| Sl No | Description | Qty | Unit | Sunwin Energy and Infra Pvt Ltd L2 | Sunwin Infratech Private Limited L1 | SWASTIK ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 0.00SCHEDULE OF WORKS | ||||||
| 1.00 | 1. Scope of work. Supply & Constr of UG Amn Pit (RCC framed structure and PCC block masonry), Plinth protection, PCC block masonry drainage and Retaining wall with RR masonry as per drgs and specifications as Appx 'A'. Store list att as per Annx-I.
(a) Dimensions of Bkr.
(i) UG Amn Pit : 5.70m x 5.70 mtr (Internal)
(ii) Height : 4.2m (internal)
(iii) Platform : 3.50m x 2.00m x 1.20m
(iv) RCC Retaining wall : 5.40m high
(v) Drainage with PCC block masonry all around the bldg
(vi) 900mm wide Plinth protection all aroung the bldg | 2 | Nos | 38,56,200 ₹77,12,400 | 38,17,500 ₹76,35,000 Lowest | 39,00,000 ₹78,00,000 |
| 2.00 | (a) For Bldg portion :- Excavating over areas in any description, getting out in any type of soil all as specified and directed. | 2,430 | Cum | 1,210 ₹29,40,300 Lowest | 1,210 ₹29,40,300 Lowest | 1,215 ₹29,52,450 |
| 3.00 | (b) For Pathway :-Excavating over areas in any description, getting out in any type of soil all as specified and directed. | 45 | Cum | 920 ₹41,400 Lowest | 920 ₹41,400 Lowest | 925 ₹41,625 |
| 4.00 | (c) For Platform wall :- Excavating over areas in any description, getting out in any type of soil all as specified and directed. | 15 | Cum | 905 ₹13,575 | 900 ₹13,500 Lowest | 905 ₹13,575 |
| 5.00 | (d) For Retaining wall :- Excavating over areas in any description, getting out in any type of soil all as specified and directed. | 172.66 | Cum | 1,202 ₹2,07,532.51 | 1,200 ₹2,07,187.2 Lowest | 1,215 ₹2,09,777.04 |
| 6.00 | (e) For Drainage :- Excavating over areas in any description, getting out in any type of soil all as specified and directed. | 33.66 | Cum | 905 ₹30,462.3 | 900 ₹30,294 Lowest | 915 ₹30,798.9 |
| 7.00 | (f) Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed. | 2,696.32 | Cum | 605 ₹16,31,271.18 | 600 ₹16,17,789.6 Lowest | 625 ₹16,85,197.5 |
| 8.00 | Supply & Constr of pathway. Detailed technical specifications att as per Appx 'A' and list of constr mtrl as per Annx - II. | 300 | Sqm | 3,610 ₹10,83,000 | 3,600 ₹10,80,000 Lowest | 3,700 ₹11,10,000 |
| 9.00 | 5 KVA Petrol driven generating set, air cooled, single phase. Technical specification as per Appx 'C' and store list as per Annx-III. | 2 | Nos | 1,30,000 ₹2,60,000 | 1,29,765 ₹2,59,530 Lowest | 1,35,000 ₹2,70,000 |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
18 Aug 2025, 6:00 pmClosed
Col R Vamshi Krishnan
237 Engineer Regiment Military Station Likabali
Supply and Constr of 02 x UG Amn Pit
2025_ARMY_725461_1
OT/EC/3/56/2025-26/2409(S and C)(COW)
Open Tender
Civil Works
Works
180 days
MILITARY STATION SEGONG
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
SBI Likabali
₹2.4 L
237 Engineer Regiment Military Station Likabali
2 Sept 2025
11 Aug 2025
19 Aug 2025
11 Aug 2025
18 Aug 2025
12 Aug 2025
14 Aug 2025
Amount
1. Scope of work. Supply & Constr of UG Amn Pit (RCC framed structure and PCC block masonry), Plinth protection, PCC block masonry drainage and Retaining wall with RR masonry as per drgs and specifications as Appx 'A'. Store list att as per Annx-I. (a) Dimensions of Bkr. (i) UG Amn Pit : 5.70m x 5.70 mtr (Internal) (ii) Height : 4.2m (internal) (iii) Platform : 3.50m x 2.00m x 1.20m (iv) RCC Retaining wall : 5.40m high (v) Drainage with PCC block masonry all around the bldg (vi) 900mm wide Plinth protection all aroung the bldg
(a) For Bldg portion :- Excavating over areas in any description, getting out in any type of soil all as specified and directed.
(b) For Pathway :-Excavating over areas in any description, getting out in any type of soil all as specified and directed.
(c) For Platform wall :- Excavating over areas in any description, getting out in any type of soil all as specified and directed.
(d) For Retaining wall :- Excavating over areas in any description, getting out in any type of soil all as specified and directed.
(e) For Drainage :- Excavating over areas in any description, getting out in any type of soil all as specified and directed.
(f) Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.
Supply & Constr of pathway. Detailed technical specifications att as per Appx 'A' and list of constr mtrl as per Annx - II.
5 KVA Petrol driven generating set, air cooled, single phase. Technical specification as per Appx 'C' and store list as per Annx-III.
Sunwin Energy and Infra Pvt Ltd (BID ID -3396764)
SWASTIK ENTERPRISE (BID ID -3396773)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .