Loading…
Loading…
Tender Value
₹61.8 L
EMD Value
₹46,500
Closing Date
2 Sept 2026, 5:30 pm5d left
- ABHISHEK SINHA(DFLT)
PHED BALRAMPUR
On Risk & Cost PIPED WATER SUPPLY SCHEME FORVillage- KUNDI (Khaspara) ,KUNDI(Purvtola) BLOCK-WADRAFNAGAR District – Balrampur(C.G.) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 00 KL capacities – 00 No. & staging 12 mtr{STEEL STRUCTURE 12 M HEIGHT & 10 KL (5000L X 2NO.) – 03 No. And STEEL STRUCTURE 09 M HEIGHT & 10 KL (5000L X 2NO.)- 00No.} PE TANK & Elevated Service Reservoirs of RCC Staging and HDPE Slim Tank of capacity 5000 Ltr of 00 No. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 Ltr of 00 No. 12 mtr staging.including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber.Providing, laying, jointing, interconnection, testing and commissioning of rising main UPVC class 10 kg/sqcm 90 mm dia 00 m & HDPE 75mm dia 00 m &63 mm dia 540 m., distribution UPVC class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution HDPE class 6kg/sqcm 63 mm dia. 2715 m., 75 mm dia. 1965 m.with suitable joints GI Pipe, valve, specials and all fittings including all allied civil works, Supplying & Installation of Energy taging n five star BEE rating ISI Marked required capacity single phase / three phase, 50 Hz, 220V,, deep well submersible pump Stainless Steel body, suitable for 4”/6” tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSPDCL, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (F.H.T.C. 96 ) in individual households and government instiution etc. complete with trial run of 03 months after that O&M of 06 months under PIPED WATERVillage- KUNDI (Khaspara) ,KUNDI(Purvtola) BLOCK-WADRAFNAGAR District – Balrampur(C.G.)
196705
Nit 02 Date 04-08-2026 G 02
RESTRICTED TENDER
WORKS
PERCENTAGE
PHED BALRAMPUR
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
15 documents required · 15 mandatory
Public Health Engineering Department (PHED)
WORKS
- ABHISHEK SINHA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C D
PHED BALRAMPUR
TENDER SECTION
O/O EE & MEMBER SECRETARY (DWSM), PHE DIV, BALRAMPUR
1
No
0
196705
2 Sep, 2026 5:30:36 PM IST
4 Sep, 2026 5:30:50 PM IST
11 Aug, 2026 12:30:28 PM IST
Nit 02 Date 04-08-2026 G 02
On Risk & Cost PIPED WATER SUPPLY SCHEME FORVillage- KUNDI (Khaspara) ,KUNDI(Purvtola) BLOCK-WADRAFNAGAR District – Balrampur(C.G.) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 00 KL capacities – 00 No. & staging 12 mtr{STEEL STRUCTURE 12 M HEIGHT & 10 KL (5000L X 2NO.) – 03 No. And STEEL STRUCTURE 09 M HEIGHT & 10 KL (5000L X 2NO.)- 00No.} PE TANK & Elevated Service Reservoirs of RCC Staging and HDPE Slim Tank of capacity 5000 Ltr of 00 No. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 Ltr of 00 No. 12 mtr staging.including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber.Providing, laying, jointing, interconnection, testing and commissioning of rising main UPVC class 10 kg/sqcm 90 mm dia 00 m & HDPE 75mm dia 00 m &63 mm dia 540 m., distribution UPVC class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution HDPE class 6kg/sqcm 63 mm dia. 2715 m., 75 mm dia. 1965 m.with suitable joints GI Pipe, valve, specials and all fittings including all allied civil works, Supplying & Installation of Energy taging n five star BEE rating ISI Marked required capacity single phase / three phase, 50 Hz, 220V,, deep well submersible pump Stainless Steel body, suitable for 4”/6” tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSPDCL, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (F.H.T.C. 96 ) in individual households and government instiution etc. complete with trial run of 03 months after that O&M of 06 months under PIPED WATERVillage- KUNDI (Khaspara) ,KUNDI(Purvtola) BLOCK-WADRAFNAGAR District – Balrampur(C.G.)
46500.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
6181000.00
2
3 Sep, 2026 5:00:00 PM IST
6181000
AS PER NIT
AS PER NIT
AS PER NIT
311.00 INR
9
19d 17h 53m
15 documents required · 14 mandatory · 1 optional
₹311
₹46,500
11 Aug 2026
11 Aug 2026
4 Sept 2026
11 Aug 2026
3 Sept 2026
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
4786164296765290859_196705_705.docx
NIT • 4.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].