Executive Engineer
Elect. Division HPPWD Palampur
C/O Rajeev Gandhi Govt. Engineering College Kangra at Nagrota Bagwan in Distt. Kangra (H.P) (SH- Providing E.I to Electrical Engineering Block (Balance work)
2023_PWD_67621_1
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
30 days
Kangra at Nagrota Bagwan
Please refer Tender documents.
9 documents required · 9 mandatory
₹350
₹16,100
11 Mar 2023
28 Jan 2023
7 Feb 2023
28 Jan 2023
7 Feb 2023
28 Jan 2023
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Make:- SCI/KEI/Plaza.
Group C.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.Make:- SCI/KEI/Plaza.
2x2.5 Sq. mm.
2x4.0 Sq. mm.
2x16 Sq. mm.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:- SCI/KEI/Plaza.
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.Make:- SCI/KEI/Plaza.
3x2.5 Sq. mm.
Supplying and fixing 32 Amps, 415 volts, TPN industrial socket outlet, 4-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 25 Amp TPN-MCB, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required. Make:- SCI/KEI/Plaza.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 630 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-Make:- SCI/KEI/Plaza.
Armoured cable 25 sq. mm (3.5 core)
Supplying and fixing following rating,Four Pole, 440 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make:-L&T/Schnieder/Anchar
MCB 40Amp Four Pole
Supplying and installing follwing size of perforated hot dipped galvanized iron cable tray (Galvanized thickness not less than 50 microns) with perforation not more that 17.5 % in convenient sections joined with connectors ,and hanged on the wall with MS bolts and nuts as required (Make:-L&T/Schnieder/Anchar
Supplying and installing follwing size of perforated hot dipped galvanized iron cable tray bends (Galvanized thickness not less than 50 microns) with perforation not more that 17.5 % in convenient sections joined with connectors ,and hanged on the wall with MS bolts and nuts as required
Providing and fixing surface mounting LED luminaire of following rating with powder coated CRCA housing with high power LEDs, diffusser to avoid glaire, it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.Make:-Philips/Panasonic/wipro
LED 40 watt surface mounted square LED Luminaire (2'x2')
Supplying & fixing following type of Surface mounted luminaires, white power coated CRCA housing diffusser to avoid glaire,it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion < 10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as requiredMake:-Philips/Panasonic/wipro .
LED Tube Fixture 20 watt, 4 feet long.
Supplying, Installation, Testing and Commissioning of outdoor s/door, Busbar Panel(Busbar 600A) of size (750+500)Hx750Lx300D board of suitable size cubical, weather, dust and vermin proof fabricated out of CRCA sheet steel suitable size thickness should be manufactured and supplied by CPRI approved and ISO 9001 certified OEM. The busbar system should be duly type tested at NABL lab for short time with stand current of 1 second, it should be suitable for wall or floor mounting with double door option, panel board enclosure should be robust construction and corrosion resistance, powder coated with seven tank process with locking arrangement, fixed on suitable size foundation 60 cm above the ground level by providing angle iron of 50x50x6 mm welded on all four corners embedded in PCC 1:2:4 using 20mm graded stone aggregate up to 30 cm including electrical connections with lugs and glands complete with installation, testing and commissioning etc. including the cost of copper alloy bus bar, digital type Ammeter,Voltmeter, modules and three phase indicating lamps as required complete in all respects. The panel should be approved/tested from the CPRI lab and should be confirmed to IS:64139. (Make: GM power control and switchgear/ EVA .
Supplying and Fixing of following way,Cable end box complete with all accesseries, connections, testing and commissioning etc. as required complete in all respects.Make:- L&T/ Hagger/Anchor
SPN 6 Way DD
SPN 8 Way DD
SPN 12 Way DD
SPN 16 Way DD
Per Phase isolation D.D
Per Phase isolation D.D
ASHOK KUMAR GOVT CONTRACTOR
pankaj saini
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .