| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹40.6 L+₹63,187 (1.58%)Rejected-Finance | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹41.6 L+₹1.6 L (4.04%)Rejected-Finance | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹41.7 L+₹1.7 L (4.36%)Rejected-Finance 6313 14 PUNJABI MOHALLA AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹45.0 L+₹5.0 L (12.5%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
12 Aug 2021, 6:00 pmClosed
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
SPECIAL REPAIR TO BUILDING NO. HT-14 OTM ACCN, PROVISION OF FOOTPATH FOR OR MD ACCN NEAR BUILDING NO. 226/154, 155, 162 AND 166 AT HARDING LINE AND PROVISION OF ONE TOILET BLOCK FOR OTHER RANK IN THE AOR OF AGE B/R-I (N)
2021_MES_459232_1
GE(N)Amb-23/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹74,000
Yes
25 Sept 2021
16 Jul 2021
14 Aug 2021
16 Jul 2021
12 Aug 2021
29 Jul 2021
16 Jul 2021 - 29 Jul 2021
Amount
Schedule 'A' Part-I (B/R itmes) Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removal of excavated material to a distance not exc. 50 m and depositing at a level nexc 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregates in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in chajjas complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits and sides of roof beams,lintels over 1.5 metre span for rough finished surfaces of concrete flats complete all as specified and as directed by the Engineer-in-Charge
Formwork to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 CM thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits of chajjas including sides for rough finished surfaces of concrete flat complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 6 to 8 mm dia cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel TMT bars 6 to 8mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks in half brick thick wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks using old servicable bricks including cleaning of old bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on fair faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rendring 15mm thick in cement plaster 1:6 on any faces of brick work or concrete wall surfaces and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in charge.
M&L rough cast plaster complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
S&F steel ventilators fixed type with glazing bars complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of celing and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered surfaces of wall and applying two coats of oil emulsion distemper with painting roller over and including 1 to 2mm thick wall care putty white cement based in two or more coats two achive smooth surface complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc. 63mm, deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregates as in sub base of floor and finished even and fair to receive tiles etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/skirtings/dados of size 350x250x7mm/450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm prelam PVC sheet on single side used instead of plain colour PVC sheet reinforced with MS square tube, edges will be painted to match with prelam sheet and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed by the Engineer-in-Charge.
S&F Galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.0mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing butt hinges 100 mm long medium weight cold rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
S&F 15mm bore cast copper alloy chromium plated stop valves fancy type with long shank and cup (concealed type) screwed down, high pressure with butter fly handle scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F angular type 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type bib tap 15mm bore cast copper alloy chromium plated long body with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 100mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed by Engineer-in-Charge.
S & F vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, PVC waste pipe , providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
S & F 32 mm bore Low density polyethylene pipes (LDPE)of pressure rating 6kgf/Sq cm of standard length suitable for WHB and sink complete all as specified and as directed by the Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm wide with chromiun plated brackets guard and railing 60 cm long complete all as specified and as directed by the Engineer-in-Charge.
S & F urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60gms) complete all as specified and as directed by the Engineer-in-Charge.
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S&F 125 mm dia brass chromium plated shower rose swivel type with arms of standard length complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors or fixed to walls complete all as specified and as directed by the Engineer-in-Charge .
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors or fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC(SWR) bends of any radius, diminishing pieces or tapers (larger bore measured ) complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC(SWR) bends of any radius, diminishing pieces or tapers (larger bore measured )complete all as specified and as directed by the Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed by the Engineer-in-Charge.
M & L stack clamp out of 50mm x5mm flat iron stays including bolt and nuts and securing ends of stays to walls or roof for 75mm bore pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) tripple layer body, 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I, complete all as specified and as directed by the Engineer-in-Charge. Note : Water storage tank shall be White in colour.
S&F 20mm bore Ball brass valves high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing roof surfaces and applying water proofing treatment over roofs comprising of the following,Complete all as specified & as directed:- (i) Applying oil bound bitumineous primer at the rate of 0.40 Liters/Sqm as per IS 3384-1986 on prepared surfaces.Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (ii) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 Kg/Sqm, black finished reinforced with non woven polyster matt, with a thermo fusible finish,torching overlaps with a propane or butane gas torch, with a overlap of 75mm at sides and 100mm at the ends,and sealing including applying a coat of cold emulsion bitumineous primer all as per manufacturer's instruction including prepration of surface. (iii) Applying one coat of hot straight run bitumen grade 30/40 (Grade S-35) confirming to IS -73 at the rate of 1.2 Kg/Sqm. Note:- The water proofing treatment shall be carried out by manufacturer or his authorized applicators in terms of clause 11.43 of MES Sch Part-'I' (2009)
M & L precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete with joints to match, except blocks or slabs complete all as specified and as directed by the Engineer-in-Charge.
M&L Machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 30 mm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed by the Engineer-in-Charge.
M & L providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
Surface dressing not exceeding 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness grade M-40 with grey cement and pigments over and including a layer of sand cushioning, 30 mm thick complete all as specified and as directed by the Engineer-in-Charge
M&L rendering 15mm thick in cement plaster 1:4 on any faces of brick work or concrete wall surfaces and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in charge.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 gm per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150gm/Sqm (Az-150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
Dismantiling timber framed work scantling 40 Sqm cm and over in section in any position complete all as specified & directed by the Engr-in-Charge.
S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I S.1161-1979 grade St.-240 complete all as specified and as directed by the Engineer-in-Charge.
Taking down roof trusses, coupled rafters or trussed beams, clear span above 4 metres & upto 8 metres complete all as specified and as directed by the Engineer-in-Charge
M & L rolled mild steel work in framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and as directed by the Engineer-in-Charge
Dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/ slabs/blankets any thickness including cover fillets and false ceiling frame /gird of any type/any description, fixed in position,complete all as specified and as directed by the Engineer-in-Charge.
S & F GI Metal powder coated suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications including 4mm thick HPSC pre-prime non asbestros fiber cement building board (E-classic or equivalent) decorateive finish fixed to frame work with hold down clips in false ceiling complete all as specified and as directed
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by Engineer in Charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill fabricated from 10mm square MS bar as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4 sqm each and removing the same from site complete all as specified and as directed by the Engineer-in-charge.
M&L rolled mild steel framed work as in chowkats of door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-W (Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
M&L prepration of new wooden surface and apply two coats of synthetic enamel paint over a coat of pink primer on surface of any description , not otherwise described over 10cm width or girth complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair brass chromium plated curtain rod 25mm dia fixed with and including decorative brackets ,stop roller and glass at the end etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing stainless steel butt hinges 100 mm long medium weight and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
Supply only mild steel butt hinges 50 mm long medium weight cold rolled and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge.
M&L vitrified ceramic tiles joint free 10 mm thick, 1st quality (square/ rectangular) area of each tiles not exc 0.36 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 15mm cement screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, and applying neat cement slurry @3 Kg/Sqm complete all as specified and as directed by the Engineer-in-Charge.
M &L 10mm thick coloured paver tiles (Endura Tiles) of size 300 x 300mm in floors etc set and jointed in neat cment slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in C.M 1 :4 ,complete all as specified and as directed by the Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge
M & L PCC 1:2:4 Type B2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' Part-II (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet but excluding bulk head fittings, tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 111 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 111 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and incuding provision of 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,with one PVC block of size 75mm x75mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED Bulb, retrofit 9 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
S&F step type electronic Fan regulator modular 120 watt, 2 module complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6 to 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing of SPN distribution board 8 way, double door, IP 43, as per IS 8623 including 200amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimble, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix RCBO 40 Amps, 2 Pole, 2 module, 30 mA (HI immunity) sensitivity, 230 volts, 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB single pole and netural, 240 volt, 32 to 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair over and Low voltage release 1 module, 230 volts AC, suitable for single phase adjustabe from 170 volts to 230 volts complete all as specified and as directed by Engineer-in-Charge.
S & laying sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supplying and fixing as in repair 1100 volts grade heavy duty cable 16 Sqmm multi- stranded aluminium conductor, PVC insulated served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-Charge.
Supplying and fixing 1100 volts grade heavy duty cable 10 Sqmm multi- stranded aluminium conductor, PVC insulated served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia suspension wire, one twin core cable flat or circular complete all as specified and as directed by Engineer-in-Charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing indoor decorative LED tube light fitting box type 1x18/20 watt with opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 1x18/20 watt LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, T8 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge.
S&F mirror light 9/12W LED wall mounting fixture, aluminium housing compact & energy efficient epoxy powder coated CRCA light luminaire, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection including taking down existing unserviceable security light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, auminum housing, surge protection including driver & LED lamp etc complete with all accessories connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Material & labour earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron wire earth lead of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
Material & labour as in repair earthing complete with copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to copper strip 20 x 3 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised iron, earth strip protected by GI pipe 32mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
S&F LED lamp Invertor technology 20-22 watt with 4 hour power back up with efficiency more than 100 lumen per watt,Lithium ion battery including removing of unservicable lamp complete all as specified and as directed by the Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades and applying two coats of painting on ceiling fans with synthetic enamel paint by spraying incl filling cavaties with filler after cleaning all dust etc.and reassembling the same and hanging the ceiling fan in same position, making all electrical connection using 3 core copper flixible cable and testing complete all as specified and as directed by the Engineer-in-Charge.
Taking down unserviceable DB along with MCB of any description and making good the distrubed surfaces of wall and paint touch up to match with existing finishes as per site requirement complete all as specified and as directed by the Engineer-in-Charge.
bhagwandasswazirchand
MAYANK ENTERPRISES
Sham Sunder Bansal
S M BUILDERS
M/s Vridhi Construction Co.
M/s Kuljit singh bedi
Karishan Kumar goel
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .