Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹43.4 L+₹5.0 L (13.1%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹44.5 L+₹6.1 L (15.9%)Rejected-Finance PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹46.7 L+₹8.3 L (21.5%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L4 | Rejected-Finance BEING L4 | |
| 5 | Rejected-Technical PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | - | Rejected-Technical NOT ENLISTED WITH CATEGORY a(ii) |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 May 2025, 6:00 pmClosed
GE (I) CG PORBANDAR
COAST GUARD DHQ NO 1, OPP BIRLA FACTORY
REPAIR MAINT OF EXTERNAL WATER SUPPLY INTERNAL AND EXTERNAL ELECTRIC SUPPLY SUPPLY AND MAINTENANCE OF STP TTP BLOWERS PUMPS DG SETS SOLAR WATER HEATERS AND MISC E/M ITEMS DHQ 1 ICGAE AND CG JETTY UNDER GE (I) CG PORBANDAR
2024_MES_688567_3
8036A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
PORBANDAR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE I CG PORBANDAR
₹90,000
Yes
31 May 2025
16 Apr 2025
12 May 2025
16 Apr 2025
10 May 2025
24 Apr 2025
Amount
Schedule 'A' E/M
Servicing of DG set ('C' Check) of Cap 20 KVA to 25 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system, complete and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Diesel Filter (b) Oil Filter (c) Coolent ( Top up) (d) Lubrication oil (top up) Make of DG set: Ashok Leyland/ Greaves Cotton/ kirloskar/Mahindra Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Servicing of DG set ('C' Check) of Cap 62.5 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system complete and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Diesel Filter (b) Oil Filter (c) Coolent ( Top up) (d) Lubrication oil (Top up) Make of DG set: Ashok Leyland/ Greaves Cotton/ kirloskar/Mahindra Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Servicing of DG set ('C' Check) of Cap 250 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system complete and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Diesel Filter (b) Oil Filter (c) Coolent ( Top up) (d) Lubrication oil (Top up) Make of DG set: Ashok Leyland/ Greaves Cotton/ kirloskar/Mahindra Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Supply only parts / Items of DG set 20-250 KVA and including taking down old unserviceable part.
Engine Oil 20W / 40 Make : Castrol/Servo/IOC/HP
Coolent
AVR of DG for 20/25 KVA capacity including with connection, complete all as specified and directed by Engineer-in-Charge.
AVR of DG for 62.5 KVA capacity including with connection, complete all as specified and directed by Engineer-in-Charge.
Sercvicing of raidator cleaning with hydrocholoric acid
Water Pump Assembly of any capacity
V belt as per existing size
Hose pipe set
Battery Terminal
Fuel pipe
Material & Labour for disconnecting the connection of alternator' from 62.5 KVA DG set, lifting & shifting of alternator removal and fittment of at site trasportation TO & FRO complete, and removes the old main stator rewindings, excitor stator rewindings and excitor rotor rewindings complete Replace the copper winding of coils with new sleeve complete refixing with nuts and bolts, replacement of radiator water level switch, replacement of radiator water level switch, replacement of cogged belt AX/44 and making the connection of coils, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for disconnecting the connection of alternator from 20 /25 KVA DG set and removes the old main stater rewindings, excitor stator rewindings and excitor rotor rewindings complete Replace the copper winding of coils with new sleeve complete refixing with nuts and bolts and making the connection of coils, complete all as specified and directed by Engineer-in-Charge.
Loading, unloading and Tranportation charges for reparing /winding of rotor or stator from DHQ No 1 / CGAE to repairing workshop inclduing all type of tools and plant and return back, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repalcement DIOD assembly Set for 20/62.5 KVA DG Set, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for servicing cheking the connection of main rotor of DG Set, cleaning the dust paritcal, complete all as specified and directed by Engineer-in-Charge.
Materials and Labour for scraping removing and cleaning old rusty paint from enclosure of DG set 20 KVA to 62.5 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint, complete all as specified and directed by Engineer-in-Charge.
Materials and Labour for scraping removing and cleaning old rusty paint from enclosure of DG set 250 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint, complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable LT cables of any size, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, connecting, testing and commissioning and jointing, LT under ground cable of size 120 Sqmm 3.5 core, 1100 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in renches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable taxiway cables of any size, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, connecting, jointing in replacement of PVC insulated stranded plain anneled copper PVC insulated & PVC sheathed of 5KV grade single core 6 Sqmm underground taxiway cables, cable laid under roads/ path/drain/ hardstandings or encased in GI pipe fixed & testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of taxiway medium intensity omini direction, elevated light with one watt LED for operation at 6.6 amps. Series circuit with an integrated encapsulated electric module, with Die cast aluminium alloy fragible body finished with stove enamel aviation yellow with stainless steel hardware with lens of heat resistant and terminal shock pressed glass provided with heat and weather resistant neoprene rubber gasket, equiped with a 14" long secondary lead as FAAL-823, mounted on a breakable coupling confirming IS 7785 part I-V, including cable connector kit blue lens, CI base plate and accessories, complete all as specified and directed by Engineer-in-Charge. Make AMA or Equivalent as approved by GE.
Material & Labour for cutting existing road/hard standing not exceeding 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish surface 10 cm from top using PCC 1:2:4; including removal of surplase soil, complete all as specified and directed by Engineer-in-Charge.
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories, including taking down old unservicable DWC pipe, Complete all as specified and directed by Engineer-in-Charge. Note: Cutting of floor/ road and making good with PCC deemed to be included in item rate. Make: Rex/Poly/Gemini DWC Pipe of Following sizes:-
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in soft / loose soil, complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well Ramming in layers not exceeding 25 cm thick, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge.
Taking up/down CI/DI pipes with connection from trenches including connected fittings/accessories complete of 80/100 mm bore size and removing the pipes and reused to site,complete all as specified and directed by Engineer-in-Charge.
Supply, laying, testing & jointing in trenches DI pipes class K-7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 100mm dia ISI, complete all as specified and directed by Engineer-in-Charge.
Supply, laying, testing & jointing in trenches DI pipes class K-7 of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating an external surface with bituminious paint of size 80mm dia ISI, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of size 50mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of size 32mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of size 25mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of size 50mm dia, PP-R Ball valves (brass insert) as per requirement of the site, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of size 32mm dia, PP-R Ball valves (brass insert) as per requirement of the site, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of size 25mm dia, PP-R Ball valves (brass insert) as per requirement of the site, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches, complete all as specified and directed by Engineer-in-Charge. of following sizes:
20 mm dia
40 mm dia
Taking down GI tubing 80 to 100 mm bore of any description, complete all as specified and directed by Engineer-in-Charge.
Material and labour GI tubing 100mm dia medium grade galvanized with all fittings fixed on wall / ceiling / structure complete in trenches, complete all as specified and directed by Engineer-in-Charge.
Material and labour GI tubing 80mm dia medium grade galvanized with all fittings fixed on wall / ceiling / structure complete in trenches, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, cutting as necessary, gusset plates, riveting, etc.. not exceeding 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') as the H framed type structure supports, hot or cold drilling holes for both in any shape or size as indicated or directed by Engineer-In-Charge and inclusive of one primer coat one under coat and one finishing coat of synthetic enamelled paint including preparation of surfaces, including taking down old unserviceable scrap iron, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repalcement of ISI marked ductile iron socketed fittings supplied as per IS: 9523/2000 of class K-12, PN-10 for pressurized water delivery with inside Cement Mortar lining and outside zinc followed by black bitumen coating for size 80mm dia to 150mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch, cross collars, caps and plug set including rubber ring push on joints, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repalcement rubber gasket (Tyton) joints suitable for 100mm bore CI/DI pipe and fittings including jointing material, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repalcement rubber gasket (Tyton) joints suitable for 80mm bore CI/DI pipe and fittings including jointing material, complete all as specified and directed by Engineer-in-Charge.
Suppy and fixing in replacement of sluice valve 100mm dia class PN 1.6, cast iron body flanged type including fitting with suitable size of nut,bolts, washer and rubber gasket, complete all as specified and directed by Engineer-in-Charge.
Suppy and fixing in replacement of sluice valve 80mm dia class PN 1.6, cast iron body flanged type including fitting with suitable size of nut,bolts, washer and rubber gasket, complete all as specified and directed by Engineer-in-Charge.
Dismantling monoblock pump set centrifugal type of cap 10 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site incl. electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Dismantling monoblock pump set centrifugal type of cap 5 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site incl. electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Supply only ball bearing suitable for 10 HP of monoblock/pump set motor, including taking down old unserviceable ball bearing, complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing suitable for 5 HP of monoblock/pump set motor, including taking down old unserviceable ball bearing,complete all as specified and directed by Engineer-in-Charge.
Dismantling/taking down bore well submersible pump set of cap 7.5 HP to 10 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enameled copper wire as per existing gauge re-fixing the same at site including. Electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. Note : Cost of dismantling/taking down of bore well pump and re-fixing deemed to be included in quoted rate.
Dismantling/taking down bore well submersible pump set of cap 15 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enameled copper wire as per existing gauge re-fixing the same at site including. Electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. Note : Cost of dismantling/taking down of bore well pump and re-fixing deemed to be included in quoted rate.
Supply of bush/bearing (gun metal) of suitable size for 7.5 to 15 HP for the submersible motor, including taking down old unserviceable bush/bearing, complete all as specified and directed by Engineer-in-Charge.
Supply of stainless steel sleeve of suitable size for 7.5 to 15 HP, including taking down old unserviceable SS Sleeve, complete all as specified and directed by Engineer-in-Charge.
Supply of thrust plate set 7.5 to 15 HP, including taking down old unserviceable thrust plate, complete all as specified and directed by Engineer-in-Charge.
Dismantling and opening/ Repair and refixing of defective submersible pump set bowl assembly of any size 7.5 HP to 10 HP and re-assembling after repairing by lathe work and other machinery work as required and replacement of studs, nuts, bolts etc., refixing the same after making it serviceable in its existing position including test and commisioning, complete all as specified and directed by Engineer-in-Charge. Note: Defective spare parts of bowl assembly shall be measured and paid under relavant items.
Supply only submersible pump bowl assembly of gun metal impeller suitable for 7.5 HP to 10 HP, including taking down old unserviceable bowl assembly, complete all as specified and directed by Engineer-in-Charge.
Supply only submersible intermediate bowl suitable for 7.5 HP to 15 HP,including taking down old unserviceable bowl, complete all as specified and directed by Engineer-in-Charge.
Supply only submersible bowl bush (rubber) suitable for 7.5 HP to 15 HP, including taking down old unserviceable bowl bush, complete all as specified and directed by Engineer-in-Charge.
Supply only submersible bowl bush (gun metal) suitable for 7.5 HP to 15 HP, including taking down old unserviceable bowl bush, complete all as specified and directed by Engineer-in-Charge.
Supply only submersible cast iron impeller seal ring (neck ring) suitable for 7.5 HP to 15 HP, including taking down old unserviceable cast iron impeller seal ring, complete all as specified and directed by Engineer-in-Charge.
Supply only submersible stainless steel running sleeves (off size) suitable for 7.5 HP to 15 HP, including taking down old unserviceable SS sleeves, complete all as specified and directed by Engineer-in-Charge.
Supply only submersible impellor locking keys stainless steel (off size) suitable for 7.5 HP to 15 HP, including taking down old unserviceable locking keys, complete all as specified and directed by Engineer-in-Charge.
Supply only submiersible pump set shaft upto 16mm to 25.40 mm dia of any capacity suitable for 7.5 HP to 15 HP, including taking down old unserviceable shaft, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of submersible flat cable stranded copper conductor PVC insulated PVC sheathed 3 core flat size, 4 Sqmm, 1100 volts, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of DOL starter Three phase , over load relay, contactor capacitor, voltmeter, ammeter ON and OFF push button including fixing arrangement suitable for 5 HP submersible pump, complete all as specified and directed by Engineer-in-Charge. Make: L&T/Bentex/Seimens.
Supply and fixing in replacement of star delta starter with digital voltmeter and ammeter, 3 phase indicator lamp fully automatic for 7.5 HP to 15HP motor, complete all as specified and directed by Engineer-in-Charge. Make : L&T, Legrand & C&S.
Water Testing, Collecting the sample of water at Pump house and testing of water for iron, PH value, TDS, colour, Total Hardness, chloride, Chlorine, fluoride, Coliform, arsinic test and submitting the test report from reputed laboratory, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of 6 Sqmm cable connection kit (Male Female) for taxi track, complete all as specified and directed by Engineer-in-Charge.
Supply only Hypochlorous Acid net wt 38 kg, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed HDPE container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 % and delivered at STP, complete all as specified and directed by Engineer-in-Charge.
Supply only Bleaching powder suitable for disinfection, complete all as specified and directed by Engineer-in-Charge.
Supply only Swimming Pool Alum Powder of approved Make by Accepting Officer, complete all as specified and directed by Engineer-in-Charge.
Supply only TCCA of approved Make by Accepting Officer, complete all as specified and directed by Engineer-in-Charge.
Supply only Swimming Pool Aigiecide in 05 Liters Can of approved Make, complete all as specified and directed by Engineer-in-Charge.
Comprehensive Maintenance of RO plant of capacity 500 LPD servicing including changing of primary filter, secondary Filter, sediment filter, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Sand filter media of RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Carbon Media of RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement housing of carbon/ sediment filter of RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Anti scalent chemical of RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Membranes 402 INDROMATIL ION EXCHANGE of RO plant, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Solenoid Valve of RO plant, complete all as specified and directed by Engineer-in-Charge.
Pumping out sewage water from the existing sumps/tanks of STPs (MBBR technology) with the help of Non clogging of pump any kind capacity of pump set not less than 1500 LPM capacity 10HP/15 HP (Minimum) along with tanking out mud/ solid sludge from the tank complete from soild sepration chamber, aeration chamber and despose whole sludge to faraway areas from public places including cleaning of sump completely. So as to vacate the sumps to enable the repair of the main non clogging pump sets installed in the STPs, complete all as specified and directed by Engineer-in-Charge. Note :- (a) Pumping shall be continued till the main pumps installed in STPs sump is cleared for carrying out repair work. (b) Delivery pipe should be connected and the sewage water shall be thrown in the manhole of out side the fencing /wall of STPs towards the main gravity dropping main hole. (c) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative. (d) Necessary man power to operate the pump set are deemed to be included in the rate. (e) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set. (f) Rate included for transportation of pump set to site/back.
Material & Labour in PP floating media to top up for bio reactors, complete all as specified and directed by Engineer-in-Charge.
Carry out water testing of bacterial, chemical and biological analysis of sewage water treated water from NABL accredited Govt approved lab for following parameters and submission of test reports all as directed. Location : CGRA Inaz (a) PH (b) Chemical Oxygen demand/COD (c) Biological Oxygen Demant/BOD (d) Total Suspended solids (e) Oil and grease (f) TKN (g) Total Coliform (h) Organism MPN (k) Dissolved Oxygen Note: Every Quarterly water testing shall be carried out as per CA Qty in period of contract all as directed without fail else recovery will be made at Rs 15000/- per test for execution of item and for non-submission of Test Report.
Dismantling monoblock pump set centrifugal type of cap 3/5 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site incl. electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate)
Supply only ball bearing suitable for 3/5 HP of monoblock/pump set motor, complete all as specified and directed by Engineer-in-Charge.
Dismantling/taking down Sewage submersible pump set of cap 5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enameled copper wire as per existing gauge re-fixing the same at site including. Electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. Note : Cost of dismantling/taking down of bore well pump and re-fixing deemed to be included in quoted rate.
Supply in replacement of bush/bearing (gun metal) of suitable size for 5 HP for the Sewage submersible motor, complete all as specified and directed by Engineer-in-Charge.
Taking down air blower of Air blowers with working pressure 0.3 Kg/cm2 alongwith motor of capacity 5 HP with blower pipe of size 3", from the existing position after disconnecting all electrical connection and transportation to workshop for repair for un-serviceable parts complete and removing the defective parts, repair the air blower throughly including machine work and re-assembling the air blower and commssioning testing on full load, complete all as specified and directed by Engineer-in-Charge. Note:- New spares will be measured and paid separately under respective item.
Material & Labour for taking out & servicing of existing unserviceable Air Blower (of any Make) of capacity 5 HP pressure 0.3 Kg/cm2 with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer-in- charge. Note- (i) Spare part required for replacement shall be measured and paid separetly under relevent items (ii) Replacement of Oil seal, locking arrangement of pully, gland packing with oil and greasing shall be deemed to be including in the quoted rate of this item.
Supply & Fixing in replacement of "V" Belt (SPA 1250) unserviceable /worm-out 'V' belt of air blower etc, complete all as specified and directed by Engineer-in-Charge. Makes:- Fenner/Dunlop/Nerlon/Super flix/Ecodrive.
Supply & Fixing in replacement of Gear oil 90 EP, Pressure Gear Oil etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of air-filter for blower suitable size for existing air-filter etc, complete all as specified and directed by Engineer-in-Charge.
Supply only Grease 30K, for using ensure protection of metal surfaces extending bearings, Hinges etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of round strand galvanised iron steel wire rope dia & 8mm and connected clamp nut bolts fixed etc, including taking down old unsv cable, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of isolating transformer 45W, 6.6 Amps for runway light, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified and directed by Engineer-in-Charge.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces inclduing painting, complete all as specified and directed by Engineer-in-Charge.
Disconnecting electric connection and taking down old unserviceable MCB DBs, of any capacity including MCBs, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible 1.5 Sqmm cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors in exsisting conduit/ Provision of PVC casing capping/ PVC conduit as per site requirment size conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed cassing capping, modular cover-plates and frame complete all as specified in IS: 732- 1989 and directed. NOTE: Circuit wire from DB to switch boards shall be included in quoted rate. Note (i) Exsisting Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of exsistng size is to be replace and rate are deemed to be inlcuded in quoted rate. (iii) PVC cassing capping measured and paid under relevent Item.
One light / fan/exhaust point controlled by one, one way switch
One light point controlled by 2, Two way switch
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board.
One bell point controlled by one, one way switch
Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible 2.5 Sqmm cable, conforming to IS: 694-1990, having multi drawn thin strands of electrolytic copper conductors, conforming to IS: 8130-1984 and insulation conforming to IS: 5831-1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed casing capping/ PVC conduit conforming to IS: 537 (Part 3)-1983, colour-coded as specified in IS: 11353- 1985, and including modular cover plates, complete all as specified in IS: 732- 1989 and directed. Note:- (i) Exsisting Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of exsistng size is to be replace and rate are deemed to be inlcuded in quoted rate.
One 16 Amp socket outlet,independent, with cables 2.5 mm² size
Supply and fixing in replacement of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of modular type 6 Amp bell-push conforming to IS: 8884-1978 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Bell multi music type 230 Volt, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of 6 Amp, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Modular switch 2 way 6 Amp, 1 module, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC Modular surface box,complete all as specified and directed by Engineer-in-Charge. of following size:-
1 or 2 Module of size 85 x 85 mm
3 Module of size 85 x 115 mm
4 Module of size 85 x 145 mm
6 Module of size 132 x 135 mm
Supply and fixing in replacement of Modular cover plate with frame, complete all as specified and directed by Engineer-in-Charge. of following size:-
1 or 2 Module of size 85 x 85 mm
3 Module of size 85 x 115 mm
4 Module of size 85 x 145 mm
6 Module of size 132 x 135 mm
Supply and fixing in replacement switch piano flush button, 240 volts, 6 Amps, single pole, one way (ISI marked), complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Socket outlet 2 in 1, 3 pin, 5/6 Amp flush type (ISI marked), complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Socket outlet 3 pin, 16 Amp, flush type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of switch piano flush button 230 V, 16 Amps, Single pole, one way ISI marked, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 16 way type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, complete all as specified and directed by Engineer-in-Charge.
Suppy and fixing of rating 240V, 10KA 'C' curve Miniature Circuit Breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
MCB 6 to 32 Amps, single pole
MCB 32 Amps, double Pole / SPN
MCB 40 to 63 Amps, double Pole / SPN
Supply and fixing of 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
MCB, TP 25 to 63 Amps
MCB, TPN/FP 16 to 32 Amps
Material & Labour for submain wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in exsisting conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, complete all as specified and directed by Engineer-in-Charge. NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length.
2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire
Supply and fixing in replacement of casing capping of 25 x 12 mm size, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of casing capping of 32 x16 mm size, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of 6 W LED spot light with multiple beam tilting angles, no UV radiation and dimmable ballast, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of square shape slim recessed mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of 80 Wattt LED bay light made of PDC aluminium housing with direct modular IP Lens, potted driver, 10 KV SPD, IP66 and with system efficay of 12lm/ including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engineer-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge.
Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of BLDC fan Printed circuit board(PCB) assembly with remote for 1200 mm sweep suitable for existing, complete all as specified and directed by Engineer-in-Charge.
Opening up ceiling fan of any make and any sweep for overhauling such as cleaning the rotor & the stator, overhauling, lubricating with fresh oil/ graese, re-assembling for proper running complete all as specified including re-hanging in position & connecting up, testing and commissioning, complete all as specified and directed by Engineer-in-Charge. NOTE:- Any unserviceable/burnout parts replaced shall be measured and paid separately under respective item here-in-after. However quoted rates shall be deemed to include for rectification of any defect in the fan, if any to make the fan functional.
Supply only capacitor 2.5/3.15 mfd AC 230 volts for ceiling fans 1200/1400 mm sweep and any make, including taking down old unserviceable capacitor, complete all as specified and directed by Engineer-in-Charge.
Supply only capacitor 4 mfd suitable for exhaust fans 250/300 mm sweep, including taking down old unserviceable capacitor, complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing of suitable for ceiling fan sweep 1200 mm, including taking down old unserviceable ball bearing, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparing the surface of body/blades of ceiling fan of any sweep and make and with & incluidng one coat of spray painting with synthetic encamel white paint and writing the MES No maker's Sl No etc with sythentic enamel bleack paint 1.5cm high letters, complete all as specified and directed by Engineer-in-Charge.
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ, complete all as specified and directed by Engineer-in-Charge. Note- worn out parts shall be measured as separately.
Supply & Fixing spare parts of Geyser and including taking down old unserviceable Part.
Supply Only Heating element 1.5 KW with rubber gasket.
Supply Only Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
Supply Only Hot/Cold water connection pipe 450 mm length.
Supply Only Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia
Supply Only Indication lamp red and green suitable for geyser as required
16 Amps top plug suitable as per existing socket
Material & Labour for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, refixing the front cover of indoor unit. Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressureized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection, complete all as specified and directed by Engineer-in-Charge. Note:- Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule.
Material & Labour for detecting the cause of leakage in any type/capacity of 1.5/2 ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning, complete all as specified and directed by Engineer-in-Charge. Notes :-(i) Dismantling of unserviceable compressor, cost of refrigarent gas and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates.
Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity, Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of over load protector suitable range and capacity
Supply and fixing in replacement of Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply
Supply and fixing in replacement of capacitor of 2.5 mfd suitable for blower fan motor of 1.5/2.0 ton AC
Supply and fixing in replacement of thermostat switch of suitable for 1.5/2.0 ton AC
Supply and fixing in replacement of Contactor relay of suitable for 1.5/2.0 ton AC
Supply and fixing in replacement of Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete
Supply and fixing in replacement of condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete. Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
Supply and fixing in replacement of Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete
Supply and fixing in replacement of PVC fan blower assembly for 1.5 /2TR split AC's any make
Supply & Fixing in replacement of Printed circuit board(PCB) with suitable for non inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
Supply and fixing in replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter, complete all as specified and directed by Engineer-in-Charge. for split type AC's of the following capacity
1.5 ton capacity
2.0 ton capacity
Supply and fixing in replacement of codenser fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of Printed circuit board(PCB) with hand set of indoor, outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Printed circuit board(PCB) with hand set of indoor, outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of outdoor condencer unit of copper with 2 run of copper pipe of out door unit of split type AC 1.5/2.0 TR, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of swing motor 230 Volt for 1.5/2.0 Ton indoor unit of split AC, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Blade set of fan motor of out door unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Blade set of fan motor of out door unit, made out of PVC Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of copper tubing of size 3/8" suitable for split AC with nitrile self adheive foam wrapped with PVC insulation all around the pipe line, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of copper tubing of size 5/8" suitable for split AC with nitrile self adheive foam wrapped with PVC insulation all around the pipe line, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of flexible PVC pipe for condense water outlet for Split AC as per existing, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for charging of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instrcutions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for charging of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instrcutions suitable for split air conditioner cap 2.0 ton after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of remote for split AC 1.5/2 Ton unit suitable for existing make and model including with battery, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of outdoor unit stand of metal inclduing fixing accessories such as nut bolt washers and fastner for 1.5/2 Ton outdoor unit, complete all as specified and directed by Engineer-in-Charge.
Material and labour for servicing/cleaning of water cooler of storage capacity/ nominal cooling capacity(Ltrs/hr) 80/40 & 120/60 litres with the use of antiscaling agent for internal steel water tank ,outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush ,cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipments, cleaning of fins and tubes of condenser,repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler, complete all as specified and directed by Engineer-in-Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor and replacement with new electric motor, single phase 230V of water cooler 40ltrs/hrs with condenser fan blade, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of following items of water cooler
Thermostate for water cooler capacity 40/80 ltr/hrs.
Push type Bib tap Cast copper alloy 15 mm Push type chromium plated.
PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15 mm dia GI Pipe.
Supply and fixing in replacement of over load protector suitable range and capacity for Refrigerator
Material and labour for carrying out repair /maintenance/ servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Refigerator in good working condition, complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items.
Material and labour for maintenance of Refrigerator any capacity with replacement of old/unsv spare parts as under including testing on load, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of condensor suitable for Refigerator of 195/ 250/ 300 ltr cap
Supply and fixing in replacement of cooling effect tranmitting fan motor suitable for Refigerator of 195/ 250 / 300 ltr cap
Supply and fixing in replacement of Compressor Relay suitable for Refigerator of 195/250 / 300 ltr cap or as per existing Make KCL/Rentrol/Indofos
Supply and fixing in replacement of thermostat suitable for Refigerator of 195/250 / 300 ltr cap
Supply and fixing in replacement of Compressor suitable for Refigerator of 195 / 300 ltr cap or as per existing
Supply and fixing in replacement of frost free fan motor suitable for Refigerator of 195 / 300 ltr cap or as per existing
Supply and fixing in replacement of defrost timer suitable for Refigerator of 195 / 300 ltr cap or as per existing
Material & Labour for charging of refrigerant R-134a gas to Refrigerator for the following capacities as per existing /manufacturer instrcutions after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge.
Refrigerator cap 230/250 Ltrs
Earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, including taking down old unserviceable Earthing, complete all as specified and directed by Engineer-in-Charge.
Vijay Construction Co (BID ID -3289789)
AADESH CONSTRUCTION (BID ID -3289799)
shree chamunda enterprise (BID ID -3294592)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .