Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹10.8 L+₹72,500 (7.23%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹11.9 L+₹1.9 L (19.1%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹14.0 L+₹4.0 L (39.5%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L4 | Rejected-Finance BEING L4 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Aug 2022, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR / MAINTENANCE OF INTERNAL ELECTRIFICATION AND CONNECTED WORKS AT MD / OTM ACCN AT MAKARPURA AT AF STN BARODA
2022_MES_542380_1
8719/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹30,000
Yes
14 Sept 2022
1 Aug 2022
31 Aug 2022
1 Aug 2022
29 Aug 2022
16 Aug 2022
2 Aug 2022 - 10 Aug 2022
Amount
Taking down carefully copper / Aluminium point wiring of light, fan, socket or power points complete including fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical, fan regulators, light or power sockets etc and removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
Material and labour for point wiring using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade with and including PVC conduit (medium grade) of suitable size concealed in wall etc with using new sunken type pressed steel box/terminal boxes not less than 1.6 mm thick covered with 3 mm thick laminated sheet for mounting fittings duly painted with two coats of black bituminous paint over a coat of red oxide primer with and including all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as earth wire connected to common earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive of cutting chases in brick walls/pillars etc for concealing & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with adjacent surfaces complete.
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switches.
One 3 pin 5 Amps socket outlet on independent board.
One bell point controlled by one way switches
One light point controlled by two, two way switches
All as per item No. 2 above but using 2.5 Sqmm PVC insulated, unsheathed copper conductor cable and earth conductor of 1.5sqmm copper cable for one 3 pin socket outlet 15 Amps on independent board.
M&L for point wiring using 1.5 Sq mm (nominal area) stranded copper conductor single core PVC insulated & unsheathed cable 1100 volts grade with and including PVC casing and capping of suitable size fixed on surface all as directed with using new sunken type pressed steel box/terminal boxes for mounting fittings (junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer) and covering with 3mm thick laminated sheet with and including all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor PVC insulated & unsheathed cable as earth wire connected to commen earth dolly complete all as specified and directed for the following :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board.
One light point controlled by two, two way switches
One bell point controlled by one way switches
All as per item No.4 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 1.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board.
Note:(for item 01 to 05): Being maintenance work Contractor shall carry out even single point wiring or associated work as per the direction of concerned JE(E/M)/AGE E/M. Delay in any work more than 3 days after allocation will invite recovery at double the quoted rate.
S&F piano switch flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified & directed.
S&F bell push, 6 Amps, flush type, 230/250 Volts, 50 Hz supply complete all as specified and directed.
S&F piano switch flush type 15 Amps single pole, one way 230 volts AC circuit complete all as specified and directed by Engineer-in-Charge.
S&F socket out let 2 in 1, 3 pin 5 Amps flush type, 230 volts Ac circuit complete all as specified and directed.
S&F socket out let 2 in 1 multipurpose three pin, 15 Amps & three pin 5 Amps 230 volts AC circuit complete all as specified & directed.
S&F ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed.
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Disconnecting and taking down old existing light fittings of any description and supply and fixing new indoor decorative channel housing fitting slim LED batten 10 Watt (Mirror Light) 2 Feet with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with suitable size copper conductor flexible cable from ceiling rose to connector of the light, fixing the same with two Nos PVC square box complete all as specified and directed.
Disconnecting and taking down old existing light fittings of any description and supply and fixing new indoor decorative channel housing fitting slim LED batten 20 Watt with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with suitable size copper conductor flexible cable from ceiling rose to connector of the light, fixing the same with two Nos PVC square box complete all as specified and directed.
Disconnecting and taking down old existing light fitting of any description and in any position and Supply and fixing new LED light fitting recess mounted/pendent mounting ultra slim LED flat panel 2x2 down light 36W with aluminium extruded housing with full opal diffuser IP 20 suitable for perfect lighting condition 240 volt, 50 Hz AC supply complete all as specifieda and directed.
S&F switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and directed
M & L for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 4 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 6 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 2.5 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of 2.5sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
M & L for sub main wiring using two single core 1.5Sqmm ZHFR PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 1 Sqmm earth wire, ZHFR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 1.5sqmm and one run of 1sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
M & L for sub main wiring using two single core 2.5Sqmm ZHFR PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 1.5 Sqmm earth wire, ZHFR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 2.5sqmm and one run of 1.5sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
Taking down old sunken box of any type and S and F new Galvanised (GI) metal Boxes Modular type 3 module concealed and making good the disturbed surface by white cement & Existing colour oil bound distemper complete all as directed by Engr-in-charge.
Taking down old sunken box of any type and S and F new Galvanised (GI) metal Boxes Modular type 4 module concealed and making good the disturbed surface by white cement & Existing colour oil bound distemper complete all as directed by Engr-in-charge.
Taking down old sunken box of any type and S and F new Galvanised (GI) metal Boxes Modular type 6 module concealed and making good the disturbed surface by white cement & Existing colour oil bound distemper complete all as directed by Engr-in-charge.
Taking out existing U/S hylem sheet cover plate including switches and replace the same with new plastic laminated sheet including providing housing for switch socket as per site requirement complete all as specified and directed
S & F switch piano Modular type single pole one way 6 Amp 240 Volts complete all as directed.
S & F switch piano Modular type single pole two way 6 Amp 240 Volts complete all as directed.
S & F switch piano Modular type single pole one way 16 Amp 240 Volts complete all as directed.
S & F socket only 6 Amps 2 in 1 with Shutter Modular type 240 Volt complete all as directed .
S & F socket only 6/16 Amps Twin Socket Modular type 240 Volt complete all as directed .
S & F Bell push switch Modular type single pole one way 10 Amp 240 Volts complete all as specified and directed.
S & F Fan Regulator 1Module FSC Modular type 240 Volts complete all as specified and directed.
S & F in repair Linear LED T8 tubular lamp of 20 watt with extruded aluminium body, PC diffuser and inbuilt driver suitable for LED T8 lamps, complete with all accessories internally pre-wired and including connecting to ceiling rose with three core flexible copper conductor cable of size 1 Sqmm complete all as specified and directed.
S & F in repair Linear LED T/L rode T8 tubular lamp of 20 watt extruded aluminium body, PC diffuser and inbuilt driver including taking out existing U/S T/L complete all as specified and directed
S & F in repair Decorative wall mounting antique brass finish fixture with opal glass diffuser suitable 7.5 watt A60 LED filament Lamp E27 base complete all as specified and directed
S & F LED security light luminaire 30 watt freedom, pressure die cast aluminium housing, heat resistant glass, IP66 protection, better optics for uniform distribution complete with all accessories internally pre wired and including connecting up with three core 1.5 Sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and directed
S & F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 liture, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed
S & F of PVC conduit size 25mm Rigid non-metaLlic PVC conduit exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mount tube ends and fixing accessories including chase cutting such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
S & F in repair Combined plates for Athena (white) Modular type 2 way complete complete all as specified and directed.
S & F in repair Combined plates for Athena (white) Modular type 3 way complete complete all as specified and directed.
S & F in repair Combined plates for Athena (white) Modular type 4 way complete complete all as specified and directed.
S & F in repair Combined plates for Athena(white) Modular type 6 way complete all as specified and directed.
S & F in repairCombined plates for Athena(white) Modular type 8 way(Vertical or Horizontal) complete all as specified and directed.
Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified. Note : (i) Copper thimble shall be used for connection of cable . (ii) MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule.
S & F in repairs MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. Note : Copper thimble shall be used for connection of cable.
Description all as per item No 45.00 above but 8 way.
Description all as per item No 45.00 above but 12 way.
Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity B series fixed in DB's complete all as specified and directed.
Supply and fix in repairs MCB, four pole 40 to 63 Amp 415 volts C series complete all as specified and directed.
Supply and fix in repairs MCB, single pole 240 volts 40 to 63 Amps capacity B series fixed in DB's complete all as specified and directed.
Supply and fix in repairs MCB, single pole and neutral link 240 volts 6 to 32 Amps capacity B series fixed in DB's complete all as specified and directed.
Supply and fix in repairs MCB, single pole and neutral link 240 volts 40 to 63 Amps capacity B series fixed in DB's complete all as specified and directed.
Dismantling Geyser of any capacity and of any description for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflow Geyser element, thermostat , ‘U’ assembly etc. with brush, cleaning rod, and using / circulating suitable concerned de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning and refixing and installation of Geyser in position and testing to the entire satisfaction of engineer-in-Charge.
S & F in replacement of defective existing ‘U’ assembly of 25 Ltr cap geyser of any description and in any position and fixing new ‘U” assembly to match with the existing system complete all as specified and directed.
S & F in replacement Thermostat suitable for existing make and type with setting range 30°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed.
S & F in replacement fusible plug/safety valve as per sample ISI marked having melting point 90°C to 95°C complete all as specified and directed.
S & F in replacement Geyser element of 2000 Watt, 230 volts complete all as specified and directed.
S & F in replacement indicating lamp of size /shape as per existing complete all as specified and directed.
Disconnecting and taking up/down existing unserviceable PVC connection and supply and fixing new PVC connection 15 mm dia 450 mm long having brass nut and washer on both end suitable for Hot/Cold water complete all as specified & directed.
Disconnecting and taking up/down existing unserviceable copper conductor flexible cable of any size and any description and supply, connecting, testing new 3 core copper conductor cable of 40/0.0076 size PVC insulated and PVC sheathed suitable for 1100 volts grade complete all as specified & directed.
Disconnecting and taking out existing defective / nonfunctional metal clad socket of any description and supply and connecting new metal clad socket 25 Amp 3 pole 230 volts complete all as specified and directed.
Disconnecting and taking out existing defective / nonfunctional metal clad top plug of any description and supply and connecting new metal clad top plug 25 Amp 3 pole 230 volts complete all as specified and directed.
S & F in repair gun metal non return valve 15 mm dia including making proper connection complete all as specified and directed by Engr-in-Charge.
S&F in repair LED bulb 15 att 5 star rating complete all as specified and directed.
S&F in repair door bell ding dong, multi tune, Chime and Buzzer complete all as specified and directed.
S&F Ceiling fan 1400 mm sweep, BEE 5 star rating energy efficient with complete accessories and connecting to the point wiring with necessary felxible copper conductor cable of multistranded three core of suitable length from fan to the ceiling rose complete all as specified and directed.
S & F sheet metal enclosure SP with two pin and socket with one single pole MCB 25 Amps, 'B' curve 240 Volts complete all as specified and directed
Badri Electricals
Shiv Kripa Tradimg
ARTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .