DGMM
TELK,ANGAMALY
Onsite Calibration of Tan Delta and Capacitance Meters,Schering Bridges and Standard Capacitors Total No. of Instruments 7
2020_TEKL_348176_1
TELK/C AND M/QA/CAL/237/2020
Open Tender
Miscellaneous Works
Item Wise
730 days
TELK, ANGAMALY
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,400
Yes
online
₹10,000
Yes
2 Jul 2020
5 Mar 2020
23 Mar 2020
5 Mar 2020
20 Mar 2020
5 Mar 2020
Tan Delta & Capacitance Meter, Make & Serial No :OMICRON,CPTD1, KF231A,GK830Q Range of Instrument: Capacitance: 10 to 100000 pF, Tan delta : 0.01 ~ 100 % Calibration required atleast at following range : Capacitance: 100 ~ 1000 pF, Tan delta: 0.1 ~ 5 % Voltage at which to be Calibrated: Atleast 3 kV
Schering Bridge, Make & Serial No :TETTEX.AG,2801, 128.351 Range of Instrument: Capacitance: 50 to 10000pF, Tan delta : 0.01 ~ 10 % Calibration required atleast at following range : Capacitance: 100 ~ 1000 pF, Tan delta: 0.1 ~ 5 % Voltage at which to be Calibrated: Atleast 3 kV
Schering Bridge Make & Serial No : TETTEX.AG,2805, 125.103 Range of Instrument: Capacitance: Capacitance: 50 ~ 10000 pF, Tan delta : 0.01 ~ 10 %, Calibration required atleast at following range : Capacitance : 100 ~ 1000 pF, Tan delta : 0.1 ~ 5 % Voltage at which to be Calibrated: Atleast 3 kV
Schering Bridge Make & Serial No : TETTEX.AG,2805, 125.104 Range of Instrument: Capacitance: Capacitance: 50 ~ 10000 pF , Tan delta : 0.01 ~ 10 % Calibration required atleast at following range : Capacitance : 100 ~ 1000 pF, Tan delta : 0.1 ~ 5 % Voltage at which to be Calibrated: Atleast 3 kV
Standard Capacitor Make & Serial No :HITACHI, 567118-1, Model: PI Range of Instrument: Capacitance: 250kV, 100.65 pF, Accuracy ±1% Calibration required atleast at following range : 100 pF Voltage at which to be Calibrated: Atleast 10 Kv
Standard Capacitor Make & Serial No :MICAFIL,74H115, Model:PGA - 5 Range of Instrument: Capacitance: 500kV,100.35 pF, Accuracy ±1% Calibration required atleast at following range : 100 pF Voltage at which to be Calibrated: Atleast 10 kV
Standard Capacitor Make & Serial No :NISSIN,20287 Range of Instrument: Capacitance: 10 kV, 1000PF Calibration required atleast at following range : 1000 pF Voltage at which to be Calibrated: Atleast 3 kV
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .