blue Star Note:- (i) The rates quoted by the tenderer includes the cost of complete comprehensive service including replacement of spares as required and visit the site at interval of 90 days to verify functioning of AC units till completion of contract as mentioned in Work Order No. 1. (ii) Rates inclusive of replacement of parts during currrency of contract as and when directed by Engr-in-Charge. (iii) Servicing/ Repairs of AC units shall be carried out through the OEM only. (iv) Contractor has to submit test certificate on completion of service/ repairs of AC units issued by service provider. (v) contractor is responsible to proper functioning of AC, leakage and seapage repiare is sole responsibility of contracter quoted rates should incl leakage and seapage repaire. (vi) this is Type 'A' AMC i.e. ALL IN ALL so that spares required will be provided by the contracter with in stipulated time period. (vii) complaints should be attended and rectified in 24 hr otherwise a penalty of rupees 2000.00 Rs per day will be recoverd from the contractor.
M & Lfor servicing and testing of Split type air conditioners of 1.5/2 ton capacity of any make inverter / non inverter complete for minimum two times during the contract period of each unit by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, compressor greasing of blower motor, checking and removing any vibration, remvoing and cleaning the air filter pad testing after fixing at site all as directed.
M&L for detecting the cause of leakage in any type/capacity of 1.5/2 ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning complete all as spd and as directed by Engr-In Charge Notes :- (i) Dismantling of unserviceable compressor, cost of refrigarent gas and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates.
M & L for repairing of PCB suitable for split type AC 1.5 TR type indoor unit complete all as specified and as directed.
All as per Item No 68 above but for split type AC 2 TR for indoor unit
M & l for replacement of indoor cooling coil of split type AC 1.5 TR unit complete all as specified and as directed.
All as per Item No 70 above but for split type AC 2 TR
M & Lfor replacement of Blower motor,single phase,280-380Volt ,50Hz 3 speed for 1.5 Ton indoor unit complete all as spd and directed.
All as per Item No 72 above but for split type AC 2 TR
M & L in replacement of remote suitable for 1.5/2 Ton all as spd and directed.
M & L for replacement of Drain out PVC Pipe of 11/16 inch dia/17.79 mm innerdia for 1.5 Ton/2 ton ac complete all as spd and directed.
M & L for replacement of swing motor 230Volt for 1.5/2 Ton ac complete all as spd and directed.
M &L for replacement of compresser of outdoor unit of split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 77 above but for split type AC 2 TR
M & L for replacement of out door copper condencer unit of size 20x 30inch size cu tubing size 6 mm dia for outdoor Unit of split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 79 above but for split type AC 2 TR
M & L for replacement of fan motor for ac 230Volt 1180 Rpm for outdoor unit split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 81 above but for split type AC 2 TR
M & L for replacement of running capacitor for motor of capacity 2/4/6 mfd 230 volt suitable for 1.5/2.0 Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of compresser running capacitor of 50 mfd 230 volt suitable for 1.5/2.0 Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of compresser starting capacitor of 45 mfd 230 volt suitable for 1.5/2.0 Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of fan motor blade suitable for motor of 1.5/2 Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of suction copper tubing of size 5/16'' dia meter with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge.
M & L for replacment of discharge copper tubing of size exsisitng size mm bore including brazing etc and with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge
M & L for with rubberised insulation cover inclduing tape suitable supply pipes for air-conditioners complete all specified by Engineer -in-Charge
Supply and fixing cable PVC insualted multistranded cu concutor pvc cable of 3 core 3 Sqmm size complete all as specified and directed by Engineer -in-charge
S & Fin replacement of outdoor unit stand of metal inclduing fixing accessories such as nut bolt washers and fastner for 1.5/2 Ton outdoor unit complete all as specified and as directed
S & Fin replacement of indoor unit bracket of metal inclduing fixing accessories such as nut bolt washers and fastner for 1.5/2 Ton outdoor unit complete all as specified and as directed
S & Fin replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed Make ABB/Havells/legrend
M & L for repairing of PCB suitable for Inverter type split type AC 1.5 TR type indoor unit complete all as specified and as directed.
All as per Item No 94 above but for split type AC 2 TR for indoor unit
M & Lfor replacement of Blower motor,single phase,230V,ac for 1.5 Ton indoor unit of Inverter AC complete all as spd and directed.
All as per Item No 96 above but for split type AC 2 TR for indoor unit
M & l for replacement of indoor condencer copper coil of inverter split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 98above but for split type AC 2 TR for indoor unit
M & l for replacement of oudoor condencer unit of copper with 2 run of copper pipe of out door unit of inverter split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 100 above but for split type AC 2 TR for outdoor unit
M &L for replacement of compresser of outdoor unit of split type AC 1.5 TR inverter type complete all as specified and as directed.
All as per Item No 106 above but for split type AC 2 TR for indoor unit
M & L for replacement of swing motor 230 Volt for 1.5Ton indoor unit inverter type ac complete all as spd and directed.
All as per Item No 104 above but for split type AC 2 TR for indoor unit
Taking down of split type AC1.5Ton Inverter type from site for replacement of outdoor unit and re installing split type AC at site and including refixing of outdoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate.Make Voltas/Carrier/Hitachi
All as per item No 106 above but for 2.0 Ton ac
Taking down of split type AC1.5Ton Inverter type from site for replacement of indoor unit and re installing split type AC at site and including refixing of indoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate.Make Voltas/Carrier/Hitachi
All as per item No 112 above but for 2.0 Ton ac
M&L for taking out desert cooler of any size and capacity from existing site for repair and dismentaling of all components from evoparative cooler (desert cooler) metal body very care fully i.e. exhaust fan, motor, tulu pump, PVC spare parts i.e distributor, PVC pipe, tee, bend, elbow, holding clamp and any number of nut, bolt, washer, grass paid etc, including praparation of exterior and interior portion on cooler to a smooth finish and applying one coats of bituminious paint and reaasembling the same in existisng position in cooler for smooth running complete all as specified and as directed. Note:- If any worn out items/ parts found during the assembling the same shall be measured and paid separately under the relavent items of schedule.
S&F in repairs PVC connection set of three suitable for existing desert cooler.
S&F in repairs cable three core flexible twiested copper conductor of 1.5 Sqmm.
S&F in repairs cable three core flexible twisted copper conductor of 2.5 Sqmm.
S&F in repairs front grill suitable for existing desert cooler.
S&F in repairs grass paid set of three superior quality.
S&F in repairs motor 1.0 Ph, 50 HZ 230 V, AC max Amp 1.5, suitable for existing desert cooler.
S&F in repairs tillu pump/ water pump for deseart cooler 240 V, AC 50 HZ, 10 Watt, 5 LPM, 2.0 mtr head.
S&F in repairs capacitor 4 Mfd + 5% 440 V MPP 'SH'
S&F in repairs capacitor 6 Mfd + 5% 440 V MPP 'SH'.
S&F in repairs gas filter and NRV suitable for existing refrigerator and water cooler of cap 40-280 ltr.
S&F in repairs drain pipe for water cooler.
S&F non adhesive tape roll for copper tubing of AC.all as specified and as directed.
S&F in repairs fan blower suitable for existing split AC.all as specified and as directed.
Comprehensive maintenance/ servicing and testing of RO plant including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set and dosing unit complete at so as to supply qualitative water at permissible level of TDS. Note:- (a) Spares required for replacement will measured and paid separately under respective items here-in-this schedule. (b) The rate quoted by the tenderer includes cost of maint/ servicing of above said plant once in a period of 90 days till the date of completion of work. (c) Servicing should be done by OEM/ authorized agency and not by any local mechanic. (d) Contractor shall be produce all purchase voucher and test certificate before submitted RAR. Note:- (i) Servicing should be done by OEM/ authorized agency and not by any local mechanics. (ii) Spare parts required will be measured and paid separately in relavant items of this schedule (iii) Replacement of sedmentation filter in each visit is deemed to be included in the unit rate.
S&F in repairs RO membrane as existing for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs RO membrane Housing as existing 50/60 ltrs RO plant all as specified and as directed.
S&F in repairs carbon filter for 50/60 LPH Ltrs RO plant all as specified and as directed.
S&F in repairs spum filter for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs PF candle for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs cartridge filter of 50/60 ltr RO. all as specified and as directed.
S&F in repairs control module of 50/60 Ltrs RO plant all as specified and as directed. .
S&F in repairs low/ high pressure switch of 50/60 Ltrs RO plant.
S&F in repairs pump for 50/60 Ltrs RO plant all as specified and as directed. .
S&F in repairs 1/2 Pipe for 50/60 Ltrs RO plant.
S&F in repairs solenoid valve of 230 Volt for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs raw water pump for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs dosing pump for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs water controler sensor for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs UV system for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs low pressure/ High pressure DC switch for 50/50 Ltrs RO plant all as specified and as directed.
S&F in repairs stainer for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs anti scalant chemical all as specified and as directed.
Supply and fix solenoid valve for 50/60 Ltrs RO plant all as specified and as directed.
S&F in repairs booster pump 48 VDC suitable for 50/ 60 Ltrs RO plant all as specified and as directed.
Dismantling, cleaning and overhauling of 0.25/0.5 HP centrifugal mono block pump set/ pressure booster pump set of the following capacities including rewinding of motor with appropriate super enameled copper wire of existing gauge, replacement of bearing - 02 Nos, including all connection and testing complete for all as specified and as directed. following capacities:- (i) Replacement of bush (gland). (ii) Replacement of pump shaft. (iii) Replacement of impeller. (iv) Replacement of shaft sleeve.
Jyoti Refrigeration
Shree Builders
M/s SK Traders
K K Construction Co
M/s PATEL ENGINEERING
M/s Matadeen Ramchandra Agarwal
SNEH TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .