| 1 | 1₹16.1 LAccepted-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | 1 | Accepted-AOC Lowest and eligible bidder | |
| 2 | 2₹17.2 L+₹1.0 L (6.40%)Rejected-Finance 43 MANAK BHAVAN FIRST FLOOR GUMANPURA KOTA 324 007 RAJASTHAN | KOTA | KOTA | RAJASTHAN | 324007 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹17.7 L+₹1.6 L (9.70%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹18.8 L+₹2.7 L (16.8%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹19.3 L+₹3.2 L (19.8%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹17.8 L
EMD Value
₹35,600
Closing Date
11 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Kota
Opp Circuit House, Station Road, Kota - 324001
REPAIR/MAINTENANCE OF LT ELECTRIFICATION ALONGWITH CONNECTED ITEMS IN NORTHERN AND CENTRAL SECTOR AT MIL STN KOTA
2021_MES_415573_1
8489/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Kota
Class E category b(i)
8 documents required · 8 mandatory
₹500
GE Kota
₹35,600
Yes
4 Mar 2021
23 Jan 2021
13 Feb 2021
23 Jan 2021
11 Feb 2021
6 Feb 2021
25 Jan 2021 - 30 Jan 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth and getting out in hard/dense soil for laying of under ground cables/pipes and foundation etc, complete all as specified and directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removing excavated material (soil) n exc. 50m distance and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
M&L dry clean Sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. (Depth of sand shall be measured after punning).
M&L for pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), class 10, laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling of cross arms of MS channel or angle sections etc complete and setting aside for re-use within 50m, complete all as specified and directed.
M&L for Pin type, porcelain, vitreous, white , borwn or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 150 mm height,150 mm dia including dismantling of old unserviceable insulator, complete all as specified and directed.
M&L for insulator disc type porcelain, vitreous, 100 mm high and 115 mm dia ball and socket type, white, brown or green, two in series assembly for tension with tension clamps for conductor, working pressure 1100 volts, including dismantling of old unserviceable insulator, complete all as specified and directed.
Supply, straining, streching and fixing ACSR conductor on HT/LT poles or on existing poles including binding and jointing to conductor/ insulator with and including suitable size of copper binding wire or aluminium tape and testing including dismantling of ACSR conductors from the poles, complete all as specified and directed.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth lead wire of 4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 15 mm bore light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI wire of 4 mm dia for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and complete all as specified and directed. (Earth lead wire and GI protection pipe beyond 7.50 m shall be measured and paid separately)
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 40 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 25x4 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and complete all as specified and directed. (Earth lead strip and GI protection pipe beyond 7.50 m shall be measured and paid separately)
S&F earth lead wire 4 mm dia, made of galvanised iron, fixed to wall or pole, complete all as specified and directed.
S&F galvanised iron earth strip of size 25x4 mm, fixed to wall or pole, complete all as specified and directed.
S&F in repairs 50 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
S&F in repairs 80 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
S&F in repairs 100 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
Supply and laying in replacement, LT 1100 volts grade UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe all as specified and directed of following sizes:- Note :- Rate deemed to be inclusive of connecting up with control gear including cable glands and cable lugs. 16 Sq mm 4 core
25 Sq mm 3.5 core
50 Sq mm 3.5 core
70 Sq mm 3.5 core
95 Sq mm 3.5 core
120 Sq mm 3.5 core
150 Sq mm 3.5 core
185 Sq mm 3.5 core
Taking down old unserviceable PCC pole and Supply, transporting, erection and fixing steel tubular swaged pole, 9.00 metres long, type 410 SP-31, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:3:6 type C2, using 40 mm graded stone aggregate and PCC 1:2:4 type B1, using 20 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting the pole with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with red post office box colour (300mm wide each) synthetic enamelled paint at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete, complete all as specified and directed.
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles of 9 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground and pasting 100 mm wide reflective red strickers in 3 lines around the pole, complete all as specified and directed.
S&F PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 5 line, complete all as specified and directed.
S&F PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 4 line, complete all as specified and directed.
S&F PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 3 line, complete all as specified and directed.
M&L for Cutting of bushes including trimming of tree branches and cleaning the area around the sub station premises including two pole/four pole structures, complete all as specified and directed.
M&L trimming/cutting of tree branches to provide proper clerance around existing LT over head line up to 5 lines with clearance of 3mtr on both the sides from center of OH line all as per technical requirement including removing of cut tree branches from site and depositing at one place for burning/removing, complete all as specified and directed.
Restretching of existing aluminium conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminium tape/binding wire connectors, PG clamps, jumpers etc, complete all as specified and directed for any size of ACSR conductor. Note:- Each ACSR conductor in a circuit will be measured & paid sepretely.
S&F in replacement MCCB, 415 Volts, 400 Amps, 04 pole rupturing capacity 36 KA, with adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
S&F in replacement MCCB, 415 Volts, 250 Amps, 04 pole rupturing capacity 36 KA, with adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
S&F in replacement MCCB, 415 Volts, 200 Amps, 04 pole rupturing capacity 36 KA, with adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
S&F in replacement MCCB, 415 Volts, 160 Amps, 03 pole rupturing capacity 25 KA, with adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
S&F in replacement MCCB, 415 Volts, 100 Amps, 03 pole rupturing capacity 25 KA, with adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
S&F in replacement MCCB, 415 Volts, 63 Amps, 03 pole rupturing capacity 10 KA, with adjustable thermal and adjustable magnetic settings, complete all as specified and directed.
Supply only electrical insulating tape roll of length 25 metre and width 20 mm having high performance strength and good adhesive characteristics, complete all as specified and directed.
Supply and fixing 72 watt energy saving long life versatile roadway luminaire with pressure die-cast aluminium housing and toughened glass cover with IP 66 protection, with high power LED as light source including electronic driver and all accessories, complete all as specified and directed including disconnecting and taking down existing street light fitting of any type.
Taking down old unserviceable/rusted GI pipe bracket on pole/building and S&F 32 mm bore light grade GI pipe bracket, 1.30 m long, bent to shape as required, fixed on pole/building with and including suitable mild steel flat iron clamps with required, nuts, bolts and washers, complete all as specified and directed.
S&F PVC insulated 1.50 Sqmm, 3 core, multistranded copper conductor cable, unsheathed, 1100 volts grade, drawn through existing conduit / casing capping concealed or on surface/pole/wall including taking down existing unserviceable wire, complete all as specified and directed.
S&F in repair terminal box made of PVC Box of size 200x160x98mm, fix on pole by means of mild steel clamps with bolt and nuts, provn for cable entry for incoming and outgoing including 01 No. MCB 6-32 Amps and one No. 4 way connector, making necessary connections, duly fixed with and including cable glands threaded type IP66/67 made of polyamide with lock nut, complete all as specified and directed.
S&F in replacement bus bar chamber, 4 pole, factory made using CRCA sheet steel of 3.15 mm thickness and epoxy powder coated and ETP grade copper and dull tin plated busbar sections incuding dough moulding compound (DMC) busbar support of protection class IP - 31, standard conformity to IEC-60439/IS-8623, 200 Amps current rating capacity, 440 volts, 50 Hz, short circuit withstand capacity 25 KA in 01 sec including 08 Nos outgoing, complete all as specified and directed.
Supply, installing, commissioning and testing outdoor type feeder pillar box factory made (CPRI approved manufacturer), structure fabricated from 3.15 mm thick CRCA sheet, compartmentalized design of suitable size with opening from front and back including mild steel channel frame of ISMC 75 at the base of panel only for grouting purpose, and grouted in PCC 1:2:4 type B-1 using 20mm graded stone aggregate. The panel shall be dust & vermin proof by providing good quality gasket on doors removal covers, gland plates etc including all internal connections with 4 Nos heat shrink insulated aluminum bus bar of 400 ampere rating. The sheet metal work of the panel shall have powder coated finish internally and externally. The panel shutter / doors shall be provided with detatchable & flush type hinges including flush cylindrical locks. Provision for cable entry shall be from either side. All joints and connection shall be done by galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided and complete with the following accessories: -
Item No. 38.00 Contd..... NOTES:- i) Platform for panel with PCC 1:4:8 type D-2 with 40 mm graded stone aggregate foundation of 15 Cm thickness and brick wrick work with pulverised fuel ash bricks in CM 1:6 with 15 mm thick rendering in CM 1:4 shall be provided. Height of platform shall be 45 cm from the nearest road level and top of platform shall be provided with 100 mm thick PCC 12:4, type B-2 using 40 mm graded stone aggregate. ii) All armoured cables shall enter through bottom of the feeder pillar box duly glanded and socketed and connected to MCCB/cable terminal. iii) All the outgoing cable shall be terminated in bakelite cable connector and shall be duly glanded and socketed. iv) All the cables power and control wiring should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required. (v) White acrylic marked plate for feeder switch marking to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive. (vi) Cost of all these factors shall be deemed included in the quoted unit rates.
M/s Prem Associates
K B ENTERPRISES
Jain Electricals
TARKESHWAR DASS CONSTRUCTION COMPANY
Aditya Enterprises
ANNAPURNA ENTERPRISES
L P Singh and Co.
SINGH ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .