Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.4 LAccepted-AOC TV 22 349 MEDFLOW FORT ROAD KANNUR 670001 | KANNUR | KANNUR | KERALA | 670001 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹61.2 L+₹1.7 L (2.89%)Rejected-Finance PUTHUKKUDI GREESHMAM HOUSE ELATHUR POST KOZHIKODE 673303 | KOZHIKODE | KOZHIKODE | KERALA | 673303 | L2 | Rejected-Finance L2 Bidder | |
| 3 | Rejected-Technical 37 3461 NH ROAD DESABHIMANI JUNCTION KALOOR ERNAKULAM 682017 | ERNAKULAM | ERNAKULAM | KERALA | 682017 | - | Rejected-Technical Documents as per SQC not submitted |
Tender Value
₹59.9 L
EMD Value
₹50,000
Closing Date
23 Dec 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Regional Manager, WAPCOS Kochi Office
WAPCOS Limited. 4th Floor, ISAACS Tower, Jawahar Nagar, Kadavanthra, Kochi, Kerala-682020
Establishment of Pediatric Care Unit under ECRP II at WC Palakkad
2021_WAPCO_458041_1
WAP/INFRA/KERALA/WCP/2021/363
Open Tender
Civil Works - Others
Item Rate
90 days
W C Palakkad
Please refer Tender documents.
22 documents required · 22 mandatory
₹2,800
₹50,000
5 Apr 2022
3 Dec 2021
23 Dec 2021
3 Dec 2021
23 Dec 2021
7 Dec 2021
90 days
Amount
MEDICAL GAS PIPELINE WORKS
od176476/2021_2022 : Air Outlets
od176477/2021_2022 : Outlets Vaccum
od176478/2021_2022 : Flow meter
od176479/2021_2022 : Ward vaccum units
od176480/2021_2022 : Alarm 3 gas
od176481/2021_2022 : Valve Box 3 gas
od176482/2021_2022 : Bed Head Pannel (1500 mm )
od176485/2021_2022 : Copper Pipe 12mm
od176486/2021_2022 : Copper Pipe 15 mm
od176487/2021_2022 : Copper Pipe 22mm
od177323/2021_2022 : Oxygen Gas Outlets
MINOR CIVIL WORKS
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
12.45.1 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
od177669/2021_2022 : Providing and fixing floor trap of PVC,110 mm outer dia(multi trap) including CPcockroach free floor grating with cup etc including cost and conveyance of all materials, labour charges,sundries etc complete as directed by the Engineer-in-Charge at all levels
od177369/2021_2022 : Toilet PVC Door
od177370/2021_2022 : Aluminum Partition including 2 doors of size
HVAC WORKS
od243875/2021_2022 : Supply, Installation, testing commissioning of factory built Ceiling Suspended DX double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters, germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used.<br>Horizontal Ceiling Suspended AHU <br>5.5 TR/ 2000 CFM/ 6 RD/ 20 mm ESP
od243876/2021_2022 : Supply, Installation, testing commissioning of factory built Ceiling Suspended DX double Skin horizontal Air handling units made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain AL sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) & 5 micron fine filters, mixing box with fresh air intakes with dampers,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings , strip heaters, germicidal UV-C lamps etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used. Horizontal Ceiling Suspended AHU <br>8.5 TR/ 3000 CFM/ 6 RD/ 20 mm ESP
od243877/2021_2022 : Supply, Installation testing and commissioning of the air cooled outdoor unit (condensing unit). It shall be of corrosion resistant galvanized powder coated or equivalent sheet steel assembly installed on suitable vibration isolators and comprising of energy efficient Scroll compressor with controls such as thermal protector, HP/LP cutouts, Pressure relief valve and condenser fan unit; the units shall have integral refrigerant copper piping within compressor and condenser and accessories such as refrigerant shut off valves at compressor / compressors and liquid refrigerant outlet if required & filter dryer, with R 410 A refrigerant; Cooling fans shall have protective metal frame.The Outdoor units within Sunshade and on Terrace shall be installed on MS angle iron frame duly corrossion proof painted and supplied as welded structure which shall be securely grouted on floor and duly painted with anti-corrosive paint; the frame shall be isolated from floor through adequate vibration isolation; Price shall be inclusive of all required MS supports.<br>Rates shall be including supply and commissioning of matching rated factory supplied Electrical Starter & Control Panel. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 Note: Control cables connecting the IDU and the ODU & 6 SMG GI wire loop Earthing shall be included in Split unit cost and on lot basis and run on the Power cable trays with adequate supports and electrical protection 5.5 TR
od243878/2021_2022 : Supply, Installation testing and commissioning of the air cooled outdoor unit (condensing unit). It shall be of corrosion resistant galvanized powder coated or equivalent sheet steel assembly installed on suitable vibration isolators and comprising of energy efficient Scroll compressor with controls such as thermal protector, HP/LP cutouts, Pressure relief valve and condenser fan unit; the units shall have integral refrigerant copper piping within compressor and condenser and accessories such as refrigerant shut off valves at compressor / compressors and liquid refrigerant outlet if required & filter dryer, with R 410 A refrigerant; Cooling fans shall have protective metal frame.The Outdoor units within Sunshade and on Terrace shall be installed on MS angle iron frame duly corrossion proof painted and supplied as welded structure which shall be securely grouted on floor and duly painted with anti-corrosive paint; the frame shall be isolated from floor through adequate vibration isolation; Price shall be inclusive of all required MS supports.<br>Rates shall be including supply and commissioning of matching rated factory supplied Electrical Starter & Control Panel. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 Note: Control cables connecting the IDU and the ODU & 6 SMG GI wire loop Earthing shall be included in Split unit cost and on lot basis and run on the Power cable trays with adequate supports and electrical protection.<br>8.5 TR
od243879/2021_2022 : SITC of ceiling suspended air cooled ductable split air-conditioners each complete with Inverter type scroll compressor, air cooled condenser ,GSS casing, washable prefilters, cooling coils, R410 A refrigernet , corded remote with fan speed and ESP setting, Electronic expansion valve refrigerant controls, vibration isolators, Micro processor based controller and all other standard accessories for following unit. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 deg C ambient temperature without tripping. The unit shall be suitable to work on 400V+/-10%,3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 <br>11 TR
od243883/2021_2022 : Supply, Installation, Testing & Commissioning of GI Sheet metal ducting work complete with all fittings such as Tee, Bends, Turning vanes including, suspension and supporting arrangement as required and necessary joints sealed with silicon.<br>0.6mm GSS Ducting
od243884/2021_2022 : Supply, Installation, Testing & Commissioning of GI Sheet metal ducting work complete with all fittings such as Tee, Bends, Turning vanes including, suspension and supporting arrangement as required and necessary joints sealed with silicon.<br>0.8mm GSS Ducting
od243885/2021_2022 : Supply & fixing of 10 mm thick open cell nitrile rubber form with density 140-180kg/m3 along with antimicrobial product protection as acoustic insulation for ducts using suitable adhesive as per the recommendation of the insulation manufacturer.
od243886/2021_2022 : Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber(Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. Density of insulation material shall be between 40 to 55 Kg/m3.The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.13 mm thick Anti Microbial Nitrile Rubber insulation.
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
od243894/2021_2022 : Supply, Installation, Testing of Extruded Aluminum powder coated return air grilles with horizontal fixed bars and end flanges with damper.
od243888/2021_2022 : Supply, fabrication, installation, testing of flexible connections made out of fire resistant flexible double canvas sleeve.
od243889/2021_2022 : SITC of 25mm OD uPVC Sch 40 pipe with 9mm thick aniti microbial nitrile rubber sleeve insulation for condensate drain piping of AHUs to the nearest drain point.
od243890/2021_2022 : Supply Installation Testing and commissioning of Inline Duct Exhaust fan with speed regulator of following CFM including UVC Lamp mounted inside plenum box with all necessary supports & fixing arrangement.<br>800 CFM/20 mm ESP
od243891/2021_2022 : Supply Installation Testing and commissioning of Inline Duct Exhaust fan with speed regulator of following CFM including UVC Lamp mounted inside plenum box with all necessary supports & fixing arrangement.<br>450 CFM/20 mm ESP
od243892/2021_2022 : Supply Installation Testing and commissioning of Inline Duct Fresh Air fan with speed regulator of following CFM along with Pre-Filter, Fine Filter & HEPA Filter including all necessary necessary supports & fixing arrangement.<br>800 CFM/30 mm ESP
RAJAN P
Bidder Name
RAJAN P
RAGUNATH CHERIYATH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .