Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAdmitted-Finance | ₹3.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.1 CrAdmitted-Finance | ₹3.1 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SAINKO SYSTEMS L1 | AR ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Supplying, installation, testing and commissioning of online 3 phase UPS System with 30 minutes back up including batteries, interconnecting cables, battery racks etc 10 KVA complete in all respect. | 20 | kva | 21,000 ₹4.2 L | 21,000 ₹4.2 L |
| 2.00 | Supplying,installation,testing and commissioning of PassiveInfrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable forconnected load upto 10Amp , for mounting height up to 2.8mtr and for 5 m diameter coverage area along with necessary
fixing arrangements i/c programming at site etc. complete as required. | 60 | Nos. | 4,500 ₹2.7 L | 5,000 ₹3 L |
| 3.00 | Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high preformance, regulating programmable type,
suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. | 20 | Nos. | 4,500 ₹90,000 | 9,800 ₹2.0 L |
| 4.00 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as
required.2 output per phase. | 2 | Nos. | 9,000 ₹18,000 | 9,000 ₹18,000 |
| 5.00 | Supply, Installation, testing and commissioning of Salient Type DG set, with AMF Panel, bus ducting/ cables from DG set to Essential Panel, Synchronising Panel if reqd., DG set Enclosure room sound insulation, ventilation, smoke exhaust, Earthing of DG set System, control cabling, fuel Tank piping,exhaust chimney and piping,as per CPCB norms, Supply , Intallation of starting batteries of suitable AH as recommended by manufecture heavey duty complete as required at site complete with stand and battery charger residentials sylensor suotabe for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all , Day tank for fuel with markings ECP Panel mounted on a separate frame. Suitable space heater for alternators. Lub oil drain arrangement. Suitable amended arrangement for bus duct and arrangement for mounting differential /REF CTs. Suitable self priming pump with engine (if inbuilt in this model). DG shall be completely filled with luboil & HSD day fuel tank shall be completely filled one time. as required and as directed by engineer incharge. | 250 | kva | 15,500 ₹38.8 L | 13,000 ₹32.5 L |
| 6.00 | S.I.T.C of 11kV/0.433 kV outdoor Package type compact substation equipments comprising HT Panel, Dry type Transformers, HT cable, Bus trunking from Transformer to LT Panel, LT Panel, Automatic Power factor correction panel, Active Harmonic Filters,TVSS (Transient Voltage suppression system), SPD (Surge protection system), Essential panel,Earthing,required inter-connections, substation safety euipments including LT cabling from sub station to the buildings fed by the sub station. all necessary componetns like,1000 KVA 11KV/0.433 KV Dry Type TRANSFORMER CSS 1000 KVA compriising of 630 amps 11KV SF6 VCB DY11 Trsformer as INCOMER & 1 nos. 2600amps ACB, 3000amps TPN Bus Bar,800 amps 50 KA FPMCCB-4 nos, 630 amps 50 KA FPMCCB-4 nos, 400 amps50 KA FPMCCB-3 nos , 250 amps 36 KA FPMCCB-2 nos & 100 amps36 KA FPMCCB-3 nos as OUTGOINGS, in built in the enclsoure with 400 kvar capacitor panel. the technical specifications for the enclsoure, mouting arrangments, fixing of the Component, HT Gear, LT SwitchGear and Capacitor panel shall be specifications attached and to be fully complied including civil pedestal. Complete Package Substation including RMU, PSS enclosure and LV switchgears shall be made/supply of same OEM. 11 kv SF6 VCB Short time current 21KA for 3 sec, Internal Arc 20 KA for 1 sec. Dry Type Transformer 100KVA, 11KV/0.433KV with Off Circuit Tap Changer as per latest IS Standard., 1000 kVA continuous duty cycle, 11kV/433V, 3 phase, 50Hz, Dyn-11 vector group, step down, indoor type with IP23 or better enclosure, copper wound, dry type - Resin Casted transformer complete with off load tap changer & with all accessories, including winding temperature scanner with alarm and trip contact, fittings and conforming to specifications. Tap changing range shall be , ±5% in steps of 2.5% as per ECBC 2017. Transformer shall have cable box for 11kV XPLE cable on HT side & Busduct / Cable box on medium voltage side. Transformer should also have winding Temperature indicator Enclosure as per CPWD Specifications for Compact Sub station 1000 KVA Thermal magnetic type with double break technique, quick make and break type, Ics=Icu=100%, 50KA. PSS shall be inspeced by electrical Engineer /consultant / Architect at Manufecture plan. | 1,000 | KVA | 8,950 ₹89.5 L | 8,800 ₹88 L |
| 7.00 | S/F XLPE insulated screened PVC beded galvanized steel strip of wire armoured electric power cable (heavy duty) with aluminium conductor 11KV grads 3 core cross sectional area 185 sqmm as per diected by engineer-in-charge. For metering eqpt. | 25 | Rmt | 2,500 ₹62,500 | 4,700 ₹1.2 L |
| 8.00 | S/F XLPE insulated screened PVC beded galvanized steel strip of wire armoured electric power cable (heavy duty) with aluminium conductor 11KV grades3 core cross sectional area 300 sqmm as per diected by engineer-in-charge. For metering eqpt. | 120 | Rmt | 2,500 ₹3 L | 5,200 ₹6.2 L |
| 9.00 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 18 | Set | 8,000 ₹1.4 L | 8,000 ₹1.4 L |
| 10.00 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. | 540 | Mtr. | 750 ₹4.0 L | 750 ₹4.0 L |
Tender Value
₹3.1 Cr
EMD Value
₹6.2 L
Closing Date
5 Jan 2026, 3:00 pmClosed
DGM HQ BRIDCUL
BRIDCUL Opp Govt ITI Niranjanpur Saharanpur Road Dehradun
External Electrification work for State Guest House at Tanakpur, Dist Champawat
2025_BRID3_90267_2
2695/BRIDCUL/979/25 Dated 19.12.2025
Open Tender
Electrical Works
540 days
Champawat
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
MD - BRIDCUL
₹6.2 L
BRIDCUL Dehradun
8 Jan 2026
24 Dec 2025
5 Jan 2026
24 Dec 2025
5 Jan 2026
30 Dec 2025
29 Dec 2025
Amount
Supplying, installation, testing and commissioning of online 3 phase UPS System with 30 minutes back up including batteries, interconnecting cables, battery racks etc 10 KVA complete in all respect.
Supplying,installation,testing and commissioning of PassiveInfrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable forconnected load upto 10Amp , for mounting height up to 2.8mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high preformance, regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc.
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.2 output per phase.
Supply, Installation, testing and commissioning of Salient Type DG set, with AMF Panel, bus ducting/ cables from DG set to Essential Panel, Synchronising Panel if reqd., DG set Enclosure room sound insulation, ventilation, smoke exhaust, Earthing of DG set System, control cabling, fuel Tank piping,exhaust chimney and piping,as per CPCB norms, Supply , Intallation of starting batteries of suitable AH as recommended by manufecture heavey duty complete as required at site complete with stand and battery charger residentials sylensor suotabe for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all , Day tank for fuel with markings ECP Panel mounted on a separate frame. Suitable space heater for alternators. Lub oil drain arrangement. Suitable amended arrangement for bus duct and arrangement for mounting differential /REF CTs. Suitable self priming pump with engine (if inbuilt in this model). DG shall be completely filled with luboil & HSD day fuel tank shall be completely filled one time. as required and as directed by engineer incharge.
S.I.T.C of 11kV/0.433 kV outdoor Package type compact substation equipments comprising HT Panel, Dry type Transformers, HT cable, Bus trunking from Transformer to LT Panel, LT Panel, Automatic Power factor correction panel, Active Harmonic Filters,TVSS (Transient Voltage suppression system), SPD (Surge protection system), Essential panel,Earthing,required inter-connections, substation safety euipments including LT cabling from sub station to the buildings fed by the sub station. all necessary componetns like,1000 KVA 11KV/0.433 KV Dry Type TRANSFORMER CSS 1000 KVA compriising of 630 amps 11KV SF6 VCB DY11 Trsformer as INCOMER & 1 nos. 2600amps ACB, 3000amps TPN Bus Bar,800 amps 50 KA FPMCCB-4 nos, 630 amps 50 KA FPMCCB-4 nos, 400 amps50 KA FPMCCB-3 nos , 250 amps 36 KA FPMCCB-2 nos & 100 amps36 KA FPMCCB-3 nos as OUTGOINGS, in built in the enclsoure with 400 kvar capacitor panel. the technical specifications for the enclsoure, mouting arrangments, fixing of the Component, HT Gear, LT SwitchGear and Capacitor panel shall be specifications attached and to be fully complied including civil pedestal. Complete Package Substation including RMU, PSS enclosure and LV switchgears shall be made/supply of same OEM. 11 kv SF6 VCB Short time current 21KA for 3 sec, Internal Arc 20 KA for 1 sec. Dry Type Transformer 100KVA, 11KV/0.433KV with Off Circuit Tap Changer as per latest IS Standard., 1000 kVA continuous duty cycle, 11kV/433V, 3 phase, 50Hz, Dyn-11 vector group, step down, indoor type with IP23 or better enclosure, copper wound, dry type - Resin Casted transformer complete with off load tap changer & with all accessories, including winding temperature scanner with alarm and trip contact, fittings and conforming to specifications. Tap changing range shall be , ±5% in steps of 2.5% as per ECBC 2017. Transformer shall have cable box for 11kV XPLE cable on HT side & Busduct / Cable box on medium voltage side. Transformer should also have winding Temperature indicator Enclosure as per CPWD Specifications for Compact Sub station 1000 KVA Thermal magnetic type with double break technique, quick make and break type, Ics=Icu=100%, 50KA. PSS shall be inspeced by electrical Engineer /consultant / Architect at Manufecture plan.
S/F XLPE insulated screened PVC beded galvanized steel strip of wire armoured electric power cable (heavy duty) with aluminium conductor 11KV grads 3 core cross sectional area 185 sqmm as per diected by engineer-in-charge. For metering eqpt.
S/F XLPE insulated screened PVC beded galvanized steel strip of wire armoured electric power cable (heavy duty) with aluminium conductor 11KV grades3 core cross sectional area 300 sqmm as per diected by engineer-in-charge. For metering eqpt.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 2x6
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 2x16
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 4x25
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x35
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x70
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x95
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x120
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x185
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5 x 240 sq. mm
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5 x 300 sq. mm
S/M OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: upto 185 sq. mm
S/M OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: upto 300 sq. mm
supplying and making indoor cable end termination with heatshrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core,185 sq.mm, XLPE aluminiumconductor cable of 11 KV grade as required :
supplying and making indoor cable end termination with heatshrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core,300 sq.mm, XLPE aluminiumconductor cable of 11 KV grade as required :
S/E of three piece nonlinear resistor type lighting arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharege current rating of 5 KV and complete with galvanised clamping arrangenment, G.I. bolts, nuts, washers etc. as required.
SITC of OutDoor Type, Double Door Feeder Pillar with minimum 2mm thick MS sheet 9 Tank treatment powder coated Painted with Sloping Canopy suitable size of TPN Aluminium Bus Bar, Earth Bar,Pad locking arrangement, LED Indication Lights, Detachable Gland Plate, fixed on CC Foundation with making suitable CC foundation capable to accomodate the following MCCBs, Interconnection etc. as reqd. OutDoor Type 400 A,36KA,TPMCCB 1 no, 100A,36KA,FPMCCB 10 nos
SITC of OutDoor Type, Double Door Feeder Pillar with minimum 2mm thick MS sheet 9 Tank treatment powder coated Painted with Sloping Canopy suitable size of TPN Aluminium Bus Bar, Earth Bar,Pad locking arrangement, LED Indication Lights, Detachable Gland Plate, fixed on CC Foundation with making suitable CC foundation capable to accomodate the following MCCBs, Interconnection etc. as reqd. OutDoor Type, 250 A,25KA,TPMCCB 1 no ,100 A,16KA,TPMCCB 9nos
SITC of OutDoor Type, Double Door Feeder Pillar with minimum 2mm thick MS sheet 9 Tank treatment powder coated Painted with Sloping Canopy suitable size of TPN Aluminium Bus Bar, Earth Bar,Pad locking arrangement, LED Indication Lights, Detachable Gland Plate, fixed on CC Foundation with making suitable CC foundation capable to accomodate the following MCCBs, Interconnection etc. as reqd. Main Feeder Pillar Panel 100 A,16KA,TPMCCB 4 nos., 200 A,36KA,FPMCCB 3 nos. 400 A,36KA,TPMCCB 3 nos. , 630 A 50KA FPMCCB-2 no.
SITC of OutDoor Type, Double Door Feeder Pillar with minimum 2mm thick MS sheet 9 Tank treatment powder coated Painted with Sloping Canopy suitable size of TPN Aluminium Bus Bar, Earth Bar,Pad locking arrangement, LED Indication Lights, Detachable Gland Plate, fixed on CC Foundation with making suitable CC foundation capable to accomodate the following MCCBs, Interconnection etc. as reqd. street light Feeder Pillar 100 A,16KA,TPMCCB 1 nos. 4w HTPDB+SPMCBs-12nos,63 amps FP MCB Isolator-1no.Photosensor Swtich unit with Power contactor ML-3
Supply, Errection, installtion, testing & commissioning of of 6 meter high street Light GI 8 Polygon octegonal pole of 300 thick sheet Grade ISH480LA as per IS:5986:2017 latest,Regional wind withstand capacity which the pole structure support is suitable to withstand 50 m/s,base plate 200mmx200mmx12mm material Grade:E300, Quality:BR (as per IS:2062:201 1 latest) with GI Lightning Finial, with single one meter long arm and built in loop inTerminal Box with Circuit breakers and backlite sheet for cable termination at door opening (Base compartment) for each poleMCB, 16A, 1P, 240V, AC with din bar, neutral Bar Earh Bar minimum mass of coating 360Gms/Sq. Mtrs with LED Aviation light ,Suitable M16x600 as per IS:1367 (Part 2) , Grade Afoundation J Bolts - 4 nos.,Nuts per bolt - 3 nos.,Washers - 3 nos., with earhing terminal ,2 C x 1.5 Sq.mm, Copper cable, FR Category as per IS:694 connections from the top junction box to the individual luminaries of each pole including RCC 1:2:4 foundation including excavation, refilling, Reinforcement etc. as per Pole Manufacture design withSupplying and fixing 60W LED streetlight made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection complete with all accessaries including testing commissioning Etc as reqd..
SITC 16 meters High Mast Lighting Towerhot dip galavnised average 86 micron thickness, fabricated with special steel p[lars of 355 gradeasper BSEN10 025 in two sections bottom daimeter 570mm with 740mm Dia x 25mm thick base plate capable of handling Maximum Wind load 50 m/sec Size of opening and closing door at base compartment of high mast (Minimum1200 x 250mm) Ingress protection for Junction Box IP66, with winch shall have provision for manual operation in case of failure of the motor and feeder pillar suitable for the cable of 4x4 sq.mm Copper cable 3 phase 4 wire 400v 50 Hz ac supply and connecting wires of commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt rules and regulations as applicable) includuing all civil works for large area with LED Flood Lighting System with 12 nos LED200W FLOOD LIGHT, System efficiency >100lm/w,90 to 300 Volts AC at 50Hz+/-2Hz 6000K (+/- 500K) IP65 shall be protected against surges and transients( Internal) >/=5KV one Number of electronic control gear per luminaire (power supplies) luminaries earhing connections etc as reqd
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe,in Duct trench/cable tary etc. as required. 2x6 sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 2x16 sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 4X16 Sq.mm.
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 3.5x35 Sqmm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 3.5x70 Sqmm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 3.5x95 Sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 3.5x120 sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 3.5x 185 Sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 3.5x240 Sqmm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of 3.5x300 sq.mm
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100mm
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 150mm
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required 150 mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required 300mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 160mm
Supplying and installing following size of perforated hot dipped galvanised iron cable trays (galvanisation thickness not less than 50 micron) with perforation not morethan 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated hot dipped galvanised iron cable trays (galvanisation thickness not less than 50 micron) with perforation not morethan 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
AR ENTERPRISES (BID ID -413276)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
sbdexternalstateguesthousetanakpurf.pdf
Tender Documents • 1.80 MB
BOQ_106974.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid