Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹23.3 L+₹82,998.48 (3.70%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹23.3 L+₹82,998.48 (3.70%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹23.3 L+₹84,961.66 (3.78%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L4 | Rejected-Finance Other than Lowest bidder | |
| 5 | L5₹23.9 L+₹1.5 L (6.47%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹26.2 L
EMD Value
₹52,400
Closing Date
18 Nov 2020, 6:00 pmClosed
GE AFS TEZPUR
GE AFS TEZPUR, PO- SALONIBARI, DISTT- SONITPUR, ASSAM-784104
Outsourcing for manning and operation of pump house No 05 and sewage Pump House No 01, 02 and 04 and other electrical works at AF Station Tezpur under GE (AF) Tezpur
2020_MES_377097_3
8521/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
TEZPUR
Class D Cat d(v)
8 documents required · 8 mandatory
₹500
Yes
GER AFS TEZPUR
₹52,400
Yes
21 Nov 2020
3 Nov 2020
20 Nov 2020
3 Nov 2020
18 Nov 2020
3 Nov 2020
3 Nov 2020 - 3 Nov 2020
Amount
Outsourcing for operation of installations at Pump House No 05 with min one operator per shift (semi skilled), in three shifts per day of 8 hours each, for seven days in a week. The installation consists of following machineries for water supply including operation of all outgoing / incoming valves & pipe lines all as directed. (a) (a) Bore well with submersible of pumping set capacity 15 HP, 415 Volts 50 Hz, Make : KSB-01 No. (b) Booster pump of mono block/centrifugal type with electric motor of cap-15 HP 415 Volts. 50HZ - 02 Nos. (c) Liquid chlorine dozing machine - 01 No (d) Oxidation chamber with motor operated compressor -01 No (e) Oxidation chamber pre-filter, iron removal plant-01 No (f) DG set with electric control panel - 01 No. In addition to above, the operator shall be responsible for switching ON/OFF of the street lights/High mast lights within the 500M distance of installation. The switching ON/OFF timing provided by the Eng- in- charge. Note : (i) Rate quoted against item no 1.1 to 1.6 shall be inclusive of all taxes, cess, levies as applicable and GST (ii) Payent against each item (1.1 to 1.6) will be released only after submission of authentic document as proof of payment.
Basic rate including Dearness allowance NOTE : (i) Quoted rate shall not be less than the min wage (higher of min wage published by center / state as on the last date of bid submission end date) (ii) The quoted rate is inclusive of employee contribution of EPF and ESI as per EPF act 1952 and ESI act 1948, as ammended from time to time
EPF (Employer contribution as per EPF act 1952, as ammended from time to time) current contribution is 13 %
ESI (Employer contribution as per ESI act 1948, as ammended from time to time) current contribution is 3.25 %
Contribution towadrs Bonus (as per Bonus act 1965, as ammended from time to time) current contribution is 8.33 % of gross salary
Overhead and profit
Labour welfare cess (min 1%) on sum of Basic, EPF, ESI ,Bonus and profit.
Outsourcing for Operation of Non clog sewage pump electrically driven with motor of capacity 10HP, 415 Volt, 50Hz Make: Kirloskar - 01 and non clog sewage pump electrically driven with motor of capacity 5 HP, 415 volt, 50 Hz Make : Kirloskar-01 No (for Sewage PH No 2), & Non clog sewage pump electrically driven with motor of capacity 15 HP 415 volt, 50 Hz Make : Kirloskar-02 Nos for (Sewage Pump No 4) in two shift per day for 8 hrs each shift for seven days in a week with min one operator (Semi skilled) per shift alongwith sewage pumps of under mentioned capacity working (Only One pump running at a time other remain standby) all as directed by Engr-in-Charge. In addition to above, the operator shall be responsible for switching ON/OFF of the street lights/High mast lights within the 500M distance of installation. The switching ON/OFF timing provided by the Eng- in- charge. Note : (i) Rate quoted against item no 2.1 to 2.6 shall be inclusive of all taxes, cess, levies as applicable and GST (ii) Payent against each item (2.1 to 2.6) will be released only after submission of authentic document as proof of payment.
Basic rate including Dearness allowance NOTE : (i) Quoted rate shall not be less than the min wage (higher of min wage published by center / state as on the last date of bid submission end date) (ii) The quoted rate is inclusive of employee contribution of EPF and ESI as per EPF act 1952 and ESI act 1948, as ammended from time to time
EPF (Employer contribution as per EPF act 1952, as ammended from time to time) current contribution is 13 %
ESI (Employer contribution as per ESI act 1948, as ammended from time to time) current contribution is 3.25 %
Contribution towadrs Bonus (as per Bonus act 1965, as ammended from time to time) current contribution is 8.33 % of gross salary
Overhead and profit
Labour welfare cess (min 1%) on sum of Basic, EPF, ESI ,Bonus and profit.
Outsourcing for Operation of Non clog sewage pump electrically driven with motor of capacity 10HP, 415 Volt, 50Hz Make: Kirloskar - 03 Nos installation in sewage Pump House No1 min one operator per shift (semi skilled), in one shifts per day of 8 hours each, for seven days in a week. (Only One pump running at a time other remain standby) all as directed by Engr-in-Charge. In addition to above, the operator shall be responsible for switching ON/OFF of the street lights within the 500M distance of installation. The switching ON/OFF timing provided by the Eng- in- charge. Note : (i) Rate quoted against item no 3.1 to 3.6 shall be inclusive of all taxes, cess, levies as applicable and GST (ii) Payent against each item (3.1 to 3.6) will be released only after submission of authentic document as proof of payment.
Basic rate including Dearness allowance NOTE : (i) Quoted rate shall not be less than the min wage (higher of min wage published by center / state as on the last date of bid submission end date) (ii) The quoted rate is inclusive of employee contribution of EPF and ESI as per EPF act 1952 and ESI act 1948, as ammended from time to time
EPF (Employer contribution as per EPF act 1952, as ammended from time to time) current contribution is 13 %
ESI (Employer contribution as per ESI act 1948, as ammended from time to time) current contribution is 3.25 %
Contribution towadrs Bonus (as per Bonus act 1965, as ammended from time to time) current contribution is 8.33 % of gross salary
Overhead and profit
Labour welfare cess (min 1%) on sum of Basic, EPF, ESI ,Bonus and profit.
Outsourcing for attending day to day maintenance of internal electric breakdown as light , fan, switches, sockets points etc. at SMQ ,OMQ and Tech area of AIR Force Stn in one shift for 08 hrs each for 06 days in a week with min three electrician ( skilled) and one helper (unskilled) per shifts comprising of checking, testing, taking out and replaceing of switches, sockets, light fittings, starter, choke, lamp holder, MCBs, isolator, DBs & damaged wiring etc. and making serviceable all as directed Note:- (i) Electric fittings/fixtures shall also be issued by the department for replacement of diffectives/ fittings free for fixing. (ii) Any type of complaints related to internal electrification shall be attended of againsted of this item (iii) Immediately on report of complaint, trade man and helper shall proceed to attend the complaints after attending the complaints,user completion report shall be submitted to JE concern. (iv) Old material retrived during requirment/rectifcation shall be deposted by the contractor in the store yard of AGE E/M as the old material shall be the Govt. Property. (v) Rate quoted against item no 4.1 to 4.6 shall be inclusive of all taxes, cess, levies as applicable and GST (vi) Payent against each item (4.1 to 4.6) will be released only after submission of authentic document as proof of payment.
Basic rate including Dearness allowance NOTE : (i) Quoted rate shall not be less than the min wage (higher of min wage published by center / state as on the last date of bid submission end date) (ii) The quoted rate is inclusive of employee contribution of EPF and ESI as per EPF act 1952 and ESI act 1948, as ammended from time to time
EPF (Employer contribution as per EPF act 1952, as ammended from time to time) current contribution is 13 %
ESI (Employer contribution as per ESI act 1948, as ammended from time to time) current contribution is 3.25 %
Contribution towadrs Bonus (as per Bonus act 1965, as ammended from time to time) current contribution is 8.33 % of gross salary
Overhead and profit
Labour welfare cess (min 1%) on sum of Basic, EPF, ESI ,Bonus and profit.
One bottle of treated water (filtered water) and One bottle of untreated water (ground water) collected from different pump houses of GE (AF) Tezpur are forwarded herewith as sample for iron contents with standards of quality for drinking water at Defence Research Laboratory (DRL) Tezpur (Assam) and putup the certificate to Engineer-in-charge ones in a contract period complete all as specified and as directed .
Disconnections of electric connection of pumping Set, of cap 10 HP motor 3 phase 415 volts, lifting and removing motor form its existing foundation to the location (inside/outside of buildings) where directed by the Engr-in-charge. Dismantling the motor carefully, checking. Segregating serviceable and unserviceable parts, cleaning the serviceable parts thoroughly by approved method (Part like stator, rotor, terminal box, bearings, shaft, key etc) heating,drying and varnishing including replacement of burnt windiwng with super enameled copper wire of existing gauge and good quality of insulating materials including replacement of unservicealbe parts as required (New part shall be measured and paid saperately as supply only) re-assembling the motor installing to its existing foundation, commissioning, connected up and testing complete as directed .
All as per item srl No 06 here-in-before but for 5 HP Motor, 3 Phase, 415 Volt Make: Kirloskar
All as per item srl No 06 here-in-before but for 15 HP Motor, 3 Phase, 415 Volt Make: Kirloskar
Disconnecting pump from motor and suction, delivery, lifting and removing from its existing foundation to the location (inside/out side building) as directed by the Engr-in-Charge, dismantling carefully the pump completely checking and segregating serviceable and un-serviceable parts, cleaning/washing and servicing (including metal ling, machining facing) the serviceable part by approved method, replacing unservicealbe parts, (new parts required to be measured and paid saperatelly under relevent items) reassembling the pump completely installing to its existing foundation, commissioning, connecting up and testing complete for the pumps of cap 10000GPH AT a head of 100 feet. Make : Kirloskar (Note : Spare part shall be measured and paid seperately under relevent items No 10 to 18).
Supply only Ball bearing No 6308 Make: NBC/SKF/TATA
Supply only Ball bearing No 6306 Make; NBC/SKF/TAT
Supply only Shaft Key of Size
Supply only Type coupling bolt/stud of size Make : PBE
Supply only Type/ Rubber coupling No PX45 Make: Universal/Unique
Supply only Tyre/rubber coupling type D-60/70/80 Make Dunlop/ Unique
Supply only Tyre coupling flange PX45 or PX50
Supply only Tyre coupling flange PX60 or PX80
Supply only Star coupling as per sample
Supply only GI screw bolts (machine made) with hexagonal or square heads at one end and screwed the other each screwed end to be fitted with washer and one hexagonal or square nut, exc 5cm but not exc 10cm long and dia of neck 15mm to 25mm.
Taking out 100mm bore GI suction pipe with check valve of non clog sewage pump and cleaning both pipe and check valve by wire brush properly, refilling to its existing position complete all specified and as directed.
Taking out 200mm bore GI suction pipe with check valve of non clog sewage pump and cleaning both pipe and check valve by wire brush properly, refilling to its existing position complete all specified and as directed.
Supply and fix as in repair GI Bend, medium grade, ISI marked of size 100mm dia including Nut, bolt and washers complete all specified and as directed.
Supply and fix as in repair GI Tee, medium grade, ISI marked of size 100mm dia including Nut, bolt and washers complete all specified and as directed.
Supply and fixing in repair fully automatic star delta mono block/centrifugsl motor starter for 15 HP, 415Volt,. 50Hz, 3 ph motor. Cat No: SS94362 Including taking down unserviceable exiting Stater of Make:L&T or equivalent make HPL/Havells
Supply and fix in replacement 150mm bore cast iron sluice valve with flanged ends heavy duty class PN-1.0, ISI marked, drilled holes for bolt, comprising of SS spindle and cast iron operated handle including necessary rubber gasket joint with nut and bolts complete all as specified and directed.
Supply and fix in Replacement 100mm bore cast iron sluice valve with flanged ends heavy duty class PN-1.0, ISI marked, drilled holes for bolt, comprising of SS spindle and cast iron operated handle including necessary rubber gasket joint with nut and bolts complete all as specified and directed.
Supply and fix in Replacement 80mm bore cast iron sluice valve with flanged ends heavy duty class PN-1.0, ISI marked, drilled holes for bolt, comprising of SS spindle and cast iron operated handle including necessary rubber gasket joint with nut and bolts complete all as specified and directed.
M&L as in repair to leaking joint for cast iton, spigot and socket pipes and fitting, 150mm bore in water mains, by burning out old lewad joints in position including provn of run lead, including necessary excavation earth work, returning filling complete all specified and as directed.
All as per item srl No 28 here-in-before but for 100 mm bore
All as per item srl No 28 here-in-before but for 80 mm bore
Lifting up the submersible motor and pump by disconnecting star delta connection from starter with the help of chain pulley and disconnection the GI colum pipe by opening nut and bolts and replacement of old rusted GI Column Pipe heavy grade of size 100 mm dia in pieces of 3.3 meter long, both ends flanged in the bore/open wells and joining the GI column pipe by providing 5mm thick rubber gasket, nuts and bolt and lowering down pump set with the help of chain pulley, connecting electrical star delta connection to starter, testing complete all as specified and directed.
M/S L N ENTERPRISE
KAILSON
M/S N G CHOWDHURY
Raj Enterprise
M/S JALALUDDIN AHMED
Singhs Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .