Loading…
Loading…
Tender Value
₹32.2 L
EMD Value
₹32,200
Closing Date
9 Jul 2026, 3:00 pmClosed
Chief Engineer, TTD, Tirupati
D.E(Elec)-II, Room No.128, TTD Admn. Bldg., Tirupati
AMC UPS systems in SPMC Hospital, SP Medical Coillege, Tirupati for three (3) years 2026-27 to 2028-29
950752
150/DE(Elec)-II/TTD/TPT/2026-27
OPEN - NCB
Electrical Works
CHITTOOR
6 documents required · 6 mandatory
₹1,139
₹32,200
11 Jul 2026
24 Jun 2026
24 Jun 2026
Per Month Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 2 KVA to 3 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). UPS 2 Nos x 3 yearsx12 Months = 72 Nos
Per Month Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 4 KVA to 6 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). 5 Nosx3 yearsx12 Months = 180 Nos.
Per Month Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 7.5 KVA to 10 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). 2 Nosx3 Years x 12 Months =72Nos
Per Month Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 15 KVA to 20 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). 3 Nosx3 yearsx12 Months =108 Nos.
Per Month Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 25 KVA to 30 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). UPS 5 Nos x 3 years x12 Months = 180 Nos
Per Month Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 40 KVA to 50 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). UPS 4 Nos x 3 yearsx 12 Months = 144 Nos
Per Month Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 60 KVA to 75 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). UPS 1 No x 3 years x 12 Nos = 36 Nos
Only Labour / Engineering Supervision Service Charges KVAfor dismantling, shifting one place to another place in samecity and Re-lnstallation work UPS systems with battery bank.
Supply of 12 stage APFC relay for APFC panels.
Supply and Fixing of AMF Relay Suitable for AMF Panel of 100 to 750 KVA DG Set
Supply of Fixing of DC Filter Capacitors 2.5 Kmfd to 10 Kmfd 1 set ( 3 Nos.) 120 V to 400 V DC Operating System 10 to 30 kVA ON-LINE UPS System
Per Month Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel (Capacitor Duty Contactor type) 100 to 200 KVAR and lnclusive of all Spares Cost for Replacement of During AIVIC Period, such as timers contactors, fuses, indicators, MCBs, Capacitor Duty contactors etc., complete ( Except APFC relay, Capacitors, l00A and above main incomer MCCB/ SFDU switche. 4 Nos of panels x 3 years x12 Months = 144 Nos
Per Month Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG Set 100KVA to 750KVA) and inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers, Contactors, fuses, indicators, MCBs, etc, complete (Except AMF Relay, 100A and above main incomer contactors / MCCB / ACB switch etc.) 3 Nos of panels x 3 yearsx12 Months = 108 Nos
Supply and fixing of 12V, 26AH SMF battery with 3 years warrenty,including wire leads, connections ect complete., (with buy back offer of old existing batteries) Make: Quanta/ Racket/ Exide.
Supply and fixing of 12V, 42AH SMF battery with 3 years warrenty,including wire leads, connections ect complete., (with buy back offer of old existing batteries) Make: Quanta/ Racket/ Exide.
Supply and fixing of 12V, 65AH SMF battery with 3 years warrenty,including wire leads, connections ect complete., (with buy back offer of old existing batteries) Make: Quanta/ Racket/ Exide.
Supply and fixing of 12V, 100AH SMF battery with 3 years warrenty,including wire leads, connections ect complete., (with buy back offer of old existing batteries) Make: Quanta/ Racket/ Exide.
Supply and fixing of 12V 120/130 AH SMF battery with 3 years warrenty including wire leads,connections etc complete., (with buy back offer of old existing batteries) Make: Quanta/ Racket/ Exide.
conditions:a) Contract will be executed between two parties after confirming to AMC order. b) Preventive maintenance will be carried out once in a month. c) The AMC charges are inclusive of all spares and any spares are replaced during the contract period will be the property of company, batteries are treated as consumables for the same reasons not replacement warranty during AMC period but maintenance covered during AMC period. d) All break down calls, complaints will be attended to immediately. Note:- The service reports must be sent to O/o.Divisional Engineer(Elec.)-II and concerned Dy. Exe.Engineer(Elec.)-SBH & AE TTD soon after each service.
(Rupees Thirty Two Lakh Fifteen Thousand Five Hundred Thirty Five and Paise Thirteen only)
stage.html
html • 0.01 MB
aoc.html
html • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.01 MB
NIT 150.docx
TENDER_DOCUMENT • 0.16 MB
Schedule 150.xls
TENDER_DOCUMENT • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].