GE DEHRADUN
GE DEHRADUN, MALL ROAD, GARHI CANTT
Completion of incomplete works in respect of spl repair to Bldg No. T-4 and T-5 (four nos offrs qtrs) at Birpur, Bldg no. P-14 and P-15 (08 nos qtrs) of FAFA Cheerbagh, P-40 (captain Md Accn) behind gas agency at SP Road and certain revenue work unde
2020_MES_350396_1
8204/A/E8
Open Tender
Civil Works
Item Rate
90 days
GE DEHRADUN
Class Cat a(i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹54,400
Yes
9 Sept 2020
6 Jun 2020
6 Jul 2020
6 Jun 2020
4 Jul 2020
20 Jun 2020
60 days
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L for brick work with non modular fly ash lime brick (FALG bricks) conforming to IS 12894 class designation 10 average compresive strength on curve on plain exc 6m mean radious built in cement mortar (1:6) complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) (using old size bricks) (except bricks) bricks shall be obtained from item No 1.00)
Taking down cement or cement lime plaster on walls any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L for rendering 10 mm thick on ceiling in cement mortar (1:4) finished fair & even complete all as specified and directed.
M & L rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound finished fair faces of brick/concrete surfaces even and fair without using extra cement . The work will be carried out upto double storey building the rate of scafolding shall be deemed to be included for this item also (WPC will be measured and paid separately).
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick or concrete work, rendering is to be finished fair & even complete all as specified and directed.
Supply only integral water proofing compound complete all as specified & directed.
M&L applying silicon based water proofing chemical by spray on walls complete all as specified & directed
M&L for coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with colour pigment to match laid over and including screed bed 15mm thick in CM (1:6) complete all as specified and as directed including dismantling of floor tiles complete.
M&L for glazed ceremic coloured tiles 200x300x7 mm as in dado set & jointed in neat cement slurry and pointed in which cement mixed with colour pigment to match coloured tiles including 10mm thick screed bed (backing layer) cement mortar (1:6) for fixing of tile complete all as specified and directed including dismantling of tiles complete.
All as per item No. 11.00 here in above but size of tiles 350x250x7mm/ 450x350x7mm
M&L for coloured Non Skid Ceramic tiles in vertical surfaces of 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.16 sqm over and including 10mm thick bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed including dismantling of tiles complete.
M&L for light shade vitrified tiles of 10 mm thick, double charged (square or rectangular) polished area of each tiles exceeding 0.36 sqm but n.exc 0.42 sqm in floor set and jointed in neat cement slurry and pointed in white cement mixed with coloured pigment to match the shade of tiles with & including 15mm thick screed bed or bedding layer of in cement mortar (1:6) complete all as specified and directed including dismantling of tiles complete.
M&L for light shade vitrified tiles of 10 mm thick, double charged (square or rectangular) polished area of each tiles exceeding 0.09 sqm but n.exc 0.12 sqm (cut from 600x600mm/605x605mm tiles ) as in skirting/dado set and jointed in neat cement slurry and pointed in white cement mixed with coloured pigment to match the shade of tiles with & including 10mm thick screed bed or bedding layer of in cement mortar (1:4) complete all as specified and directed including dismantling of tiles complete.
M&L Udaipur green stone for flooring slabs 12-15mm thick laid over 15 mm thick cement screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with coloured pigments to match the shade of the slab including rounding of edges of stone including demolition of old stone slab complete all as specified.
M&L for 20-25mm thick machine cut Kota stone slab as in flooring over an including 15 mm thick screed bed in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed including dismantling of stone slab flooring.
M&L for machine cut Kota stone slab 18 to 20mm thick, in riser of steps, skirting, dado etc. over & including 10mm thick rendering (bedding layer) in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, rounding of edges and polishing complete including dismantling of stone slab.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection, finishing the surface even & fair without using extra cement the plinth protection shall be laid in alternate bays n exe 2 Sqm, 10mm joints shall be provided, joints shall be filled with bitumen mastic, bitumen mastic comprise of 1 Part of Hot bitumen 85/25 grade and 3 parts of sand all by weight complete all as specified & directed including demolition of concrete complete.
M&L for 40mm thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in flooring, finished even and smooth using extra cement, The floor shall be laid in alternate bays nexc 4sqm, and divided in to glass dividing strip, complete all as specified.(Glass dividing strip shall be measured and paid separately) including demolition of concrete complete.
Supply only glass dividing strips, 3 mm thick 38 mm with inserted in position to confirm to design.
M & L for cement concrete ( 1:3:6 ) type C1 (using 20 mm graded stone aggregate) as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement and necessary form work. (Note : Forming fair finished channel for drain using extra cement will be measured and paid for separately) including demolition of concrete complete.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc
M&L PCC (1:2:4) type B-0 (using 12.5mm graded aggregates) as in roof kerbs/ benching/covered fillets etc rounded and chamfered on edges, complete all as spd and directed including demolition of concrete complete.
M&L for RCC (1:1.5:3) type A-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landing balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed including demolition of concrete complete.
M&L RCC (1:1.5:3) type A-1 (using 20mm graded stone aggregate) as in chajjas and like etc. complete all as specified and directed including demolition of concrete complete.
M&L for use and waste form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar works, not exceeding 200mm thick for rough finished surfaces of concrete complete all as specified and directed.
M&L use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges etc complete all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs ( for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary form work, set in cement mortar 1:6 complete all as specified and directed. (Reinforcement shall be measured and paid for separately under respective item of schedule 'A') including demolition of concrete complete.
S&F mild steel TMT bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia as specified .
Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each and removing from site complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame) and removing from site complete all as specified and directed.
Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frame) and removing from site complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together withglue pinned at joints complete complete all as specified and directed.
M&L 2nd class Hard wood plain fillets sectional area exc 13 & n exc 25 Sqcm Square or rectangular in section, wrought, secured with nails or barbs complete all as specified and directed.
M&L for 35mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. without sash bar edges of framing moulded, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) complete all as specified.
M&L 35mm thick 2nd class hard wood factory made plain framed panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS:1003 (Part1), kiln seasoned and chemically pressure treated, all as specified and directed.
M&L 30mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified.
M&L 30mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified.
S&F factory made pre laminated PVC flush type shutter of 18mm (+ 0.5) thickness consisting of panel of 18mm (+0.7mm) thick celluca ply, of denistity 600 Kg per cum manufactured by ISO-9000 certified company, using for shutter celluca ply 18mm thick and fixed with frame, all four edges of shutters, using 13/6 size self tapping steel screws. The thickness of shutter is edges painted by matching colour of PVC lining of prelam coloured PVC sheet using etc, complete as per manufactue specification.
S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.
S&F pre laminated Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam single piece extruded pvc profile and edgs will be painted to match with prelam sheet,PVC sheet are to be reinforced with 19x19mm MS square tube EPDM rubber gasket weather seal shall be provided through out the frame. The profile shall be mitre cut at two corners and joint by insrting 2 nos of 150mm long backets of 15mmx15mm MS square tube inside the 19mmx19mm MS square tube and suitably screwed and fixing in opening as per specification & drawing.
S&F Factory made pre laminated solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with single piece extruded pvc profile both side prelam PVC sheet 'C' channel having a 5mm thick PVC sheet strip of 20mm width stuck inside with solvent cement, forming stiles, and 5mm thick both side prelam single piece extruded pvc profile for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of both side prelam 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and shown on drawing given in SSR Part II. The width of stiles & rails shall be in proportion to the width of the door shutter as given in SSR Part I.
S&F factory fabricated steel window with side hung shutter (double shutter) external shutter shall be provided glazing bar and internal shutter shall be without glazing bar (mosquito proofing) steel window provided with box type hinges, guard bar/grill 10mm square bar shall be provided in external frame, 2 nos peg stay shall be provided with external shutter, 2 nos MS handle shall be provided each shutter, steel window shall be provided with shop coat painting before fixing, all welding shall be flush butt welded, steel window shall be procured from IS approved manufacturer, steel window shall be manufactured as per TD drawing including taking down old steel window.
S&F factory fabricated steel ventilators, top hung shutter, with box type hinges steel peg stay handle complete.
S&F framed work as in doors and gate of angle and other section with gusset plate, rails, braces etc and other similar works and including either hooks and hinges or steel hanging door fittings complete, conforming to Fe-410 W Gde E-250 quality 'A' all as specified including dismantling of old door/gate and removing from site.
M&L mild steel butt hinges, medium weight 100 mm size (including welding to steel chowkhats) ISI marked.
S&F 100 mm size cadmium plated stainless steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F 200 mm long, aluminium, anodised, barrel tower bolts of extruded section ISI marked complete all as specified and directed.
S&F 150mm size aluminium handles,cast type,anodised all as directed ISI marked complete all as specified and directed.
S&F 125mm size aluminium handles,cast type,anodised all as directed ISI marked complete all as specified and directed.
S&F mild steel 300mm long, ordinary rat rail rod pattern spring including roller and roller plate (Helical door spring) for door shutter.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flap (when open) 30 mm complete all as specified and directed.
S&F Hasp and staple 75mm safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staple complete all as specified and directed.
M&L for preparation of new or previously untreated wooden surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
M&L for preparation of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F 3 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sqm in each pane complete all as specified.
M&L sheet glass ordinary quality 3mm thick, glazing with oil putty in squares n.exc 0.50 sqm each pane complete all as specified and directed.
S&F in repair 25 mm dia mild steel drapery rod with wooden finish, decorative, including brackets, decorative finials at both ends & curtain rings 8 Nos (minimum complete all as speccified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal from site with all fittings for 15 mm bore GI tubing complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal from site with all fittings for 20 mm bore GI tubing complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with all new fittings to floor, wall or ceiling as directed, for 15 mm bore GI tubing.(Pipe shall be obtained from item No 62.00 here in above)
Refixing of old steel tubing and connections in new or old position with all new fittings to floor, wall or ceiling as directed, for 20 mm bore GI tubing.(Pipe shall be obtained from item No 63.00 here in above)
M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth.
S&F galvanised steel water tubing medium grade (ISI marked) with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing.
S&F galvanised steel water tubing medium grade (ISI marked) with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing.
S&F in repairs PVC valve less, syphonic action type low level flushing cistern, white with inlet ball valve , float handle , including brackets 10 ltr capacity, including flush pipe all as specified .
S&F in repairs PVC connection 15mm size with PTMT nuts, of 450 mm long.
S&F rotational moulded polyethylene 500 Ltrs capacity water storage tanks (cylindrical vertical with closed top) three layer, ISI marked hoisted and fixed in positionas specified in SSR Part-I including 20mm dia PTMT ball valve 20mm dia GI medium grade over flow pipe 1.5 mtr length (approx), 25mm dia GI wash out pipe plugged at one end complete all as specified and directed including dismantling of old tank complete.
S&F in repair chromium plated bib taps long body, fancy type, with round headed knob with wall flange screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. Make:- Jaquar continental model No. CON107KN/Pearl ARI 003/Marc cat No. ES511B
S&F in repair stop valve 20 mm nominal bore, brass, screwed down high pressure with cluch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F in repair 15 mm dia brass chromium plated bib taps, short body, wall flange, fancy type, with round headed knob screwed down to GI pipes or for brass ferule or to GI socket complete all as specified and directed. Make:- Jaquar model continental cat No. CON 047KN/Marc ESSCO ES 508/ PEARL ARI 001
S&F in repair Angle cock, brass chromium plated, fancy type, with wall cap with round headed knob, suitable for 15mm bore iron pipe complete all as specified. Make:- Jaqar cat No. CON 059KN/Mark ESSCO ES 526/Pearl ARI 004.
S&F in repair CP shower rose 100mm dia, swivel type, with cp arm, suitable for 15mm dia GI pipe Make:- Marc cat No. ES 549 & ES 536 Pearl SHP 525 & SHA 512 Cera cat No. CG 416A & CH 103
S&F in repair concealed stop cock, fancy type, brass chromium plated with round heeaded knob suitable for 15mm bore iron pipe, complete all as specified. Make:- Jaquar CON083KN/Marc ES 514/Pearl ARI-0009
S&F in repair 20 mm dia brass chromium plated tubular towel rail 'D' type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
S&F in repairs peg set of Three, cromium plated, back plate including chromium plated fixing screw complete all as specified and directed.
S&F in repairs CP brass Soap dish fixed to wall with chromium plated, brass screwed and cup washer.
S&F in repairs PVC Shelves of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms)
S&F in repairs plate rack of size 600x750x250 mm made out off 1.00 mm thick stainless steel sheet fixed to wall with brass screws complete all as specified and as directed.
S&F in repair stainless steel sink with draining board made out of 1mm thick sheet kitchen or laboratory with plugs, washers including beding lime cement mortar to dwarf wall or including fixing cantilever brackets fixed to wall and connecting union to pipe overall size 914x460x203mm bowl size 405x354x203 mm complete all as specified and directed.
S&F in repair vitreous china water closet (squatt pan) orrisa pattern 580 x 440 mm size pan white with front or back inlet with integral ' foot rests includinhg provn of lime concrete bedding including connections to ' flushing cistern/ pipe complete including 100 mm CI 'P' trap/'S' trap complete all as specified and directed.
S&F in repair vitreous china, white, wash hand basin, flat back size 550x400mm 'including MS brackets including cutting for and pinning in, including with 32mm (PTMT) waste coupling (half or full threaded) minimum weight 32gm -45gms) & 15mm bore CP pillar tap supply only 25mm dia PVC (LDPE) of pressure 6Kg/cm2 down pipe 75cm long as waste pipe complete all as specified and directed. Make of pillar tap Jaquar CON 011KN/Marc ESSCO ES 507/Pearl Aries ARI 002
S&F 100mm dia cast iron soil and waste pipe (sand cast) in any length with or with ears, with cement joints laid in trenches or in floors complete all as specified including taking down old unserviceable CI pipe.
All as per item No. 87.00 here in above but fixed on wall with flat iron MS clamp 25mmx5mm and holder bats, complete all as specified and directed by Engr-in-charge.
S&F 75mm dia (sand cast) cast iron soil and waste pipe in any length with or with ears, with cement joints laid in floors complete all as specified including taking out old unserviceable pipes.
All as per item No. 89.00 here in above but fixed on wall with FI MS clamp 50x5mm holder bats.
S&F in repair UPVC (SWR) pipe 110 mm dia, any radius jointed with approved adhesive complete all as required and as directed.
S&F in repair UPVC (SWR) bends of 110 mm dia complete all as specified and directed.
S&F in repair cast iron bends any radius for 100 mm dia pipe dia with duck 's foot or heel rest .
S&F in repair cast iron bends any radius for 75 mm dia pipe with duck 's foot or heel rest .
S&F in repair cast iron bend (any radius) of 75mm bore with oval access door.
S&F in repair 75mm dia cast iron cowls.
S&F 100mm dia CI branch piece, (single equal or unequal) (spigot & socket type) complete all as specified and directed ordinary or inverted or with parallel branches.
S&F 75mm dia CI branch piece, (double equal or unequal) (spigot & socket type) complete all as specified and directed ordinary or inverted or with parallel branches.
S&F in repair cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door of 100 mm bore with oval access door complete all as specified and directed.
S&F 75 mm dia cast iron floor trap, with CP grating including jointing to waste pipe with solvent cement and fixed in cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed.
M&L applying wall putty 2 to 3 mm thick, and rubbing with sand paper to make the surface smooth complete all as specified.
Preparing newly plastered surfaces of walls and applying two coats of Cement based paint over one coat of primer complete all as specified.
Preparing old plastered surfaces of walls and applying one coat of Cement based paint complete all as specified.
M&L for applying two coats of oil bound distemper over a coat of primer on new plastered surfaces of walls including preparation of surface complete all as specified and directed.
M&L for applying one coats of oil bound distemper on old plastered surfaces of walls including preparation of surface complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of plastered surface complete all as specified and directed.
M&L for applying one coats of white wash on old surface of ceiling including preparation of surface complete.
M&L applying one coat of synthetic enamel paint after preparation of old wooeden surfaces, exceeding 10 cm in width or girth, complete all as specified and directed.
M&L for preparation of old painted steel surfaces over 10 cm width/girth and applying one coat of synthetic enamel paint all as specified and directed.
S&F ball catches with 8mm dia steel ball, & brass body & striking plate including letting in & fixed
M&L for providing roof treatment including taking out existing treatment, and cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust & providing water proofing treatment with polymeric standard water proofing membrane, complete all as specified and described as under:- (a) Providing screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:3 over roof surface. (b) Preparation of surface and applying one coat of polymeric primer @ 0.30 kg / sqm. (c) Supply & providing APP based polymeric water proofing membrane 3 mm thick of weight not less than 3.60 kg / sqm reinforced with polyester non-woven fabric (weight not less than 150 gms/Sqm) centre core including coating the surface with the compatible primer and torch application of membrane with 10 cm overlaps as required thereof,
Srl item No. 111.00 contd-- complete all as specified and directed.(d) Applying one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm (Note:- The work of water proofing treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer, contractor shall submit documentary evidence in support of work executed through manufacturers/authorised applicator for approval of GE.
M&L in repair of 18/19mm thick pre-laminated particle board, interior grade, prelaminated on side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame.
S&F in repair 100mm MS Hasp and staples safety type, stove annmeled black including bolt to hings plate and fixed with screwed
S&F in repair 2nd class H/W plain fillets square, rectangular or triangular in section clean swan secured with nails or brads exc. 13 Sqcm & n.exc 25 Sqcm including dismantling of fillets complete.
Hacking out old broken glass (any thickness) size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones.
Cleaning & removing all scale & dirt etc from tanks & from mouths of circulating pipes etc of capacity exc 250 litres & not exc 500 litres with gunny bags, sand cleaning with fresh water and bleaching powder all as specified and directed by Engineer in Charge
M&L for one coat of french polishing on old surfaces of any description, width or girth including cleaning and preparing the surface including a coat with two or more coats wood filler.
Excavating in post holes (or similar holes) each n.exc 0.5 cum in hard/dense soil, getting out, returning, filling in, watering and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as foundation filling mass concrete complete all as specified and directed.
S&F structural steel compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc coforming to Fe-410 W Gde 250 quality A.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in soft/loose of soil for foundation, etc. or for shafts, wells, cesspits, manholes, pierholes, etc. and getting out complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as foundation filling mass concrete.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:4) complete (using old size bricks)
Returning filling in, including spreading, leveling and watering, well ramming n.exc 25cm thick layer in soft/loose soil complete all as specified and directed.
Removing Excavated material n.exc 50m and depositing where directed but not more than 1.5 high from the starting point complete all as specified and directed.
M&L for rendering 15mm thick on cement mortar (1:4) on fair faces of brick/concrete surfaces finished even and fair without using extra cement .
M&L PCC 50mm thick (1:2:4) type B-2 (using 40mm graded crushed stone aggregate) as in PCC hard standing, shall be laid in alternate bays, and divided in glass dividing strip finishing the cement concrete surfaces even and fair without using extra using cement. (Glass dividing strip shall be measured and paid separately).
Supply only glass dividing strip 3 mm thick, 48 mm wide inserted in floor to required design complete all as directed. (Note:- Rates for fixing glass dividing strip shall deem to be included in rates for laying of flooring.)
S&F structural steel work as in roof trusses (framed), trussed, purlins crane gantries, rails & fastenings & heavy brackets framimg (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc. Structural steel conforming to Fe-410W, Grade-E 250, Quality 'A' including dismantling of old structural steel work complete.
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screws, complete all as specified and directed.
S&F bib tap, cast copper alloy, (ISI marked) with crutch or butterfly handles screwed down screwed for iron pipe of 15mm bore complete all as specified ad directed.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for 25 mm thick screed bed or bedding layer in cement mortar 1:3 admixed with Dr Fixit pidiproof LW+ (as per standard IS :2645) @ 200 ml per bag of cement, finishing surface even and fair for base surface of water proofing treatement complete all as specified and directed.
M&L for taking down/demolition of existing flooring, PCC in the sunken portion such as bath, wc, Kitchens and providing and applying 2 coats of Dr. Fixit Pidifin 2K over well screeded/rendered floor/ wall surfaces (two component cementitious & acrylic flexible waterproofing & protective coating)( Sp. gravity @ 25 degree c, g/cc 1.65 - 1.75, Toxicity BS 6920 : part 1:2000 Non-toxic , Abrasion resistance, cm/km 0.09, Rapid chloride permeability- reduction in chloride ion penetration, is 90 % as per ASTM C1202: 1997, Hydrostatic (positive) water pressure resistance, bar as per DIN 1048 is 7, Hydraulic (negative) water pressure resistance, bar as per DIN 1048 is 3 ) over sunken slabs of Kitchen as per the spreading ratio of 1.5 - 2 kg /sqmtr for 2 coats.
Srl item No. 134.00 contd-- • The substrate has to be in SSD condition prior to application of 1st coat. After an interval of 4 – 6 hours apply the 2nd coat of Dr. Fixit Pidifin 2K.The total thickness of 0.80 – 1.0 mm will be achieved in 2 coats. • Providing and applying on horizontal surface a 10‐25 mm protective cements and mortar screed for sunken portions before admixed with approved integral waterproofing compound conforming to IS: 2645 like DR.FIXIT PIDIPROOF LW+ (Sp. gr. @ 25 degree C :- 1.05 - 1.070 , Non volatile content :- 13.5 - 14.5% , pH value :- 9- 13 , Chloride content as per IS : 2645 : 2003 Max. 2.00% , Water permeability as per IS : 2645 : 2003 Passes , Standard Compliance / Specification as per IS : 2645-2003 and IS: 9103-2000 standards) @ 200ML per 50kg bag of cement. • Around openings in masonry/concrete Pls sandwich 50 gsm geotextile cloth in two coats of PIDIFIN 2K. An additional third coat is required for such detailing.
Srl item No. 134.00 contd-- • At Floor & wall junction of sunken portion of wet areas the same procedure should be adopted as mentioned in above point. On vertical application sprinkle sand on 2nd coat of Pidifin 2K for applying cement sand plaster (1:4) 15 mm before admixed with approved integral waterproofing compound conforming to IS: 2645 like DR.FIXIT PIDIPROOF LW + (Sp. gr. @ 25 degree C :- 1.05 - 1.070 , Non volatile content :- 13.5 - 14.5% , pH value :- 9- 13 , Chloride content as per IS : 2645 : 2003 Max. 2.00% , Water permeability as per IS : 2645 : 2003 Passes , Standard Compliance / Specification as per IS : 2645-2003 and IS: 9103-2000 standards) @ 200ML per 50kg bag of cement. The treatment should be left to air cure for at least 72 hours.
M & L PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in leveling course to floors complete.
M & L Granite stone 15 mm thick on cooking plateform etc. and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigments to match the shade of the slab incl rubbing and polishing incl 15 mm thick rendering in CM 1:4 for recieve tiles complete all as specified and directed
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:4) complete (but except brick)
Taking down shutter of any description not exc. 1 sqm each complete all as specified and directed.
M&L Flush shutters,30 mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides
S&F of 75mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S&F 150 mm long,aluminium,anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete
S&F 150mm long MS Helical door spring Welded to steel /Fixed to wooden door frame including roller and roller plate etc complete of approved quality.
Hacking out old broken glass (any thickness, size, quality or description) from wooden or steel frames complete all as specified and directed.
S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples all as directed by Engineer- in -Charge.
S&F in repair 18/19 mm thick Block boards, grade 1 quality, exterior grade, decorative type with decorative face veneer on one face, fixed with screws as in cup board shutters & shelves etc all as directed by Engineer-in-Charge.
M&L plain fillets 18/19 mm wide 3mm thick 2nd class Hard wood ractangular in section, wrought secured with nails or barbs
M & L for decorative laminates 1.00 mm thick type I, or surface finish, colour and pattern as approved
S & F in repair of 6 mm thick plywood BWP grade type – BB, fixed with screws to timber frame as in linings, panelling , cupboards and similar location complete all as specified and directed.
S & F of 100 mm long Brass handles, cast type, polished bright complete all as specified and directed.
M & L for complete removal of existing treatement of walls
M & L rendering 5mm thick on ceiling in cement mortar 1:3 finished even and smooth complete all as specified and directed.
S & F in repair 15 mm dia CP brass Wall mixer with provision of over head shower complete with 115 mm long bend pipe, connecting legs & wall flange complete all as specified. Make:- Jaquar cat No. CON273KNUPR/ Marc ESSCO ES 517B /Prayag VIVA7298.
S & F in repair 15 mm dia CP brass centre hole WHB mixer (pillar tap) with accessories in wash basin for mixing hot and cold water, screwed down for 15 mm dia bore GI Pipe complete all as specified and directed. Make:- Jaquar cat No. CON167KNB/ Marc ESSCO cat No. ES516/ Prayag VIVA cat No. 7250
S&F in repair CP brass hot & cold 15 mm bore sink mixer with swinging casted spout (wall mounted) with connecting legs of flanges complete complete all as specified and directed.Make:- Jquar cat No. CON319KNB, Marc cat No. ES521, Prayag VIVA cat No. 7255
S&F in repair CP health faucet, hand shower type with 8mm dia 1 meter long flexible type & wall hook and jet of suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified and directed.
S & F in repair acreylic glass corner shelf with CP brass railing size not less than 300 mm long and fix to wall with rawl plug and CP screws complete all as specified and directed. Make Jaquar, Cat Part No ACN-1173 or equivalent as specified
S & F in repair brass CP towel ring 200 mm dia and 8 mm thick solid fixed with CP steel screw complete all as specified and directed. Make: Hindware cat part No. F 830002 / Prayag cat No. BA-11/ Jaquar AQN7721
S & F in repair soap dish, brass, chromium plated,100X100mm, fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed. Make: Hindware Cat Part No. F 830003 or equivalent model as specified. Make:- Jaquar/Prayag
S & F in repair vitreous china wash hand basin including brackets, white size 600 x 480 mm incl cutting cutting for and pinning in ends of brackets. including waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed including 32/40mm waste pipe pvc union complete all as specified.
S&F in repair 32/40mm dia waste coupling of CP Brass (half or full threaded) minimum weight not less than 45 grams for WHB/ sink complete all as specified and directed.
S&F in repair PVC waste pipe 32/40 mm dia complete all as specified and directed.
S & F in repair of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair 75 mm dia cast iron nahani trap, with CP grating including jointing to waste pipe and fixed in cement concrete 1:2:4 type B-1(using 20 mm graded stone aggregate) complete all as specified and directed.
S & F 20 mm bore gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete.
S&F sheet metal enclosure with socket plug top and MCB single pole and neutral with a two pin and earth plug & socket complete with single pole MCB 20/25 Amp with `C' curve type complete.
M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area) drawing in and including 25 mm dia or higher PVC conduit medium duty concealed, conduit accessories and fittings. Including one single core green colour PVC. Insulated unsheathed FRLS cable copper conductor multistranded of size 4 Sqmm as earth wire upto common earth and connected to earth dolly complete all as specified & directed. (Note:- Two run 6sqmm and one run 4sqmm and one run conduit shall be measured as one run)
S&F in sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 4 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 02 MCB SP as out going complete all as specified and directed.
S&F MCB single pole and 240 volt 10 KA 6-32 Amp 'B' series all as specified and directed.
S&F in replacement MCB SPN 240 Volt 10 KA 40 Amp 'C' series all as specified & directed.
S&F Gun metal globe or gate valve of size 20 mm dia with iron wheel head screwed both ends and for iron pipe & fixed, ISI marked, complete all as specified and directed.
M&L cross arm, bracing supports,clamps and back plates fabricated from structural steel section, such as channel, ISMC, dia angle iron , flat iron nut, bolts, washers welding, cutting drilling hole for insulator bolts clamps in any shape size & two coats of aluminum paint over one coat of red oxide zinc chromate primer all as directed by E-in-Charge.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator light fittings etc and removing from site and making good disturbed surfaces of walls floors etc. complete all as specified and directed by Engr-in-charge.
M&L for point wiring with 1.5 Sqmm. (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick bakelite laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following. (Note: Colour code shall be maintained as per IE rule)
One light point/ bell buzzer point controlled by one, one way switch
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two switch
All as per item No. 174.00 above here in but with 2.5 Sqmm. (nominal area) cable for phase & neutral for one 3 Pin 15 amp socket on independent board including one 1.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable FRLS,1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge.
S&F switch piano flush, button type 5 Amp SP 250 V one way AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
S&F switch paino flush button type 5 amp SP two way complete all as specified and directed.
S&F Bell switch paino flush button type 5 Amp 250 V complete all as specified.
S&F ding dong bell AC 230 V single pole complete all as specified and directed.
Taking down existing ceiling fans of any sweep and carrying out repair such as overhauling/servicing/replacement of bearing including spray painting & provisioning 3 core PVC cable multistranded copper cable 0.0076 BC cotton sleeve ceiling rose to connection including refixing of the same at existing places all as specified and directed.
Taking down existing exhaust fan of any sweep and carrying out repair such as overhauling/servicing/replacement of bearing including spray painting & provisionin 3 core PVC cable multistranded copper cable 0.0076 BC cotton sleeve ceiling rose to connection including refixing of the same at existing places all as specified and directed.
S&F step type,electronic fan regulator, 120watt, 240volts, two module socket type on the existing phenolic laminated sheet complete all as specified & directed.
S&F ceiling rose surface bakelite 3 terminals of size 65x25mm with back plate complete all as specified & directed.
S&F lamp holder, bakelite type with back platesuitable for batten fittings including 7w LED bulb retrofit type complete all as specified & directed.
S&F sheet metal enclosures 240 volt with suitable rated bus bar for double door 8 way IP-43 DB's IK-09 suitable for one MCB SPN as incoming and 6 MCB SP as out going, mounting flush on wall and making good disturb surfaces complete all as specified and directed by Engr-in-charge including taking out old u/s DB with MCBs) Make:- Legrand/ Scheider/ Simens/ L&T/ ABB Eligence/ C&S
S&F sheet metal enclosure 415 volts, TPN, 4 way double door, vertical type, IP 43 DB IK-09 suitable for MCCB incoming, and 12 SP MCB outgoing, mounted flush on wall, and making good disturbed surfaces complete all as specified including taking down old DB. (MCCB and MCB shall be measured and paid separately) Make:- Legrand/ Schneider /Simens /L&T/ ABB Eligence/ C&S
S&F MCCB 415 Volt 16 KA, 4 pole, 63 Amp, with adjustable thermal magnetic release ICs=100% ICu, complete all as specified & directed.
S&F in surface/Pendent mounting 1x20/22 W LED tube light fitting's Epoxy powder coated white extruded aluminium channel housing, Milky white, special polycarbonate diffuser, white coloured ABS end caps, better lumens and longer lamp life, high efficiency and lower power consumption, extra ordinary long life LED's, with & including 1 Nos 20/22 watt LED tube, complete and connected to ceiling rose with required length of two core flexible copper conductor cable (23/0.0076), fixed on walls/ceiling complete all as specified and directed. Make :- TMC 501 P1XT LED-22w P 3241 (fittings) 18 W 865 T 81 (LED tube) WIPRO LL13-181-65SE (Tube) W10921208 (fittings) Havells LHLDCLXEUL83020 (LED tube) LHFYBYPNIA1W022 (fittings)
M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm. dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe medium 15 mm. bore,
Srl item No. 192.00 contd--and water pipe 20 mm. bore GI light grade with funnel and wire mesh PCC chamber in cement concrete (1:3:6) type C-2 & 75 mm thick RCC (1:2:4) type B1 cover slab reinforced with 8mm TMT bars 100mm c/c both ways complete all as specified & shown in elect plate No. 3 of SSR part I of 2009 and testing on completion. (Note:- (i) If the desired earth resistance is not found within permissible limit shall be redone by the contractor at no extra cost. (ii) Cost of GI wirre 4 sqmm and 15mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item).
Supply, laying & connecting XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including fixing lugs, cable gland etc including bare conductor duly insulated with Pvc heat shrinkable sleeve 1.1 KV grade at both end complete all as specified and directed including taking out old u/s DB.
M&L for sand cushioning in trenches for protection of UG cable with river bed sand laid dry in trenches before and after laying of cable, including well ramming and consolidation complete all as specified and directed. (Note:- punned thickness shall be measured)
Supply & Laying well burnt bricks, sub class 'B' brick laid breadth wise, along the cable in trenches after sand cushioning laid for protection of UG cable protection complete all as specified and directed.
M&L for laying GI tubing light grade with all fittings of 50 mm bore fixed to wall/pole with MS clamp 2 nos 25x3 mm with nuts, bolt and washer complete all as specified and directed by Eng-in-Charge including taking out old u/s GI pipes.
S&F LED light fitting 1x10 watt bulk head LED type luminaries and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified & directed. Make:- Havell's cat part No- LHEOAOP7UZ6W010/Phillips model No. WT202W LED 6SCWPSUS2PC/ Crompton LBH 10-CDL.
S&F in replacement of U/S Tamper Proof electronic single phase whole current energy meter (LCD Display) 10 Amp to 60 Amp, 240 class 1.00 and 250 volt AC supply including cable connection, proper sealing with lead. The meter shall comply with the latest version of IS-13779 with atleast 2 anti tamper LED of line load reversal and earth loading indication with lead indication including eletrical connection with existing system and sealing properly including push fit type pvc transparent box. The meter shall work satisfactory with guarantee accuracy as per limit of IS-13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. (Note: Old U/S Meter shall be deposited to E/M store yard). Make:- Legrand/Secure/BHEL.
S&F air ventilation fan 300mm metallic type, heavy duty double ball bearing with louvers single phase 1300 RPM, 250V AC including necessary, making hole fixing arrangement on wall with frame 04 nos holdfastner, bolt, washer etc including connection with twisted white three core flexible copper multistranded conductor cable 23/0.0076 from ceiling rose to connector complete all as specified and directed by Engr-in-charge. Make:- Havells cat part No. Ventil Air DB, CG or Orient, (old Exhaust fan shall be deposited to MES store yard)
S&F in replacement air ventilation fan Plastic Type 250 mm , 1250 rpm,single phase, 250V AC including necessary, making hole fixing arrangement on wall with frame holdfastner, bolt,washer etc including connection with twisted white three core flexible copper multistranded conductor cable from ceiling rose to connector all a directed by Engineer-in-charge. Old Ex fan shall be deposited to MES store yard. Make-Havells Cat Part No Ventil Air DX WHT/BLK , CGCat No BRISKAIR or Orient ventilator DX
S&F Meter Distribution Board made out of Thermoplastic polycarbonate of size 450x600x170 mm (dust proof & weather proof ,Shock proof, rust proof ,corrosion free ,acid & Chemical resistance ,UV resistance ,Halogen free & freerecyclable material) wiyh 230v Ac 50 HZ 3 Wire , Gasket shallbe embedded with T-locking arrangement and suitable for mounting of Electronic Meter -04 Nos including electrical connection with existing system and sealing properly & taking out u/s broken/rusted box of any size and type complete all as specified and directed. Make of DB Hensel cat part no MI0600T / Secure/Sintex
S&F LED 10 Watt celing light, brown pattern & glass metal new generation 2700K, lumen 550 including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified. Make :- Philips cat No. 31140/44 Tigo/ Wipro cat No. LW01-101-XXX-60-XX/Syska-SSK CLS-01-12W 1x15 Retrofit LED
M&L light fittings wall mounted suitable for lamp 9 watt including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified. Make:- Havells BEETLE-15W or equivalent Crompton/ Philips
M&L sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty multi stranded copper conductor cable, FRLS of size 4 Sqmm (nominal area) drawing in and including 20 mm or higher dia PVC concealed conduit and conduit accessories and fittings including one single core green colour PVC insulated unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity conductor upto common earth and connected to earth dolly complete all as specified & directed. (Note: Two run 4sqmm and one run 2.5 Sqmm and one run condiut with accessories shall be measured as one run)
Asian Builder
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .