Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹16.8 L+₹1.6 L (10.5%)Rejected-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹16.9 L+₹1.7 L (11.4%)Rejected-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-AOC Rejected being higher bidder | |
| 4 | L4₹17.5 L+₹2.3 L (15.1%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-AOC Rejected being higher bidder | |
| 5 | Rejected-Technical 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | - | Rejected-Technical NO remarks has been given in WLR QE MAR 24 OF HQ CE AF GANDHINAGAR |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
3 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JODHPUR
GE AF JODHPUR
REPAIR MAINT OF MISC EM ASSETS AT AF STN JODHPUR
2024_MES_659717_1
8668/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JODHPUR
₹40,000
Yes
3 Sept 2024
14 Jun 2024
5 Jul 2024
14 Jun 2024
3 Jul 2024
21 Jun 2024
Amount
Supply and fixing in repair LED flood light 150 watt 230 V AC outdoor type made of pressure die cast aluminium housing, high power LEDs with potted drivers including fixing arrangement suitable size nuts and bolts, complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair brass Nozzels 1/8 inch dia adjustable type for high pressure on fountain pipe line complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair LED Aviation light-twin 8/6 watt with polycarbonate diffuser & cast aluminium housing IP 65 complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair LED Aviation light-single 8/6 watt with polycarbonate diffuser & cast aluminium housing IP 65 complete all as specified and directed by Engineer-in-Charge.
Labour only for disconnecting, taking out monoblock submersiable pump set, 3 ph, 415 V, AC of capacity 10 HP for repair and refixing after repair complete all as specified and directed by Engineer-in-Charge. Note :- The spare parts shall be measured and paid saparately in respective items of schedule.
Supply and fix in repair impeller CI suitable for 10 HP for monoblock submersible pump complete all as specified and directed.
Supply and fix in repair MS shaft with key suitable for monoblock submersible pump 10 HP complete all as specified and directed.
Supply and fix in repair pump body with terminal plates for monoblock submersible pump 10 HP complete all as specified and directed.
Material and labour for rewinding of monoblock pump set 10 HP with super enamelled copper wire complete all as specified and directed.
Labour only for disconnecting, taking out monoblock submersiable pump set, 3 ph, 415 V, AC of capacity 7.5 HP for repair and refixing after repair complete all as specified and directed by Engineer-in-Charge. Note :- The spare parts shall be measured and paid saparately in respective items of schedule.
Supply and fix in repair impeller CI suitable for 7.5 HP for monoblock submersible pump complete all as specified and directed.
Supply and fix in repair MS shaft with key suitable for monoblock submersible pump 7.5 HP complete all as specified and directed.
Supply and fix in repair pump body with terminal plates for monoblock submersible pump 7.5 HP complete all as specified and directed.
Material and labour for rewinding of monoblock pump set of capacity 7.5 HP with super enamelled copper wire complete all as specified and directed.
Supply, installation, testing and commissioning in repair submersiable pump set, Single phase 240 V, AC of capacity 1.0 HP complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning in repair LED Post Top gate light, 30 W, weatherproof with aluminium housing, IP 65 clear acrylic diffuser, aluminium pole-cap complete with all accessories, suitable for OD of 50 mm pipe including fixing arrangement such as pipe nuts and bolts complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning in repair LED Bollard stainless steel, 8 W/10 watt, weatherproof circular stainless bollard with acrylic diffuser IP 65 complete with all accessories complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning in repair LED fountain light, SS body (dia 5") 27 W,Red, Green blue complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning in repair DOL starter, single phase for 1 HP complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning in repair DOL submersible pump controller (Standard)-3 phase for 10 HP complete all as specified and directed by Engineer-in-Charge.
Material & labour in repairs for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of copper strip 20 mm X 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of strata, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe up to 7.5m complete all as specified and directed by the Engineer-in-Charge NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. Copper strip beyond 7.5 Metre shall be measured and paid for separately.
Supply and fix in repairs Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge.
Material & labour in repairs bore earthing 150 mm dia buried by vertical boring machine, depth 50 mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia ,15cm C/C on both side of the pipe including lowering in bore well upto the depth of 49 mtr and one metre above the ground level . The pipe electrode should be filled around commercial salt, charcoal dust , copper sulphate and magnisium phosphate of 30 cm layer each upto the full length of pipe. The bore well should have 12 metre of length 150mm dia MS pipe 4.8mm wall thickness for protection of bore well. Welding of GI strip 50x6 mm on earth electrode GI pipe 50mm dia upto the 10 metre below ground level and 15 metre from the bore well to test point gun metal and PCC foundation sorrounding the bore well 60x60x30 cm,complete all as specified and directed. Note :- If GI strip required more than 35 metres, than length exceeds 35 metres shall be measured and paid separately.
Supply and fix in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement galvanised steel strip 32mmx6mm complete with, protection sleeves, saddles, seperator and fixing screws at surrounding inside and outside the building complete all as specified and directed by the Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 32mm x 6 mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 4 core laid in trenches/fixed of wall/ through pipe complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 4 core laid in trenches/fixed of wall/ through pipe complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2 core laid in trenches/fixed of wall/ through pipe complete all as specified and directed by Engineer-in-Charge.
Taking out of LT cable any size from trenches/walls/floor etc complete all as specified and directed.
Supply, fix and testing in repairs 3 core multistranded copper flat cables for submersible pump motor of size 6 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs LT feeder pillar (kiosk) of of size not less than (L) 60 cm x (W) 45 cm x (H) 45cm made out of 3 mm thick CRCA sheet duly powder coated outdoor type double door with openable front door including locking arrangement with copper busbar 4P, 200 Amps rating with MCCB 125 Amps 4 pole 16 KA thermal magnetic adjustable type for incoming and space for fixing star delta starter complete fixed on angle iron 40x40x6mm frame of suitable size and embedded in PCC plinth 45x45x60mm made of PCC 1:4:8 type D-1 using 40 mm graded stone aggregate complete all as specified and directed by the Engr-in-Charge.
S&F in repairs LT feeder pillar (kiosk) of of size not less than (L) 60 cm x (W) 45 cm x (H) 45cm made out of 3 mm thick CRCA sheet duly powder coated outdoor type double door with openable front door including locking arrangement with copper busbar 2P, 200 Amps rating with MCB 63 Amps 2 pole for incoming and space for fixing star delta starter fixed on angle iron 40x40x6mm frame of suitable size and embedded in PCC plinth 45x45x60mm made of PCC 1:4:8 type D-1 using 40 mm graded stone aggregate complete all as specified and directed by the Engr-in-Charge.
Material and labour for submain wiring with single core PVC insulated multi stranded copper conductor cable FRLS of size 4.0 sqmm 1100 volt grade (ISI marked) drawn through and including non metalic PVC surface conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling with necessary fittings, with one 4.0 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
Supply and fix in repair central nozzel mashroom type upto 25 mm bore size for high pressure on fountain pipe line complete all as specified and directed by Engineer-in-Charge.
Supply, install, testing and commissioning in repair LED Post Top gate light, 70 W, weatherproof with aluminium housing, IP 65, clear acrylic diffuser, aluminium pole-cap complete with all accessories, suitable for OD of 50 mm pipe including fixing arrangement such as pipe nuts and bolts complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches,in soft/loose soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material & labour for tibba sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
Material & labour for stone slab 40mm to 50mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 cm to 30 cm wide and not less than 50cms in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed by the Engineer-in-Charge.
M/S KAUTILYA GARG
SANJOLI CONSTRUCTION COMPANY
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .