Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | GR POWER SWITCHGEAR LIMITEDLikely winner L1₹53.5 CrQualified KOTAMMA BHAWAN 27 B IDA IV PHASE JEEDIMETLA HYDERABAD 500055 | HYDERABAD | HYDERABAD | TELANGANA | 500055 | L1 | Qualified MII | |
| 2 | L2₹53.7 Cr+₹29.4 L (0.55%)Qualified PLOT NO 132 133 PHASE V IDA JEEDIMETLA HYDERABAD RANGAREDDY TELANGANA 500055 | MEDCHAL MALKAJGIRI | TELANGANA | 500055 | L2 | Qualified MII | |
| 3 | L3₹53.9 Cr+₹39.4 L (0.74%)Qualified UDL II 9 SURVEY NO 304 P 305 P 274 P GANDRAJUPALLI CHITTOOR CHITTOOR ANDHRA PRADESH 517432 | CHITTOOR | ANDHRA PRADESH | 517432 | L3 | Qualified MSE, MII, Category: OBC | |
| 4 | Disqualified PLOT NO 11 S S POWER SWITCHGEAR EQUIPMENT LIMITED CMDA INDUSTRIAL AREA CHITHAMANUR VILLAGE MARAIMALAI NAGAR CHENGALPETTU KANCHIPURAM 603209 | CHENGALPATTU | TAMIL NADU | 603209 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
21 Sept 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Published by the portal on this tender, for queries and grievance redressal.
Supply and Retrofitment of 400 kV DBR Isolators
9622847
GEM/2026/B/7801265
Two Packet Bid
Supply of 420KV,3150A,63kA Isolator 3-Phase Double Break with one ES - HYDERABAD,Retrofitment of 42
Telangana; Palnadu, Andhra Pradesh; Peddapalli, Telangana; Khammam, Telangana; Ntr, Andhra Pradesh; Visakhapatanam, Andhra Pradesh; Spsr Nellore
Total value wise evaluation
BOQ
3 documents required · 3 mandatory
Power Grid Corporation of India Limited, Power Grid Corporation of India Limited, Central Procurement Cell, Plot No. – 2A/INS 02, Avadh Vihar Yojna, Amar, Shaheed Path, Near Medanta Hospital, Lucknow- 226002 (UP), (Powergrid)
Exempted
Yes
11 Nov 2026
27 Jul 2026
22 Sept 2026
180 days from bid end date (until 20 Mar 2027)
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supply of 420KV,3150A,63kA Isolator 3-Phase Double Break with one ES - HYDERABAD | Supply of 420KV,3150A,63kA Isolator (3-Phase) (Double Break) with one E/S as per TS including Support insulators, terminal connectors & support structure(Conforming to std drawing) suitable for existing foundation . | 5 | set | consigneehyderabad3 | 730 |
| 2 | Retrofitment of 420KV,3150A,63kA Isolator 3-Phase Double Break with one ES - HYDERABAD | Retrofitment of 420KV,3150A,63kA Isolator (3-Phase) (Double Break) with one E/S as per TS including Support insulators, terminal connectors & support structure(Conforming to std drawing) suitable for existing foundation . | 5 | Set | consigneehyderabad3 | 730 |
| 3 | Supply of 420KV,3150A,63kA Isolator 3-Phase Double Break with two ES - HYDERABAD | Supply of 420KV,3150A,63kA Isolator (3-Phase) (Double Break) with two E/S as per TS including Support insulators, terminal connectors & support structure(Conforming to std drawing) suitable for existing foundation. | 1 | set | consigneehyderabad3 | 730 |
| 4 | Retrofitment of 420KV,3150A,63kA Isolator 3-Phase Double Break with two ES - HYDERABAD | Retrofitment of 420KV,3150A,63kA Isolator (3-Phase) (Double Break) with two E/S as per TS including Support insulators, terminal connectors & support structure(Conforming to std drawing) suitable for existing foundation. | 1 | Set | consigneehyderabad3 | 730 |
| 5 | Supply of 40mm MS ROD - HYDERABAD | Supply of 40mm MS ROD (Mild Steel rod as per IS 2062/ SAE1018) and Freight charges for Supply of 40mm MS ROD | 520 | Meter | consigneehyderabad3 | 730 |
| 6 | Associated Work Annex -F - HYDERABAD | Associated Work Annex -F | 1 | Lot | consigneehyderabad3 | 730 |
| 7 | Supply of 420KV,3150A,63kA Isolator 3-Phase Double Break with one ES - NAGARJUNASAGAR | Supply of 420KV,3150A,63kA Isolator (3-Phase) (Double Break) with one E/S as per TS including Support insulators, terminal connectors & support structure(Conforming to std drawing) suitable for existing foundation. | 9 | set | consigneeguntur1 | 730 |
| 8 | Retrofitment of 420KV,3150A,63kA Isolator 3-Phase Double Break with one ES - NAGARJUNASAGAR | Retrofitment of 420KV,3150A,63kA Isolator (3-Phase) (Double Break) with one E/S as per TS including Support insulators, terminal connectors & support structure(Conforming to std drawing) suitable for existing foundation. | 9 | Set | consigneeguntur1 | 730 |
| 9 | Supply of 40mm MS ROD - NAGARJUNASAGAR | Supply of 40mm MS ROD (Mild Steel rod as per IS 2062/ SAE1018) and Freight charges for Supply of 40mm MS ROD | 853 | Meter | consigneeguntur1 | 730 |
| 10 | Associated Work Annex -G - NAGARJUNASAGAR | Associated Work Annex -G | 1 | Lot | consigneeguntur1 | 730 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9622847.pdf
GEM_BID • 0.29 MB
ts_upload_2026-07-17-14-26-11_7b8f44eb6548904d6b47b53de703262e.pdf
BOQ • 13.07 MB
boq_2026-07-17-14-26-11_47e52842189c4f758c4a8f919ac871b8.csv
BOQ • 0.01 MB
1784278821.xlsx
GEM_OTHER • 0.02 MB
IP_8e9c3fd8-85a3-4c8a-98921784279135661_buyercpc3.pdf
GEM_OTHER • 0.13 MB
BATC_3d0a12b8-fd1e-48e3-a79e1784610657286_buyercpc3.pdf
GEM_OTHER • 1.11 MB
gtc.pdf
GEM_OTHER • 0.71 MB
corrigendum_4506376.pdf
PDF • 0.06 MB
IP_8e9c3fd8-85a3-4c8a-98921784279135661_buyercpc3.pdf
PDF • 0.13 MB
BATC_3d0a12b8-fd1e-48e3-a79e1784610657286_buyercpc3.pdf
PDF • 1.11 MB
corrigendum_4506376.pdf
PDF • 0.06 MB
IP_8e9c3fd8-85a3-4c8a-98921784279135661_buyercpc3.pdf
PDF • 0.13 MB
BATC_3d0a12b8-fd1e-48e3-a79e1784610657286_buyercpc3.pdf
PDF • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .