CHIEF ENGINEER BAREILLY ZONE
HQ CE BAREILLY ZONE
SPECIAL REPAIRS TO REPLACEMENT OF E/M ITEMS AGAINST BER UNDER GE (WEST) BAREILLY
2026_MES_767857_1
CEBZ/BLY/T-07 OF 2026-27
Open Tender
Civil Works
Item Rate
BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (WEST)
₹2.8 L
Yes
22 Aug 2026
26 May 2026
10 Aug 2026
26 May 2026
3 Aug 2026
15 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5 mtr width and not exce 1.5 mtr in depth in soft/loose soil and getting complete all as specified and as directed. | 32.4 | Cum | - | - |
| 2 | M & L for dry sand cushioning to under ground electric cable on layer of 8cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1
Note: Punned thickness will be considered for measurement | 6.5 | Cum | - | - |
| 3 | Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. | 100 | Each | - | - |
| 4 | Laying only precast concrete cable cover of any size complete all as specified and as directed. | 420 | Each | - | - |
| 5 | Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed. | 24.8 | Cum | - | - |
| 6 | Removal of excavated material to a disance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. | 7.6 | Cum | - | - |
| 7 | M&L for Disconnecting of HT connections of existing transformer/VCB with earthings carefully and shifting the same from platform/sub station to AGE E/M Store yard including existing foundation will be repair and painted with white wash as per site requirement complete all as specified and as directed. | 13 | Each Job | - | - |
| 8 | Supply, installation, commissioning and testing complete with all accessories of transformer of 33 KV capacity 5 MVA step down, outdoor type, floor mounted, double copper wound, 3 Phase, 50 Hz, AC, Oil immersed, ONAN/ONAF confirming to IS-2026 and IEC 62770 including cooling fans, external cooling tubes/radiator cores type having voltage ratio 33000/11000 volts (corresponding to principal tapping) winding delta connecting on Primary side and star connected on secondary side in accordance with vector symbol Dyn-11 (vector Group) with neutral brought out on secondary side and looping on HV side for contact output so as to alter/vary secondary voltage by + 7.5% in 8 steps of 2.5% each to be changed by means of (OLTC) Off Load Tap Changer. Transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with m4 grade or Better, Perfectly insulated and clamped to minimize noise and vibrations, core shall be purchased directly from manufacturer of core or from their accredited marketing network and not through any agent. Before placing order for procurement of transformer, the contractor shall submit the credentials in respect of the manufacturer of core and transformer shall be procured only after approval from GE in respect of name of manufacturer of transformer as well as manufacturer of core. The limit of termperature rise after continous full load runs as specified in IS/IEC 60076 shall be suitably adjusted to suit the ambient temperature of maximum 50 degree celsius prevailing at site all as specified and directed including having following characteristics :- | 1 | Each Job | - | - |
| 8.01 | The transformer shall confirm to the latest edition of applicable standard as follows :-
(i) IS-2026, for tests and tolerance of guarnteed Particulars.
(ii) IS-3639 for Fitting and accessories.
(iii) IS-2099 for Bushing >1000V.
(iv) IS-7421 for Bushing <1000 V
(v) IS-1271 for Electrical insulation classified by Thermal stability. | - | - | - | - |
| 8.02 | (a) Winding
(i) Primary Side Winding - Layer/disc winding (ii) Secondary Side Winding - Helical/Disc widing
(b) Insulation Level
(i) Primary Side - 170 (ii) Secondary Side - 70
(c) Insulation level (Power frequency with Stand KVrms)
(i) Primary Side - 70 (ii) Secondary Side - 28 | - | - | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_859909.xls
BOQ • 0.34 MB
tender.pdf
Tender Documents • 2.57 MB
882261.pdf
PDF • 0.07 MB
882261.pdf
PDF • 0.07 MB
882261.pdf
PDF • 0.07 MB
882261.pdf
PDF • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .