| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Financially and technically Qualify |
| 2 | Accepted-Technical 55 2 LOWER NEHRU GRAM NEHRUGRAM LOWER NEHRUGRAM DEHRADUN UTTARAKHAND 248001 | DEHRADUN | UTTARAKHAND | 248001 | Accepted-Technical Financially and technically Qualify |
| 3 | Not Admitted-PreQual/Technical M S ALAKNANDA ENTERPRISES VILLAGE MADHI CHAURAS DISTRICT TEHRI GARHWAL | TEHRI GARHWAL | UTTARAKHAND | 249001 | Not Admitted-PreQual/Technical Others-Not meet required TQR and FQR |
| 4 | Not Admitted-PreQual/Technical B 43 CIVIL LINES 1ST FLOOR NAYAPURA KOTA RAJASTHAN 324001 UDYAM RJ 24 0019224 08ABKPA3675N1Z9 R M | KOTA | RAJASTHAN | 324001 | Not Admitted-PreQual/Technical Others-Not meet required TQR and FQR |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
25 May 2026, 3:00 pmClosed
Chief Engineer O and M Garhwal Zone Roorkee
Chief Engineer O and M Garhwal Zone PTCUL 26 Civil lines Roorkee
Annual Maintenance Contract for 66KV Substation Kothiyalsain, Joshimath and 66KV Transmission lines from Karanprayag to Joshimath
2026_PTCUX_94681_1
CE/GZR-06/2026-27
Open Tender
Electrical Works
Item Wise
365 days
Srinagar Garhwal
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,360
SE Oand M Transmission Circle Roorkee
₹1.2 L
27 Jun 2026
25 Apr 2026
26 May 2026
25 Apr 2026
25 May 2026
25 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | (A-1) 66 KV Substation Kothiyalsain Assistance inDaily Routine works at 66 KV Substation (Kothiyalsain).
a) Uprooting of bushes from 66 kV switchyard and control room building premises, Grass cutting in switchyard &control room building area by cutting/ uprooting bushes, grass, weeds, small trees and removal of all foreign material and throwing away from substation premises Note: All the above work shall be strictly carried out as per instruction of Engineer Incharge | 300 | Operations | - | - |
| 2 | Assistance in Shutdown and other works of 66KV Substation (Kothiyalsain) which may include following works.
i) i) Maintenance of switchyard equipments of all the bays.
ii) Replacement/Tightening of jumpers, droppers, runner, clamps, connectors etc.
iii) Tightening of 66KV &33 KV Busbar (if required).
iv) Replacement/Tightening of Jaw, blade of isolators.
v) Refilling of Transformer oil on CT, CVT, PT and Transformers.
vi) Cleaning of porcelain part of switchyard equipments
vii) Cleaning of Trenches and drainage system at Substation premises and switchyard.
viii) Replacement/ Repairing of control cables, electrical cables etc.
ix) Any other maintenance work as directed by Engineer In-charge. | 50 | Operations | - | - |
| 3 | (A-2) 66 KV Karanprayag- Kothiyalsain Line Assistance in Routine maintenance of 66 KV Transmission Line by carrying out following activities. (a) Regular Patrolling, preparation of patrolling report as per prescribed format, close visual inspection of line route i.e. clearance of conductor, position of trees/ hindrances, condition of towers, tower accessories, conductors, conductor accessories, flash points, red hot points etc. as per the direction of Engineer In-charge.
b) Lopping - Chopping and pruning of trees branches, bushes and vegetation required for maintaining proper clearance of line corridor as per direction of Engineer In-charge.
c) Cutting and felling of trees imposing danger to line towers & conductors as per the direction of Engineer In-charge.
d) Tightening/ replacement of tower members and tower accessories as per the direction of Engineer In-charge.
e) General tightening/ replacement of tower members and tower accessories including fixing of missing tower parts and tower accessories as per the direction of Engineer In-charge.
f) General checking of tower legs, earthing and fixing of any defects observed as per the direction of Engineer In-charge.
g) Replacement of broken/ damaged jumper, conductor and discs.
h) Replacement of damaged/ broken earthwire with all its accessories.
i) Any other routine preventive maintenance works directed by Engineer In-charge. | 150 | Operations | - | - |
| 4 | (B-1) 66 KV Substation Joshimath Assistance inDaily Routine works at 66 KV Substation (Joshimath).
a) Uprooting of bushes from 66 kV switchyard and control room building premises, Grass cutting in switchyard &control room building area by cutting/ uprooting bushes, grass, weeds, small trees and removal of all foreign material and throwing away from substation premises Note: All the above work shall be strictly carried out as per instruction of Engineer Incharge | 300 | Operations | - | - |
| 5 | Assistance in Shutdown and other works of 66KV Substation (Joshimath) which may include following works. i) Maintenance of switchyard equipments of all the bays.
ii) Replacement/Tightening of jumpers, droppers, runner, clamps, connectors etc.
iii) Tightening of 66KV &33 KV Busbar (if required).
iv) Replacement/Tightening of Jaw, blade of isolators.
v) Refilling of Transformer oil on CT, CVT, PT and Transformers.
vi) Cleaning of porcelain part of switchyard equipments
vii) Cleaning of Trenches and drainage system at Substation premises and switchyard.
viii) Replacement/ Repairing of control cables, electrical cables etc.
ix) Any other maintenance work as directed by Engineer In-charge. | 50 | Operations | - | - |
| 6 | (B-2)66 KV Kothiyalsain – Joshimath Line Assistance in Routine maintenance of 66 KV Transmission Line by carrying out following activities.
a) Regular Patrolling, preparation of patrolling report as per prescribed format, close visual inspection of line route i.e. clearance of conductor, position of trees/ hindrances, condition of towers, tower accessories, conductors, conductor accessories, flash points, red hot points etc. as per the direction of Engineer In-charge.
b) Lopping - Chopping and pruning of trees branches, bushes and vegetation required for maintaining proper clearance of line corridor as per direction of Engineer In-charge.
c) Cutting and felling of trees imposing danger to line towers & conductors as per the direction of Engineer In-charge.
d) Tightening/ replacement of tower members and tower accessories as per the direction of Engineer In-charge.
e) General tightening/ replacement of tower members and tower accessories including fixing of missing tower parts and tower accessories as per the direction of Engineer In-charge.
f) General checking of tower legs, earthing and fixing of any defects observed as per the direction of Engineer In-charge.
g) Replacement of broken/ damaged jumper, conductor and discs.
h) Replacement of damaged/ broken earthwire with all its accessories.
i) Any other routine preventive maintenance works directed by Engineer In-charge. | 150 | Operations | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.11 MB
BOQ_112020.xls
BOQ • 0.24 MB
TD.pdf
Tender Documents • 1.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .