Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹9.1 LAccepted-AOC 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L 1 | Accepted-AOC As per NIT Criteria | |
| 2 | L 2₹10.2 L+₹1.1 L (12.1%)Rejected-Finance | L 2 | Rejected-Finance As per NIT Criteria | |
| 3 | L 3₹10.3 L+₹1.3 L (13.8%)Rejected-Finance | L 3 | Rejected-Finance As per NIT Criteria | |
| 4 | L 4₹11.0 L+₹1.9 L (21.2%)Rejected-Finance | L 4 | Rejected-Finance As per NIT Criteria | |
| 5 | Not Admitted-Fee 3 6 753 A GENERAL ELECTRICALS REFRIGERATION 3 6 753 A HIMAYATHNAGAR ST NO 14 40 HYDERABAD TELANGANA 500029 | HYDERABAD | TELANGANA | 500029 | - | Not Admitted-Fee Fee not received |
Tender Value
₹11.4 L
EMD Value
₹22,807
Closing Date
6 Dec 2019, 6:00 pmClosed
Assistant General Manager Engg-Elect
Assistant General Manager Engg Elect, AAI, Tirupati Airport, Renigunta 517 520
SITC of ILBS System at Various Airports in India. SH Provision of Internal Electrification and Air Conditioning works for ILBS System at Tirupati Airport.
2019_AAI_35848_1
AAI/TPT/ENGG(E)/C-11/19-20
Open Tender
Electrical Works
Item Rate
90 days
Tirupati Airport
Please refer Tender documents.
16 documents required · 16 mandatory
₹1,180
Yes
Airports Authority of India
₹22,807
Yes
3 Jan 2020
18 Nov 2019
12 Dec 2019
19 Nov 2019
6 Dec 2019
26 Nov 2019
19 Nov 2019 - 22 Nov 2019
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 1 X 6 sq. mm + 1 X 10Sq.mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 nos. 3 pin 5/6 amps modular socket outlets and 3 nos 5/6 amps modular switches, connection etc. as required
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps, 10kA “C” curve, TPNMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way Double Door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
Supplying and fixing of 36W LED ceiling mounted Panel fitting including Driver, suitable to work with 220-250V, 50 Hz AC, CCT of 5700K, efficacy of Minimum 100 Lm/W, P.F>0.95 and THD of <10% and meeting the Technical specifications as required.
Supplying and fixing of 42W LED surface mounted Panel fitting including Driver, suitable to work with 220-250V, 50 Hz AC, CCT of 5700K, efficacy of Minimum 100 Lm/W, P.F>0.95 and THD of <10% and meeting the Technical specifications and including all accessories required for fixing complete etc. as required.
Supplying and fixing of 50W LED die cast alluminium flood light with high power LED as light source for area lighting with in built Driver, suitable to work with 220-250V, 50 Hz AC, CCT of 5700K, efficacy of Minimum 100 Lm/W, P.F>0.95 and THD of <10% and meeting the Technical specifications and including all accessories such as supply and fixing of suitable MS angle arrangement for fixing of fixture complete etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supply of 1.0TR Inverter type Split Air-Conditioner of BEE 5 Star rating Hi-wall split 1.0 Ton non ductible fan coil unit (Indoor Unit), Copper Condensing unit (Outdoor Unit) with fan and High Energy Efficiency Ratio Rotary compressor, with cord less remote controller and works with R410A/R32/R 134A gas, suitable for operation on 1 Phase, 230 +/- 10%V, 50Hz AC supply etc. complete as required. The supply of unit shall include the copper pipings, Interconnecting Power cables between the Indoor and Outdoor Unit as per the standard manufacturer design (i.e. Copper pipings of not less than 3 Mtrs) including drain pipe and initial charge of gas etc. complete as required.
Supply of 1.5TR Inverter type Split Air-Conditioner of BEE 5 Star rating Hi-wall split 1.5 Ton non ductible fan coil unit (Indoor Unit), Copper Condensing unit (Outdoor Unit) with fan and High Energy Efficiency Ratio Rotary compressor, with cord less remote controller and works with R410A/R32/R 134A gas, suitable for operation on 1 Phase, 230 +/- 10%V, 50Hz AC supply etc. complete as required. The supply of unit shall include the copper pipings, Interconnecting Power cables between the Indoor and Outdoor Unit as per the standard manufacturer design (i.e. Copper pipings of not less than 3 Mtrs) including drain pipe and initial charge of gas etc. complete as required.
Supply of 2.0TR Inverter type Split Air-Conditioner of BEE 3 Star rating Hi-wall split 2.0 Ton non ductible fan coil unit (Indoor Unit), Copper Condensing unit (Outdoor Unit) with fan and High Energy Efficiency Ratio Rotary compressor, with cord less remote controller and works with R410A/R32/R 134A gas, suitable for operation on 1 Phase, 230 +/- 10%V, 50Hz AC Supply etc. complete as required. The supply of unit shall include the copper pipings, Interconnecting Power cables between the Indoor and Outdoor Unit as per the standard manufacturer design (i.e. Copper pipings of not less than 3 Mtrs) including drain pipe and initial charge of gas etc. complete as required.
Installation, Testing and commissioning of 1.0/1.5/2.0 TR wall mounted/Hi-wall type Split Air-Conditioner by making required structures of suitable size MS stand/PCC work as per site requirement i/c balancing of Liquid & Gas, Gas charging the system with R410A/R32/R 134A refrigerent if any extra gas required due to increase in length of Copper piping, including covering the Copper piping (i/c Copper pipe came along with the units) with suitable size casing capping/PVC pipe Lifting / Shifting of Outdoor & Indoor units upto site location etc., complete as required.
Supply, Laying and connecting of OEM recommended copper refrigerent Piping(Liquid and Gas) with Nitrile Rubber insulation of thickness not less than 13mm and with all other accessories suitable for 1 phase, 1.0/1.5TR split AC including covering the Copper piping with suitable size casing capping/PVC pipe etc. complete as required (Length of Liquid and gas line will be measured as single measurement).
Supply, Laying and connecting of OEM recommended copper refrigerent Piping(Liquid and Gas) with Nitrile Rubber insulation of thickness not less than 13mm and with all other accessories suitable for 1 phase, 2.0TR split AC including covering the Copper piping with suitable size casing capping/PVC pipe etc. complete as required (Length of Liquid and gas line will be measured as single measurement).
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps, 10kA "C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commisioning etc. as required.
Supply, installation, testing and commissioning of wall mounting type, 4 KVA Capacity, single phase, automatic line voltage stabilzer, suitable operation on 170 volts to 270 volts AC input, 200 volts to 240 volts AC output, single phase, 50Hz AC power supply with built in time delay, high voltage cut off, and low voltage cut off at 145 volts and input/output/trip indications and suitable for application of 1.5 TR/2.0 TR Air conditioning unit etc. as required (As per list of approved makes).
Supply of XLPE insulated, PVC sheathed aluminium conductor armoured power cable of 1.1KV grade confirming to IS 7098 (Part I) 1978 with upto date amendments etc as required for the following sizes.(Make : As per approved list.) a) 4C X 16 Sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. a)Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable 1.1KV grade of following size on surface as required. Up to 35 Sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable 1.1KV grade of following size on cable tray as required. Up to 35 Sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3X4 Sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required 4 X 16 Sq.mm
Supply and laying/fixing of ISI marked CPVC pipe of 25mm dia with required bends/connectors on surface/suspension for draining out the water including interconnection of drain pipe etc. complete as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
CHENNAI ENGINEERING SERVICES
DEEPAKELECTRICALS
KALKI ELECTRICALS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .