Executive Engineer
Executive Engineer HP PWD Division Tanda
Providing and fixing, Supply and installation of Medical Gas pipe line system of upgradation of vacuum system work for medical gas pipe line including maintenance for five year (Deposit Work).
2020_PWD_43415_10
PWD-Civil-11175-11205-Tanda
Open Tender
Civil Works
Item Rate
90 days
Tanda
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,500
Executive Engineer HP PWD Divison Tanda
₹53,550
12 Apr 2021
1 Feb 2021
12 Feb 2021
1 Feb 2021
11 Feb 2021
1 Feb 2021
Amount
Providing, Fixing, Supply & Installation of Imported LINE LOCKABLE ISOLATION VALVES WITH STUB PIPES: It should fully complies and meets with the requirements of the UK DOH Health Technical Memorandum 02-01 (HTM 02-01) standards only. It shall be duly CE marked to the Medical Device Directive 93/42/EEC under the auspices of notified body no. and under this directive, med gas products are classified as Class IIb Medical Devices. It shall be provided with a copy of the certificate of origin from chamber of commerce. Line Isolation valves and should comprise full-bore ball valve complete with copper stub pipes for ease of installation. Valve - connected to the copper stub pipes by means of flat faced unions fitted with nitrile O-ring seals, allowing removal of the valve without the need to distort the pipe work. Stub pipes for valve up to 54 mm will be connected to the valve body using screwed connectors, while valve above this size will use flanged connectors. Valve - Brass body, end cap and stem, with a full – bore chrome plated brass ball. Valve - Operate from fully closed to fully open with a quarter turn of the handle. All line values - Supplied with a mechanism to enable the unit to be locked in the fully closed or fully open position. Supplied with copper stub pipes for ease of installation using inert gas jointing procedures. O-Ring Seals on the valve stub allow gas tight capping at a spur for further expression complete including maintenance for five year and carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing, Fixing, Supply & Installation of Imported 42 MM BALL VALVE --- LINE LOCKABLE ISOLATION VALVES WITH STUB PIPES
Providing, Fixing, Supply & Installation of Imported 54 MM BALL VALVE --- LINE LOCKABLE ISOLATION VALVES WITH STUB PIPES
Providing, Fixing, Supply & Installation of Imported 76 MM BALL VALVE --- LINE LOCKABLE ISOLATION VALVES WITH STUB PIPES
Providing, Fixing, Supply & Installation of Medical Grade BSI Kite Mark Certified Copper Pipes of BS EN 13348. Copper pipes must be inspected and duly Third Party Certified by Lloyd’s Registered Asia. Medical Grade Copper pipes manufactured from Phosphorous de-oxidized non-arsenical copper to BS:EN: 1412:1996 grade CW 024A ( Cu-DHP) manufactured to metric outside diameters and having mechanical properties in accordance with BS:EN: 13348, Degreasing of pipe shall be such that there is less than 20 mg/m2(0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS:EN:13348 complete including maintenance for five year and carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing, Fixing, Supply & Installation of Imported 76MM OD X 1.5MM THICK
Providing, Fixing, Supply & Installation of Imported 54MM OD X 1.2MM THICK
Providing, Fixing, Supply & Installation of Imported 42MM OD X 1.2MM THICK
Providing, Fixing, Supply & Installation of Imported 28MM OD X 1 MM THICK
Providing, Fixing, Supply & Installation of Imported Vacuum Pump : It should be Oil lubricated rotary vane vacuum pump, having each Pump Capacity of 3300 LPM with IEC Motor rating of minimum 7.5 HP @ 50 Hz. The motor rpm should not be more than 1500 @50 Hz & 1800 @60 Hz. Vacuum Pump Dimension should be (977 x 583 x 418 mm approx.). Weight of each pump should be 160 Kg. approx. Vacuum pump shall comprise of air cooled, oil lubricated rotary vane vacuum pumps suitable for both continuous and frequent start / stop operation at inlet vacuum vessels between 525mm Hg and 700 mm Hg. The ultimate vacuum of pump shall be 0.1 mbar with gas ballast valve closed. The Vacuum Pump should be air cooled and oil lubricated rotary vane vacuum pumps designed for use in the field of high quality vacuum. It should be a robust construction, reliable operation, highly resilient carbon composite fiber vanes, Gas ballast valve. The pump should be having a 4 barriers system that avoids any oil leaks by doubling the 2 lip seals. The use of shaft lip seals Pump vanes shall be lubricated by a fully re-circulated and filtered lubricant supply. Also Pump design should include a lubricant separation system integral to the pump exhaust box consisting of no less than four stages of internally installed lubricant and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, lubricant mist elimination, smoke elimination, synthetic lubricant baffle, and shall be capable of removing 99.9 percent of all lubricant and smoke particles from the exhaust gas stream. The unit should have extremely low vibration. The noise level of the pumps should not exceed 75dB(A). (1 working and 1 as stand by). Technical product data sheet with model number must be submitted for technical evaluation complete including maintenance for five year and carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing, Fixing, Supply & Installation of Imported Vacuum Filter (Bacteria Filter) of 105scfm – 3” Filter housing with drain flask: It fully complies and meets with requirements of UK HTM medical standards. It should have BS 3928 sodium flame test certificate based on requirements of HTM standards. The bacteria filter should be designed for critical application involving removal of dry and wet dust, particulars, oil aerosol and water droplest, high efficiency glass fiber, fieece media from suction side of vacuum pump system. It should have efficiency of at least 99.995% when tested by sodium flame test and that should be according to BS 3928:1969. The Vacuum filtration efficiency should be in excess of 99.9999% as per HTM0201 & AS 2896 standards. The high efficiency medical grade filter element should have custom engineered filter media and deep pleat element technology provides minimal pressure loss and filtration efficiencies. It should have advanced filtration technology for Low pressure loss borosilicate glass microfiber-media and open cell reticulated foam pre-filtration layer captures particulates, bacteria and liquid aerosols reducing energy consumption and overall system costs. It should have corrosion protection Internal and external electrophoretic painting followed by a tough exterior polyester powder coating. It should have easily removable sterilisable drain flask and differential pressure monitor gauge. It should have push fit element design for quick and easy maintenance with unique push fit element design. It should have element end cap color black. It should have maximum temperature 60 degree centigrade (140 degree F). It should have element of E31140MV grade. It should have pipe size connection 1” = 105scfm and 180nm3/hr FAA. It should have pressure loss clean & dry = < 3kPa (30m/bar/0.44psig). It should have maximum working pressure 0.5barg(7psig. It should have manual drain valves and 250ml sterilisable glass drain flasks. Technical product data sheet with model number must be submitted for technical evaluation complete including maintenance for five year and carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
Providing, Fixing, Supply & Installation of Vacuum Receiver Tank of 3000ltrs of water capacity with Pressure Gaugecomplete including maintenance for five year and carriage of materials within all leads, lifts and other incidentals as per approved drawing, design and as directed by the Engineer-in-Charge.
j k m consultant
Medical Products Service
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .