| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹30.1 L+₹20,545 (0.69%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L2 | Rejected-Finance being not L1 bidder | |
| 3 | L3₹31.5 L+₹1.6 L (5.39%)Rejected-Finance MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L3 | Rejected-Finance being not L1 bidder | |
| 4 | L4₹31.9 L+₹1.9 L (6.43%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L4 | Rejected-Finance being not L1 bidder | |
| 5 | L5₹32.9 L+₹2.9 L (9.78%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L5 | Rejected-Finance being not L1 bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
17 Jun 2023, 6:00 pmClosed
Garrison Engineer Utility-I
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF VCBS, RMUS, TRANSFORMERS, ELECT DISTR SYS INCL CALIBRATION OF RELAYS METERS AND OTHER ALLIED WKS AT 104 AREA, SVN COLONY, NIRMAN PARK NCB, 32 WEU/HF/DF AREA, CE OFC COMPLEX AREA AND MGEDDA UNDER AGE E/M NO-II OF GE(U-I) VISAKHAPATNAM
2023_MES_597154_1
8535/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
5 documents required · 5 mandatory
₹500
Garrison Engineer Utility-I
₹96,000
Yes
30 Jun 2023
20 May 2023
19 Jun 2023
20 May 2023
17 Jun 2023
5 Jun 2023
Amount
M&L for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe side and taking out the transformer indoor/ outdoor type of capacity 500 KVA to 630 KVA, 11 KV / 0.433 KV, step down any make for carrying out complete overhauling which shall comprise of the following:- a) M&L for lifting, transporting, handling, the transformer to workshop and opening top cover of the transformer by unscrewing nuts, bolts, washers etc. including disconnecting core assembly from HT/ LT bushing and lifting the same gently and taking out from the shell (container/ body) of the transformer. b) M&L for draining out transformer oil from the above said transformer in the suitable capacity of container /drums and keeping it in safe custody for reuse. c) M&L for cleaning the transformer body from inside, removing deposited dirt/ sludge/ foreign particles etc. from the bottom/ body of the transformer and drying up the shell from inside before refilling of the transformer oil. d) M&L for cleaning and washing thoroughly core and windings of the transformer by hosing down with clean dry oil conforming to IS 335/1983, removing deposited dirt/sludge/foreign particles from the windings/ core, thorough inspection of windings, providing insulations to leads and terminals, heating/ drying/ baking complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as directed by Engr-in- charge. (Contd...)
e) Lifting and re-fixing core assembly inside the transformer shell gently and carefully, connecting primary/ secondary/ Neutral connections to the bushings assembly, fixing of tap change over including tightening of nuts, bolts, washers of the core to reduce humming noise all as directed. f) Refilling the filtered transformer oil in the shell of transformer complete. g) Re-fixing the top cover including replacement of cork sheet/ gasket 8mm thick, tightening of nuts/ bolts/ washers etc. and replacement of breather with silica gel crystal type all as directed by Engr-in charge h) Lifting/ shifting to the place from where removed or to any location as directed and re-installing the transformer including connecting primary/ secondary/ neutral connections etc. all as directed by Engr-in-Charge. j) The inspection of transformer shall involve:- i) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts. Ii) Checking all brazing, joints, tap heads and connection joints. iii) Checking all jumpers, terminations/ connections inside the transformer. iv) Checking the Buchholtz relay/ conservator MOG if any. v) Painting complete with two coats of synthetic enamel paint externally transformer shell complete all as directed by Engr-in-Charge. (vi) Inspection of tap changer, checking the moving and fixed contacts for contact wear and connection to winding. k) Conducting the tests on core and windings as per IS like ratio, magnetic imbalance, short circuit etc. in presence of Engr-in-Charge and test results shall be signed both by the contractor and Engineer -in-Charge and kept on record. Note:- (i) Any damage to insulators/ bushes/ windings etc. while in the custody of the contractor shall be made good at no extra cost to Department. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) M&L for rewinding/ re-insulation of HT/ LT (primary/ secondary) coils, bushes, studs, Transformer oil, cable box, replacement of buchholtz relay/ MOG if any etc will be measured and paid separately. (Contd...)
All as per Item No. 1 herein before but transformer / Voltage stabiliser indoor / outdoor type of capacity up to 400 kVA
Filtration of transformer oil of transformers / FRMUs installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the Engineer-in-Charge.
Supply and topping up of transformer oil with di-electric strength not less than 60 KV into the conservator tank / body tank of the transformer / OCB / FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. Make: Apar (Power Oil) / Savita (Transol) / Asian
M&L for rewinding of distribution (HT/LT) transformers of capacity 50 to 400 KVA type by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials / bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.
All as per Sl item No. 5.00 but transformers of capacity 500 to 630 KVA
M&L for re-insulating windings of HT / LT distribution transformers of capacity 500 to 630 KVA by strip opening of HT / LT coils (i.e. Primary / secondary coils) from core assembly safely, unwinding the HT / LT coils (i.e. Primary / secondary coils) complete, removing the old defective insulation paper and replacing with new DPC insulation to the copper conductor, re-varnishing of the windings with super varnish including heating, drying, backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as directed by Engr-in- charge.
Disconnection of the distribution transformer of capacity 500 to 630 KVA from HT and LT supply mains, removing of Bus duct and Bus bar, leakage arresting by draining out of oil after arrangement of necessary empty oil drums, buckets etc.,dismantling of top cover and acessories, dismantling of LT bushings by disconnecting leads / jumpers from inside, replacement of gaskets and oil seals and re fixing of the LT bushings, making internal and external connections, replacement of cover gasket and acessories, reassembling of acessories and cover, filling back of existing transformer oil complete and making cable connections and assessing for energising the transformer complete all as specified and as directed. Note: (i) The rate quoted shall include cost of materials like gaskets and oil seals and labour etc. (ii) Bushing and bushing rods shall be measured and paid separately.
All as per Sl item No. 8.00 but Transformer of capacity 250 to 400 KVA
All as per Sl item No. 8.00 but Transformer of capacity upto 200 KVA
Disconnecting the HT/LT connections of transformer of capacity 500 to 630 KVA i.e (Bus duct / Cable bunch) keeping all the cables out from the HT/LT sides, physically checking the transformer for healthiness, performing the transformer tests like HV/LV Meggar test, Ratio Test, Magnetic Balance test and short circuit tests for checking condition of transformer complete all as specified and as directed. Note:- (i) All testing shall be done in presence of Engr-in-Charge or his accredited rep and test reports shall be signed by contractor and Engr-in-Charge and kept on record. (ii) If the transsformer found satisfactory then HT/LT connections shall be done by the contractor and has to charge the transformer. (iii) If the transformer fails in these tests then the contractor has to shift the transsformer for winding /overhauling which will be measured and paid separately. (iv) Cost of winding / overhauling if required shall be measured and paid separately.
All as per Sl item No. 11.00 but transformer of capacity 250 to 400 KVA
All as per Sl item No. 11.00 but transformer of capacity upto 200 KVA
Shifting the Transformer of capacity 500 to 630 KVA from existing site to another site within 3 Km distance range by Dismantling of HT and LT cable connections, jumpers and busbars including LT busbar cable boxes and closing the transformers for loading into transporting vehicle with the help of crane, transportation to another site, unloading, cable connections both HT and LT, testing and commissioning complete all as specified and as directed.
All as per Sl item No. 14.00 but transformer of capacity 250 to 400 KVA
All as per Sl item No. 14.00 but transformer of capacity upto 200 KVA
M&L for replacement of silica gel breather assembly complete suitable for 500 to 630 KVA transformer as per existing with breather unit and silica gel including connecting with proper necessary gaskets if necessary & removing the unserviceable breather assembly complete all as specified and as directed.
All as per Sl item No. 17.00 but transformer of capacity 250 to 400 KVA
All as per Sl item No. 17.00 but transformer of capacity upto 200 KVA
Supply and replacement of silica gel in breather of transformers all as specified and as directed.
S&F in repair conservator tank assembly suitable for transformer of capacity 500 to 630 KVA as per existing and including connecting properly with gaskets if necessary & removing the unserviceable conservator tank complete all as specified and as directed.
All as per Sl item No. 21.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 21.00 but suitable for up to 200 KVA transformer
S&F in repair gun metal drain valves suitable for transformer of capacity 500 to 630 KVA including dismantling old one complete all as specified and as directed. Make :- Upadhyay / Leader / Zoloto
All as per Sl item No. 24.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 24.00 but suitable for up to 200 KVA transformer
S&F in repairs off load tap changer assembly suitable for transformer of capacity 500 to 630 KVA as per existing with 7 tapping position including opening top cover, conservator etc complete all as specified and as directed.
All as per Sl item No. 27.00 but suitable for up to 400 KVA transformer
S&F in repair WTI (Winding Temperature Indicator) suitable for distribution transformer of capacity 500 to 630 KVA as per existing complete all as specified and as directed.
All as per Sl item No. 29.00 but suitable for up to 400 KVA transformer
Supply only LT bushings made out of porcelain, as per existing and suitable for distribution transformer of capacity 500 to 630 KVA including dismantling old one and complete all as specified and as directed. Make:- Pactil / BHEL / Jaipuria Brothers
All as per Sl item No. 31.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 31.00 but suitable for up to 200 KVA transformer
Supply only HT bushings made out of porcelain, as per existing and suitable for distribution transformer of capacity 500 to 630 KVA including dismantling old and complete all as specified and as directed. Make:- Pactil / BHEL / Jaipuria Brothers
All as per Sl item No. 34.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 34.00 but suitable for up to 200 KVA transformer
Supply only LT bushings rod made out of copper with threading, as per existing and suitable for distribution transformer of capacity 500 to 630 KVA including dismantling old one and complete all as specified and as directed.
All as per Sl item No. 37.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 37.00 but suitable for up to 200 KVA transformer
Supply only HT bushings rod made out of copper with threading, as per existing and suitable for distribution transformer of capacity 500 to 630 KVA including dismatling old one and complete all as specified and as directed.
All as per Sl item No. 40.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 40.00 but suitable for up to 200 KVA transformer
S&F in repair OTI (Oil Temperature indicator) as per existing suitable for distribution transformers of capacity 500 to 630 KVA including dismantling old one and complete all as specified and as directed.
All as per Sl item No. 43.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 43.00 but suitable for up to 200 KVA transformer
M&L for providing new cable box made out of MS sheet of thickness not less than 3.15 mm including fabrication works, welding etc. to suit the LT/HT side of existing transformer size, including nuts, bolts, cable glands, termination of existing cables etc. as per existing and suitable for distribution transformer of capacity 500 to 630 KVA complete all as specified and as directed
All as per Sl item No. 46.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 46.00 but suitable for up to 200 KVA transformer
M&L for replacement of Drain plugs to valves/conservator caps of the sizes 3/4", 1", 1.5" valves and plugs, as per existing suitable for distribution transformers of capacity 500 to 630 KVA including dismantling old one and complete all as specified and as directed.
All as per Sl item No. 49.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 49.00 but suitable for up to 200 KVA transformer
S&F in repair Oil gauge glass with gaskets as per existing suitable for distribution transformers of capacity 500 to 630 KVA including dismantling old one and complete all as specified and as directed.
All as per Sl item No. 52.00 but suitable for 250 to 400 KVA transformer
All as per Sl item No. 52.00 but suitable for up to 200 KVA transformer
M&L for preparation of old exposed painted surfaces of indoor / outdoor type transformer of capacity 500 to 630 KVA and painting the same with two coats of synthetic enamel paint including writing details of transformer on transformer plinth / base with white synthetic enamel paint on black synthetic enamel paint back ground complete & including one coat of white wash on exposed surface of transfomer plinth / base complete all as specified and as directed. Note :- Colour of paint shall be as decided by Engr-in-Charge. Make:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
All as per Sl item No. 55.00 but for transformer of capacity 250 KVA to 400 KVA
All as per Sl item No. 55.00 but for transformer of capacity up to 200 KVA
Clearing away all bushes, small plants, grass, vegetation, saplings, shrubs, brushwood, undergrowth, roots upto root level including surface dressing n.exc 15 cm deep around and surroundings areas of E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards, pump house & Misc E/M installations etc) and removing rubbish / debris upto a distance of not less than 50 metres outside the periphery of the area under clearance complete all as directed.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, of size 300mmx 180mm x 40mm, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
S&F 100 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection including taking down old one complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
M&L cable jointing kit for 11 KV (Earthed grade) 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm for outdoor termination, heat shrink type joint complete with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
M&L cable jointing kit for 11 KV (Earthed grade) 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm for straight through, heat shrink type joint with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
M&L cable jointing kit for 11 KV (Earthed grade) 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 150 sqmm for indoor termination, heat shrink type joint complete with jointing material and accessories complete all as specified and directed. Make:- 3M / Denson / Raychem
Supply & laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, Earthed, grade cross sectional area 185 Sqmm, 3 core, laid in trenches / duct / on pole including taking down complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Asian Cables / Finolex
All as per Sl. Item No. 68.00 above but for cable of size 240 sqmm x 3 Core
M&L for detecting HT 11KV UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes complete all as directed. Note:- The rate quoted deemed to be inclusive of arrangement of necessary fault locator equipment, transportation of equipment& charges for service engineer.
M&L for repair and servicing of HT 11 KV four pole structure by replacing Aluminium PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation sleeve RYB of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc and pin insulators and applying silicon compound for prevention of arcing due to dust / salt deposits over surfaces including preparation of surfaces, applying zinc chromate primer on rusted surfaces and applying one coat of aluminum paint to the entire structure complete all as specified and as directed. Note : Rate quoted shall be inclusive of two coats of white wash on exposed concrete surfaces of structure. Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
All as per Sl item No. 71.00 but for two pole structure
S&F danger notice plate of size 25 x 20 cm & 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT including dismantling compete all as specified and as directed.
M&L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections and including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including preparation of surfaces and applying two coats of aluminium paint over a coat of primer and dismantling complete all as specified and directed. Make of paint : Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd
S&F in repair disc insulator porcelain vitreous brown 145 mm height & 255 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 11 KV complete all as specified and as directed.
S&F in repair for pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut for 11000 volts grade 150 mm dia & 150 mm height complete all as specified and as directed.
All as per Sl item No. 76.00 but for post type insulator
M&L switches air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 volts all as per clause no 19.69 of SSR part-I (2009) including taking down complete all as specified and directed. Make:- Pactil / BHEL / Jaipuria Brothers
All as per Sl item No. 78.00 but for current rating upto 400 amps
S&Fdrop out lift OFF HT 11 KV, 200 Amp fuse link consisting of channel iron base having 2 Nos 11 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze conforming to IS 9385 complete all as specified and directed. Make:- Pactil / BHEL / Jaipuria Brothers
S&F in repairs male contact suitable for GOD 11 KV grade, 200 Amp rating & of make as per OEM complete all as specified and as directed.
S&F in repairs Female Contact suitable for GOD 11 KV grade, 200 Amp rating & of make as per OEM complete all as specified and as directed.
S&F in repairs Tinned copper flexible jumper suitable for GOD 11 KV grade, 200 Amp rating & of make as per OEM complete all as specified and as directed.
S&F in repairs MS Jumper carrier suitable for GOD 11 KV grade, 200 Amp rating & of make as per OEM complete all as specified and as directed.
S&F in repairs Back connector plate suitable for GOD 11 KV grade, 200 Amp rating & of make as per OEM complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Servicing, Inspecting, checking, cleaning by using of blower, lubrication, greasing and carrying out preventive maintanance of RMU of capacity 11 KV, 250 / 350 MVA including calibrating the relay by conducting secondary injection tests and RMU in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. Notes: Unit rate quoted shall be deemed to include cost for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of RMU panels with approved colour including lettering details all as per exisitng.
Supply & fixing in repair Self powered relay with O/C, S/C, E/F protection, having front USB port for laptop interface, LCD display,10 event records, 5 fault records, min 2 setting group and keypad for setting parameters for the relay complete suitable for RMU of capacity 250/350 MVA all as specified and as directed. Make:- Schneider / Siemens / L&T / ABB
S&F in repair phase indicator lamps (Red, Yellow and blue) suitable for RMU of capacity 250/350 MVA complete all as specified and directed. Make:- L&T / Siemens / GE / RR Micro / BCH / Schneider
S&F in repair 11KV, 230V, AC, 1KVA control transformer suitable for RMU of capacity 250/350 MVA complete all as specified and directed. Make :- AE / English Electric / Crompton Greaves / Areva T&D / Schneider
S&F in repair Battery with & including battery charger, 12Ah, (I/P-230V AC, O/P - 24V DC suitable for RMU of capacity 250/350 MVA complete all as specified and directed. Make:- Exide / Amron / Amara raja / Luminous
S&F in repair Spring charging motor suitable for RMU of capacity 250/350 MVA complete all as specified and directed.
Taking down HT switch gear (Vacuum circuit breaker ) at sub station of capacity 11 KV 250/350 MVA comprising of following repairs, overhauling, servicing, carrying out preventive maintenance and refixing the same after repairs/ overhauling: (a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection/overhauling (b) Servicing/Inspecting/checking of automatic safety shutter, circuit spout and circuit spout connections for RYB phases and replacement of spares operation for serviceability and replacement of spares if required. (c) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (d) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (e) Servicing/Inspecting/checking of secondary sockets/busbar earthing plugs/earthing sockets and replacement of spares if required. (f) Checking, setting and adjustment of lowering and raising operation of the breaker trolley. (g) Decarbonising of busbar and connected items (h) Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly. (Contd...)
j) The inspection of HT switch gear shall involve:- (i) Inspection of truck & hoist assembly. (ii) Inspection of tank assembly & barriers. (iii) Inspection of assembly & components of solenoid assembly. (iv) Inspection of assembly & components of dependent mechanism. (v) Inspection of assembly & components of spring box mechanism. (vi) Inspection of motor mechanism spring charge assembly (vii) Inspection of assembly of trip unit & related components Note: (i) The servicing includes for busbar duct chamber, cable alleys and connecting accessories (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (iii) Major spares like Breaker bushings, vacuum interrupter assly, busbar spout, busbar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assly/barriers, solenoid spares, dependent/spring mechanism/ motor mechanism, trip unit etc will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement. (iv) the servicing shall be carried out by Auhtorised service centre as approved by GE
Supply only the following spares suitable for 11 KV VCB 630 to 800 Amps and 11 KV HT panel repair work & of make as per OEM if not specifically mentioned:-
CTs epoxy cast wound primary CTs with minimum primary current 60 to 400 A, single/ double ratio, double core (Protection core-5P10 & Metering core- Class 1.0), 25 KA for 1 sec of 15 VA minimum Burden.
Supply only 1.5 sqmm flexible PVC stranded copper conductor cable, unsheathed, 1100 V grade for control wiring. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL
Supply only 2.5 sqmm flexible PVC stranded copper conductor cable, unsheathed, 1100 V grade for control wiring. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL
LED Indication Lamps
Shunt trip coil 110 V DC/220 V DC
Shunt trip coil 110 V DC/220 V DC with assembly (Make- Schneider, Part No- ECO39SN134100FN)
Breaker control switch
Busbar Spout
Circuit spout
Control circuit fuses 2 A to 63 A
HRC fuse (PT HT side)
PT plug contact
Multifunction meter, Digital type (Displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc.) Class 1/0.5 with RS485 port for communication in Modbus protocol. Make:- Havells India Ltd. / HPL India Ltd. / L&T / AE / Schneider / BCH
VCB Tripping buffers
VCB Closing buffers
110 Volt DC closing coil assembly (Make- Schneider, Part No- ECO39SN134900FN)
Push to trip knob red assembly
1250A finger type Isolating tulip contacts
Ratchet wheel
Nylon release lever
VCB charging powl
Shutters for racking shaft
Bus bar support insulator for VCB panel
Vaccume Interrupter Bottle (Make-Schneider, Part No-VSLVG4002-01)
Rectifier (Make-Schneider, Part No- ERC-A-A00DC-001)
Master Trip Relay complete all as specified and as directed. Make: ABB / Siemens / Schneider
Auxiliary Relays for Transformer Protection complete all as specified. Make: ABB / Siemens / Schneider
Space heater in HT VCB 11 kv 110 Volts DC supply
Thermostat for space heater
Spring Charging motor 230 Volt AC (Make-Schneider, Part No-MVIJOO157-02)
T‐N‐C Switch (Breaker Control Switch)
Isolating Contact (Make-Schneider, Part No- MVIK00190-01)
Drive Beam suitable. (Make - Schneider, Model No MCS27S0298700PN)
Epoxy Body. (Make - Schneider, Model No MEP3953022000FN)
Drive Rod assembly with contact block VG2
M&L for setting of 3 phase IED of any type/Make from 11KV HT panel, cleaning the contacts , IED configuration , Calibration & Testing of all the measuring & protection devices viz., CTs, Relays and Meters at site. Testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set , checking of current transformer , rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & Tripping coil. Adjustment / setting to plug and time multiplier settings of IED to achieve the discrimination in tripping, tune/synchronies upstream breaker relay settings-installation of relay, testing & commissioning etc. complete all as specified and as directed.
M&L for collecting necessary required data & peak load details from IED / DMT of any type / Make from 11KV HT panel, transformer full load details during peak hours, relay Setting calculations & Co-ordination study, unit protection setting of transformers, furnishing feeder wise settings & submitting report with firm recommendations, achieving stream power distribution (complete 11 KV system) overall co-ordinations of time, adjusting / setting to plug and time multiplier settings of IED/DMT complete all as specified and as directed by Engr-in-Charge.
M&L for applying silicone High Voltage Insulator coating (Si-COAT 570 RTV) solution using electric airless sprayer to the inside surface of cable chamber alongwith busbar chamber of 11 KV Indoor VCB panel including all disconnection & re-connection of cables etc. complete all as specified and directed. Note:- Quantity of solution consumed per VCB panel shall not be less than 6.8Kg
Supply and fixing Resin Cast CT dual core, CT single pole, ratio- 100/50/5A-5A For 800A , 11 KV VCB panel.
M&L for maintenance/servicing of PT unit 11KV / 110V by disconnecting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of bus bar connections, resin cast PTs using hot blower, CTC solution, applying backlot (Red) solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and directed.
Supply, installing, testing & Commissioning of Numerical feeder protection relay 50/51N (Earth over current), 67P (3Ph directional over current), 67N (Earth fault directional over current), 51V (Voltage controlled over current), 37 (3Ph under current), 46 (Negative Phase sequence over current), 59N (Residual over voltage), 32 (Directional power protection under/over active/Reactive power), 81 (Under over over Frequency ), 49 (Thermal Overload),79 (Auto resue), 50BF (Circuit breaker failure direction), Cold pickup, Inrush blocking including taking down old relay complete all as specified and directed by Engr-in Charge. Note :- Relay will be on Modbus Protocol. Make:- Schneider / Siemens / L&T / ABB / Areva
S&F 2V, DC, VRLA cell and connect them properly with connecting leads inside battery rack suitable for control DC circuit of 11 KV VCBs and after assembling required voltage is 110V / 100AH including taking down old complete all as specified and directed by Engineer-in-Charge. Make:- Exide / Amron / Amara raja / Luminous
M&L for repair of 110v DC/100Ah/30A battery charger by replacing 3 sets RYB LED lamp, 2 amps HRC fuses, block contact relays, 6 nos, 3 sets a PLC card, wiring and required nuts and bolts, 32 amps TPN MCB, 6-20 amps SP MCB, 4 units, boost cum floating charging unit cum relays , rubber gaskets, key / padlocking handle, and painting the cabinet with powder coated paint completely all as specified and directed by Engr-in-Charge.
S&F in repair lightning arresters expulsion type complete with all fittings, station class, discharge capacity 10 kilo amp suitable for 11000 volts including taking down complete all as specified and directed. Make:- Oblum / Elpro / BHEL / Areva T&D / Jaipuria Brothers
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 of SSR part-I connected to earthing test point including dismantling existing old earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L Earthing Electrode 3000 mm length copper coated, 100 microns thickness as per UL standard approved and testing by CPRI, pipe in pipe type inner pipe dia 41.9mm (min), outer dia 76/80mm (min) annular space filled with high conductivity and anti corrosive compound with connection terminal. M&L infill compound Chemical) 50Kgs (2 Bag each 25 Kgs) Elecrodite / Humedites constituting natural element not water dissoluble reduce soil resistivity highly hygroscopic and swells high conductivity and anti corrosive retains moisture for a long time. M&L Earth work Vertical excavation in normal soil upto a depth of 3000mm the diameter of the bore hole being minimum 250 mm. installation filling the bottom 4" of the bore with infill compound (Chemical) vertically placing the electrode in the centre of the pit, fill the cavity around the electrode with the chemical ensuring there are no air gaps in the chemical filled cavity region make a thick paste by pouring water into the earth pit and mixing the mixture with a pole including PCC earth Pit and RCC Pit cover complete all as specified and as directed.
S&F in repair earth continuity conductor or main earthing lead using 32 x 6 mm galvanised iron strip, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
M/S CHANDRA ENGINEERS AND CONTRACTORS
jyothi constructions
SRIESWARI ENTERPRISES
SAMPATH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .